Panasonic FV-08VK3 User Manual

Page 1
Model No.
Panasonic
Ventilating Fan
INSTALLATION
INSTRUCTIONS
FV-13VKM3 FV-08VKM3
FV-13VKS3 FV-13VK3 FV-08VKS3 FV-08VK3
FV-05VK3
Thank you very much for having purchased our Ventilating Fan.
Please read these instructions carefully before attempting to install, operate or service the Panasonic Ventilating Fan. Failure to comply with instructions could result in personal injury and/or property damage. Please retain this booklet for future reference
Table of Contents
Please Read Prior To Installing This Fan .................................................................................. 2
Unpacking..................................................................................................................................... 3
Supplied Accessories.................................................................................................................. 3
Description.................................................................................................................................... 3
General Safety Information......................................................................................................... 4
Dimensions................................................................................................................................... 5
Wiring Diagram.............................................................................................................................. 5
Switch Indication........................................................................................................................... 6
Operation...................................................................................................................................... 6
Installation I (Joist Mounting -1)................................................................................................. 7-9
Installation ll (Suspension Brackets Mounting) ........................................................................ 10
Installation III (Joist Mounting - II)............................................................................................... 11
Maintenance (Cleaning)............................................................................................................... 11
Practical Guide To Installation...................................................................................... Backcover
Specifications.................................................................................................................. Backcover
Product Service............................................................................................................... Backcover
PDF created with pdfFactory Pro trial version www. pdffactory. com
Page 2
PLEASE READ PRIOR TO INSTALLING THIS FAN_______________
[For models of: FV-13VKM3, FV-08VKM3, FV-13VKS3, FV-08VKS3.] The WhisperGreen line of ventilating fans employs state of the art technology providing a number of
unique features that lead to improved indoor air quality. These features need to be fully understood prior to installation to full realize the benefits fans offer.
Spot and Continuous Ventilation: These fans are designed to run continuously ensuring a healthy environment at low CFM levels 24 hours a day. By utilizing CustomVent Variable Speed Control the fans are built to run continuously at a pre-set lower level (FV-13VKM3 and FV-13VKS3:0,50,70,90, 110 CFM ; FV-08VKM3 and FV-08VKS3:0,30,40,50,60,70 CFM). The setting is dependent on the size of
the room and the individual wishes of the homeowner. It is crucial that the installer pre-set the lower setting during the installation. Please refer to the chart below and page 5 of the installation instructions.
CustomVent Variable Speed Control (Lower Setting).
ASHRAE 62.2-2007
(sq.feet) <1,000 33 40 48 55
1,500 38 45 53 60
Two Bedrooms Three Bedrooms Four Bedrooms Five Bedrooms
2,000 43 50 58 65
2,500 48 55 63 70
3,000 53 60 68
3,500 4,000 63 4,500
5,000
5,500
6,000
6,500
7,000
These fans are also built to take care of the homeowner's spot ventilation needs when the room is occupied. This models kick-up to a maximum level of 130 CFM for the FV-13VKM3 and FV-13VKS3
and 80CFM for the FV-08VKM3 and FV-08VKS3 either when the switch is turned on (available with FV-13VKS3 and FV-08VKS3) or activated by the SmartAction Motion Sensor (available with
FV-13VKM3 and FV-08VKM3). A High / Low Delay Timer, located inside the fan unit, is utilized to return the fan back to the pre-set
Continuous ventilation mode. The installer needs to consult with the homeowner for the desired setting on the timer (0.5 - 60 minutes) and make the adjustments during the installation.
58 65 73
70
78
68 75 83
73 80 88 78 85 93 83
90
98
88 95 103
93 100 108
75 80 85 90 95
100
105
110
-
Optimum Ventilation Performance: Generally duct length, elbows and other factors increase static pressure hindering the performance of most ventilation fans. This fan utilize SmartFlow microchip technology that monitors the static pressure in the system and speeds up or slows down the rpm of the fan depending on the amount of resistance. This allows the fan to perform as rated, whether facing
0.1,0.2 or even 0.25 inches water gauge. The bottom line is that it makes for easier installation. The installer no longer has to worry about compromising the fan's performance.
Outstanding Energy Savings: These fans are the very first to be built using DC motor technology. The new DC motor is 30% - 70% more energy efficient than the minimum ENERGY STAR requirements.
PDF created with pdfFactory Pro trial version www. pdffactory. com
Page 3

