INSTRUCTION MANUAL
Digital Fiber Sensor Amplifier FX-301-HS
ME-FX301HS No.0017-07V
Thank you very much for purchasing Panasonic products. Please read this Instruction
Manual carefully and thoroughly for the correct and optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
٨٨Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use prod-
WARNING
For further details on the fiber sensor amplifier, please refer to 'Panasonic Electric
Works SUNX website (http://panasonic-electric-works.net/sunx)' or contact our office.
1
SPECIFICATIONS
Item FX-301P-HSFX-301-HS
Power consumption
Output
Short-circuit protection
Response time
Sensitivity setting
Fine sensitivity
adjustment function
Timer function
Ambient temperature
Material
Notes: 1)2)50mA, if five, or more, amplifiers are connected in cascade.
2
MOUNTING
How to mount the amplifier
ԘԙFit the rear part of the mounting section of the amplifier
on a 35mm width DIN rail.
Press down the rear part of the mounting section of the
unit on the 35mm width DIN rail and fit the front part of
the mounting section to the DIN rail.
How to remove the amplifier
ԘԙPush the amplifier forward.
Lift up the front part of the amplifier to remove it.
Take care that if the front part is lifted without pushing the amplifier forward, the hook on the
Note:
rear portion of the mounting section is likely to break.
How to connect the fiber cables
Be sure to fit the attachment to the fibers first before inserting the fibers to the
amplifier. For details, refer to the instruction manual enclosed with the fibers.
Ԙ
Snap the fiber lock lever down.
ԙ
Insert the fiber cables slowly into the inlets until they
stop. (Note 1)
Ԛ
Return the fiber lock lever to the original position, till it
stops.
Notes: 1)2)In case the fiber cables are not inserted to a position where
ucts which meet laws and standards, such as OSHA, ANSI or IEC
etc., for personnel protection applicable in each region or country.
Model No.
Normal operation: 960mW or less
ECO mode: 600mW or less
<NPN output type>
NPN open-collector transistor
Applied voltage: 30V DC or less
Residual voltage: 1.5V or less
Incorporated with variable ON-delay / OFF-delay / ONE-SHOT timer,
switchable either effective or ineffective (Timer: approx. 0.5 to 9999ms)
Enclosure: Heat-resistant ABS, Transparent cover: Polycarbonate
Press switches: Acrylic, Jog switch: Heat-resistant ABS
The cable for amplifier connection is not supplied as an accessory. Make sure to use the
optional quick-connection cables given below.
Main cable (3-core): CN-73-C1 (cable length 1m), CN-73-C2 (cable length 2m)
Sub cable (1-core): CN-71-C1 (cable length 1m), CN-71-C2 (cable length 2m)
they stop, the sensing range reduces. In case of a flexible
fiber, take care that it may bend inside the amplifier, during
insertion.
With the coaxial reflective type fiber, such as, FD-G4 or FD-FM2, insert the single-core fiber
cable into the beam-emitting inlet and the multi-core fiber cable into the beam-receiving
inlet. If they are inserted in reverse, the sensing accuracy will deteriorate.
NPN output
12 to 24V DCr10% Ripple P-P 10% or lessSupply voltage
(current consumption 40mA or less at 24V supply voltage)
(current consumption 25mA or less at 24V supply voltage)
Maximum sink current: 100mA (Note 1)
(between output and 0V)
[at 100mA (Note 1) sink current]
Light-ON or Dark-ON, selectable with jog switchOutput operation
H-SP: 35Ǵs or less, FAST: 150Ǵs or less, S-D: 250Ǵsorless,
STD: 250Ǵs or less, LONG: 2ms or less selectable with jog switch
2-level teaching / Limit teaching / Full-auto teaching /
Manual adjustment
-10to+55 (If 4 to 7 units are connected in cascade: -10 to +50,
if 8 to 16 units are connected in cascade: -10 to +45)
(No dew condensation or icing allowed), Storage: -20 to +70
CN-73-C5 (cable length 5m)
CN-71-C5 (cable length 5m)
4 digit red LED displayDigital display
35 to 85% RH, Storage: 35 to 85% RHAmbient humidity
Red LED (modulated)Emitting element
<PNP output type>
PNP open-collector transistor
Applied voltage: 30V DC or less
Residual voltage: 1.5V or less
Incorporated
Incorporated
20g approx.Weight
PNP outputType
Maximum source current: 100mA (Note 1)
(between output and +V)
[at 100mA (Note 1) source current]
ԙ
Ԙ
Ԙ
Fiber
lock lever
Ԙ
Ԛ
ԙ
Fiber
35mm width DIN rail
ԙ
3
CONNECTION
Make sure that the power supply is off while connecting or disconnecting the quickconnection cable.
