Panasonic Econavi XE9PKUA, Econavi XE12PKUA Quick Manual

ROOM AIR CONDITIONING
June 2013
Panasonic Corporation of North America Air Conditioning Group 1690 Roberts Blvd., NW, Suite 110, Kennesaw, GA 30144 WWW.PANASONIC.COM/AIRCON
Use of the AHRI Certified™ mark indicates a manufacture's participation in the certification program. For verification of certification for individual products, go to www.ahridirectory.org
Because its products are subject to continuous improvements, Panasonic reserves the right to modify product design and specifications without notice and without incurring any obligations. ©Copyright 2013, Panasonic Air Conditioning Products.
Caution Related to Safety
Do not add or replace refrigerant other than the specified type. Manufacturer is not responsible for the damage and deterioration in safety due to usage of other refrigerant.
JUNE 2013
Quality Management System Certificate
Environmental Management System Certificate
Certified to ISO 14001: 2004
Cert. No.: MY-ER 0112
Certified to ISO 9001: 2008
Panasonic HA Air-Conditioning (M) Sdn.Bhd. Cert. No.: MY-AR 1010
Certified to ISO 14001: 2004
Panasonic HA Air-Conditioning (M) Sdn.Bhd. Cert. No.: MY-ER 0112
Certified to ISO 9001: 2008
Cert. No.: MY-AR 1010
Panasonic has employed ECONAVI (Human Detection Technology) on its air conditioner beginning in 2007 and perfected the feature since its launch. Panasonic is now introducing ECONAVI air conditioner to the US market.
ECONAVI's smart technology monitors and senses when there are people in the room and determines how much activity is occurring, then automatically adjusts the temperature setting accordingly for optimum operation.
The low activity detection mode monitors the room, decreasing cooling when there is less movement, while the absence detection feature switches to a slightly less powerful cooling mode when there is no one in the room at all.
ECONAVI with Intelligent Eco Sensors
ECONAVI in cooling mode: *The target temperature set by ECONAVI will be restored automatically to the set temperature when a new condition is detected.
ECONAVI detects human absence in the room and raises the target temperature.
Absence Detection
No one is in the room. Detects absence.
Gradually modulates cooling power by setting the new target temperature (set temp +4˚F)
DETECT CONTROL
Set Temperature
Cooling Power
Legend:
Fan Speed
1
2
5
4
+4°F
-2°F
Set Temperature
Absent
Exit Room OutLow activityEnter Room
Normal acti vity
High activi ty
3
Present
20min.
20min.
+2°F
-4°F 1 Hour
+4°F
-4°F
Max Medium FanSet Speed Set Speed Set Speed
Remark: Set temperature on remote control display remains unchanged.
Heating Power
HOW DOES ECONAVI HUMAN ACTIVITY WORK?
ECONAVI detects changes in activity levels and reduces the cooling power by adjusting set temperature.
Activity Detection
Level of activity is decreased. Detects low activity.
Reduces cooling power by setting new target temperature (set temp +2˚F)
CONTROLDETECT
Adjusts cooling and heating power to your activities.
Activity Detection
Human Activity Sensor
Reduces cooling and heating power when you are not in the room.
Absence Detection
EXTERIOS
Serving the US Ductless market since 1983
SEER
28.5
Features
Cool/Dry Mode
Heat Mode
Microprocessor control ensures that the temperature and humidity levels in the room are always comfortable.
Microprocessor-Controlled Operation
ECONAVI features intelligent Human Activity Sensor and new technologies that can detect human activity and absence, and optimize air conditioner operation according to room conditions.
ECONAVI
Panasonic’s infrared Remote Control with and easy-to-read LCD Display, gives the user the capability to adjust & set: temperature, sweep (louver control), fan speeds, timer and more, for complete automatic operation.
Wireless Remote Control
Convenient microprocessor control automatically adjusts fan speed to High, Medium or Low. According to room temperature to maintain a comfortable airflow throughout the room.
