Panasonic CS-PC12QKH, CS-PC9QKH, CS-PC18QKH, CS-PC28QKH, CU-PC9QKH Service Manual

...
© Panasonic Corporation 2013
Order No: PAPAMY1312019CE
Indoor Unit Outdoor Unit
CS-PC9QKH CS-PC12QKH CS-PC18QKH CS-PC24QKH CS-PC28QKH
Destination
Myanmar
South East Asia
North Africa
Bangladesh
This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or repair the products dealt with in this service information by anyone else could result in serious injury or death.
WARNING
2
TABLE OF CONTENTS
PAGE PAGE
1. Safety Precautions .............................................3
2. Specification .......................................................5
3. Features.............................................................15
4. Location of Controls and Components..........16
4.1 Indoor Unit ..................................................16
4.2 Outdoor Unit ...............................................16
4.3 Remote Control ..........................................16
5. Dimensions .......................................................17
5.1 Indoor Unit ..................................................17
5.2 Outdoor Unit ...............................................19
6. Refrigeration Cycle Diagram ...........................21
7. Block Diagram ..................................................22
7.1 CS-PC9QKH CU-PC9QKH CS-PC12QKH CU-PC12QKH
CS-PC18QKH CU-PC18QKH ....................22
7.2 CS-PC24QKH CU-PC24QKH ....................23
7.3 CS-PC28QKH CU-PC28QKH ....................24
8. Wiring Connection Diagram ............................25
8.1 CS-PC9QKH CU-PC9QKH
CS-PC12QKH CU-PC12QKH ....................25
8.2 CS-PC18QKH CU-PC18QKH ....................26
8.3 CS-PC24QKH CU-PC24QKH ....................27
8.4 CS-PC28QKH CU-PC28QKH ....................28
9. Electronic Circuit Diagram ..............................29
9.1 CS-PC9QKH CU-PC9QKH
CS-PC12QKH CU-PC12QKH ....................29
9.2 CS-PC18QKH CU-PC18QKH ....................30
9.3 CS-PC24QKH CU-PC24QKH ....................31
9.4 CS-PC28QKH CU-PC28QKH ...................32
10. Printed Circuit Board .......................................33
10.1 Indoor Unit ..................................................33
11. Installation Instruction.....................................38
11.1 Select the Best Location.............................38
11.2 Indoor Unit ..................................................39
11.3 Outdoor Unit ...............................................44
12. Installation Instruction.....................................48
12.1 Select the Best Location.............................48
12.2 Indoor Unit ..................................................49
12.3 Outdoor Unit ...............................................53
13. Operation Control.............................................57
13.1 Cooling Operation.......................................57
13.2 Soft Dry Operation......................................59
13.3 iAUTO Operation ........................................61
13.4 Indoor Fan Speed Control ..........................61
13.5 Outdoor Fan Speed Control .......................63
13.6 Vertical Airflow Direction Control................63
13.7 Horizontal Airflow Direction Control............64
13.8 Timer Control..............................................64
13.9 Random Auto Restart Control ....................65
13.10 Remote Control Signal Receiving
Sound ........................................................ 65
14. Protection Control........................................... 66
14.1 Restart Control (Time Delay Safety
Control)...................................................... 66
14.2 7 Minutes Time Save Control .................... 66
14.3 60 Seconds Forced Operation .................. 66
14.4 Starting Current Control ............................ 66
14.5 Freeze Prevention Control ........................ 66
14.6 Compressor Reverse Rotation Protection
Control ....................................................... 67
14.7 Dew Prevention Control ............................ 67
15. Servicing Mode................................................ 68
15.1 Auto OFF/ON Button ................................. 68
15.2 Remote Control Button.............................. 69
16. Troubleshooting Guide................................... 70
16.1 Refrigeration Cycle System....................... 70
17. Disassembly and Assembly Instructions ..... 72
17.1 CS-PC9/12QKH......................................... 72
17.2 CS-PC18/24/28QKH.................................. 76
18. Technical Data ................................................. 81
18.1 Thermostat Characteristics ....................... 81
18.2 Operation Characteristics.......................... 82
19. Exploded View and Replacement Parts
List .................................................................. 100
19.1 Indoor Unit ............................................... 100
19.2 Outdoor Unit ............................................ 107
3
CAUTION
WARNING
WARNING
1. Safety Precautions
Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the
power plug and main circuit for the model installed.
The caution items stated here must be followed because these important contents are related to safety. The
meaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instruction will cause harm or damage, and the seriousness is classified by the following indications.
This indication shows the possibility of causing death or serious injury.
This indication shows the possibility of causing injury or damage to properties.
The items to be followed are classified by the symbols:
Carry out test run to confirm that no abnormality occurs after the servicing. Then, explain to user the operation,
care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.
1. Do not modify the machine, part, material during repairing service.
2. If wiring unit is supplied as repairing part, do not repair or connect the wire even only partial wire break. Exchange the whole wiring unit.
3. Do not wrench the fasten terminal. Pull it out or insert it straightly.
4. Engage authorized dealer or specialist for installation and servicing. If installation of servicing done by the user is defective, it will cause water leakage, electrical shock or fire.
5. Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electric shock or fire.
6. Use the attached accessories parts and specified parts for installation and servicing. Otherwise, it will cause the set to fall, water leakage, fire or electrical shock.
7. Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly done, the set will drop and cause injury.
8. For electrical work, follow the local national wiring standard, regulation and the installation instruction. An independent circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire.
9. This equipment is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD). Otherwise, it may cause electrical shock and fire in case equipment breakdown or insulation breakdown.
10. Do not use joint cable for indoor/outdoor connection cable. Use the specified indoor/outdoor connection cable, refer to installation instruction CONNECT THE CABLE TO THE INDOOR UNIT and connect tightly for indoor/outdoor connection. Clamp the cable so that no external force will be acted on the terminal. If connecting or fixing is not perfect, it will cause heat up or fire at the connection.
11. Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause heat-up or fire at the connection point of terminal, fire or electrical shock.
12. When install or relocate air conditioner, do not let any substance other than the specified refrigerant, eg. air etc. mix into refrigeration cycle (piping). (Mixing of air etc. will cause abnormal high pressure in refrigeration cycle and result in explosion, injury etc.).
13. Do not install outdoor unit near handrail of veranda. When installing air-conditioner unit at veranda of high rise building, child may climb up to outdoor unit and cross over the handrail and causing accident.
14. This equipment must be properly earthed. Earth line must not be connected to gas pipe, water pipe, earth of lightning rod and telephone. Otherwise, it may cause electrical shock in case equipment breakdown or insulation breakdown.
15. Keep away from small children, the thin film may cling to nose and mouth and prevent breathing.
16. Do not use unspecified cord, modified cord, joint cord or extension cord for power supply cord. Do not share the single outlet with other electrical appliances. Poor contact, poor insulation or over current will cause electrical shock or fire.
17. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare may break and cause refrigerant gas leakage.
18. During pump down operation, stop the compressor before remove the refrigeration piping. (Removal of refrigeration piping while compressor is operating and valves are opened condition will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc.).
19. During installation, install the refrigerant piping properly before run the compressor. (Operation of compressor without fixing refrigeration piping and valves at opened condition will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc.).
This symbol denotes item that is PROHIBITED from doing.
4
CAUTION
20. After completion of installation or service, confirm there is no leakage of refrigerant gas. It may generate toxic gas when the refrigerant contacts with fire.
21. Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when the refrigerant contacts with fire.
22. Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury.
23. Must not use other parts except original parts describe in catalog and manual.
24. Using of refrigerant other than the specified type may cause product damage, burst and injury etc.
1. Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the unit, it may cause fire.
2. Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the furniture.
3. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare may break and cause refrigerant gas leakage.
4. Do not touch outdoor unit air inlet and aluminium fin. It may cause injury.
5. Select an installation location which is easy for maintenance.
6. Pb free solder has a higher melting point than standard solder; typically the melting point is 50°F – 70°F (30°C – 40°C) higher. Please use a high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C). Pb free solder will tend to splash when heated too high (about 1100°F / 600°C).
7. Power supply connection to the air conditioner. Connect the power supply cord of the air conditioner to the mains using one of the following methods. Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. In some countries, permanent connection of this room air conditioner to the power supply is prohibited. i. Power supply connection to the receptacle using a power plug. Use an approved 15/16A (1.0 ~ 1.5HP) or 16A (2.0HP) or 20A (2.5HP), 25A (3.0HP) power plug with earth pin for the connection to the socket. ii. Power supply connection to a circuit breaker for the permanent connection. Use an approved 16A (1.0 ~ 2.0HP) or 20A (2.5HP), 25A (3.0HP) circuit breaker for the permanent connection. It must be a double pole switch with a minimum 3.0 mm contact gap.
8. Do not release refrigerant during piping work for installation, servicing, reinstallation and during repairing a refrigerant parts. Take care of the liquid refrigerant, it may cause frostbite.
9. Installation or servicing work: It may need two people to carry out the installation or servicing work.
10. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
11. Do not sit or step on the unit, you may fall down accidentally.
12. Do not touch the sharp aluminum fins or edges of metal parts. If you are required to handle sharp parts during installation or servicing, please wear hand glove. Sharp parts may cause injury.