UNPACKING

Unpack and carefully remove the unit from carton. Refer to the Supplied Accessories list to verify that all parts are present.

SUPPLIED ACCESSORIES

Part name
Grille
Suspension bracket I
Suspension bracket II
Suspension bracket III
Suspension
bracket IV
Appearance
For models of: FV-13VKM3 FV-08VKM3
For models of: FV-13VKS3 FV-08VKS3 FV-13VK3 FV-08VK3 FV-05VK3
Quantity
Part name
Screw I
(ST4.2X6)
Screw II
(ST4.2X14)
Long screw
(ST4.2X20)
Installation
instructions
Warranty
sheet
Appearance
Quantity
2
1
6
2
1

DESCRIPTION

These Panasonic ventilating fan models are listed by UL under UL file No. E78414. These Panasonic ventilating fan models use a sirocco fan driven by a DC motor powered by an integral transformer. The motor is designed to have long operating life, high dynamic response, higher speed ranges with saving energy. The grille covering the fan body is a spring-loaded, quick remove type. A damper for preventing air counter flow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level.
Panasonic ventilating fan models FV-13VKM3 and FV-08VKM3 are equipped with a motion sensor that
shifts the fan to high flow automatically when motion is detected. It is user-adjustable to operate
0.5~60 minutes after motion is no longer detected.
PDF created with pdfFactory Pro trial version www. pdffactory. com
Page 4

GENERAL SAFETY INFORMATION

1. Do not install this ventilating fan where interior room temperature may exceed
104"F(40°C).
2. Make sure that the electric service supply voltage is AC 120V, 60Hz.
3. Follow all local electrical and safety codes, as well as the National Electrical Code
(NEC) and the Occupation Safety and Flealth Act (OSHA).
4. Always disconnect the power source before working on or near the fan, motor,
light fixture or junction box.
5. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or
other objects.
6. Do not kink the power cord.
7. Do not install the unit where ducts are configured as shown in Fig. A.
8. Provide make up air for proper ventilation.
CAUTION:
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. Not for use in cooking area. (Fig.B)
3. This product must be properly grounded.
Prohibited
Fig. A
(Cooking area)
Do not instaii above or
inside this area
—■ ■—
Cooking
Fig. B
\
/
/
\
equipment
Floor
_____
WARNING:
To reduce the risk of fire, electric shock or injury to persons, observe the following:
1. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact to
the manufacturer.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit lnterrupter)-protected branch circuit.
8. These models are UL listed for tub and shower enclosures.
9. Not to be installed in a ceiling thermally insulated to a value greater than R40.(This is required for installation in Canada only)
10. Do not use this fan with any solid-state speed control device. Solid state controls may cause harmonic
distortion which can cause motor humming noise.
11. A statement to the effect that when the product is to no longer be used, it must not be left in
place but removed, to prevent it from possibly falling.
PDF created with pdfFactory Pro trial version www. pdffactory. com
Page 5

DIMENSIONS

FV-13VKM3 FV-08VKM3
(The dimensions in square brackets refer to 13 modeis which are different from 08 and 05 modeis)
No.
1
2
3 4
5