Connection method
ԘԙHolding the connector of the quick-connection cable, align
its projection with the groove at the top portion of the
Groove
Projection
amplifier connector.
Insert the connector till a click is felt.
Disconnection method
Ԙ Pressing the projection at the top of the quick-connection
cable, pull out the connector.
Take care that if the connector is pulled out without pressing the
Note:
projection, the projection may break. Do not use a quickconnection cable whose projection has broken. Further, do not pull
by holding the cable, as this can cause a cable-break.
4
CAUTIONS
٨
This product has been developed / produced for industrial use only.
٨
This product does not incorporate the optical communication function (copy
Quick-connection cable
Projection
function and interference prevention function).
٨
When the emission halt of the emitting power switching function is set from 'OFF' to
'ON', the output may be unstable. Do not use the output control for 0.5 sec. after
starting emission.
٨
Make sure that the power supply is off while wiring.
٨
Verify that the supply voltage variation is within the rating.
٨
Take care that if a voltage exceeding the rated range is applied, or if an AC power
supply is directly connected, the sensor may get burnt or damaged.
٨
In case noise generating equipment (switching regulator, inverter motor, etc.) is
used in the vicinity of this product, connect the frame ground (F.G.) terminal of the
equipment to an actual ground.
٨
If power is supplied from a commercial switching regulator, ensure that the frame
ground (F.G.) terminal of the power supply is connected to an actual ground.
٨
Do not use during the initial transient time (0.5 sec.) after the power supply is
switched on.
٨
Take care that short-circuit of the load or wrong wiring may burn or damage the
sensor.
٨
Do not run the wires together with high-voltage lines or power lines or put them in
the same raceway. This can cause malfunction due to induction.
٨
Make sure to use the optional quick-connection cable for connection of the amplifier.
٨
Extension up to total 100m (if 5 to 8 units are connected in cascade: 50m, if 9 to 16
units are connected in cascade: 20m) is possible with 0.3mm
2
, or more, cable.
However, in order to reduce noise, make the wiring as short as possible.
٨
Take care that cable extension increases the residual voltage.
٨
This sensor is suitable for indoor use only.
٨
Avoid dust, dirt, and steam.
٨
Take care that the product does not come in contact with water, oil, grease,
organic solvents, such as, thinner, etc., strong acid or alkaline.
٨
This sensor cannot be used in an environment containing inflammable or explosive
gases.
٨
Never disassemble or modify the sensor.
5
CASCADING
٨
Make sure that the power supply is off while adding or removing the amplifiers.
٨
Make sure to check the allowable ambient temperature, as it depends on the number of amplifiers connected in cascade.
٨
In case two, or more, amplifiers are connected in cascade, make sure to mount
them on a DIN rail.
٨
When the amplifiers move on the DIN rail depending on the attaching condition or
the amplifiers are mounted close to each other in cascade, fit them between the
optional end plates (MS-DIN-E) mounted at the two ends.
Up to maximum 15 amplifiers can be added (total 16 amplifiers connected in cascade.)
٨
When connecting more than two amplifiers in cascade, use the sub cable (CN-71-Cغ)
٨
as the quick-connection cable for the second amplifier onwards.
When this sensor is used by cascading along with the other digital fiber amplifier,
٨
since the optical communication function (copy function and interference prevention function) is not incorporated, mount identical models together.
