Panasonic DMC-FP2PR, DMC-FP2P, DMC-FP1PR, DMC-FP2EE, DMC-FP1PU User Manual

...
ORDER NO. DSC1002001CE
Digital Camera
Model No. DMC-FP1P
DMC-FP1PC DMC-FP1PR DMC-FP1PU DMC-FP1EB DMC-FP1EE DMC-FP1EF
B26
DMC-FP1EG DMC-FP1EP DMC-FP1GC DMC-FP1GD DMC-FP1GF DMC-FP1GH DMC-FP1GK DMC-FP1GN DMC-FP1GT DMC-FP2P DMC-FP2PC DMC-FP2PR DMC-FP2PU DMC-FP2EB DMC-FP2EE
© Panasonic Corporation 2010 Unauthorized copy­ing and distribution is a violation of law.
Vol. 1
Colour [ DMC-FP1 ]
(S)...........Silver Type (except PC/EB/EF/GD)
(K)...........Black Type
(R)...........Red Type (only P/PC/GC)
(P)...........Pink Type (except PC/EE/GD)
(A)...........Blue Type (except PC/PR/GC/GD)
(D)...........Orange Type (only P/EB/EE/EF/EG/EP/GK)
(G)..........Green Type (only P/PU/GD/GK/GN)
(H)...........Gray Type (only P/PC)
[ DMC-FP2 ]
(S)...........Silver Type (only PU/EE/EG/EP)
(K)...........Black Type (except P/PC)
(R)...........Red Type (except PR)
(A)...........Blue Type (only P/PU/EB/EG)
(D)...........Orange Type (only P)
(G)..........Green Type (only P)
(H)...........Gray Type (only P/PC)
(PA).........Light Pink Type (except P/PC/EE/EP)
2
TABLE OF CONTENTS
PAGE PAGE
1 Safety Precautions----------------------------------------------- 4
1.1. General Guidelines---------------------------------------- 4
1.2. Leakage Current Cold Check--------------------------- 4
1.3. Leakage Current Hot Check (See Figure 1.) ------- 4
1.4. How to Discharge the Capacitor on E.Capacitor P.C.B. ---------------------------------------- 5
2 Warning-------------------------------------------------------------- 6
2.1. Prevention of Electrostatic Discharge (ESD) to Electrostatically Sensitive (ES) Devices---------- 6
2.2. How to Recycle the Lithium Ion Battery (U.S. Only)---------------------------------------------------------- 6
2.3. Caution for AC Cord(For EB/GC/GH) ---------------- 7
2.4. How to Replace the Lithium Battery ------------------ 8
3 Service Navigation----------------------------------------------- 9
3.1. Introduction-------------------------------------------------- 9
3.2. General Description About Lead Free Solder (PbF)---------------------------------------------------------- 9
3.3. Important Notice 1:(Other than U.S.A. and Canadian Market) ----------------------------------------- 9
3.4. How to Define the Model Suffix (NTSC or PAL model)-------------------------------------------------------10
4 Specifications ----------------------------------------------------14 5 Location of Controls and Components------------------15 6 Service Mode -----------------------------------------------------17
6.1. Error Code Memory Function--------------------------17
6.2. ICS (Indication of additional Camera Settings when picture was taken) function---------------------19
7 Service Fixture & Tools----------------------------------------21
7.1. Service Fixture and Tools-------------------------------21
7.2. When Replacing the Main P.C.B.---------------------22
7.3. Service Position-------------------------------------------22
8 Disassembly and Assembly Instructions ---------------23
8.1. Disassembly Flow Chart--------------------------------23
8.2. PCB Location----------------------------------------------23
8.3. Disassembly Procedure---------------------------------24
9 Measurements and Adjustments---------------------------31
9.1. Introduction-------------------------------------------------31
9.2. Before Disassembling the unit ------------------------31
9.3. Details of Electrical Adjustment-----------------------33
9.4. After Adjustment------------------------------------------36
10 Maintenance-------------------------------------------------------37
10.1. Cleaning Lens and LCD Panel------------------------37
3
1 Safety Precautions
1.1. General Guidelines
1. IMPORTANT SAFETY NOTICE There are special components used in this equipment which are important for safety. These parts are marked by
in the Schematic Diagrams, Circuit Board Layout, Exploded Views and Replacement Parts List. It is essen­tial that these critical parts should be replaced with manu­facturer’s specified parts to prevent X-RADIATION, shock, fire, or other hazards. Do not modify the original design without permission of manufacturer.
