Panasonic CS-C18BKP, CU-C18BKP5, CU-C24BKP5, CU-C18BKP6, CU-C24BKP6 Service Manual

...
1 Features 2 2 Functions
3
3 Product Specifications
6
4 Dimensions
14
5 Refrigeration Cycle Diagram
16
17
7 Wiring Diagram
18
8 Operation Details
19
9 Operating Instructions
29
10 Installation Instructions
34
© 2001 Matsushita Air-Conditioning Corp. Sdn. Bhd. (183914D). All rights reserved. Unauthorized copying and distribution is a violation of law.
CS-C18BKP CU-C18BKP5 CS-C18BKP CU-C18BKP6 CS-C24BKP CU-C24BKP5 CS-C24BKP CU-C24BKP6
11 3-way Valve 44 12 Servicing Information
57
13 Troublesh ooting Guide
61
14 Technical Data
63
15 Exploded View
66
16 Replaceme nt Parts List
67
17 Exploded View
69
18 Replaceme nt Parts List
70
19 Electronic Circuit Diagram
73
Room Air Conditioner
CONTENTS
Page Page
Order No. MAC0111061C0
E25
High Efficiency
Compact Design
Comfort Environment
8 hours of sleep mode operation
Air filter with function to reduce dust and smoke
Wider range of horizontal discharge air
New Automatic air swing and manual adjusted by remote control for horizontal airflow.
Auto Restart
Random auto restart after power failure for safety restart operation
Removable and Washable Front Panel
Remote Control Self-illuminating Button
Catechin Air Purifying Filter
Trap dust, tobacco smoke and tiny particles
Prevent the growth of bacteria and viruses trapped
Solar Refreshing Deodorizing Filter
Remove unpleasant odour from the air
Quality Improvement
Gas leakage protection
Prevent compressor reverse cycle
External OLP to protect compressor (C18BKP6 only) other inner protector
Noise prevention during soft dry operation
Anti-dew Formation Control (Cooling & Soft Dry)
Blue Coated Condenser (Gold Coated Condenser for Panama only)
High resistance to corrosion.
Operation Improvement
Economy mode to reduce electrical power consumption
Powerful mode to reach the desired room temperature quickly
Long Installation Piping
Long piping up to 25 meter
24-hour Timer Setting
1 Features
2
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
2 Functions
Remote Control
Operation OFF / ON
OFF / ON I
Room Temperature Setting
TEMP.
Operation Mode Selection
AUTO
Automatic Operation Mode
COOL
Cooling Operation Mode
DRY
Soft Dry Operation Mode
FAN
Air Circulation Mode
MODE
TIME
Time / Timer Setting
• Hours and minutes setting.
Clock Setting
• Current time setting.
Sleep Mode Operation OFF / ON
SLEEP
Indoor Fan Speed Selection
FAN SPEED
FAN
Low Fan Speed
FAN
Medium Fan Speed
FAN
High Fan Speed
AUTO
Automatic Fan Speed
FAN
Vertical Airflow Direction Control
• 24-hour, OFF / ON Real Timer Setting.
ON-TIMER OFF-TIMER
Timer Operation Selection
SET CANCEL
Timer Operation Set / Cancel
• ON Timer and OFF Timer setting and cancellation.
CLOCK
AIR SWING
Vertical Automatic Airflow Direction Control and Manual Airflow Direction Control (5 stages of adjustment).
Horizontal Automatic Airflow Direction Control and Manual Airflow Direction Control (5 stages of adjustment).
Powerful Mode Operation OFF/ON
POWERFUL
Economy Mode Operation OFF/ON
ECONOMY
Cooling, Soft Dry, Air Circulation Operation.
• Temperature Setting (16°C to 30°C) Automatic Operation
Operation with 2°C higher than standard temperature.
Operation with standard temperature.
Operation with 2°C lower than standard temperature.
Self illuminating
button
3
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
Indoor Unit
Random Auto Restart Control
Operation is restarted randomly after power failure at previous setting mode.
Anti-Freezing Control
Anti-Freezing control for indoor heat exchanger. (Cooling and Soft Dry)
Sleep Mode Auto Control
Indoor Fan operates at Low speed.
Operation stops after 8 hours.
Indoor Fan Speed Control
High, Medium and Low.
Automatic Fan Speed ModeCooling : Fan rotates at Hi, Me and
SLo speed. Deodorizing control is available.