5 Fan Speeds and Automatic Fan Operation
The air sweep function moves the louver up and down in the air outlet, directing air in a “sweeping” motion around the room and providing comfort in every corner.
2 air guides
Air Sweep Control
Louver can be manually set to the desired angle by remote control.
Louver Control
After setting the temperature and functions you desire, just relax. If the room temperature is higher than the set temperature, cooling operation begins. If the room temperature is lower than the set temperature, heating operation begins. During normal thermostat cycle operation, cooling and heating operations automatically change in accordance with set temperature, time and room temperature (Single Zone Heat Pump unit only).
Automatic Heating and Cooling Changeover
The remote control unit allows you to set a wide variety of timer-based operations. Such functions include automatic ON/OFF with a timer setting, same time ON/OFF every day, ON timer, OFF timer and Combination timer.
24-hour Clock with ON/OFF Program Timer
Automatic Restart Function after Power Failure
LOW, low fan speed for extra quiet operation.
Quiet Mode
Self-Diagnosing Function
The circulation volume of the refrigerant is controlled by a pulse type electric control valve. In order to attain optimum efficiency, when the power is switched ON, the opening degree of the electric control valve is controlled between 90 and 480 step.
Electric Refrigerant Control Valve
By coupling compressor and fan operation, intermittent operation can be precisely controlled according to room temperature, so that air is efficiently dehumidified.
Dry Mode
Right from the start, air is warm and comfortable. The Hot Start Heating System prevents any cold blasts at the beginning while the heat pump is warming up (Heat pump unit only).
Hot Start Heating System
Condensers can take a beating from exposure to salty air, rain and other corrosive factors. Panasonic has extended the life of its condensers with an original anti-rust coating.
Blue Fin Condenser
Room Freeze Protection mode helps prevent plumbing damage due to sub-Freezing Temperature. This mode automatically turns on the compressor for heat pump operation if the room temperature falls to about 46°F.
*This function may not be performed if the unit is not powered, or if the unit is unable to operate such as in protection mode. Please consult with the HVAC installers.
Room Freeze Protection
Panasonic Adds a "NEW Air Conditioner" Line-up...
Setting Another Milestone in the History of Ductless Split.
No.1* High Energy Efficiency*
Breakthrough technology suc h as the inverter, enables t he highest energy efficiency* in the industry. Thanks to this exceptional performance, you can enjoy more comfort. *CS/CU-XE9PKUA as of March 2013
LOW
AMBIENT
OPERATION
SEER
28.5
Powerful Heating at Low Ambient
Inverter Technology
Heating is still possible even if the temperature drops as low as 0˚F for reliable heating in the middle of the harshest winter.
Panasonic' s inverter technology provides optimum pow er control and extrem ely efficie nt operation by changing the power supply frequency. The result is speedy, flexible operation using less electricity.
Innovative Inverter Technology
The inverter constantly adjusts the compressor rotation speed to provide optimum performance at all times. After reaching the set temperature, an inverter air conditioner continues to operate with minimum power to avoid unnecessary electricity consumption. Conventional non-inverter air conditioners can only operate at a constant speed, switching the compressor ON and OFF to maintain the set temperature, which wastes electricity.
20dB
30dB
40dB
50dB
60dB
80dB
Leaves touch together
Whisper voice
In a library
In a office
In a subway
Normal conversation
Inverter Compressor
Panasonic’s Inverter Compressor can achieve high efficiency under high load conditions.With accumulated production of 200 Million compressors, extremely high quality and reliability are proven.
High Efficiency & High Reliability Material
for longer life span and to withstand high pressure.
High Efficiency Motor
for wide operating voltage.
Optimum Shape Muffler
for quiet operation.
Indoor Unit
CS-XE9PKUA / CS-XE12PKUA
12,000Btu/h
Maximum capacity
8,700Btu/h
Rated capacity
2,800Btu/h
Minimum capacity
Even Wider Output Power Range
The graph shows CS-XE9PKUA's wide power output range during cooling.