5
2. Specification
Indoor CS-PC9QKH (Others/S. E. ASIA) CS-PC12QKH (Others/S. E. ASIA)
Model
Outdoor CU-PC9QKH (Others/S. E. ASIA) CU-PC12QKH (Others/S. E. ASIA)
Performance Test Condition NEW JIS NEW JIS
Phase, Hz Single, 50 Single, 50
Power Supply
V 220 240 220 240
kW 2.65 2.70 3.49 3.54
Btu/h 9040 9210 11900 12100
Capacity
kJ/h 9540 9720 12560 12740
Running Current A 4.4 4.3 5.5 5.6
Input Power W 845 885 1.17k 1.21k
W/W 3.14 3.05 2.98 2.93
EER
Btu/hW 10.70 10.41 10.17 10.00
Power Factor % 87 86 97 90
dB-A 37 / 26 37 / 26 40 / 29 40 / 29
Indoor Noise (H / L)
Power Level dB 50 / - 50 / - 53 / - 53 / -
dB-A 47 / - 48 / - 49 / - 50 / -
Cooling
Outdoor Noise (H / L)
Power Level dB 62 / - 63 / - 64 / - 65 / -
Max Current (A) / Max Input Power (W) 4.9 / 1.10k 6.3 / 1.47k
Starting Current (A) 17.0 20.3
Type Rotary (1 cylinder) rolling piston type Rotary (1 cylinder) rolling piston type
Motor Type Induction (2 poles) Induction (2 poles)
Compressor
Output Power W 700 900
Type Cross-Flow Fan Cross-Flow Fan
Material ASG20K1 ASG20K1
Motor Type AC / Induction (4 poles) AC / Induction (4 poles)
Input Power W 42.5 45.0 51.0 58.0
Output Power W 22 24
Lo rpm 770 810
Me rpm 960 980
Hi rpm 1150 1150
Indoor Fan
Speed
SHi rpm 1180 1180
Type Propeller Fan Propeller Fan
Material PP Resin PP Resin
Motor Type AC / Induction (6 poles) AC / Induction (6 poles)
Input Power W 71.3 80.6 71.3 80.6
Output Power W 30 30
Outdoor Fan
Speed Hi rpm 800 830 830 860
Moisture Removal L/h (Pt/h) 1.6 (3.4) 2.1 (4.4)
Lo m3/min (ft3/min) 6.0 (210) 7.8 (276)
Me m3/min (ft3/min) 7.4 (262) 9.5 (334)
Hi m3/min (ft3/min) 8.9 (314) 11.1 (392)
Indoor Airflow
SHi m
3
/min (ft3/min) 9.1 (322) 11.4 (402)
Outdoor
Airflow
Hi m
3
/min (ft3/min) 28.8 (1020) 29.6 (1040) 22.0 (780) 23.6 (830)
Control Device Capillary Tube Capillary Tube
Refrigerant Oil cm3 ATMOS NM56M or Suniso 4GDID (350) ATMOS NM56M or Suniso 4GDID (350)
Refrigeration
Cycle
Refrigerant Type g (oz) R22, 440 (15.5) R22, 800 (28.2)
6
Indoor CS-PC9QKH (Others/S. E. ASIA) CS-PC12QKH (Others/S. E. ASIA)
Model
Outdoor CU-PC9QKH (Others/S. E. ASIA) CU-PC12QKH (Others/S. E. ASIA)
Height(I/D / O/D) mm (inch) 290 (11-7/16) / 511 (20-1/8) 290 (11-7/16) / 511 (20-1/8)
Width (I/D / O/D) mm (inch) 850 (33-15/32) / 650 (25-19/32) 850 (33-15/32) / 650 (25-19/32)
Dimension
Depth (I/D / O/D) mm (inch) 199 (7-27/32) / 230 (9-1/16) 199 (7-27/32) / 230 (9-1/16)
Weight Net (I/D / O/D) kg (lb) 8 (18) / 22 (49) 8 (18) / 24 (53)
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 9.52 (3/8) 6.35 (1/4) / 12.70 (1/2)
Standard length m (ft) 7.5 (24.6) 7.5 (24.6)
Length range (min – max) m (ft) 3 (9.8) ~ 10 (32.8) 3 (9.8) ~ 15 (49.2)
I/D & O/D Height different m (ft) 5 (16.4) 5 (16.4)
Additional Gas Amount g/m (oz/ft) 10 (0.1) 10 (0.1)
Piping
Length for Additional Gas m (ft) 7.5 (24.6) 7.5 (24.6)
Inner Diameter mm 16 16
Drain Hose
Length mm 550 550
Fin Material Aluminium (Pre coated) Aluminium (Pre coated)
Fin Type Slit Fin Slit Fin
Row x Stage x FPI 2 x 10 x 17 2 x 15 x 17
Indoor Heat
Exchanger
Size (W x H x L) mm 610 x 210 x 25.4 610 x 315 x 25.4
Fin Material Aluminium (Blue coated) Aluminium (Blue coated)
Fin Type Slit Fin Slit Fin
Row x Stage x FPI 1 x 23 x 17 2 x 23 x 17
Outdoor
Heat
Exchanger
Size (W x H x L) mm 12.7 x 483 x 578.4 25.4 x 483 x 573.4:553.4
Material Polypropelene Polypropelene
Air Filter
Type One-touch One-touch
Power Supply Indoor Indoor
Power Supply Cord A 10 10
Thermostat - -
Protection Device Overload Protector Overload Protector
DRY BULB WET BULB DRY BULB WET BULB
Maximum °C 32 23 32 23
Indoor Operation Range
Minimum °C 16 11 16 11
Maximum °C 43 26 43 26
Outdoor Operation Range
Minimum °C 16 11 16 11
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2.
Specifications are subjected to change without prior notice for further improvement.
