9.2.1. Parts Identification.
9.2.1.1. Vertical Airflow Direction Vane.
Airflow direction adjustment Up-and-Down.
•
The vertical airflow direction vane is
controlled by positioning the vane to
discharge the air upwards, downwards
or straight out.
9.2.1.2. Ventilation Lever.
When the slide lever is in the:
•
“OPEN” position, the ventilation door
opens to allow air, smoke or odours to be
expelled from the room.
•
“CLOSE” position, the ventilation door is
closed and the air will be circulated inside
the room and conditioned.
9.2.1.3. Recommended.
Use the air conditioner under the following conditions:
•
Operating temperature range.
Indoor side Outdoor side
D.B.T. W.B.T. D.B.T. W.B.T.
Cooling Maximum Temperature 32°C 23°C 43°C 26°C
Minimum Temperature 21°C 15°C 21°C 15°C
Heating Maximum Temperature 27°C ---- 21°C 15°C
Minimum Temperature 20°C ---- -5°C -6°C
D.B.T.: Dry Bulb Temperature
W.B.T.: Wet Bulb Temperature
Note: Humidity may exceed 90%.
− Continuous operation at humidities of over 90% may
create condensation to form on the intake and outlet
vanes.
9.2. CW-A172KR(Cooling and Heating)
13