– Soft Dry: Fan rotates at SLo speed.
Deodorizing control is available.
Automatic air swing and manual adjusted by remote control for vertical and horizontal airflow.
Airflow Direction Control
Automatic Operation Button
Press for < 5s to operate Automatic operation mode. (Used when the remote control cannot be used.)
Press continuously for 5s or < 10s to operate Test Run/Pump down. “Beep” sound will be heard at the 5th second. (Used when test running or servicing.)
Press continuously for 10s and above to omit or resume the remote control signal receiving sound. Beep, beep sound will be heard at the 10th second.
AUTO
OFF / ON
Operation Indication Lamps (LED)
POWER
(Green) ........Lights up in operation,
blinks in Automatic Operation Mode judging.
SLEEP
(Orange)........Lights up in Sleep
Mode Operation.
TIMER
(Orange) .......Lights up in Timer
Setting.
POWERFUL
(Orange)..Lights up in Powerful
Mode Operation.
ECONOMY
(Green) ..... Lights up in Economy
Mode Operation.
Operation Mode
Cooling, Soft Dry, Air Circulation and Automatic Mode.
Powerful Operation
Reaches the desired room temperature quickly.
Time Delay Safety Control
Restarting is inhibited for appro. 3 minutes.
Economy Operation
To reduce electrical power consumption.
7 Minutes Time Save Control
Cooling Operation only.
Anti-Dew Formation Control
Anti-Dew Formation Control for indoor unit discharge area.
4
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
Outdoor Unit
To protect compressor from reverse rotation when there is a instantaneous power failure.
60 Secs. Forced Operation Control
Once the compressor is activated, it does not stop within the first 60 secs. However, it stops immediately with remote control stop signal.
Overload Protector
Inner protector.
Compressor Reverse Rotation Protection Control
Outdoor Fan Operation Control
6-pole induction motor (2 speed).
For Cooling or Soft Dry operation
Hi-speed ............. When outdoor
temperature reaches to 31°C.
Lo-speed............. When outdoor
temperature reaches to 29°C.
5
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
3 Product Specifications
Unit CS-C18BK CU-C18BK
Power Source Phase, Voltage, Cycle (1)
(7)
Single, 230 - 220, 50 Hz
(2) Single, 220, 60 Hz (3) Single, 240 - 230, 50 Hz (4) Single, 220, 50 Hz (5)
(6)
Single, 230 - 208, 60 Hz
Cooling Capacity kW (BTU/h) (1)
(3) (7)
5.30 - 5.30 (18,100 - 18,100)
(2) (4)
5.30 (18,100)
(5) (6)
5.20 - 5.20 (17,700 - 17,700)
Moisture Removal l/h (Pint/h) (1)
(2) (3) (7)
2.9 (6.1)
(5) (6)
2.0 (4.2)
Airflow Method OUTLET
INTAKE
SIDE VIEW TOP VIEW
Air Volume Indoor Air (Lo) m3/min (cfm) (1)
(3) (7)
12.8 (450) - 12.8 (450)
(2) (4)
12.8 (450)
(5) (6)
11.4 (400) - 11.4 (400)
Indoor Air (Me) m3/min (cfm) (1)
(3) (7)
13.8 (490) - 13.8 (490)
(2) (4)
13.8 (490)
(5) (6)
12.3 (430) - 12.3 (430)
Indoor Air (Hi) m3/min (cfm) (1)
(3) (7)
14.9 (530) - 14.9 (530)
(2) (4)
14.9 (530)
(5) (6)
13.3 (470) - 13.3 (470)
Indoor Air (SHi) m3/min (cfm) (1)
(3) (7)
15.5 (550) - 15.5 (550)
(2) (4)
15.5 (550)
(5) (6)
13.8 (490) - 13.8 (490)
Noise Level dB (A) (1)
(7)
High 42 - 42, Low 37 - 37 High 55 - 54
(2) (4)
High 42, Low 37 High 54