7
Indoor CS-PC9QKH (MYANMAR) CS-PC12QKH (MYANMAR)
Model
Outdoor CU-PC9QKH (MYANMAR) CU-PC12QKH (MYANMAR)
Performance Test Condition NEW JIS NEW JIS
Phase, Hz Single, 50 Single, 50
Power Supply
V 220 240 220 240
kW 2.65 2.70 3.49 3.54
Btu/h 9040 9210 11900 12100
Capacity
kJ/h 9540 9720 12560 12740
Running Current A 4.4 4.3 6.0 6.0
Input Power W 845 885 1.17k 1.21k
W/W 3.14 3.05 2.98 2.93
EER
Btu/hW 10.70 10.41 10.17 10.00
Power Factor % 87 86 89 84
dB-A 37 / 26 37 / 26 40 / 29 40 / 29
Indoor Noise (H / L)
Power Level dB 50 / - 50 / - 53 / - 53 / -
dB-A 47 / - 48 / - 49 / - 50 / -
Cooling
Outdoor Noise (H / L)
Power Level dB 62 / - 63 / - 64 / - 65 / -
Max Current (A) / Max Input Power (W) 5.0 / 1.12k 7.0 / 1.55k
Starting Current (A) 19.0 26.0
Type Rotary (1 cylinder) rolling piston type Rotary (1 cylinder) rolling piston type
Motor Type Induction (2 poles) Induction (2 poles)
Compressor
Output Power W 750 950
Type Cross-Flow Fan Cross-Flow Fan
Material ASG20K1 ASG20K1
Motor Type AC / Induction (4 poles) AC / Induction (4 poles)
Input Power W 42.5 45.0 51.0 58.0
Output Power W 22 22
Lo rpm 770 810
Me rpm 960 980
Hi rpm 1150 1150
Indoor Fan
Speed
SHi rpm 1180 1180
Type Propeller Fan Propeller Fan
Material PP Resin PP Resin
Motor Type AC / Induction (6 poles) AC / Induction (6 poles)
Input Power W 59.6 68.8 59.6 68.8
Output Power W 25 25
Outdoor Fan
Speed Hi rpm 800 830 830 860
Moisture Removal L/h (Pt/h) 1.6 (3.4) 2.1 (4.2)
Lo m3/min (ft3/min) 6.0 (210) 7.8 (276)
Me m3/min (ft3/min) 7.4 (262) 9.5 (334)
Hi m3/min (ft3/min) 8.9 (314) 11.1 (392)
Indoor Airflow
SHi m
3
/min (ft3/min) 9.1 (322) 11.4 (402)
Outdoor
Airflow
Hi m
3
/min (ft3/min) 28.8 (1020) 29.6 (1040) 22.0 (780) 23.6 (830)
Control Device Capillary Tube Capillary Tube
Refrigerant Oil cm3 ATMOS NM56M or Suniso 4GDID (350) ATMOS NM56M or Suniso 4GDID (350)
Refrigeration
Cycle
Refrigerant Type g (oz) R22, 480 (16.9) R22, 840 (29.7)
8
Indoor CS-PC9QKH (MYANMAR) CS-PC12QKH (MYANMAR)
Model
Outdoor CU-PC9QKH (MYANMAR) CU-PC12QKH (MYANMAR)
Height(I/D / O/D) mm (inch) 290 (11-7/16) / 511 (20-1/8) 290 (11-7/16) / 511 (20-1/8)
Width (I/D / O/D) mm (inch) 850 (33-15/32) / 650 (25-19/32) 850 (33-15/32) / 650 (25-19/32)
Dimension
Depth (I/D / O/D) mm (inch) 199 (7-27/32) / 230 (9-1/16) 199 (7-27/32) / 230 (9-1/16)
Weight Net (I/D / O/D) kg (lb) 8 (18) / 21 (46) 8 (18) / 26 (57)
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 9.52 (3/8) 6.35 (1/4) / 12.70 (1/2)
Standard length m (ft) 7.5 (24.6) 7.5 (24.6)
Length range (min – max) m (ft) 3 (9.8) ~ 10 (32.8) 3 (9.8) ~ 15 (49.2)
I/D & O/D Height different m (ft) 5 (16.4) 5 (16.4)
Additional Gas Amount g/m (oz/ft) 10 (0.1) 10 (0.1)
Piping
Length for Additional Gas m (ft) 7.5 (24.6) 7.5 (24.6)
Inner Diameter mm 16 16
Drain Hose
Length mm 550 550
Fin Material Aluminium (Pre coated) Aluminium (Pre coated)
Fin Type Slit Fin Slit Fin
Row x Stage x FPI 2 x 10 x 17 2 x 15 x 17
Indoor Heat
Exchanger
Size (W x H x L) mm 610 x 210 x 25.4 610 x 315 x 25.4
Fin Material Aluminium (Blue coated) Aluminium (Blue coated)
Fin Type Slit Fin Slit Fin
Row x Stage x FPI 1 x 23 x 17 2 x 23 x 17
Outdoor
Heat
Exchanger
Size (W x H x L) mm 12.7 x 483 x 578.4 25.4 x 483 x 573.4:553.4
Material Polypropelene Polypropelene
Air Filter
Type One-touch One-touch
Power Supply Indoor Indoor
Power Supply Cord A 10 10
Thermostat - -
Protection Device Overload Protector Overload Protector
DRY BULB WET BULB DRY BULB WET BULB
Maximum °C 32 23 32 23
Indoor Operation Range
Minimum °C 16 11 16 11
Maximum °C 43 26 43 26
Outdoor Operation Range
Minimum °C 16 11 16 11
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2.
Specifications are subjected to change without prior notice for further improvement.
