M
ulit System Outdoor Submittal Data
CU-5E36QBU-5
Multi System Outdoor Unit
Job Name: Location: Engineer: Submitted to: Submitted by: Reference:
General Data
Power (V/P/Hz) 230/208/1/60
Minimum Circuit Ampacity (A) 30 Maximum Overcurrent Protection (A)
Compressor DC Twin Rotary (Inverter Driven)
No. Used 1 Output Power (W) 1.30K
Fan Type Propeller Motor Type DC Motor (8 poles) Output Power (W) 90 Airflow (CFM) Cooling/Heating 2,512 Cooling / 2,475 Heating
Coil Type Aluminum (Blue Coated) Fin Type - Pipe Type Corrugated Fin Coil Type Aluminum Fin & Copper Pipe Fin Type - Pipe Type Corrugated Fin Rows - F.P.I. 2/19 Tube Size (in) 3/8”
45
Approval: Date: Construction: Unit#: Drawing#:
Refrigerant R410A
R410a Pre Charge 120 oz Refrigerant Control Electronic Expansion Valve Refrigerant Tubing Connections Flare Line Length, Max (ft.) 262.4 Elevation Difference, Max (ft.) 49.2’ Line Size (in. O.D. Discharge) 1/4" x 5 Line Size (in. O.D. Suction) 3/8" x 5 Pre-charge, tube length @ shipment 147.6’
Dimensions (HxWxD)
Outdoor Unit (Uncrated) (in.) 39-11/32 x 37-1/32 x 13-13/32
Weight (lbs.)
(Outdoor) Net 183 lbs
Performance Data @ ARI Standard Conditions (208/230V)
High Heat @ 47F 37,800 Low Heat @ 17F 28,000
Cooling
Total Capacity (BTU/H) 36,000 (9,900 - 39,000) Sensible Capacity (BTU/H) 33,840
Latent Capacity (BTU/H) 2,160 SEER 18.5 Amps (A) 19.0-17.2 Max. Amps (A) 21.3 Power Inputs (KW) 3.75 Max. Inputs (W) 3,750 Outdoor Sound Rating (dB-A) 55
Heating
Total Capacity (BTU/H) 37,800 (11,600-49,500) HSPF 10 Amps (A) 14.8 - 13.4 Power Inputs (W) 2,900 Outdoor Sound Rating (dB-A) 55
Operating Range
Cooling (Max) Cooling (Min) 14F DB/ - WB Heating (Max) 75.2F DB/64F WB Heating (Min)
114F DB/78F WB
-5F DB/-6.8F WB
3. Dimensions
Dimensions
Panasonic North America Air Conditioning Division
1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon