ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference.2 ~ 7
ESPAÑOL Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como futuro elemento
de consulta.
Please register your product at : www.panasonic.com/register
For assistance, please call : (866)-292-7292, for Hawaii residents call (808)-488-7779.
Manufactured by:
Panasonic HA Air-Conditioning (M) Sdn. Bhd.
Lot 2, Persiaran Tengku Ampuan, Section 21, Shah Alam Industrial Site, 40300 Shah Alam, Selangor, Malaysia.
8 ~ 13
Thank you for purchasing a Panasonic Air Conditioner
■ Important notice
To prevent personal injury, injury
to others and property damage,
the following instructions must
be followed.
Incorrect operation due to
failure to follow instructions
will cause harm or damage,
the seriousness of which is
classified as
below:
Warning
This sign warns of death or
serious injury.
Caution
This sign warns of injury or
damage to property.
The instructions to be followed
are classified by the following
symbols:
This symbol denotes an
action that is PROHIBITED.
SAFETY PRECAUTIONS
Installation Precautions
Warning
Do not install, remove or reinstall the unit by yourself.
• Improper installation will cause leakage, electric shock or fire. Please consult an authorized dealer or
specialist for the installation work.
Caution
• This air conditioner must be grounded. Improper grounding will cause electric shock.
• Ensure that the drainage piping is connected properly.
• Current leakage protection equipment must be installed. Otherwise, electric shock or fire may
occur.
• Do not install the unit in a
potentially explosive environment.
Operation Precautions
• Do not share power outlet.
• Do not modi
• Do not use an extension co
• Do not operate with wet hands.
• Do not insert fingers or other objects into
the indoor or outdoor unit.
• Do not attempt to repair the unit by
yourself.
• Do not use rechargeable (Ni-Cd) batteries.
• Keep the remote control away from infants
and small children to prevent them from
accidentally swallowing the batteries.
fy power cord.
rd.
Otherwise, water will leak.
Warning
• Use specified supply cord.
• If the supply cord is damaged or needs
replacement, it must be replaced by
the manufacturer or its service agent or
a similarly qualified person in order to
avoid a hazard.
• Remove the batteries if the unit is not
going to be used for a long period of
time.
• New batteries of the same type must
be inserted following the polarity stated
to prevent malfunction of the remote
control.
• In case of emergency or if an abnormal
condition (burnt smell, etc) occurs, turn
off the power supply.
These symbols denote
actions that are
COMPULSORY.
• Do not wash the unit with water, benzene,
thinner or scouring powder.
• Do not use for other purposes such as
preservation of food.
• Do not store or use any combustible
equipment in the airflow direction.
• Do not sit on or place anything on the
indoor or outdoor unit.
• Do not expose directly to cold air for a long
period.
Safety Regulation
The appliance is not intended for use by young children or infirm
people without supervision. Young children should be supervised to
ensure that they do not play with the appliance.
Power Supply
Time Delay Fuse Rated Volts
15 Amps
CS-C18DKU/CU-C18DKU
25 Amps
CS-C24DKU/CU-C24DKU
208/230V
2
Caution
• Ventilate the room regularly.
• Pay attention as to whether the
installation rack is damaged after a long
period of usage.
• Switch off the power supply before
cleaning or servicing.
• Turn off the power supply if the unit is
not going to be used for a long period of
time.
Operation Condition (°F)
Use this air conditioner under the following temperature range.
DBT: Dry Bulb Temperature
WBT: Wet Bulb Temperature
Maximum Temperature89.673.4109.478.8
Minimum Temperature
IndoorOutdoor
DBTWBTDBTWBT
60.851.860.851.8
TEMP
MODE
POWERFUL
AIR SWING
F
AN SPEE
D
ECONOMY
1
2
3
TIMER
ON
OFF
CANCEL
SET
COOL
AU
T
O
AU
T
T
O
AU
T
O
F
AN
RESET
CLOCK
OFF/ON
QUIET
TEMP
MODE
POWERFUL
AIR SWING
F
AN SPEE
D
QUIET
1
23
TIMER
ON
OFF
CANCEL
SET
COOL
AUTO
AU
TO
AU
TO
FAN
RESET CLOCK
OFF/ON
Note: The illustrations in this manual are for explanation purposes only and may differ from the
actual unit. It is subject to change without notice for future improvement.
PRODUCT OVERVIEW
■ About
Remote Control Preparation
Indoor Unit
Front panel
Air intake
Auto OFF/ON
1. Pull
out
2. Insert ba
tteries
(AAA or R03)
ENGLISH
button
3. Press CLOCK button
Air
Purifying
filter
Receiver
4. Set
current
time
Air filter
Airflow direction
louver
Indicator
Discharged
air
5. Press again to confirm
• Timer operation will be based on current
time set.
• The batteries can be used for
approximately 1 year.
• The batteries must be recycled or
disposed of properly.
Outdoor Unit
Air inlet (rear)
Air inlet (side)
Air outlet
Remote Control
Transmitter
LCD display
Quiet operation
Operation mode
Airflow direction
adjustment
Temperature setting
Off/On
Economy operation
Powerful operation
Fan speed selection
Timer setting
Memory reset
Troubleshooting
● Operation delayed for a few minutes after restart.
● Sound like water flowing during operation.
● Mist emerges from indoor unit.
● Noisy during operations.
