PANASONIC CUA125KH, CSA125KH, CSA95KH, CUA95KH User Manual

Page 1
CONTENTS
Before use
: FEATURES....................................................................... 3
:
: SAFETY PRECAUTIONS........................................... 4 – 6
Installation Precautions
Operation Precautions
:
Indoor Unit
When the front panel is opened
Outdoor Unit
Accessories
Remote Control
When the remote control is opened
How to use the remote control
When the back cover is opened
:
How to use
: PREPARATION BEFORE OPERATION ............... 11 – 12
Indoor Unit
Remote Control
Inserting batteries
Setting the clock
About the batteries
:
: HOW TO OPERATE............................................... 13 – 14
Automatic • Heating • Cooling • Soft Dry
Operation details
Adjusting Airflow Direction and Fan Speed
Operation details
:
: SETTING THE TIMER ............................................ 15 – 16
Recommended Setting of Timer
:
1
Page 2
If necessary
ENGLISH
: CONVENIENCE OPERATION ............................... 17 – 18
Sleep Mode
Operation details
Economy or Powerful Mode
Operation details
:
: CARE AND MAINTENANCE ................................. 19 – 22
Cleaning the Indoor Unit and Remote Control
Cleaning the Air Filter
Cleaning the Front Panel
Removing the front panel
Fixing the front panel
Cleaning the front panel
Replacing the Air Purifying Filters
Removing the air purifying filters
Reinstalling the air purifying filters
Pre-season Inspection
When the Air Conditioner is Not Used for an Extended
Period of Time
Recommended Inspection
:
: TROUBLESHOOTING ........................................... 23 – 24
Normal Operation
Abnormal Operation
Call the Dealer Immediately
:
: HELPFUL INFORMATIONS........................................... 25
:
: ENERGY SAVING AND OPERATION HINTS............... 26
:
2
Page 3
FEATURES
SELF-ILLUMINATING BUTTON
For your convenience to operate in the dark.
(Refer page 9)
AUTOMATIC OPERATION
Sence intake air temperature every hour to select the optimum mode.
(Refer page 13)
SLEEP MODE
Prevent the room from getting too hot or too cold while you are sleeping.
(Refer page 17)
ECONOMY MODE
To reduce electrical power consumption.
(Refer page 18)
POWERFUL MODE
Reaches the desired room temperature quickly.
(Refer page 18)
REMOVABLE FRONT PANEL
For quick and easy cleaning (washable).
(Refer page 20)
CATECHIN AIR PURIFYING FILTER
Filter that can trap dust, tabacco smoke and tiny particles in the room. It can also prevent the growth of bacteria and viruses trapped in this filter.
(Refer page 21)
AUTO RESTART CONTROL
Automatically restart the unit after power failure.
(Refer page 25)
Thank you for purchasing a National Room Air Conditioner.
Note: Before using your air-conditioner, please read this operating instructions carefully and keep it for future reference.
3
Page 4
SAFETY PRECAUTIONS
Before operating, please read the following “Safety Precautions” carefully.
To prevent personal injury, injury to others and property damage, the following instructions must be followed.
Incorrect operation due to failure to follow instructions will cause harm or damage, the seriousness of which is classified as follows :
ENGLISH
! Warning /
This sign warns of death or serious injury.
The instructions to be followed are classified by the following symbols :
This symbol (with a white background) denotes
an action that is PROHIBITED.
! Caution /
This sign warns of damage to property.
OFF
These symbols (with a black background)
denote actions that are COMPULSORY.
Installation Precautions /
! Warning /
Do not install, remove and reinstall the unit yourself.
Improper installation will cause leakage, electric shock or fire. Please consult an authorized dealer or specialist for the installation work.
! Caution /
This room air conditioner must be earthed.
Improper grounding could cause electric shock.
Do not install the unit in a place where there may
be explosive gas leaks.
Gas leaks near the unit could cause fires.
Ensure that the drainage piping is connected
properly.
Otherwise, water will leak out.
4
Page 5
Operation Precautions /
! Warning /
This sign warns of death or
serious injury.
