Panasonic FBA11J14L, FBA11J10M User Manual

FBA11J10M/14L
EMINEBEA.COM
FBA11J10M Allowable Ambient Temperature Range:
-40°C ~ +40°C (65%RH) (Operating)
-40°C ~ +70°C (65%RH) (Storage) (non-condensing environment)
FBA11J14L Allowable Ambient Temperature Range:
-20°C ~ +40°C (65%RH) (Operating)
-40°C ~ +70°C (65%RH) (Storage) (non-condensing environment)
inch
Units:
(mm)
ROTATION
3.54 (90)
4.45
(113)
9.5 (max.)
(90)
3.54
4.45
(113)
Housing with solid corner type are available.
1.49 (38)
.394
1.02 (10)
(26)
.374
inlet outlet
FLOW
4 –
.177
(f4.5)
1-S 2--
3-+
321
NAME PLATE
29.5
(750)
FBA11J10M Failure Rate: 10%
70,000 Hours (-30°C)
FBA11J14L Failure Rate: 10%
70,000 Hours (-10°C)
(Pa)
Ê
Ó"
°££
30
20
°äÇ
Static Pressure
10
°äÎ
Ps
0
0.5
FBA11J10M 12V
1.0 1.5
Óx
Air Flow
FBA11J14L 12V
-
1
(min
)
2000
Normal Speed
1000
3
(m
®
N
/min)
.185
Bearing: Hydro Wave Bearing
4 – (f4.7)
(106)
(f106)
4.17
(90)
4.13
3.54
3.54 (90)
4.13
(106)
OUTLET SIDE
Rated Operating Current Input Rated Max. Max. Static Noise Mass
MODEL Voltage Voltage Power Speed Air Flow Pressure
(V) (V) (A)
*1
(W)*1 (min-1)
*1
CFM
*1
(m3/min)
*1
in H2O (Pa)*1 (dB)*1 (g)
FBA11J10M 9 7.0 ~ 14.0 102 0.92 1920 36.0 1.02 .06 17.0 24.0 180
FBA11J14L 14 7.0 ~ 14.0 63 0.88 2100 39.5 1.12 .08 21.0 25.0 185
Rotation: Clockwise Airfl ow Outlet: Air Out Over Struts *1: Average Values in Free Air
Loading...