● Remote control/display does not work.
● The unit cannot operate.
● Outdoor unit emits water/steam.
Clock setting
➤ This is a normal self protection function.
➤ Caused by refrigerant flow inside.
➤ Condensation effect due to cooling process.
➤ Installation work could be slanted or front panel isn’t closed properly.
➤ Check whether batteries are correctly inserted or need replacement.
➤ Check whether circuit breaker is tripped or timer is being used correctly.
➤ Condensation or evaporation has occurred at piping surface.
Remote Control Signal
• Make sure it is not obstructed.
• Maximum distances : 10m.
• Certain fluorescent lights may interfere
with signal transmission. Consult your
dealer.
Auto OFF/ON Button
• To operate the unit if the remote
control is misplaced or malfunctioning.
Action
Press once
Press until “beep”
sound
Operation
mode
Automatic
Operation
Cooling
Operation
• To turn OFF, press the Auto OFF/ON
button again.
• To switch the remote control signal
receiving sound off or on.
1. Press until you hear a “beep” sound
and release.
2. Press again until you hear a “beep-
beep” sound and release.
3. Press to switch the sound off or on.
(Long “beep” - OFF; short “beep”
- ON)
3
TEMP
POWERFUL
AIR SWING
FAN SPEED
ECONOMY
1
23
TIMER
ON
OFF
CANCEL
SET
COOL
AUTO
AU
TO
AU
TO
FAN
RESET CLOCK
QUIET
OFF/ON
MODE
■ Operation Details
OFF/ON
HOW TO OPERATE
AUTO - Automatic Operation
• The unit will automatically select the
operation mode according to the room
temperature.
• Once the operation mode is selected,
the unit will operate at the standard
setting temperature as shown:
Room
temperature
73.4°F & aboveCool77°F
Below 73.4°FDry72°F
• You may press or button to
change the standard setting temperature
to “HI” or “LO” as shown:
Operation modeHILO
Cool81°F73°F
Dry75°F68°F
COOL - Cooling Operation
• Enables you to enjoy the cooling effect
at your preferred setting temperature.
• The range of temperature can be
selected from 60°F ~ 86°F.
Operation
mode
Standard
setting
temperature
Auto, Cool, Dry
1
Start the
operation.
2
Select the
desired
operation.
DRY - Soft Dry Operation
• Allows you to set the desired
temperature at low fan speed which
enables you to dehumidify your
surroundings.
• The range of temperature can be
selected from 60°F ~ 86°F.
4
Hint
● To save electricity, close the curtains when using air conditioner to prevent sunlight and heat from coming in.
Troubleshooting
● The room has a peculiar odour.
● Air conditioner does not cool efficiently.
3
Set the
temperature.
● Powerful, Quiet and Economy operations can be activated in
all operation modes.
● Press
button again to stop the operation.
➤ This may be a damp smell emitted by the wall, carpet, furniture or
clothing in the room.
➤ Ensure the temperature has been set correctly.
➤ Ensure windows and doors have been closed properly.
➤ Ensure filters are cleaned or replaced when necessary.
➤ Ensure inlet and outlet vents of the unit have not been obstructed.
TEMP
MODE
AIR SWING
1
23
TIMER
ON
OFF
CANCEL
SET
COOL
AUTO
AU
TO
AU
TO
FAN
RESET CLOCK
OFF/ON
AUTO
ECONOMY
POWERFUL
FAN SPEED
QUIET
AUTO
HOW TO OPERATE
Powerful, Quiet, Economy, Fan Speed,
Air Swing
■ Operation Details
POWERFUL
• To achieve setting temperature quickly. It
will operate for 15 minutes and return to
the previous setting.
ENGLISH
QUIET
Enables
quiet
operation.
AIR SWING
Adjust the
vertical or
horizontal airflow
direction louver.
ECONOMY
Enables
economy
operation.
POWERFUL
Enables
powerful
operation.
FAN SPEED
Select fan speed.
QUIET
• To provide a quiet environment.
ECONOMY
• To save electrical power consumption.
• Use when desired room temperature is
reached.
FAN SPEED
• To provide you with various fan speed
selections.
• There are 3 levels of fan speed in
addition to automatic fan speed.
• Automatic fan speed:
The speed of the indoor fan is
automatically adjusted according to the
operation.
AIR SWING
• To ventilate air in the room.
• There are 5 settings in addition to
automatic vertical airflow direction.
• If automatic vertical airflow direction has
been set, the louver swings up and down
automatically.
● Powerful, Quiet or Economy operations cannot be activated
● Powerful, Quiet or Economy operations can be cancelled by
at the same time.
pressing the respective button again.
Hints
● If you wish to have the cool air blowing directly on you, set the airflow direction downward but not for an excessive length of time, as it
may harm your health.
● Electricity use can be reduced by approximately 10% if you set the temperature 1°F higher than the desired temperature during cooling
operation.
Troubleshooting
● Indoor fan stops occasionally during Automatic Fan
Speed setting.
➤ This is an advanced feature that helps to remove smell from the
surrounding area during operation.
• To ventilate air in the room.
• There are 5 settings in addition to
automatic horizontal airflow direction.
• If automatic
has been set, the louver swings left and
right automatically.
• Please do not adjust the vertical and
horizontal airflow direction louver
manually.
horizontal airflow direction
5
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.