TABLE OF CONTENTS
TABLE OF CONTENTS
MULTI AIR CONDITIONER SYSTEM
2
OPERATION CONDITION
3
SAFETY PRECAUTIONS
4~5
REMOTE CONTROL
6~8
INDOOR UNIT
9
TROUBLESHOOTING
10
INFORMATION
11
QUICK GUIDE
BACK COVER
NOTE : The illustrations in this manual are for explanation purposes only and may differ from the actual unit. They are
subjected to change without notice for future improvement.
MULTI AIR CONDITIONER SYSTEM
MULTI AIR CONDITIONER SYSTEM
Multi Split Outdoor Unit (U-2E15GBE, U-2E18CBPG, U-3E18JBE, U-4E23JBE)
DEFINITION
Multi air conditioner systems save space by letting you connect multiple indoor units to a single outdoor unit.
Room A
Room A
Room B
Room B
Room C
Room C
Multi Split Outdoor Unit
Multi Split Outdoor Unit
INDOOR UNIT
INDOOR UNIT
• It is possible to operate the indoor units individually or simultaneously. The operation mode priority is given to the rst unit that turned on.
• During operation, heating and cooling mode can not be activated at the same time for different indoor unit. The power indicator blinks to indicate the indoor unit is standing by for different operation mode.
* Note: For complete product combination, please refer to catalog.
Caution
NANOE-G
operations could be activated even when the air-conditioner is turned off. In this condition, once nanoe-G indicator is ON, the unit will operate with AUTO fan speed and air swing. However, this operation could not be activated or will be deactivated if other indoor unit is activating heating mode.
ENGLISH
3
OPERATION CONDITION
OPERATION CONDITION
Use this air conditioner under the following temperature range
Single Split Outdoor Unit (CU-E7NKD, CU-E9NKD, CU-E12NKD, CU-E15NKD, CU-E18NKD)
Temperature (°C)
Indoor Outdoor
*DBT *WBT *DBT *WBT
COOLING
Max. 32 23 43 26
Min. 16 11 16 11
HEATING
Max. 30 - 24 18
Min. 16 - -5 -6
Multi Split Outdoor Unit
Temperature (°C)
Indoor
Outdoor Outdoor
U-2E15GBE, U-2E18CBPG U-3E18JBE, U-4E23JBE
*DBT *WBT *DBT *WBT *DBT *WBT
COOLING
Max. 32 23 43 26 46 26
Min. 16 11 16 11 -10 -
HEATING
Max. 30 - 24 18 24 18
Min. 16 - -10 -11 -15 -16
* DBT: Dry bulb temperature * WBT: Wet bulb temperature
4
SAFETY PRECAUTIONS
To prevent personal injury, injury to others, or property damage, please comply with the following. Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classifi ed as below:
WARNING
WARNING
This sign warns of death or serious injury.
CAUTION
CAUTION
This sign warns of injury or damage to property.
The instructions to be followed are classifi ed by the following symbols:
This symbol denotes an action that is PROHIBITED.
These symbols denote an actions that is
COMPULSORY.
WARNING
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to clean the internal parts, repair, install, remove and reinstall the unit. Improper installation and handling will cause leakage, electric shock or re.
Confi rm to authorized dealer or specialist on usage of specifi ed refrigerant type. Using of refrigerant other than the specifi ed type may cause product damage, burst and injury etc.
Do not install the unit in a potentially explosive or fl ammable atmosphere. Failure to do so could result in fi re.
Do not insert your fi ngers or other objects into the air conditioner indoor or outdoor unit, rotating parts may cause injury.
Do not touch the outdoor unit during lightning, it may cause electric shock.
Do not expose yourself directly to cold air for a long period to avoid excess cooling.
Do not sit or step on the unit, you may fall down accidentally.
REMOTE CONTROL
Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries.
POWER SUPPLY
Do not use a modifi ed cord, joint cord, extension cord or unspecifi ed cord to prevent overheating and fi re.
To prevent overheating, fi re or electric shock:
• Do not share the same power outlet with other equipment.
• Do not operate with wet hands.
• Do not over bend the power supply cord.
• Do not operate or stop the unit by inserting or pulling out the power plug.
Air Inlet
Air Inlet
Air Outlet
Air Outlet
Air Outlet
Air Outlet
Air Inlet
Air Inlet
Remote
Control
Power
Supply