Panasonic CS-PC18DKQ, CS-PC24DKQ, CU-PC24DKQ, CU-PC18DKQ Operating Instructions Manual

Manufactured by:
Panasonic HA Air-Conditioning (M) Sdn. Bhd.
Lot 2, Persiaran Tengku Ampuan, Section 21, Shah Alam Industrial Site, 40300 Shah Alam, Selangor, Malaysia.
© 2007 Panasonic HA Air-Conditioning (M) Sdn. Bhd. (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law.
TIMER
F565790
Operating Instructions
Air Conditioner
Indoor Unit Outdoor Unit
CS-PC18DKQ CU-PC18DKQ CS-PC24DKQ CU-PC24DKQ
ENGLISH
ENGLISH
2 ~ 7
2 ~ 7
Before operating the unit, read these
Before operating the unit, read these
operating instructions thoroughly and
operating instructions thoroughly and
keep them for future reference.
keep them for future reference.
ESPAÑOL
ESPAÑOL
8 ~ 13
8 ~ 13
Antes de utilizar la unidad, sírvase leer
Antes de utilizar la unidad, sírvase leer
atentamente estas instrucciones de
atentamente estas instrucciones de
funcionamiento y conservarlas como
funcionamiento y conservarlas como
futuro elemento de consulta.
futuro elemento de consulta.
QUICK GUIDE
QUICK GUIDE
GUÍA RÁPIDA
GUÍA RÁPIDA
2
DEFINITION
To prevent personal injury, injury to others, or property damage, please observe the following. Incorrect operation due to failure to follow instructions may cause harm or damage, the seriousness of which is classifi ed as below:
Warning
This sign warns of death or serious injury.
Caution
This sign warns of injury or damage to property.
The instructions to be followed are classifi ed by the following symbols:
SAFETY PRECAUTIONS SAFETY PRECAUTIONS
This symbol denotes an action that is PROHIBITED.
These symbols denote actions that are COMPULSORY.
Caution
Warning
Indoor Unit
• Do not install the unit in a potentially explosive atmosphere.
• Do not wash the unit with water, benzene, thinner or scouring powder.
• Do not use for other purposes such as preservation of food.
• Do not use any combustible equipment in front of the airfl ow outlet.
• Do not expose directly to cold air for a long period.
• Ensure that the drainage pipe is connected properly. Otherwise, leakage may occur.
• Aerate the room regularly.
Remote Control
• Do not use rechargeable (Ni-Cd) batteries.
• Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries.
• Remove the batteries if the unit is not going to be used for a long period of time.
• New batteries of the same type must be inserted following the polarity stated to prevent malfunction of the remote control.
Power Supply
• Do not share the same power outlet with other equipment.
• Do not modify power cords.
• Do not use extension cords.
• Do not operate with wet hands.
• Do not operate or stop the unit by inserting or pulling out the power plug.
• Insert the power plug properly.
• Use the specifi ed supply cord.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a hazard.
• Dust on the electric power plug should be periodically wiped with a dry cloth.
• This equipment must be earthed and installed with ELCB. Otherwise, it may cause electrical shock or fi re in case of malfunction.
• In case of emergency or abnormal conditions (burnt smell, etc), turn off the power supply and unplug, and consult your nearest dealer.
Outdoor Unit
• Do not sit or place anything on the indoor or outdoor unit.
• Do not touch the sharp aluminium n.
• After long periods of use, make sure the installation rack is not damaged.
Indoor Unit
• Do not install, remove and reinstall the unit by yourself; improper installation will cause leakage, electric shock or fi re. Please consult an authorized dealer or specialist for the installation work.
• Do not insert your fi ngers or other objects into the indoor or outdoor unit.
• Do not attempt to repair the unit by yourself.
Power Supply
• Do not pull the cord to disconnect the plug.
• Switch off the power supply and unplug before cleaning or servicing.
• Turn off the power supply and unplug if the unit is not used for a long period of time.
• This air conditioner is equipped with a built-in surge protective device. However, in order to further protect your air conditioner from being damaged by abnormally strong lightning activity, you may want to disconnect it from the power supply. Do not touch the air conditioner during lightning, it may cause electric shock.
Air inlet
Air inlet
Air
Air
outlet
outlet
Air outlet
Air inlet
Air inlet
3
ENGLISH
REGULATORY INFORMATION REGULATORY INFORMATION
Thank you for purchasing
Air Conditioner
The appliance is not intended for use by young children or the infi rm person without supervision. Young children should be supervised to ensure that they do not play with the appliance.