WIRING DIAGRAM

FV-13VKM3 FV-08VKM3
Fan body Junction box
FV-13VK3 FV-08VK3 FV-05VK3
Part name
Blade Grille
Sensor unit
(FV-13VKM3,FV-08VKM3 only)
Junction box Adaptor
(Power supply)
||-^|(VE|VrT.)AC120V60Hz
...„..-Live
Switch box
No.
6
7
8
9
10
Part name
Switch unit
(FV-13VKM3, FV-08VKM3 FV-13VKS3, FV-08VKS3 only)
Fan body Damper
Suspension bracket Bracket cover
FV-13VKS3 FV-08VKS3
PDF created with pdfFactory Pro trial version www. pdffactory. com
Page 6

SWITCH INDICATION

FV-13VKM3
FV-13VKS3
FV-08VKM3 FV-08VKS3
Low speed air volume preset switch
Switch indications Switch indications
on blower unit on blower unit
Low speed air-volume preset switch positions
FV-13VKM3 FV-13VKS3
FV-08VKM3 FV-08VKS3
Air volume
[CFM]
0 50 70 90
0 30
40
50 60 70
Factory setting : FV-13VKM3/FV-13VKS3: 70CFM; FV-08VKM3/FV-08VKS3: 50CFM. Position "0" : Fan stop.
Position : use for factory test only. High/Low delay time preset switch positions
Delay Time
[min]
0.5 1
2
3 5
10
Factory setting : 20 minutes. Position : use for factory test only.
(Models of FV-13VK3 and FV-08VK3 and FV-05VK3 have only one steady air volume.)
High/Low delay time preset switch
110
20
30 60
OPERATION________________________________
■ Sensor detectible range (For models of FV-13VKM3 and FV-08VKM3 only)
The distance that motion can be detected is limited to 10 feet (3m). The field of view of the sensor is 90". (Room temperature is 25”C)
Motion
> The low speed is determined by air volume preset switch. > The delay time is determined by High/Low delay time preset switch. >The unit maintains the higher speed for an adjustable duration of 0.5 to 60 minutes, after motion
is no longer detected.
mm
IS >>
moo
il
Human active
Fan active
a
I/Ì
Z
At low speed
$0 il^
when motion is
detected, fan runs at the high speed.
Remains running at high speed until the delay time has passed.
(Models of FV-13VK3 and FV-08VK3 and FV-05VK3 have only one steady air volume, when the power switch is closed, FV-13VK3 works steadily at 130CFM and FV-08VK3 works steadily at 80CFM and FV-05VK3
works at 50 CFM, when the power switch is opened, it will stop running.)
mm
il
Human
active
Fan active
![fe
When manual wall switch Is closed,
At low
fan runs at the high
speed
speed.
When manual wall
switch is opened. Fan remains running at high speed until
the delay time has
passed.
PDF created with pdfFactory Pro trial version www. pdffactory. com
Page 7
INSTALLATION I (JOIST MOUNTING -1)
Joist situation:
A
y\
Spacing A is 16 inches (406 mm) to 24 inches (609 mm) on center joists
1. If the spacing A is 16 inches (406 mm) to 24 inches (609 mm) on center joists, please follow the installation step as below.
Joists
I I
2. Insert the suspension bracket i and ii into the fan body. (Select the suspension bracket connection holes as shown below) (Fig.1)
Suspension bracket connect method:
Suspension bracket I and II connect with screw I as shown below:
Unit: Inches (mm)
Suspension bracket II
3. Install the suspension bracket and the flange
of fan body to joists by using long screws
(ST4.2X20) and secure it to the fan body by using screw II (ST4.2X14). (Fig.2)
13 1/4 -15 1/2 (336-394) 16 1/2 -18 3/4(419-480)
21 1/4 -23 1/2(540-597)
Screw I
^ (ST4.2X6)
‘ . bracket l
Suspension
PDF created with pdfFactory Pro trial version www. pdffactory. com
Page 8
INSTALLATION I (JOIST MOUNTING - I) CONTINUED
4. Install a circular duct and secure it with clamps or wire
ties and seal it with mastic or approved duct tape.
(Fig.3)
5. Remove junction box cover and secure conduit or
stress relief to junction box knock-out hole. (Fig.3)
6. Refer to wiring diagram below.
Follow all the local electrical safety codes as well as
the National Electrical Code (NEC).
Using UL approved wire nuts, connect house power
wires to ventilating fan wires. (Fig.4-1, Fig.4-2)

CAUTION:

Mount junction box cover carefully so that lead
wires are not pinched.