2. An Isolation Transformer should always be used during the servicing of AC Adaptor whose chassis is not isolated from the AC power line. Use a transformer of adequate power rating as this protects the technician from acci­dents resulting in personal injury from electrical shocks. It will also protect AC Adaptor from being damaged by acci­dental shorting that may occur during servicing.
3. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been over­heated or damaged by the short circuit.
4. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly installed.
5. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
1.3. Leakage Current Hot Check (See Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Connect a 1.5 kΩ, 10 W resistor, in parallel with a 0.15 μF capacitor, between each exposed metallic part on the set and a good earth ground, as shown in Figure 1.
3. Use an AC voltmeter, with 1 kΩ/V or more sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the volt­age at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the above measurements.
6. The potential at any point should not exceed 0.75 V RMS. A leakage current tester (Simpson Model 229 or equiva­lent) may be used to make the hot checks, leakage cur­rent must not exceed 1/2 mA. In case a measurement is outside of the limits specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked before it is returned to the customer.
1.2. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between the jumpered AC plug and each exposed metal­lic cabinet part on the equipment such as screwheads, connectors, control shafts, etc. When the exposed metal­lic part has a return path to the chassis, the reading should be between 1 MΩ and 5.2 MΩ. When the exposed metal does not have a return path to the chassis, the reading must be infinity.
Figure. 1
4
1.4. How to Discharge the Capacitor on E.Capacitor P.C.B.
CAUTION:
1. Be sure to discharge the capacitor on E.Capacitor P.C.B..
2. Be careful of the high voltage circuit on E.Capacitor P.C.B. when servicing.
[Discharging Procedure]
1. Refer to the disassemble procedure and remove the necessary parts/unit.
2. Install the insulation tube onto the lead part of resistor (ERG5SJ102:1kΩ /5W). (an equivalent type of resistor may be used.)
3. Place a resistor between both terminals of capacitor on the E.Capacitor P.C.B. for approx. 5 seconds.
4. After discharging, confirm that the capacitor voltage is lower than 10V using a voltmeter.
Fig. F1
5
2Warning
2.1. Prevention of Electrostatic Discharge (ESD) to Electrostatically Sensitive (ES) Devices
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called Elec­trostatically Sensitive (ES) Devices.
The following techniques should be used to help reduce the incidence of component damage caused by electrostatic discharge (ESD).
1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any ESD on your body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging ESD wrist strap, which should be removed for potential shock reasons prior to applying power to the unit under test.
2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface su ch as a lumi­num foil, to prevent electrostatic charge buildup or exposure of the assembly.
3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.
4. Use only an antistatic solder removal device. Some solder removal devices not classified as "antistatic (ESD protected)" can generate electrical charge sufficient to damage ES devices.
5. Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ES devices.
6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminum foil or compara­ble conductive material).
7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material to the chassis or circuit assembly into which the device will be installed.
CAUTION :
Be sure no power is applied to the chassis or circuit, and observe all other safety precautions.
8. Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise harmless motion such as the brushing together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity (ESD) suf­ficient to damage an ES device).
2.2. How to Recycle the Lithium Ion Battery (U.S. Only)
6
2.3. Caution for AC Cord (For EB/GC/GH)
2.3.1. Information for Your Safety
IMPORTANT
Your attention is drawn to the fact that recording of pre­recorded tapes or discs or other published or broadcast material may infringe copyright laws.
WARNING
To reduce the risk of fire or shock hazard, do not expose this equipment to rain or moisture.
CAUTION
To reduce the risk of fire or shock hazard and annoying interference, use the recommended accessories only.
FOR YOUR SAFETY
DO NOT REMOVE THE OUTER COVER
To prevent electric shock, do not remove the cover. No user serviceable parts inside. Refer servicing to qualified service personnel.
2.3.2. Caution for AC Mains Lead
For your safety, please read the following text carefully.
This appliance is supplied with a moulded three-pin mains plug for your safety and convenience. A 5-ampere fuse is fitted in this plug. Should the fuse need to be replaced please ensure that the replacement fuse has a rating of 5 amperes and it is approved by ASTA or BSI to BS1362 Check for the ASTA mark or the BSI mark on the body of the fuse.