9
Indoor CS-PC18QKH (Others/S. E. ASIA) CS-PC24QKH (Others/S. E. ASIA)
Model
Outdoor CU-PC18QKH (Others/S. E. ASIA) CU-PC24QKH (Others/S. E. ASIA)
Performance Test Condition NEW JIS NEW JIS
Phase, Hz Single, 50 Single, 50
Power Supply
V 220 240 220 240
kW 5.28 5.30 6.93 7.03
Btu/h 18000 18100 23600 24000
Capacity
kJ/h 19010 19080 24950 25310
Running Current A 8.9 9.0 12.2 12.1
Input Power W 1.92k 1.98k 2.57k 2.70k
W/W 2.75 2.68 2.70 2.60
EER
Btu/hW 9.38 9.14 9.18 8.89
Power Factor % 98 92 96 93
dB-A 43 / 39 43 / 39 47 / 42 47 / 42
Indoor Noise (H / L)
Power Level dB 56 / - 56 / - 60 / - 60 / -
dB-A 54 / - 56 / - 56 / - 57 / -
Cooling
Outdoor Noise (H / L)
Power Level dB 69 / - 71 / - 71 / - 72 / -
Max Current (A) / Max Input Power (W) 9.9 / 2.31k 13.9 / 3.20k
Starting Current (A) 34.0 66.0
Type Rotary (1 cylinder) rolling piston type Rotary (1 cylinder) rolling piston type
Motor Type Induction (2 poles) Induction (2 poles)
Compressor
Output Power W 1.5k 2.0k
Type Cross-Flow Fan Cross-Flow Fan
Material ASG30K1 ASG30K1
Motor Type AC / Induction (4 poles) DC Motor (8 poles)
Input Power W 60.4 63.3 94.8 94.8
Output Power W 26 40
Lo rpm 1060 1150
Me rpm 1150 1240
Hi rpm 1240 1390
Indoor Fan
Speed
SHi rpm 1270 1420
Type Propeller Fan Propeller Fan
Material PP Resin PP Resin
Motor Type AC / Induction (6 poles) AC / Induction (6 poles)
Input Power W 70.6 78.8 162.8 178.2
Output Power W 36 74
Lo rpm - - - -
Outdoor Fan
Speed
Hi rpm 835 860 845 875
Moisture Removal L/h (Pt/h) 2.9 (6.1) 4.0 (8.5)
Lo m3/min (ft3/min) 14.0 (495) 15.5 (546)
Me m3/min (ft3/min) 15.2 (537) 16.7 (589)
Hi m3/min (ft3/min) 16.4 (579) 18.7 (660)
Indoor Airflow
SHi m
3
/min (ft3/min) 16.8 (593) 19.1 (674)
Outdoor
Airflow
Hi m
3
/min (ft3/min) 30.3 (1070) 31.3 (1100) 47.7 (1680) 49.4 (1740)
Control Device Capillary Tube Capillary Tube
Refrigerant Oil cm3 ATMOS NM56M or Suniso 4GDID (450) ATMOS M60 or Suniso 4GDID (700)
Refrigeration
Cycle
Refrigerant Type g (oz) R22, 910 (32.1) R22, 1.09k (38.5)
10
Indoor CS-PC18QKH (Others/S. E. ASIA) CS-PC24QKH (Others/S. E. ASIA)
Model
Outdoor CU-PC18QKH (Others/S. E. ASIA) CU-PC24QKH (Others/S. E. ASIA)
Height(I/D / O/D) mm (inch) 290 (11-7/16) / 542 (21-11/32) 290 (11-7/16) / 695 (27-3/8)
Width (I/D / O/D) mm (inch) 1070 (42-5/32) / 780 (30-23/32) 1070 (42-5/32) / 875 (34-15/32)
Dimension
Depth (I/D / O/D) mm (inch) 240 (9-15/32) / 289 (11-13/32) 240 (9-15/32) / 320 (12-5/8)
Weight Net (I/D / O/D) kg (lb) 12 (26) / 34 (75) 12 (26) / 52 (115)
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 12.70 (1/2) 6.35 (1/4) / 15.88 (5/8)
Standard length m (ft) 5.0 (16.4) 5.0 (16.4)
Length range (min – max) m (ft) 3 (9.8) ~ 25 (82.0) 3 (9.8) ~ 25 (82.0)
I/D & O/D Height different m (ft) 20 (65.6) 20 (65.6)
Additional Gas Amount g/m (oz/ft) 20 (0.2) 30 (0.3)
Piping
Length for Additional Gas m (ft) 7.5 (24.6) 7.5 (24.6)
Inner Diameter mm 14 14
Drain Hose
Length mm 550 550
Fin Material Aluminium (Pre coated) Aluminium (Pre coated)
Fin Type Slit Fin Slit Fin
Row x Stage x FPI 2 x 15 x 17 2 x 15 x 17
Indoor Heat
Exchanger
Size (W x H x L) mm 810 x 315 x 25.4 810 x 315 x 25.4
Fin Material Aluminium (Blue coated) Aluminium (Blue coated)
Fin Type Slit Fin Slit Fin
Row x Stage x FPI 2 x 24 x 17 2 x 31 x 17
Outdoor
Heat
Exchanger
Size (W x H x L) mm 25.4 x 504 x 693.4:713.4 25.4 x 651 x 640
Material Polypropelene Polypropelene
Air Filter
Type One-touch One-touch
Power Supply Indoor Indoor
Power Supply Cord A 16 20
Thermostat - Mechanical
Protection Device Overload Protector -
DRY BULB WET BULB DRY BULB WET BULB
Maximum °C 32 23 32 23
Indoor Operation Range
Minimum °C 16 11 16 11
Maximum °C 43 26 43 26
Outdoor Operation Range
Minimum °C 16 11 16 11
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2.