(3) High 42 - 42, Low 37 - 37 High 56 - 55 (5)
(6)
High 42 - 42, Low 37 - 37 High 56 - 54
6
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
Unit CS-C18BK CU-C18BK
Power level dB (1) 54 - 54 70 - 70
(2) (4) (5) (6) (7)
(3) 54 - 54 71 - 70
Electrical Data Input Power kW (1)
(7)
1.76 - 1.72
(2) (4)
1.72
(3) 1.81 - 1.78 (5)
(6)
1.78 - 1.74
Running Current A (1)
(7)
7.8 - 8.0
(2) (4)
8.0
(5) (6)
7.9 - 8.5
EER W/W (BTU/hW) (1)
(7)
3.01 - 3.08 (10.28 - 10.52)
(2) (4)
3.08 (10.52)
(3) 2.93 - 2.98 (10.00 - 10.17) (5)
(6)
2.9 - 3.0 (9.9 - 10.1)
Starting Current A (1)
(7)
38.0
(2) (5) (6)
47.0
(4) 36.0
Piping Connection Port (Flare piping)
inch inch
G ; Half Union 1/2
L ; Half Union 1/4
G ; 3-way valve 1/2
L ; 3-way valve 1/4
Pipe Size (Flare piping)
inch inch
G ; (gas side) 1/2
L ; (liquid side) 1/4
G ; (gas side) 1/2
L ; (liquid side) 1/4
Drain Hose
Inner diameter mm 12 Length mm 650
Power Cord Length m 1.9
Number of core-wire 3 (1.5 mm2)
Dimensions Height inch (mm) 10 - 13/16 (275) 26 - 31/32 (685)
Width inch (mm) 39 - 9/32 (998) 31 - 1/2 (800) Depth inch (mm) 8 - 9/32 (210) 11 - 13/16 (300)
Net Weight lb (kg) (1)
(3) (4) (7)
24 (11.0) 121 (55.0)
(2) (5) (6)
24 (11.0) 106 (48.0)
Compressor Type Rotary (1 cylinder)
rolling piston type Motor Type Induction (2-poles) Rated Output kW (1)
(3) (4) (7)
1.5
(2) (5) (6)
1.2
7
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
Unit CS-C18BK CU-C18BK
Air Circulation Type Cross-flow Fan Propeller Fan
Material ASHT-18 PC + AES + Glass Fiber 15%
Motor Type Transistor (8-poles) Induction (6-poles)
Input W 44.8 - 53.5 151.2 - 135.7
Rated Output W (1)
(3) (4) (7)
30 72
(2) (5) (6)
30 52
Fan Speed Low rpm (1)
(3) (5) (6) (7)
1,130 - 1,130
(2) (4)
1,130
Medium rpm (1)
(3) (5) (6) (7)
1,220 - 1,220
(2) (4)
1,220
High rpm (1)
(3) (5) (6) (7)
1,320 - 1,320 1,020 - 980
(2) (4)
1,320 980
SuperHigh rpm (1)
(3) (5) (6) (7)
1,370 - 1,370
(2) (4)
1,370
Heat Exchanger Description Evaporator Condenser
Tube material Copper Copper Fin material Aluminium (Pre Coat) Aluminium (Blue/Gold Coat) Fin Type Slit Fin Corrugated Fin Row / Stage (Plate fin configuration, forced draft)
2×15 2×31 FPI 21 18 Size (W × H × L) mm 810 × 315 × 25.4 775.2
754.5
× 651.0 × 25.4
Refrigerant Control Device Capillary Tube Refrigeration Oil (cm3) SUNISO 4GDID or ATMOS
M60 (700)
Refrigerant (R-22) g (oz) (1)
(3) (4) (7)
1,160 (40.9)
(2) (5) (6)
1,240 (43.8)
Thermostat Electronic Control Mechanical Control Protection Device Inner Protector Capillary Tube Length mm 611
Flow Rate l/min 27.0 Inner Diameter mm 2.1
Air Filter Material
Style
P.P.
Honeycomb
Capacity Control Capillary Tube Compressor Capacitor µF, VAC 45 µF, 370VAC Fan Motor Capacitor µF, VAC 3.5 µF, 450VAC
8
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
Note:
Specifications are subject to change without notice for further improvement.
(1) CS-C18BKP/CU-C18BKP5 (Europe).
(2) CS-C18BKP-1/CU-C18BKP6-1 (Panama).
(3) CS-C18BKP-2/CU-C18BKP5-2 (Oceania).
(4) CS-C18BKP-3/CU-C18BKP5-3 (Argentina).
(5) CS-C18BKP-4/CU-C18BKP6-4 (U.S.A).
(6) CS-C18BKP-5/CU-C18BKP6-5 (Canada).
(7) CS-C18BKP-6/CU-C18BKP5-6 (Turkey).
