200 100 0 100 200
0
100
200
300
400
SPECIFICATIONS
PRECAUTIONS FOR PROPER USE
SENSING CHARACTERISTICS (TYPICAL)
Parallel deviation
• The bending radius of the fiber cable must be R10mm or more.
If the fiber cable is bent at a smaller bending radius, the sensing
capability will deteriorate.
• Do not bend the fiber cable at the root of the fiber head.
• Do not install the fiber cable on a movable part.
• In order to protect the amplifier, use by keeping 150mm, or more,
of the heat-resistant fiber cable part at normal temperature.
Protect the amplifier from heat radiation or hot air.
• Keep the fiber head surface intact. If it is scratched or spoiled, the
detectability will deteriorate.
• If the fiber head surface is dirty, wipe off the dirt with a clean soft
cloth moistened with water.
(Do not use any organic solvents.)
• Do not use the fiber head surface in places where it may come in
direct contact with water. A water drop on the fiber head surface
deteriorates the sensing.
• Ensure that any strong extraneous light is not incident on the
receiving face of the fiber head.
• Do not apply excessive tensile force of the fiber cable.
(The excessive tensile force should be 19.6N or less.)
• Take care that the sensor is not directly exposed to fluorescent
lamp from a rapid-starter lamp or a high frequency lighting device,
as it may affect the sensing performance.
• Avoid dust, dirt, and steam.
• Take care that the sensor does not come in direct contact with
water, oil, grease or organic solvents, such as, thinner, etc.
• The tightening torque must not exceed the values given below.
Cautions
Type
Model No.
Item
Fiber cable length 1m
FT-H20W-M1
Fiber cable length 2m
FT-H20W-M2
Mounting
Set screw
(cup point)
M3 or less
Tightening torque
0.98Nm or less
Tightening torque
0.49Nm or less
DIMENSIONS (Unit: mm)
Tightening prohibited range
#
Fiber
head
Fiber
head
L
LONG
STD
FAST
3
Toothed lock washer "8.5
Heat & coldresistant
specifications
Ordinary
temperature
Opposing faces 7 thickness 2.4
Protective tube (PTFE)
Screw tightening face
"0.8 fiber
core bundle
1
M40.7
M2.60.45
3.5
2,000 (FT-H20W-M1: 1,000)
10
19.5
20
150
"1.6
"2.5
"4 "2.2
Applicable amplifier (Note 1)
Sensing range
Min. sensing object
Allowable bending radius
Fiber cable length
Ambient temperature
Ambient humidity
Material
Weight
Accessories
FX-301
310mm (LONG), 140mm (STD), 100mm (FAST)
"0.02mm opaque object
R10mm or more
1m 2m
60 to 200C (No dew condensation or icing allowed)
Storage: 60 to 200C (Note 2)
35 to 85% RH, Storage: 35 to 85% RH
Fiber core: Multi-component glass, Sheath: PTFE
Fiber head: Brass (Nickel plated), Plug: Polyamide
15g approx. 23g approx.
Nut: 2 Nos., Toothed lock washer: 1 No.
Notes: 1) For further details, refer to FX-301 catalog. Please contact our
office about another applicable amplifiers.
2) The ambient temperature is the value in dry condition.
In humid environment, the ambient temperature differs.
(For a high humidity of 85% RH, the ambient temperature is 0 to 40C.)
This product is not a safety sensor. Its use is not
intended or designed to protect life and prevent body
injury or property damage from dangerous parts of
machinery. It is a normal object detection sensor.
Mounting with a nut Mounting with a set screw
150mm
or more
Ambient temperature
of fiber (
60 to 200C)
(Note)
Ambient temperature of amplifier
Plug
Setting distance L (mm)
Left
Right
Center
Operating point ?(mm)
No. LCE-FTH20W-5 May, 2001
2431-1 Ushiyama-cho, Kasugai-shi, Aichi,
486-0901, Japan
Phone: +81-(0)568-33-7211
FAX: +81-(0)568-33-2631
SUNX Limited
Phone: +81-(0)568-33-7861
FAX: +81-(0)568-33-8591
Overseas Sales Dept.
Printed on 100% recycled paper PRINTED IN JAPAN
http://www.sunx.co.jp/
All information is subject to change without prior notice.