OPERATION CONDITION
OPERATION CONDITION
Use this air conditioner under the following temperature range
Temperature (°C)
Indoor Outdoor
*DBT *WBT *DBT *WBT
COOLING
Maximum 32 23 43 26
Minimum 16 11 16 11
* DBT: Dry bulb temperature * WBT: Wet bulb temperature
TABLE OF CONTENTS
TABLE OF CONTENTS
NOTE :
NOTE :
The illustrations in this manual are for explanation purposes only and may differ from the actual unit. It is subjected to change without notice for future improvement.
ENVIRONMENTAL REQUIREMENTS
Battery Disposal The batteries must be recycled or disposed of properly.
END-OF-LIFE DISPOSAL
“Instructions for end-user” for air conditioners:
Information on Disposal in other countries outside the European Union
This symbol is only valid in the European Union. If you wish to discard this product, please contact your installer, dealer or local authority and ask for the correct method of disposal.
SAFETY PRECAUTIONS
2
REGULATORY INFORMATION
3
PRODUCT OVERVIEW & OPERATIONS
4~5
CARE & CLEANING
6
TROUBLESHOOTING
7
QUICK GUIDE
BACK COVER
Replacement or installation of power plugs shall be performed by authorized/qualifi ed personnel only. The wires in this mains lead are coloured in accordance with the following code:
Terminals
Red
wires
live
neutral
earth
colours (GB Standard)
blue
green-yellow
brown
Black
Green/Yellow
Wiring colour may vary depending on a country wiring code’s standard.
4
PRODUCT OVERVIEW & OPERATIONS PRODUCT OVERVIEW & OPERATIONS
Front panel
Receiver
Auto OFF/ON button
• Used when remote control is misplaced or malfunction.
Action Mode
Press once. Auto Press and hold until 1 beep
is heard, then release.
Cooling
Press the button to turn off.
Maximum distances: 8m
AUTO
FAN
SPEED
AIR
SWING
COOL
OFF
TIMER
ON
TIMER
DRY
OFF/ON
TEMP
AIR SWING
FAN SPEED
MOD
E
CLOCK
RESET
TIMER
ON
123
OFF
SET
CANCEL
Remote control display
Vertical airfl ow direction louver
• Do not adjust by hand.
Horizontal airfl ow direction louver
• Manually adjustable.
Air Filters
INDICATOR
5
ENGLISH
TO SET THE TIMER
TO SET THE TIMER
• To turn ON or OFF the unit at a preset time.
Select ON or
OFF timer.
Set the time. Confi rm.
• To cancel ON or OFF timer, press
or then
press .
• When ON Timer is set, the unit may start earlier (up to 15 minutes) before the actual set time in order to achieve the desired temperature on time.
• Timer operation is based on the clock set in the remote control and repeats daily once set. For clock setting, please refer to Remote Control Preparation at back cover.
• If timer is cancelled manually or due to power failure, you can restore the previous setting (once power is resumed) by pressing
.
OPTIONAL SETTINGS
OPTIONAL SETTINGS
CLOCK
Press and hold for approximately 10 seconds to show 12-hour (am/pm) or 24­hour time indication.
RESET
Press to restore the remote control’s default setting.
Set the temperature 1°C higher in cool mode than the desired temperature to achieve a 10% power saving.
Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode.
TO TURN ON OR OFF THE UNIT
TO SET TEMPERATURE
• For cool and dry modes, the range of temperature for selection is 16°C ~ 30°C.
• Operating the unit within the recommended temperature could induce energy saving. COOL mode : 26˚C ~ 28˚C. DRY mode : 1˚C ~ 2˚C lower than room temperature.
TO SELECT OPERATION MODE
AUTO mode - For your convenience
• Unit selects the operation mode according to the room temperature.
• Once auto mode is selected, the unit will operate at the standard setting temperature.
Room
temperature
Operation
mode
Standard setting
temperature
23°C & above Cool 25°C
Below 23°C Dry 22°C
• To change the standard setting temperature, press
for “HI” or for “LO”.
Operation mode HI (+2°C) LO (-2°C)
Cool 27°C 23°C
Dry 24°C 20°C
COOL mode - To enjoy cool air DRY mode - To dehumidify the environment
• Unit operates at low fan speed to give a gentle cooling operation.
TO SELECT FAN SPEED (3 OPTIONS)
• For AUTO, the indoor fan speed is automatically
adjusted according to the operation mode.
TO ADJUST VERTICAL AIRFLOW DIRECTION (5 OPTIONS)
• Keeps the room ventilated.
• If AUTO is set, the louvers swing up/down
automatically.
Loading...