9
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
Unit CS-C24BK CU-C24BK
Power Source Phase, Voltage, Cycle (1)
(7)
Single, 230 - 220, 50 Hz
(2) Single, 220, 60 Hz (3) Single, 240 - 230, 50 Hz (4) Single, 220, 50 Hz (5)
(6)
Single, 230 - 208, 60 Hz
Cooling Capacity kW (BTU/h) (1)
(7)
7.03 - 7.03 (24,000 - 24,000)
(2) (4)
7.03 (24,000)
(3) 6.85 - 6.85 (23,400 - 23,400) (5)
(6)
6.82 - 6.82 (23,200 - 23,200)
Moisture Removal l/h (Pint/h) (1)
(4) (7)
4.0 (8.5)
(3) 3.9 (8.2) (5)
(6)
3.1 (6.6)
Airflow Method OUTLET
INTAKE
SIDE VIEW TOP VIEW
Air Volume Indoor Air (Lo) m3/min (cfm) (1)
(3) (7)
13.9 (490) - 13.9 (490)
(2) (4)
13.9 (490)
(5) (6)
12.4 (440) - 12.4 (440)
Indoor Air (Me) m3/min (cfm) (1)
(3) (7)
15.4 (540) - 15.4 (540)
(2) (4)
15.4 (540)
(5) (6)
13.8 (490) - 13.8 (490)
Indoor Air (Hi) m3/min (cfm) (1)
(3) (7)
16.9 (600) - 16.9 (600)
(2) (4)
16.9 (600)
(5) (6)
15.1 (530) - 15.1 (530)
Indoor Air (SHi) m3/min (cfm) (1)
(3) (7)
17.5 (620) - 17.5 (620)
(2) (4)
17.5 (620)
(5) (6)
15.6 (550) - 15.6 (550)
Noise Level dB (A) (1)
(7)
High 46 - 46, Low 40 - 40 High 60 - 59
(2) (4)
High 46, Low 40 High 59
(3) High 46 - 46, Low 40 - 40 High 61 - 60 (5)
(6)
High 46 - 46, Low 40 - 40 High 61 - 59
Power level dB (1) 59 - 59 74 - 74
(2) (4) (5) (6) (7)
(3) 59 - 59 75 - 74
10
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
Unit CS-C24BK CU-C24BK
Electrical Data Input Power kW (1)
(7)
2.60 - 2.41
(2) 2.55 (3) 2.64 - 2.54 (4) 2.41 (5)
(6)
2.68 - 2.64
Running Current A (1)
(7)
12.4 - 11.8
(2) 12.0 (4) 11.8 (5)
(6)
12.1 - 13.1
EER W/W (BTU/hW) (1)
(7)
2.70 - 2.92 (9.23 - 9.96)
(2) 2.76 (9.41) (3) 2.60 - 2.70 (8.86 - 9.21) (4) 2.92 (9.96) (5)
(6)
2.5 - 2.6 (8.6 - 8.7)
Starting Current A (1)
(7)
65.0
(2) (4) (5) (6)
63.0
Piping Connection Port (Flare piping)
inch inch
G ; Half Union 5/8
L ; Half Union 1/4
G ; 3-way valve 5/8
L ; 3-way valve 1/4
Pipe Size (Flare piping)
inch inch
G ; (gas side) 5/8
L ; (liquid side) 1/4
G ; (gas side) 5/8
L ; (liquid side) 1/4
Drain Hose
Inner diameter mm 12 Length mm 650
Power Cord Length m 1.9
Number of core-wire 3 (2.5 mm2)
Dimensions Height inch (mm) 10 - 13/16 (275) 26 - 31/32 (685)
Width inch (mm) 39 - 9/32 (998) 31 - 1/2 (800) Depth inch (mm) 8 - 9/32 (210) 11 - 13/16 (300)
Net Weight lb (kg) (1)
(3) (4) (7)
24 (11.0) 132 (60.0)
(2) (5) (6)
24 (11.0) 133 (60.5)
Compressor Type Rotary (1 cylinder) rolling
piston type Motor Type Induction (2-poles) Rated Output kW (1)
(4) (7)
2.2
(2) (5) (6)
1.8
11
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
Unit CS-C24BK CU-C24BK
Air Circulation Type Cross-flow Fan Propeller Fan
Material ASHT-18 PC + AES + Glass Fiber 15%
Motor Type Transistor (8-poles) Induction (6-poles)
Input W 44.8 - 53.5 190.0 - 171.3
Rated Output W (1)
(3) (4) (7)
30 108
(2) (5) (6)
30 118
Fan Speed Low rpm (1)
(3) (5) (6) (7)
1,220 - 1,220
(2) (4)
1,220
Medium rpm (1)
(3) (5) (6) (7)
1,350 - 1,350
(2) (4)
1,350
High rpm (1)
(3) (5) (6) (7)
1,480 - 1,480 1,180 - 1,155
(2) (4)
1,480 1,155
SuperHigh rpm (1)
(3) (5) (6) (7)
1,530 - 1,530
(2) (4)
1,530
Heat Exchanger Description Evaporator Condenser
Tube material Copper Copper Fin material Aluminium (Pre Coat) Aluminium (Blue/Gold Coat) Fin Type Slit Fin Corrugated Fin Row / Stage (Plate fin configuration, forced draft)