Specifications are subjected to change without prior notice for further improvement.
11
Indoor CS-PC18QKH (MYANMAR) CS-PC24QKH (MYANMAR)
Model
Outdoor CU-PC18QKH (MYANMAR) CU-PC24QKH (MYANMAR)
Performance Test Condition NEW JIS NEW JIS
Phase, Hz Single, 50 Single, 50
Power Supply
V 220 240 220 240
kW 5.28 5.30 6.93 7.03
Btu/h 18000 18100 23600 24000
Capacity
kJ/h 19010 19080 24950 25310
Running Current A 8.9 9.0 12.2 12.1
Input Power W 1.92k 1.98k 2.57k 2.70k
W/W 2.75 2.68 2.70 2.60
EER
Btu/hW 9.38 9.14 9.18 8.89
Power Factor % 98 92 96 93
dB-A 43 / 39 43 / 39 47 / 42 47 / 42
Indoor Noise (H / L)
Power Level dB 56 / - 56 / - 60 / - 60 / -
dB-A 54 / - 56 / - 56 / - 57 / -
Cooling
Outdoor Noise (H / L)
Power Level dB 69 / - 71 / - 71 / - 72 / -
Max Current (A) / Max Input Power (W) 10.9 / 2.44k 15.0 / 3.28k
Starting Current (A) 40.0 59.0
Type Rotary (1 cylinder) rolling piston type Rotary (1 cylinder) rolling piston type
Motor Type Induction (2 poles) Induction (2 poles)
Compressor
Output Power W 1.5k 2.0k
Type Cross-Flow Fan Cross-Flow Fan
Material ASG30K1 ASG30K1
Motor Type AC / Induction (4 poles) DC Motor (8 poles)
Input Power W 60.4 63.3 94.8 94.8
Output Power W 26 40
Lo rpm 1060 1150
Me rpm 1150 1240
Hi rpm 1240 1390
Indoor Fan
Speed
SHi rpm 1270 1420
Type Propeller Fan Propeller Fan
Material PP Resin PP Resin
Motor Type AC / Induction (6 poles) AC / Induction (6 poles)
Input Power W 70.6 78.8 162.8 178.2
Output Power W 36 81
Lo rpm - - - -
Outdoor Fan
Speed
Hi rpm 835 860 845 875
Moisture Removal L/h (Pt/h) 2.9 (6.1) 4.0 (8.5)
Lo m3/min (ft3/min) 14.0 (495) 15.5 (546)
Me m3/min (ft3/min) 15.2 (537) 16.7 (589)
Hi m3/min (ft3/min) 16.4 (579) 18.7 (660)
Indoor Airflow
SHi m
3
/min (ft3/min) 16.8 (593) 19.1 (674)
Outdoor
Airflow
Hi m
3
/min (ft3/min) 30.3 (1070) 31.3 (1100) 47.7 (1680) 49.4 (1740)
Control Device Capillary Tube Capillary Tube
Refrigerant Oil cm3 ATMOS NM56M or Suniso 4GDID (450) ATMOS M60 or Suniso 4GDID (700)
Refrigeration
Cycle
Refrigerant Type g (oz) R22, 920 (32.5) R22, 1.16k (40.9)
12
Indoor CS-PC18QKH (MYANMAR) CS-PC24QKH (MYANMAR)
Model
Outdoor CU-PC18QKH (MYANMAR) CU-PC24QKH (MYANMAR)
Height(I/D / O/D) mm (inch) 290 (11-7/16) / 542 (21-11/32) 290 (11-7/16) / 695 (27-3/8)
Width (I/D / O/D) mm (inch) 1070 (42-5/32) / 780 (30-23/32) 1070 (42-5/32) / 875 (34-15/32)
Dimension
Depth (I/D / O/D) mm (inch) 240 (9-15/32) / 289 (11-13/32) 240 (9-15/32) / 320 (12-5/8)
Weight Net (I/D / O/D) kg (lb) 12 (26) / 37 (82) 12 (26) / 52 (115)
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 12.70 (1/2) 6.35 (1/4) / 15.88 (5/8)
Standard length m (ft) 5.0 (16.4) 5.0 (16.4)
Length range (min – max) m (ft) 3 (9.8) ~ 25 (82.0) 3 (9.8) ~ 25 (82.0)
I/D & O/D Height different m (ft) 20 (65.6) 20 (65.6)
Additional Gas Amount g/m (oz/ft) 20 (0.2) 30 (0.3)
Piping
Length for Additional Gas m (ft) 7.5 (24.6) 7.5 (24.6)
Inner Diameter mm 14 14
Drain Hose
Length mm 550 550
Fin Material Aluminium (Pre coated) Aluminium (Pre coated)
Fin Type Slit Fin Slit Fin
Row x Stage x FPI 2 x 15 x 17 2 x 15 x 17
Indoor Heat
Exchanger
Size (W x H x L) mm 810 x 315 x 25.4 810 x 315 x 25.4
Fin Material Aluminium (Blue coated) Aluminium (Blue coated)
Fin Type Slit Fin Slit Fin
Row x Stage x FPI 2 x 24 x 17 2 x 31 x 17
Outdoor
Heat
Exchanger
Size (W x H x L) mm 25.4 x 504 x 693.4:713.4 25.4 x 651 x 640
Material Polypropelene Polypropelene
Air Filter
Type One-touch One-touch
Power Supply Indoor Indoor
Power Supply Cord A 16 20
Thermostat - Mechanical
Protection Device Overload Protector -
DRY BULB WET BULB DRY BULB WET BULB
Maximum °C 32 23 32 23
Indoor Operation Range
Minimum °C 16 11 16 11
Maximum °C 43 26 43 26
Outdoor Operation Range
Minimum °C 16 11 16 11
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2.