* This is maximum elevation difference when the indoor unit is located above the outdoor unit.
*Image of output power fluctuation
Advantages of Inverter Control
Comparing inverter and non-inverter air conditioners to cars.
The accelerator can't be adjusted, so you spend a long time to get comfortable, then soon become uncomfortable.
Keeps the temperature comfortable all the time.
Adjusts the accelerator and thus runs more economically.
Reaches the comfortable zone quickly.
START
Runs at a fixed speed, so it takes longer to reach the comfort zone.
The room gets too cold, then too warm.
Uncomfortable
Comfortable
Uncomfortable
Non-inverter air conditioner
Inverter air conditioner
Cooler
Less Cool
Room temperature
Setting Temperature
Model No.
Room Freeze Protection
XE9PKUA XE12PKUA
Unit Model No.
Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
CS-XE9PKUA CU-XE9PKUA CS-XE12PKUA CU-XE12PKUA
Performance & Electrical Ratings
Capacity
Cooling Btu/h 8,700(2,800~12,000) 11,500(2,800~14,000)
Heating Btu/h 12,000(3,000~18,000) (10,600 at 17˚F) 13,800(3,000~23,000) (13,500 at 17˚F)
Moisture Removal High Pints/H 1.3 2.3
Dry Air Flow High CFM 405 530
SEER Cooling 28.5 25.5
EER Cooling 16.1 14.35
HSPF Heating 12.5 12.0
Power Supply V, Phase, Hz 230/208V, 1PH, 60Hz 230/208V, 1PH, 60Hz
Running Amps
Cooling A 2.5/2.8 3.8/4.2
Heating A 4.0/4.5 5.2/5.8
Power Input
Cooling W 540(150-850) 800(150-1,050)
Heating W 860(150-1,650) 1,150(150-2,100)
Back-up Heater kW --- ---
Fuse or Circuit Breaker
Capacity
A 15 20
Features
Controls Microprocessor Microprocessor
Low Ambient Control Equipped Equipped
Wireless Remote Controller Included Included
Wired Remote Controller (optional) CZ-RD516C CZ-RD516C
Fan Speeds 5 Speeds + Auto 5 Speeds + Auto
Timer 24hr Program 24hr Program
Air Deflection
Horizontal Manual Manual
Vertical Automatic Automatic
Air Filter Washable + Anti Microbial Filter Washable + Anti Microbial Filter
Refrigerant R-410A R-410A
Refrigerant Control Electric Expansion Valve Electric Expansion Valve
Operation Sound
In(Hi / Lo/ Q-Lo) dB-A 42 / 25 / 20 45 / 28 / 20
Outdoor(Hi) dB-A 48 49
Refrigerant Piping
Type Flare Flare
Discharge in. 1/4” 1/4”
Suction in. 3/8” 1/2”
Refrigerant Pipe Length Ft.
Max. 66 Max. 66
Elevation Difference*
Outdoor Above Ft. Max. 49 Max. 49
Outdoor Below Ft. Max. 49 Max. 49
Dimensions & Weight Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
Height in. 11-5/8” 27-3/8” 11-5/8” 27-3/8”
Width in. 34-9/32” 34-15/32” 34-9/32” 34-15/32”
Depth in. 10-1/16” 12-5/8” 10-1/16” 12-5/8”
Net Weight Lbs. 24 97 24 97
Wireless Remote Controller
Specifications
Outdoor Unit
CU-XE9PKUA CU-XE12PKUA
Special Coating Layer (Fin Cross-section)
Cool air doesn't reach you directly so your hands and feet don't get cold.
Warm feet and no direct breeze on your face mean even more comfort.
Cooling Mode
2 air guides to improve the air flow direction
Heating Mode
Water Air Salt content
Base material Corrosion-resistant layer
2 air guides
This feature allows the system to automatically resume operation at its preset program, after power is restored from a power failure when the remote control is in the room.
Unit is equipped with Self-Diagnosing Function with remote controller. This makes it easier to diagnose malfunctions, reducing service labors.
Loading...