2.3.2.1. Important
The wires in this mains lead are coloured in accordance with the following code:
Blue Neutral Brown Live
As the colours of the wires in the mains lead of this applianc e may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
The wire which is coloured BLUE must be connected to the ter­minal in the plug which is marked with the letter N or coloured BLACK.
The wire which is coloured BROWN must be connected to the terminal in the plug which is marked with the letter L or coloured RED.
Under no circumstances should either of these wi res be con­nected to the earth terminal of the three pin plug, marked with the letter E or the Earth Symbol.
2.3.2.2. Before Use
Remove the Connector Cover as follows.
If the plug contains a removable fuse cover you must ensure that it is refitted when the fuse is replaced. If you lose the fuse cover, the plug must not be used until a replacement cover is obtained. A replacement fuse cover can be purchased from your local Panasonic Dealer.
If the fitted moulded plug is unsuitable for the socket outlet in your home then the fuse should be removed and the plug cut off and disposed of safety. There is a danger of severe electrical shock if the cut off plug is inserted into any 13-ampere socket.
If a new plug is to be fitted please observe the wiring code as shown below. If in any doubt, please consult a qualified electrician.
2.3.2.3. How to Replace the Fuse
1. Remove the Fuse Cover with a screwdriver.
2. Replace the fuse and attach the Fuse cover.
7
2.4. How to Replace the Lithium Battery
2.4.1. Replacement Procedure
1. Remove the MAIN P.C.B.. (Refer to Disassembly Procedures.)
2. Unsolder the each soldering point of electric l ead terminal for Lithium battery (Ref. No. “B9101” at component side of MAIN P.C.B.) and remove the Lithium battery together with electric lead terminal. Then replace it into new one.
NOTE:
The Type No. ML421 includes electric lead terminals.
NOTE:
This Lithium battery is a critical component. (Type No.: ML421 Manufactured by Energy Company, Panaso nic Corporation.) It must never be subjected to excessive heat or discharge. It must therefore only be fitted in requirement designed specifically for its use. Replacement batteries must be of same type and manufacture. They must be fitted in the same manner and location as the original battery, with the correct polarity contacts observed. Do not attempt to re-charge the old battery or re-use it for any other purpose. It should be disposed of in waste products destined for burial rather than incineration.
NOTE:
Above caution is applicable for a battery pack which is for DMC-FP1,FP2 series, as well.
8
3 Service Navigation
3.1. Introduction
This service manual contains technical information, which allow service personnel’s to understand and service this model. Please place orders using the parts list and not the drawing reference numbers. If the circuit is changed or modified, the information will be followed by service manual to be controlled with original service manual.
3.2. General Description About Lead Free Solder (PbF)
The lead free solder has been used in the mounting proce ss of a ll electrical components on the printed circuit board s used for this equipment in considering the globally environmental conservation. The normal solder is the alloy of tin (Sn) and lead (Pb). On the other hand, the lead free solder is the alloy mainly consists of tin (Sn), silver (Ag) and Copper (Cu), and the melting point of the lead free solder is higher approx.30°C (86°F) more than that of the normal solder.
Distinction of P.C.B. Lead Free Solder being used
Service caution for repair work using Lead Free Solder (PbF)
• The lead free solder has to be used when repairing the equipment for which the lead free solder is used. (Definition: The letter of “PbF” is printed on the P.C.B. using the lead free solder.)
• To put lead free solder, it should be well molten and mixed with the original lead free solder.
• Remove the remaining lead free solder on the P.C.B. cleanly for sold ering of the new IC.
• S ince the melting point of the lead free solder is higher tha n that of the normal lead solder, it takes the longer time to melt the lead free solder.
• Use the soldering iron (more than 70W) equipped with the temperature control after setting the temperature at 350±30°C (662±86°F).
Recommended Lead Free Solder (Service Parts Route.)
• The following 3 types of lead free solder are available through the service parts route. RFKZ03D01KS-----------(0.3mm 100g Reel) RFKZ06D01KS-----------(0.6mm 100g Reel) RFKZ10D01KS-----------(1.0mm 100g Reel)
Note
* Ingredient: tin (Sn) 96.5%, silver (Ag) 3.0%, Copper (Cu) 0.5%, Cobalt (Co) / Germanium (Ge) 0.1 to 0.3%
3.3. Important Notice 1:(Other than U.S.A. and Canadian Market)
1. The service manual does not contain the following information because of issues servicing to component level without neces­sary equipment/facilities.
a. Schematic diagram, Block Diagram and P.C.B. layout of MAIN P.C.B. and SUB OPERATION P.C.B..
b. Parts list for individual parts for MAIN P.C.B. and SUB OPERATION P.C.B.. When a part replacement is required for repairing MAIN P.C.B. and/or SUB OPERATION P.C.B., replace as an assembled parts. (MAIN P.C.B. / SUB OPERATION P.C.B.)