Specifications are subjected to change without prior notice for further improvement.
13
Indoor CS-PC28QKH (Others/S. E. ASIA)
Model
Outdoor CU-PC28QKH (Others/S. E. ASIA)
Performance Test Condition NEW JIS
Phase, Hz Single, 50
Power Supply
V 220 240
kW 7.90 8.00
Btu/h 26900 27300
Capacity
kJ/h 28440 28800
Running Current A 14.0 13.1
Input Power W 2.99k 3.04k
W/W 2.64 2.63
EER
Btu/hW 9.00 8.98
Power Factor % 97 97
dB-A 50 / 46 50 / 46
Indoor Noise (H / L)
Power Level dB 63 / - 63 / -
dB-A 55 / - 57 / -
Cooling
Outdoor Noise (H / L)
Power Level dB 70 / - 72 / -
Max Current (A) / Max Input Power (W) 15.7 / 3.47k
Starting Current (A) 65.2
Type Rotary (1 cylinder) rolling piston type
Motor Type Induction (2 poles)
Compressor
Output Power W 2.4k
Type Cross-Flow Fan
Material ASG30K1
Motor Type DC Motor (8 poles)
Input Power W 94.8 94.8
Output Power W 40
Lo rpm 1250 1250
Me rpm 1400 1400
Hi rpm 1490 1490
Indoor Fan
Speed
SHi rpm 1520 1520
Type Propeller Fan
Material PP Resin
Motor Type AC / Induction (6 poles)
Input Power W 163.0 183.0
Output Power W 81
Lo rpm 440 500
Outdoor Fan
Speed
Hi rpm 860 890
Moisture Removal L/h (Pt/h) 4.7 (9.9)
Lo m3/min (ft3/min) 16.9 (598)
Me m3/min (ft3/min) 19.0 (670)
Hi m3/min (ft3/min) 20.2 (713)
Indoor Airflow
SHi m
3
/min (ft3/min) 20.6 (727)
Lo m3/min (ft3/min) 24.8 (880) 28.4 (1000)
Outdoor
Airflow
Hi m
3
/min (ft3/min) 48.5 (1710) 50.5 (1780)
Control Device Capillary Tube
Refrigerant Oil cm3 ATMOS M60 or Suniso 4GDID (900)
Refrigeration
Cycle
Refrigerant Type g (oz) R22, 1.60k (56.5)
14
Indoor CS-PC28QKH (Others/S. E. ASIA)
Model
Outdoor CU-PC28QKH (Others/S. E. ASIA)
Height(I/D / O/D) mm (inch) 290 (11-7/16) / 750 (29-17/32)
Width (I/D / O/D) mm (inch) 1070 (42-5/32) / 875 (34-15/32)
Dimension
Depth (I/D / O/D) mm (inch) 240 (9-15/32) / 345 (13-19/32)
Weight Net (I/D / O/D) kg (lb) 12 (26) / 62 (137)
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 15.88 (5/8)
Standard length m (ft) 5.0 (16.4)
Length range (min – max) m (ft) 3 (9.8) ~ 30 (98.4)
I/D & O/D Height different m (ft) 20 (65.6)
Additional Gas Amount g/m (oz/ft) 30 (0.3)
Piping
Length for Additional Gas m (ft) 7.5 (24.6)
Inner Diameter mm 12
Drain Hose
Length mm 550
Fin Material Aluminium (Pre coated)
Fin Type Slit Fin
Row x Stage x FPI 2 x 15 x 21
Indoor Heat
Exchanger
Size (W x H x L) mm 810 x 315 x 25.4
Fin Material Aluminium (Blue coated)
Fin Type Corrugate Fin
Row x Stage x FPI 2 x 28 x 19
Outdoor
Heat
Exchanger
Size (W x H x L) mm 44 x 711.2 x 836.9
Material Polypropelene
Air Filter
Type One-touch
Power Supply Outdoor
Power Supply Cord A 20
Thermostat Mechanical
Protection Device -
DRY BULB WET BULB
Maximum °C 32 23
Indoor Operation Range
Minimum °C 16 11
Maximum °C 43 26
Outdoor Operation Range
Minimum °C 16 11
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2.
Specifications are subjected to change without prior notice for further improvement.
15
3. Features
Long Installation Piping
o CS/CU-PC9QK long piping up to 10 meters. o CS/CU-PC12QK long piping up to 15 meters. o CS/CU-PC18QK, PC24QK long piping up to 25 meters. o CS/CU-PC28QK long piping up to 30 meters.
