Please read these operating instructions thoroughly before using your air conditioner and keep for future reference.
For assistance, please call : 1-800-211-PANA(7262) or Register your product at : http://www.panasonic.com/register
INSTALLATION AND
OPERATING INSTRUCTIONS
Room Air Conditioner
2
Safety Precautions
About the Controls on the Air Conditioner
Features and Installation
Before you call for service...
WARNING
3

Safety Precautions

Safety Precautions

To prevent injury to the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring of instruction will cause harm or damage. The seriousness is classified by the following indications.
WARNING : This symbol indicates the possibility of death or serious injury.
CAUTION
:
This symbol indicates the possibility of injury or damage to property only.
Meanings of symbols used in this manual are as shown below.
Be sure not to do this.
Be sure to follow the instructions.
Plug in the power plug properly.
• Otherwise, it will cause electric shock or fire due to heat generation.
Do not operate or stop the unit by inserting or pulling out the power plug.
• It will cause electric shock or fire due to heat generation.
Do not damage or use an unspecified power cord.
• It will cause electric shock or fire.
If the power cord is damaged, it must be replaced by the manufacturer or an authorized service center or a similarly qualified person in order to avoid a hazard.
Do not modify power cord length or share the outlet with other appliances.
• It will cause electric shock or fire due to heat generation.
Do not operate with wet hands or in a damp environment.
• It will cause electric shock.
Do not direct air flow at room occupants.
• This could lead to health problems.
4
Safety Precautions
VENTCLOSE
OPEN
Par t
A
Par t
B
7
About the Controls on the Air Conditioner

Air Filter Cleaning

The air filter behind the front grille should be checked and cleaned at least once every 2 weeks or more often if necessary.
TO REMOVE:
1. Open the inlet grille upward by pulling out the bottom of the inlet grille or downward by pulling out the top of the inlet grille.
2. Using the tab, pull up slightly on the filter to release it and pull it down or up.
3. Clean the filter with warm, soapy water under 40°C (104°F).
4. Rinse and gently shake the water from the filter and let it dry before replacing it.
CAUTION: DO NOT operate the air conditioner without a filter because dirt and lint will
clog it and reduce performance.

Care and Maintenance

TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET.
8
Features and Installation
Learning parts name prior to installation will help you understand the installation procedure.

Features

Features

CABINET
FRONT GRILLE
AIR FILTER
AIR INTAKE (INLET GRILLE)
AIR DISCHARGE
REMOTE CONTROLLER
HORIZONTAL AIR DEFLECTOR (VERTICAL LOUVER)
VERTICAL AIR DEFLECTOR (HORIZONTAL LOUVER)
EVAPORATOR
CONTROL BOARD
POWER CORD
BASE PAN
CONDENSER
COMPRESSOR
BRACE
About 12.7mm (1/2")
76.2cm (30")~
152.4cm (60")
Awning
Cooled air
Fence
Over 50.8cm (20")
Heat
radiation
55.8cm (22") to
91.44cm (36")
Offset
12.7mm (1/2") to
31.8mm (1
1
/4")
Sill
Exterior
Interior wall
47cm (181/2") min.
(Without frame curtain)
Stool
38cm (15") min
(With frame curtain)
9

INSTALLATION

Features and Installation
1. To prevent vibration and noise, make sure the unit is installed securely and firmly
2. Install the unit where the sunlight does not shine directly on the unit.
3. The outside of the cabinet must extend outward for at least 28cm (11") and there should be no obstacles, such as a fence or wall, within 50.8cm (20") from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner.
CAUTION: All side louvers of the cabinet must remain exposed to the outside of the
structure.
4. Install the unit a little slanted so the back is slightly lower than the front (about 12.7mm (1/
2")).
This will force condensed water to flow to the outside.
5. Install the unit with the bottom about 76.2cm (30")~152.4cm (60") above the floor level.

Window Requirements

NOTE: All supporting parts should be secured to firm wood, masonry, or metal.
This unit is designed for installation in standard double hung windows with actual opening widths from 55.88cm (22") to
91.44cm (36").
The top and bottom window sash must open sufficiently to allow a clear vertical opening of 38cm (15") from the bottom of the upper sash to the window stool.

How to Install the Unit

9
Loading...