Do not insert plug to operate the unit. Do not pull out plug to stop the unit.
Plug in properly.
Do not share outlet.
Do not repair by yourself.
Do not operate with wet hands.
Use specified power cord.
Do not damage or modify the power cord.
OFF
If abnormal condition (burnt smell, etc) occurs, switch off and unplug the power supply.
TIMER
SLEEP
POWER
ECONOMY
POWERFUL
Do not insert finger or other objects into the indoor or outdoor units.
Do not expose directly to cool air for a long period.
5
Page 6
ENGLISH
OFF
Switch off the power supply if the unit is not used for a long period.
Do not pull the cord to disconnect the plug.
Switch off the power supply before cleaning it.
Do not wash the unit with water.
Do not use for other purpose such as preservation or etc.
! Caution /
This sign warns of injury.
TIMER
SLEEP
POWER
ECONOMY
POWERFUL
Do not use any combustible equipment at airflow direction.
Ventilate the room regularly.
Do not sit or place anything on the outdoor unit.
Pay attention as to whether the installation rack is damaged due to long period of usage.
6
Page 7
NAME OF EACH PART
Indoor Unit
Front Panel
Horizontal Airflow Direction Louver (Manually adjusted)
Vertical Airflow Direction Louver
Economy/Powerful Indicators Economy - Green Powerful - Orange
Air Intake Vent
Air Outlet Vent
POWER
TIMER
SLEEP
POWER
ECONOMY
POWERFUL
SLEEP
TIMER
Power Supply Cord
Panel Opener
Signal Receptor
Operation Indicators
POWER : Green
SLEEP : Orange
TIMER : Orange
ECONOMY
When the front panel is opened
Front Panel
Air Purifying Filter
Air Filters
POWERFUL
Auto Operation Button
TIMER
POWER
SLEEP
ECONOMY
POWERFUL
Tab for Front Panel
7
Page 8
Outdoor Unit Accessories
CU-A95KH
AUTO
COOL
Air Intake Vents
(Rear)
Piping
POWERFUL
OFF/ON
ENGLISH
TEMP
(Side)
Air Outlet Vents
CU-A125KH
Air Intake Vents
(Side)
Connecting cable
Drain Hose
Ground Terminal (Inside Cover)
(Rear)
Connecting cable
Drain Hose
Remote Control
Remote Control Holder
Two RO3 dry-cell batteries or
equivalent
Air Outlet Vents
Ground Terminal (Inside Cover)
Piping
Air Purifying Filters
(Catechin Air Purifying Filter)
8
Page 9
Remote Control
Operation Display
Signal Transmitter
OFF/ON Button
COOL
AUTO
(Self-illuminating Button)
TEMP
Powerful Mode Operation Button
POWERFUL
OFF/ON
When the remote control cover is opened
Operation Display
Room Temperature Setting Button (Self-illuminating Button)
Fan Speed Selection Button
Manual Airflow Direction Selection Button
Time-Setting Button
Sleep Mode Operation Button
Timer Cancellation Button
OFF
SLEEP
ON
AM PM
3
CANCEL
SWING
AUTO
AM PM
2
AUTO FAN
AIR
1
ON OFF
SET
HEAT
COOL
AUTO
AIR SWING
MANUAL
TIMER
Operation Mode Selection Button
Clock Button
HI
AUTO
LO
DRY
MODE
ECONOMY
FAN SPEED
CLOCK
Economy Mode Operation Button
Auto Airflow Direction Button
OFF-TIMER Button
ON-TIMER Button
Timer Set Button
9
Page 10
How to use the remote control
ENGLISH
Notes /
Do not throw or drop
Do not get it wet
Certain type of fluorescent lamps may affect signal reception. Consult your dealer.
POWER
SLEEP
TIMER
ECONOMY
POWERFUL
Maximum distance : 10 m
Make sure it is not obstructed.
Aim at the signal receptor.
When the back cover is opened
Signal receptor
Signal received sound. One short beep or one long beep.
Reset points
short to clear the memory
OPEN
10