2. The following category is/are recycle module part. please send it/them to Central Repair Center.
• MAIN P.C.B. (DMC-FP1: VEP56095B, DMC-FP2: VEP56095C)
• SUB OPERATION P.C.B. (VEP59074A)
9
3.4. How to Define the Model Suffix (NTSC or PAL model)
There are nine kinds of DMC-FP1/FP2, regardless of the colours.
• a) DMC-FP1 (Japan domestic model)
• b) DMC-FP1P/PC, FP2P/PC
• c) DMC-FP1EB/EF/EG/EP, FP2EB/EF/EG/EP
• d) DMC-FP1EE, FP2EE
• e) DMC-FP1GT
• f) DMC-FP1GK
• g) DMC-FP1GD
• h) DMC-FP1GN
• i) DMC-FP1PU/PR/GC/GF/GH, FP2PU/PR
What is the difference is that the “INITIAL SETTINGS” data which is stored in Flash-ROM mounted on MAIN P.C.B..
3.4.1. Defining methods:
To define the model suffix to be serviced, refer to the nameplate which is putted on the bottom side of the Unit.
NOTE:
After replacing the MAIN P.C.B., be sure to achieve adjustment. The adjustment instruction is available at “software download” on the “Support Information from NWBG/VDBG-AVC” web-site in “TSN system”, together with Maintenance software.
10
3.4.2. INITIAL SETTINGS:
After replacing the MAIN P.C.B., be sure to perform the initial settings after achieving the adjustment by or dering the fo llowi ng pro­cedure in accordance with model suffix of the unit.
1. IMPORTANT NOTICE:
Before proceeding Initial settings, be sure to read the following CAUTIONS.
2. PROCEDURES:
• P recautions: Read the above "CAUTION 1" and "CAUTION 2", carefully.
• Preparation:
1. Attach the Battery or AC Adaptor with a DC coupler to the unit. (Since this unit has built-in memory, it can be performed without inserting SD memory card.)
2. Set the recording mode to the [ NORMAL PICTURE ] mode. (Press the [ MODE ] button and select the [ NORMAL PICTURE ] by pressing the “[ UP ] and [ DOWN ] of Cursor buttons”, then press the [ MENU/SET ] button.)
NOTE:
If the unit is other than [ NORMAL PICTURE ] mode, it does not display the initial settings menu.
Step 1. The temporary cancellation of “INITIAL SETTINGS”: While keep pressing “[ UP ] of Cursor button” and [ iA ] button simultaneously, turn the Power on.
Step 2. The cancellation of “INITIAL SETTINGS”: Press the [ PLA YBACK ] button to “Playback Mode”. Press “[ UP ] of Cursor button” and [ iA ] button simultaneously, then turn the Power off.
Step 3. Turn the Power on: Turn the Power on.
Step 4. Display the INITIAL SETTING: While keep pressing [ MENU/SET ] and “[ RIGHT ] of Cursor buttons” simultaneously, turn the Power off. The "INITIAL SETTINGS" menu is displayed. There are two kinds of “INITIAL SETTINGS” menu form as follows:
11
[CASE 1. After replacing MAIN P.C.B.] When MAIN P.C.B. has just been replaced, all of the model suffix is displayed as follows. (Five pages in total)
[CASE 2. Other than “After replacing MAIN P.C.B.”]
Step 5. Choose the model suffix in “INITIAL SETTINGS”: (Refer to “CAUTION 1”)
[Caution: After replacing MAIN P.C.B.]
The model suffix can been chosen, JUST ONE TIME. Once one of the model suffix have been chosen, the model suffix lists will not be displayed, thus, it can not be changed. Therefore, select the area carefully.
Select the area with pressing “[ UP ] / [ DOWN ] of Cursor buttons”.
Step 6. Set the model suffix in “INITIAL SETTINGS”:
• Press the “[ RIGHT ] of Cursor buttons”.
• The only set area is displayed, and then press the “[ RIGHT ] of Cursor buttons” after confirmation. (The unit is powered off automatically.)