Note:

Wiring detail please refer to the wiring
diagram on page5.
PDF created with pdfFactory Pro trial version www. pdffactory. com
Page 9
INSTALLATION I (JOIST MOUNTING - I) CONTINUED
7. Finish ceiling work. Ceiling hole should be aligned
with the inside edges of the flange. (Fig.5)
IMPORTANT: Remove the tapes from louver and springs
before installation. As shown below:
Tap«__w<6txX.
FV-13VKM3 FV-08VKM3
FV-13VKS3 FV-08VKS3 FV-13VK3 FV-08VK3 FV-05VK3
8. Insert the sensor unit into slot of the grille;
Fix the lead wire of sensor unit into the clasps (3 positions). (FV-13VKM3 and FV-08VKM3). (Fig.6)
9. Adjust high / low delay time preset switch and low
speed air volume preset switch (Fig.7).
Refer to switch indication on page 6. (FV-13VKM3, FV-08VKM3, FV-13VKS3 and FV-08VKS3)
CAUTION:
Mount grille carefully so that lead wire of sensor unit is not pinched.
Fig.7
10. Insert the mounting springs into the slot as
shown and mount grille to fan body. (Fig.8)
PDF created with pdfFactory Pro trial version www. pdffactory. com
Page 10
INSTALLATION E (SUSPENSION BRACKETS MOUNTING)
Joist situation:
Spacing A is 16 inches (406 mm) to 24 inches (609 mm) on center joists
1. If the spacing A is 16 inches (406 mm) to 24 inches (609 mm) on center joists, please follow the installation step as below.
Suspension bracket in
2. Insert the suspension bracket I and II into the fan body and suspension bracket III or IV into the
adaptor. (Select the suspension bracket connection holes as shown below) (Fig.9, Fig.10)
Suspension bracket connect method:
Suspension bracket I and ii connect with screw I as shown below:
16 inches (406 mm) or
19 inches (483 mm) horizentai joist Suspension bracket IV 24 inches (609 mm) horizentai joist
Joists
Unit: inches (mm)
Suspension bracket II '
13 1/4-15 1/2(336-394) 161/2 -18 3/4(419-480)
21 1/4 -23 1/2 (540-597)
^ Suspension
Screw I bracket I
(ST4.2X6)
3. Install the suspension bracket to joists by using long screws (ST4.2X20) (Fig. 10) and secure it to the fan body by using screw n (ST4.2X14). (Fig.11)
4. Follow steps 4 to 10 of installation i
(page 8 and page 9) to complete the installation work.
I
0-1 (0-25.4)
Unit: inches (mm)
6 Long screws (ST4.2X20)
131/4-151/2 ( 336-394) 161/2-19 3/4(419-480) 21 1/4-23 1/2(540-597)
21/2-4 1/5 (64-107) 51/2-7 1/5 (140-183)
"
---------
1
Tb
Sensor unit (FV-13VKM3 & FV-08VKM3 oniy)
I
Fig. 10
10
PDF created with pdfFactory Pro trial version www. pdffactory. com
Page 11
INSTALLATION m (JOIST MOUNTING - II)
Joist situation:
Spacing B is
10 1/2 inches (266 mm) to
111/2 inches (292 mm)
on joists
1. If the spacing B is 10 1/2 inches (266 mm) to 11 1/2 inches (292 mm) on joists, please follow the installation step as below.
2. Secure 4 long screws (ST 4.2X20) at flange of frame. (Fig.12)
3. Follow steps 4 to 10 of installation I (page 8 and page 9)
to complete the installation work.