For mounting and removing the amplifier, refer to ' MOUNTING'.
Cascading method
Ԙ
Mount the amplifiers, one by one,
2
Sub cable (CN-71-Cغ)
(optional)
on the 35mm width DIN rail.
ԙ
Slide the amplifiers next to each
other, and connect the quick-connection cables.
Ԛ
Mount the optional end plates
(MS-DIN-E)
at both the ends to hold
the amplifiers between their flat sides.
Tighten the screws to fix the end
ԛ
Main cable (CN-73-Cغ)
(optional)
Slide
End plates (MS-DIN-E)
(optional)
plates.
Dismantling
Ԙ
Loosen the screws of the end plates.
Remove the end plates.
ԙ
Slide the amplifiers and remove
Ԛ
them one by one.
End plates (MS-DIN-E)
(optional)
Slide

6
I/O CIRCUIT DIAGRAMS
٨ NPN output type
Sensor circuit
Tr1
Terminal No.
D1
ZD1
Color code of quick-connection cable
(Brown) +V (Note 1)
1
100mA max.
Users' circuitInternal circuit
Load
(Note 2)
(Black) Output
3
(Blue) 0V (Note 1)
2
+
12 to 24V DC
r10%
-
Terminal arrangement diagram
1
+V
3
Output
2
0V
٨ PNP output type
Terminal No.
ZD2
Tr2
Sensor circuit
D2
Notes: 1)2)The quick-connection sub cable does not have +V (brown) and 0V (blue).
The power is supplied from the connector of the main cable.
50mA max., if five, or more, amplifiers are connected in cascade.
Color code of quick-connection cable
(Brown) +V (Note 1)
1
100mA max.
3
(Black) Output
2
(Blue) 0V (Note 1)
Users' circuitInternal circuit
(Note 2)
Load
+
12 to 24V DC
r10%
-
Terminal arrangement diagram
1
+V
3
Output
2
0V
Symbols...D1,D2: Reverse supply polarity protection diode
Z
D1,ZD2: Surge absorption zener diode
T
r1: NPN output transistor
Tr
2: PNP output transistor
7
PART DESCRIPTION
Operation indicator (Orange)
MODE indicator / RUN (Green)
MODE indicator / TEACH (Yellow)
MODE indicator / ADJ (Yellow)
8
OPERATION PROCEDURE
Stability indicator
(Green)
Digital display (Red)
MODE indicator / L/D ON (Yellow)
MODE indicator / TIMER (Yellow)
MODE indicator /
PRO (Yellow)
Jog switch
MODE key
٨ When the power supply is switched on, MODE indicator /
RUN (green) lights up and the digital display shows the
incident light intensity.
MODE key
Press Press
*1:
When Jog switch is pressed, the setting is confirmed.
When MODE key is pressed for 2 sec., or more, the sensor returns to the 'RUN' mode.
*2:
Cancellation is possible by pressing MODE key during setting.
*3:
When Jog switch is turned in the 'RUN' mode, the current threshold value is displayed.
*4:
Jog switch
6WTP
'+' side '-' side
And then, the current incident light intensity display appears again automatically.
٨ NAVI mode
This indicates normal sensing operation.
Sets the threshold value by, '2-level teaching', 'limit
teaching' or 'full-auto teaching'.
Allows fine adjustment of the threshold value.
Sets output operation either Light-ON, or Dark-ON.
Configures operation of the timer.
Allows various detailed settings to be configured,
such as save/load and other settings.
RunRUN
Press
TeachingTEACH
Press
AdjustADJ
Press
L-ON/D-ONL/D
Press
TimerTIMER
Press
ProPRO
Press
9
Refer to ' TEACHING MODE'.
10
Refer to ' THRESHOLD VALUE FINE
ADJUSTMENT MODE'.
11
Refer to ' OUTPUT OPERATION
SETTING MODE'.
12
Refer to ' TIMER OPERATION
SETTING MODE'.
13
Refer to ' PRO MODE'.