12
Step 7. CONFIRMATION: Confirm the display of “PLEASE SET THE CLOCK” in concernd language when the unit is turned on again. When the unit is connected to PC with USB cable, it is detected as removable media.
1) As for your reference, major default setting condition is as shown in the following table.
Default setting (After “INITIAL SETTINGS”)
MODEL VIDEO OUTPUT LANGUAGE DATE REMARKS a) DMC-FP1 (Japan domestic model) NTSC Japanese Year/Month/Date b) DMC-FP1/FP2P NTSC English Month/Date/Year
c) DMC-FP1/FP2EG PAL English Date/Month/Year d) DMC-FP1/FP2EP PAL English Date/Month/Year e) DMC-FP1/FP2PU NTSC English Month/Date/Year
f) DMC-FP1GD NTSC Korean Year/Month/Date g) DMC-FP1GC PAL English Date/Month/Year h) DMC-FP1GT NTSC Chinese (traditional) Year/Month/Date
i) DMC-FP1GK PAL Chinese (simplified) Year/Month/Date
j) DMC-FP1/FP2EF PAL French Date/Month/Year
k) DMC-FP1/FP2EB PAL English Date/Month/Year
l) DMC-FP1/FP2EE PAL Russian Date/Month/Year m) DMC-FP1GN PAL English Date/Month/Year n) DMC-FP1/FP2PC NTSC English Month/Date/Year o) DMC-FP1/FP2PR PAL English Date/Month/Year p) DMC-FP1GH PAL English Date/Month/Year q) DMC-FP1GF PAL English Date/Month/Year
13
4 Specifications
14
5 Location of Controls and Components
Hand strap eyelet
Cursor button
Names of parts
Zoom lever
Shutter button
Flash
Lens
Self-timer indicator/ AF assist lamp
Lens cover
Fully peel off the strip of tape from the
lens cover before using the camera.
button
When opening and closing the lens
cover, make sure that liquid or foreign objects such as sand do not enter.
Microphone
LCD monitor
[MODE] button
Cursor button
[DISPLAY] button
[Q.MENU]/delete button
Release lever
Tripod receptacle
Ensure that the tripod is stable.
Card/Battery door
We recommend you use a battery with sufficient battery power or the
Ɣ
AC adaptor when recording motion pictures.
[MENU/SET]
(menu display/set/finish)
/HIWFXUVRUEXWWRQŻ
Self-timer
'RZQFXUVRUEXWWRQź
Macro mode
Power button
Playback button
Speaker
8SFXUVRUEXWWRQŸ
Exposure compensation
5LJKWFXUVRUEXWWRQŹ
Flash
We recommend using the supplied hand strap to avoid dropping the camera.
[AV OUT/DIGITAL] socket
[DC IN] socket
Always use a genuine Panasonic AC adaptor (DMW-AC5PP: optional).
Ɣ
If while recording motion pictures using the AC adaptor the power
Ɣ
supply is cut off due to a power cut or if the AC adaptor is disconnected etc., the motion picture being recorded will not be recorded.
15
Selecting the [REC] mode
Open the lens cover
The power is turned on.
Press the [MODE] button (
)
A
A
3UHVVŸRUźWRVHOHFWWKH
recording mode
Press [MENU/SET] (
[NORMAL PICTURE] Mode
Take pictures with your own settings.
[MY SCENE MODE]
Take pictures in commonly used scene modes.
[SCENE MODE]
Take pictures according to scene.
[MOTION PICTURE] Mode
Take motion pictures.
Preparation
)
B
B
About the Battery
The camera has a function for distinguishing batteries which can be used safely. The dedicated battery supports this function. The only batteries suitable for use with this unit are genuine Panasonic products and batteries manufactured by other companies and certified by Panasonic. (Batteries which do not support this function cannot be used). Panasonic cannot in any way guarantee the quality, performance or safety of batteries which have been m Panasonic products.
It has been found that counterfeit battery packs which look very similar to the genuine product are made available to purchase in some markets. Some of these battery packs are not adequately protected with internal protection to meet the requirements of appropriate safety standards. There is a possibility that these battery packs may lead to fire or explosion. Please be advised that we are not liable for any accident or fa battery pack. To ensure that safe products are used we would recommend that a genuine Panasonic battery pack is used.
anufactured by other companies and are not genuine
ilure occurring as a result of use of a counterfeit
16