Easy to use remote control
Quality Improvement
o Random auto restart after power failure for safety restart operation o Gas leakage protection o Prevent compressor reverse cycle o Overload protector to protect compressor o Noise prevention during soft dry operation o Blue coated condenser for high resistance to corrosion
Operation Improvement
o 24-hour timer setting
16
4. Location of Controls and Components
4.1 Indoor Unit
4.2 Outdoor Unit
4.3 Remote Control
17
5. Dimensions
5.1 Indoor Unit
5.1.1 CS-PC9QKH CS-PC12QKH
18
5.1.2 CS-PC18QKH CS-PC24QKH CS-PC28QKH
19
5.2 Outdoor Unit
5.2.1 CU-PC9QKH CU-PC12QKH
5.2.2 CU-PC18QKH
20
5.2.3 CU-PC24QKH
5.2.4 CU-PC28QKH
21
6. Refrigeration Cycle Diagram
22
7. Block Diagram
7.1 CS-PC9QKH CU-PC9QKH CS-PC12QKH CU-PC12QKH
CS-PC18QKH CU-PC18QKH
23
7.2 CS-PC24QKH CU-PC24QKH
24
7.3 CS-PC28QKH CU-PC28QKH
25
8. Wiring Connection Diagram
8.1 CS-PC9QKH CU-PC9QKH CS-PC12QKH CU-PC12QKH
Resistance of Indoor Fan Motor Windings
Resistance of Indoor Fan Motor Windings
CS-PC9QKH CS-PC12QKH
MODEL
Others/S. E. Asia Myanmar
MODEL
Others/S. E. Asia Myanmar
CONNECTION CWA921562 CWA921559 CONNECTION CWA921561 CWA921559
BLUE-YELLOW 357 Ω 366 BLUE-YELLOW 336 Ω 366
YELLOW-RED 363 Ω 338 YELLOW-RED 306 Ω 338
Note: Resistance at 20°C of ambient temperature. Note: Resistance at 20°C of ambient temperature.
Resistance of Outdoor Fan Motor Windings
Resistance of Outdoor Fan Motor Windings
CU-PC9QKH CU-PC12QKH
MODEL
Others/S. E. Asia Myanmar
MODEL
Others/S. E. Asia Myanmar
CONNECTION CWA951852 CWA951673 CONNECTION CWA951852 CWA951673
BLUE-YELLOW 331 Ω 318 BLUE-YELLOW 331 Ω 318
YELLOW-RED 320 Ω 272 YELLOW-RED 320 Ω 272
Note: Resistance at 20°C of ambient temperature. Note: Resistance at 20°C of ambient temperature.
Resistance of Compressor Windings
Resistance of Compressor Windings
CU-PC9QKH CU-PC12QKH
MODEL
Others/S. E. Asia Myanmar
MODEL
Others/S. E. Asia Myanmar
CONNECTION 2PS146D3BA06 2PS156D3AA06 CONNECTION 2PS192D3BA06 2PS206D3BA06
C-R 5.091 Ω 4.032 Ω C-R 4.673 Ω 3.196
C-S 5.382 Ω 5.006 Ω C-S 4.895 Ω 5.277
Note: Resistance at 20°C of ambient temperature. Note: Resistance at 20°C of ambient temperature.
26
8.2 CS-PC18QKH CU-PC18QKH
Resistance of Indoor Fan Motor Windings
Resistance of Compressor Windings
CS-PC18QKH CU-PC18QKH
MODEL
Others/S. E. Asia Myanmar
MODEL
Others/S. E. Asia Myanmar
CONNECTION CWA921459 CONNECTION 2KS314D5CA06 2KS314D5BA06
BLUE-YELLOW 230 C-R 2.298 Ω 1.853
YELLOW-RED 298 C-S 3.223 Ω 4.879
Note: Resistance at 20°C of ambient temperature. Note: Resistance at 20°C of ambient temperature.
Resistance of Outdoor Fan Motor Windings
CU-PC18QKH
MODEL
Others/S. E. Asia Myanmar
CONNECTION CWA951688 CWA951851
BLUE-YELLOW 276 Ω 247
YELLOW-RED 291 Ω 254
Note: Resistance at 20°C of ambient temperature.
27
8.3 CS-PC24QKH CU-PC24QKH
Resistance of Outdoor Fan Motor Windings
Resistance of Compressor Windings
MODEL CU-PC24QKH CU-PC24QKH
CONNECTION CWA951697
MODEL
Others/S. E. Asia Myanmar
BLUE-YELLOW 70 CONNECTION 2JS438D3GA04 2JS438D3EA04
YELLOW-RED 51 C-R 1.338 Ω 1.156
YELLOW-ORANGE 69 C-S 2.420 Ω 2.997
Note: Resistance at 20°C of ambient temperature. Note: Resistance at 20°C of ambient temperature.
28
8.4 CS-PC28QKH CU-PC28QKH
Resistance of Outdoor Fan Motor Windings
Resistance of Compressor Windings
MODEL CU-PC28QKH MODEL CU-PC28QKH
CONNECTION CWA951697 CONNECTION 2JD514E3AA03
BLUE-YELLOW 70 C-R 1.022
YELLOW-RED 51 C-S 2.142
YELLOW-ORANGE 69 Note: Resistance at 20°C of ambient temperature.
Note: Resistance at 20°C of ambient temperature. .
29
9. Electronic Circuit Diagram
9.1 CS-PC9QKH CU-PC9QKH CS-PC12QKH CU-PC12QKH
30
9.2 CS-PC18QKH CU-PC18QKH
Loading...
+ 85 hidden pages