Panasonic FV-08VK3 User Manual

Model No.
Panasonic
Ventilating Fan
INSTALLATION
INSTRUCTIONS
FV-13VKM3 FV-08VKM3
FV-13VKS3 FV-13VK3 FV-08VKS3 FV-08VK3
FV-05VK3
Thank you very much for having purchased our Ventilating Fan.
Please read these instructions carefully before attempting to install, operate or service the Panasonic Ventilating Fan. Failure to comply with instructions could result in personal injury and/or property damage. Please retain this booklet for future reference
Table of Contents
Please Read Prior To Installing This Fan .................................................................................. 2
Unpacking..................................................................................................................................... 3
Supplied Accessories.................................................................................................................. 3
Description.................................................................................................................................... 3
General Safety Information......................................................................................................... 4
Dimensions................................................................................................................................... 5
Wiring Diagram.............................................................................................................................. 5
Switch Indication........................................................................................................................... 6
Operation...................................................................................................................................... 6
Installation I (Joist Mounting -1)................................................................................................. 7-9
Installation ll (Suspension Brackets Mounting) ........................................................................ 10
Installation III (Joist Mounting - II)............................................................................................... 11
Maintenance (Cleaning)............................................................................................................... 11
Practical Guide To Installation...................................................................................... Backcover
Specifications.................................................................................................................. Backcover
Product Service............................................................................................................... Backcover
PDF created with pdfFactory Pro trial version www. pdffactory. com
PLEASE READ PRIOR TO INSTALLING THIS FAN_______________
[For models of: FV-13VKM3, FV-08VKM3, FV-13VKS3, FV-08VKS3.] The WhisperGreen line of ventilating fans employs state of the art technology providing a number of
unique features that lead to improved indoor air quality. These features need to be fully understood prior to installation to full realize the benefits fans offer.
Spot and Continuous Ventilation: These fans are designed to run continuously ensuring a healthy environment at low CFM levels 24 hours a day. By utilizing CustomVent Variable Speed Control the fans are built to run continuously at a pre-set lower level (FV-13VKM3 and FV-13VKS3:0,50,70,90, 110 CFM ; FV-08VKM3 and FV-08VKS3:0,30,40,50,60,70 CFM). The setting is dependent on the size of
the room and the individual wishes of the homeowner. It is crucial that the installer pre-set the lower setting during the installation. Please refer to the chart below and page 5 of the installation instructions.
CustomVent Variable Speed Control (Lower Setting).
ASHRAE 62.2-2007
(sq.feet) <1,000 33 40 48 55
1,500 38 45 53 60
Two Bedrooms Three Bedrooms Four Bedrooms Five Bedrooms
2,000 43 50 58 65
2,500 48 55 63 70
3,000 53 60 68
3,500 4,000 63 4,500
5,000
5,500
6,000
6,500
7,000
These fans are also built to take care of the homeowner's spot ventilation needs when the room is occupied. This models kick-up to a maximum level of 130 CFM for the FV-13VKM3 and FV-13VKS3
and 80CFM for the FV-08VKM3 and FV-08VKS3 either when the switch is turned on (available with FV-13VKS3 and FV-08VKS3) or activated by the SmartAction Motion Sensor (available with
FV-13VKM3 and FV-08VKM3). A High / Low Delay Timer, located inside the fan unit, is utilized to return the fan back to the pre-set
Continuous ventilation mode. The installer needs to consult with the homeowner for the desired setting on the timer (0.5 - 60 minutes) and make the adjustments during the installation.
58 65 73
70
78
68 75 83
73 80 88 78 85 93 83
90
98
88 95 103
93 100 108
75 80 85 90 95
100
105
110
-
Optimum Ventilation Performance: Generally duct length, elbows and other factors increase static pressure hindering the performance of most ventilation fans. This fan utilize SmartFlow microchip technology that monitors the static pressure in the system and speeds up or slows down the rpm of the fan depending on the amount of resistance. This allows the fan to perform as rated, whether facing
0.1,0.2 or even 0.25 inches water gauge. The bottom line is that it makes for easier installation. The installer no longer has to worry about compromising the fan's performance.
Outstanding Energy Savings: These fans are the very first to be built using DC motor technology. The new DC motor is 30% - 70% more energy efficient than the minimum ENERGY STAR requirements.
PDF created with pdfFactory Pro trial version www. pdffactory. com

UNPACKING

Unpack and carefully remove the unit from carton. Refer to the Supplied Accessories list to verify that all parts are present.

SUPPLIED ACCESSORIES

Part name
Grille
Suspension bracket I
Suspension bracket II
Suspension bracket III
Suspension
bracket IV
Appearance
For models of: FV-13VKM3 FV-08VKM3
For models of: FV-13VKS3 FV-08VKS3 FV-13VK3 FV-08VK3 FV-05VK3
Quantity
Part name
Screw I
(ST4.2X6)
Screw II
(ST4.2X14)
Long screw
(ST4.2X20)
Installation
instructions
Warranty
sheet
Appearance
Quantity
2
1
6
2
1

DESCRIPTION

These Panasonic ventilating fan models are listed by UL under UL file No. E78414. These Panasonic ventilating fan models use a sirocco fan driven by a DC motor powered by an integral transformer. The motor is designed to have long operating life, high dynamic response, higher speed ranges with saving energy. The grille covering the fan body is a spring-loaded, quick remove type. A damper for preventing air counter flow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level.
Panasonic ventilating fan models FV-13VKM3 and FV-08VKM3 are equipped with a motion sensor that
shifts the fan to high flow automatically when motion is detected. It is user-adjustable to operate
0.5~60 minutes after motion is no longer detected.
PDF created with pdfFactory Pro trial version www. pdffactory. com

GENERAL SAFETY INFORMATION

1. Do not install this ventilating fan where interior room temperature may exceed
104"F(40°C).
2. Make sure that the electric service supply voltage is AC 120V, 60Hz.
3. Follow all local electrical and safety codes, as well as the National Electrical Code
(NEC) and the Occupation Safety and Flealth Act (OSHA).
4. Always disconnect the power source before working on or near the fan, motor,
light fixture or junction box.
5. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or
other objects.
6. Do not kink the power cord.
7. Do not install the unit where ducts are configured as shown in Fig. A.
8. Provide make up air for proper ventilation.
CAUTION:
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. Not for use in cooking area. (Fig.B)
3. This product must be properly grounded.
Prohibited
Fig. A
(Cooking area)
Do not instaii above or
inside this area
—■ ■—
Cooking
Fig. B
\
/
/
\
equipment
Floor
_____
WARNING:
To reduce the risk of fire, electric shock or injury to persons, observe the following:
1. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact to
the manufacturer.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit lnterrupter)-protected branch circuit.
8. These models are UL listed for tub and shower enclosures.
9. Not to be installed in a ceiling thermally insulated to a value greater than R40.(This is required for installation in Canada only)
10. Do not use this fan with any solid-state speed control device. Solid state controls may cause harmonic
distortion which can cause motor humming noise.
11. A statement to the effect that when the product is to no longer be used, it must not be left in
place but removed, to prevent it from possibly falling.
PDF created with pdfFactory Pro trial version www. pdffactory. com
Loading...
+ 8 hidden pages