To PRO mode
٨
Press
٨ PRO mode
PRO1
Response time change function
Timer setting function ''
Hysteresis function ''
PRO2
Digital display setting function ''
Digital display inversion function ''
ECO mode setting function ''
PRO3 (Note)
Data bank load setting function ''
Data bank save setting function ''
PRO4
PRO4 (Note)
Data bank load setting function ''
Data bank save setting function ''
PRO5
Turn
Code setting function ''
Adjust lock setting function
''
The functions in PRO3 mode and PRO4 mode are the same.Note:
''
Stability function ''
Shift function ''
Emitting power selection function
Turn
Turn
Turn
Turn
Setting reset function ''
''
13
Refer to ' PRO
MODE PRO1
mode setting'.
13
Refer to ' PRO
MODE PRO2
mode setting'.
13
Refer to ' PRO
MODE PRO3
mode setting'.
13
Refer to ' PRO
MODE PRO4
mode setting'.
13
Refer to ' PRO
MODE PRO5
mode setting'.
The 0-ADJ setting function in this product was removed from production starting May, 2005.
9
TEACHING MODE
In case of 2-level teaching
This is the method of setting the threshold value by teaching two levels, corre-
٨
sponding to t he object present and object absent conditions. Normally, setting is
done by this method.
Step
Display Description
Set the fiber within the sensing range.
Ԙ
ԙ
Ԛ
ԛ
Ԝ
ԝ
Press MODE key to light up MODE indicator /
TEACH (yellow).
Press Jog switch in the object present condition.
If the teaching is accepted, the read incident light intensity
blinks in the digital display.
The MODE indicator / TEACH (yellow) blinks.
Press Jog switch in the object absent condition.
If the teaching is accepted, the read incident light intensity blinks in the digi-
tal display and the threshold value is set at the mid-value between the incident light intensities in the object present and the object absent conditions.
After this, the judgment on the stability of sensing is displayed.
In case stable sensing is possible: '㵘㵘㵘㵘' is displayed.
In case stable sensing is not possible: '㵘㵘㵘㵘' is displayed.
The threshold value is displayed.
The incident light intensity appears in the digital display and the setting is complete.
Press
Press
Press
In case of limit teaching
٨
This is the method of setting the threshold value by teaching only the object
absent condition (stable incident light condition). This is used for detection in the
presence of a background body or for detection of small objects.
Step
Display Description
Set the fiber within the sensing range.
Ԙ
ԙ
Ԛ
ԛ
Ԝ
ԝ
Ԟ
Note:
The approx. 15% amount of shift is the initial value. The amount of shift can be changed in the
PRO mode from approx. 0 to 80% (5% step). Refer to ' PRO MODE / PRO1 mode setting'
for the setting method.
Press MODE key to light up MODE indicator /
TEACH (yellow).
Press Jog switch in the object absent condition.
If the teaching is accepted, the read incident light intensity
blinks in the display.
The MODE indicator / TEACH (yellow) blinks.
Turn Jog switch to the '+' side or the '-' side.
If Jog switch is turned to the '+' side, ' ' scrolls (twice) the
display from right to left, and the threshold level is shifted to a
value approx. 15% higher (lower sensitivity) than that set at ԙ.
(Note) This is used in case of reflective type fibers.
If Jog switch is turned to the '-' side, ' ' scrolls (twice) the
display from left to right, and the threshold level is shifted to a
value approx. 15% lower (higher sensitivity) than that set at ԙ.
(Note) This is used in case of thru-beam type fibers.
After this, the judgment on whether the set shift amount is possible or not will be displayed.
When the shift is possible: ' ' is displayed.
When the is not possible: ' ' is displayed.
The threshold value is displayed.
The incident light intensity appears in the digital display and the setting is complete.
High
Sensitivity
level
Low
100%
OFF
ON
OFF
Turn to '+' side
13
Sensitivity level
Sensitivity level
with object absent
Sensitivity level
15%
15%
ON
0
Turn to '-' side
Press
Press
Turn
Turn to '+' side
Turn to '-' side