2 × 15 2 × 26 FPI 21 18 Size (W × H × L) mm 810 × 315 × 25.4 769.2
732.9
× 660.4 × 44.0
Refrigerant Control Device Capillary Tube
Refrigeration Oil (cm3) SUNISO 4GDID or ATMOS
M60 (1,130)
Refrigerant (R-22) g (oz) (1)
(3) (4) (5) (6) (7)
1,730 (61.1)
(2) 1,700 (60.0) Thermostat Electronic Control Mechanical Control Protection Device Inner Protector Capillary Tube Length mm 675
Flow Rate l/min 25.5 Inner Diameter mm 2.1
Air Filter Material
Style
P.P.
Honeycomb
Capacity Control Capillary Tube Compressor Capacitor µF, VAC 45 µF, 370VAC Fan Motor Capacitor µF, VAC 3.5 µF, 450VAC
12
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
Note:
Specifications are subject to change without notice for further improvement.
(1) CS-C24BKP/CU-C24BKP5 (Europe).
(2) CS-C24BKP-1/CU-C24BKP6-1 (Panama).
(3) CS-C24BKP-2/CU-C24BKP5-2 (Oceania).
(4) CS-C24BKP-3/CU-C24BKP5-3 (Argentina).
(5) CS-C24BKP-4/CU-C24BKP6-4 (U.S.A).
(6) CS-C24BKP-5/CU-C24BKP6-5 (Canada).
(7) CS-C24BKP-6/CU-C24BKP5-6 (Turkey).
13
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
4 Dimensions
14
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
15
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
5 Refrigeration Cycle Diagram
16
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
6 Block Diagram
17
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
7 Wiring Diagram
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
18
Cooling in operation according to Remote Control setting.
Time Delay Safety Control (3 minutes)
7 minutes Time Save Control
Anti-Freezing Control
If the temperature of the indoor heat exchanger falls continuously below 2°C for 4 minutes or more, the compressor turns off to protect the indoor heat exchanger from freezing. The fan speed setting remains the same.
Compressor will restart again when the indoor heat exchanger temperature rises to 10°C (Recovery).
3 minutes waiting of Time Delay Safety Control is valid for Cooling Operation.
Compressor Reverse Rotation Protection Control
Anti-Dew Formation Control
8 Operation Details
8.1. Cooling Mode Operation
When the compressor is stopped by Remote Control, it restarts after 3 minutes when the Remote Control is turned ON.
When the setting temperature is reached during cooling operation, the compressor stops and it will not start for 3 minutes.
The compressor will start automatically if it has stopped for 7 minutes even if the room tempe rature is between the compressor ON temperature and OFF temperature.
If the compressor is operating continuously for 5 minutes or longer and the temperature difference between intake air and indoor heat exchanger is 2.5°C or less for 2 minutes, compressor will stop and restart automatically. (Time Delay Safety Control is valid)
T = Intake air temperature - Indoor heat exchanger temperature
This is to protect reverse rotation of the compressor when there is a instantaneous power failure.
Purpose is to prevent dew formation on indoor unit air discharge area.
When the following conditions occur for 30 minutes continuously, anti-dew formation is controlled by indoor fan speed shift to low (Changed to Lo
+
):
Indoor intake air temperature is more than 24°C and less than 30°C.
Remote Control setting temperature is less than 25°C.
Compressor is on.
Cooling operation mode.
Indoor Fan motor operate at Low fan speed.
