CAUTION

This filter can be used for approximately 24 hours in smoky environments. If it is used for more than approximately 24 hours, operating problems may occur.

Do not wash the smoke-cut filter with water.

Do not reuse.

Do not use the filter at high altitudes (1 400 m or more above sea level) or in places where the ambient temperature is 35 °C or higher.

Panasonic ET-SFD100 Installation Instruction

Installing the smoke-cut filter

Installation procedure

1.Turn off the main power and remove the power plug from the receptacle.

Be sure to observe the procedure “Powering off the projector” of the projector’s Operating Instructions and then remove the power plug.

2.Use a Phillips screwdriver to loosen the filter cleaning unit fixing screw at the front of the projector.

Insert your hand into the base of the air filter and pull the air filter forwards while removing the filter cleaning unit from the projector.

Filter cleaning unit

Filter cleaning unit fixing screw

3.Insert the smoke-cut filter securely into the projector as far as it will go, and then use a Phillips screwdriver to securely tighten the fixing screw.

4.Turn on the power for the projector.

Carry out the steps in “Changing the fan mode” on the next page.

Attention

The air filter must be installed before using the projector. If the projector is used without the air filter installed or if it is not inserted securely into the

projector as far as it will go, foreign particles and dust will get inside the projector and cause problems with operation.

Smoke-cut filter

Front cover

Front cover fixing screw

Note

This filter can be used for approximately 24 hours in smoky environments. If it is used for more than approximately 24 hours, operating problems may occur.

Do not wash the static electric mesh filter with water.

Do not reuse.

This filter will not remove 100 % of the smoke from the air. If the projector is used repeatedly in a smoky environment, it may require inspection or repairs.