MAINTENANCE (CLEANING)

WARNINS:
Disconnect power source before working on unit. Routine maintenance must be done every year.
CAUTION:
1. Never use gasoline, benzene, thinner or any other
such chemicals for cleaning the ventilating fan.
2. Do not immerse motor in water when cleaning.
3. Do not soak resin parts in water over 140°F (60°C).
1. Remove grille pull down one mounting spring(no sensor lead passed). Remove sensor unit then pull down the other mounting spring. (Squeeze mounting spring and pull down carefully). (Fig.13, Fig.14)
2. Clean grille. (Don't put into hot water. Use non-abrasive
kitchen detergent, wipe dry with clean cloth) (Fig. 15)
3. The grille should be dry after cleaning.
4. Remove dust and dirt from fan body using a vacuum
cleaner. (Fig. 16)
5. Using a cloth dampened with kitchen detergent, remove
any dirt from fan body. Wipe dry with clean cloth. (Fig. 17)
6. Replace grille.
11
PDF created with pdfFactory Pro trial version www. pdffactory. com
Ceiling
Fig.16
Page 12

PRACTICAL GUIDE TO INSTALLATION

Properly insulate the area around the fan
to minimize building heat loss and gain.
(Fig.18) Loose fill or batt insulation can be placed directly over the fan housing in the attic. Panasonic fans and fan/light combination units do not create excessive heat that is
Four inch or six inch roof jack, wall cap,'
or soffit vent with backdraft damper Mechanicaiiy connect duct to termination
and seal with mastic or approved foil faced tape
2-3 ft straight run before eibow
in attic instailation, cauik box to drywaii
a common problem with recessed light
fixtures or some competitors' fan/light
combinations. Our efficient, cool-running motors and our fluorescent lamp do not create enough ambient heat to be subjected
to these limitations.
Short piece of fiexibie duct heips aiignment and absorbs sound. Ciamps pius mastic or approved foii faced tape at all flex joints
Foil tape tightly covers all metal duct joints (glue PVC joints)

SPECIFICATIONS

Specifications
Model No.
FV-13VKM3 FV-13VKS3 FV-13VK3 FV-08VKM3 FV-08VKS3 FV-08VK3
FV-05VK3
Air
direction
Exhaust
Exhaust
Exhaust
Voltage
(V)
120
120
120
Frequency
(Hz)
60 6
60
60
Duct
diameter
(inches)
4
4
Noise
(sones)
<0.3
<0.3
<0.3
HVI Certified performance based on HVI Procedures 915,916,and 920.
■ Reference specifications
Model No.
FV-13VKM3 FV-13VKS3
FV-08VKM3 FV-08VKS3
Air
direction
Exhaust 120
Exhaust
Voltage
(V)
120
Frequency
(Hz)
60 6
60
Duct
diameter
(inches)
4
Noise
(sones)
<0.3 <0.3
<0.3 <0.3 4.7
-
<0.3 5.8 <0.3 <0.3 <0.3 <0.3
-
Reference performance based on HVI Procedures 915, 916, and 920. [(*) Standby wattage.]
Power
consumption
(W)
12 657 130 10.6(4.8)
7
4.5
Power
consumption
(W)
9.1 635
6.9 623
5.5 625
0.5 (*)
5.1
4.5 754 50
4.2
3.8
0.5 (*)
Speed
(rpm)
816
754
Speed
(rpm)
630 50
-
780 70 762
755 745
-
Air volume
at 0.1 "WG
(CFM)
80 10.2(4.6)
50 10.2(4.6)
Air volume at 0.1 "WG
(CFM)
110
90 70
0 60
40 30
0
Fig.18
Weight
Ib.(kg)
Weight
Ib.(kg)
10.6(4.8)
10.2(4.6)

PRODUCT SERVICE

____________________________________
Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only.
Your product is designed and manufactured to ensure a minimum of maintenance.
Should your unit require service or parts, call Panasonic Call Center at 1-866-292-7292 (USA) or 1-800-669-5165 (Canada).