This control is cancelled immediately when above condition is changed.
19
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
Automatic Fan Speed Mode
Cooling Operation Time Diagram
When Autom atic Fan Speed is selected at Remote Control during cooling operation.
Fan speed rotates in the range of Hi to Me.
Deodorizing Control.
20
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
Time Delay Safety Control
Anti-Freezing Control
Compressor Reverse Rotation Protection Control
Anti-Dew Formation Control
Automatic Fan Speed Mode
8.2. Soft Dry Mode Operation
The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and then Soft Dry operation will start.
During Soft Dry operation, the Indoor Fan will operate at SLo speed.
Once room temperature reaches below Soft Dry OFF temperature. Indoor Fan, Compressor and Outdoor Fan stop for 6 minutes.
Once the compressor stops, it will not start for 3 minutes during Cooling operation.
Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressor stops.)
Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6 minutes waiting is valid during compressor stops.)
Same as Anti-Dew Formation Control for Cooling Mode operation.
When Autom atic Fan Speed is selected at Remote Control during Soft Dry operation.
Fan speed off and on at SLo speed.
Deodorizing Control.
21
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
Soft Dry Operation Time Diagram
22
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
Air Circulation Mode Operation Time Diagram
Standard for Determining Operation Mode
8.3. Air Circulation Mode Operation
When the temperature near the ceiling reaches the setting temperature, Air Circulation Mode operation commences at low airflow volume. It stops when the temperature drops to 2°C below the setting temperature.
8.4. Automatic Mode Operation
Indoor fan operates at SLo fan speed for 20 seconds.
After judging indoor air temperature, the operation mode is determined and operation continued at the mode determined.
After the operation mode has been determined, the mode does not change. However, Soft Dry mode operation includes Cooling mode operation.
Room temperature adjustment. The following are added to the setting temperature specified as above.
The mode judging temperature and standard setting temperature can be increased by 2°C, by open the circuit of JX1 at indoor electronic controller.
23
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
Cooling or Soft Dry Operation
Purpose is to obtain a comfortable room temperature while sleeping. When you press the SLEEP Mode, the following movement will start to avoid overcooling.
Sleep shift operation starts, when the room temperature reaches the setting temperature or after 1 hour of operation.
The setting temperature will be risen by 0.5°C at the start of operation and by 0.5°C one hour later.
The airflow volume will automatically change to Low fan speed.
Sleep Mode operation time is 8 hours, the operation will be stop after 8 hours.
When used together with the Timer, the Timer has priority.
8.5. Sleep Mode Auto Operation
8.6. Powerful Mode Operation
Purpose of this operation is to obtain the setting temperature quickly.
When the Powerful Mode is set, the set temperature will be automatically decreased 3°C against the present setting temperature (Lower temperature: 16°C).
This operation automatically will be running under SHi Fan Speed (Cooling), SLo Fan Speed (Soft Dry).
Vertical Airflow Direction:-
-In“Manual” setting, the vane will automatically swing down 10° lower than previous setting.
-In“Auto” setting, the vane will automatically swing up and down. However the lower limit will be shifted 10° downward.
Powerful Mode will operate for 15 minutes only, after that it will shift back to previous operation mode.
Powerful Mode will stop if:-
- Powerful mode button is pressed again.
- Stopped by ON / OFF switch.
- Timer OFF activates.
- Economy mode button is pressed.
- Sleep mode is pressed.
- Operation mode button is changed.
8.7. Economy Mode Operation
Purpose of this operation is to save or reduced electrical power consumption of the room air conditioner.
When the Economy Mode is set, the set temperature will be automatically increased 0.5°C against the preset setting temperature (Higher temperature: 30°C).
This operation automatically will be running under SLo Fan Speed.
Vertical Airflow Direction:­In “Manual” or “Auto” setting, the vane will automatically change to Auto Air Swing.
Economy Mode will stop if:-
- Economy Mode button is pressed again.
- Stopped by ON / OFF switch.
- Timer OFF activates.
- Powerful mode button is pressed.
- Auto or Manual air swing button is pressed.
- Fan Speed control button is pressed.
- Sleep Mode button is pressed ON.
- Operation Mode is changed.
24
CS-C18BKP CU-C18BKP5 / CS-C18BKP CU-C18BKP6 / CS-C24BKP CU-C24BKP5 / CS-C24BKP CU-C24BKP6
Loading...
+ 55 hidden pages