Me (Cool/Heat)rpm1,000 / 1,040—
Hi (Cool/Heat)rpm1,200 / 1,270790
Tube materialCopperCopper
Fin materialAluminium (Pre Coat)Aluminium (Pre Coat)
Fin TypeSlit FinCorrugated Fin
Row / Stage(Plate fin configuration, forced draft)
FPI2316.5
Size (W × H × L)mm640 × 304 × 25.4 + 12.7725.8
Lengthmm——
Inner Diametermm——
Style
2.0 m
2 rows / 11 stages,
1 row / 4 stages
P.P.
Honeycomb
2
—
—
2 rows / 24 stages
× 504 × 36.4
694.6
—
•
•
Specifications are subject to change without notice for further improvement.
• •
7
CS-TE9DKE CU-TE9DKE / CS-TE 12DKE CU-TE12D KE
UnitCS-TE12DKECU-TE12DKE
Cooling CapacitykW
kcal/h
BTU/h
Heating CapacitykW
kcal/h
BTU/h
Moisture Removall/h
Pint/h
Power SourcePhase
V
Cycle
Airflow MethodOUTLET
INTAKE
3.50 (0.60 - 4.00)
3,010 (520 - 3,440)
11,950 (2,050 - 13,600)
4.80 (0.60 - 6.50)
4,130 (520 - 5,590)
16,400 (2,050 - 22,200)
2.0
(4.2)
Single
230/240
50
SIDE VIEWTOP VIEW
Air VolumeIndoor Air (Lo)m3/min (cfm)Cooling; 6.1 (210)—
RatedOutputW—1100
Air CirculationTypeCross-flow FanPropeller Fan
MaterialAS + Glass Fiber 30%P.P
MotorTypeTransistor (8-poles)Transistor (8-poles)
InputW—65.9
Rate OutputW3040
Fan SpeedLo (Cool/Heat)rpm880 / 1,100—
Me (Cool/Heat)rpm1,100 / 1,230—
Hi (Cool/Heat)rpm1,310 / 1,410790
Heat ExchangerDescriptionEvaporatorCondenser
Tube materialCopperCopper
Fin materialAluminium (Pre Coat)Aluminium (Pre Coat)
Fin TypeSlit FinCorrugated Fin
Row / Stage(Plate fin configuration, forced draft)
2 rows / 11 stages,
1 row / 4 stages
FPI2116.5
Size (W × H × L)mm640 × 304 × 25.4 + 12.7725.8
Refrigerant Control Device—Expansion valve
Refrigeration Oil(c.c)—RB68A (400)
Refrigerant (R410A)g (oz)—1,030 (36.3)
ThermostatElectronic ControlElectronic Control
Protection DeviceElectronic ControlElectronic Control
Lengthmm——
Capillary TubeFlow Ratel/min——
Inner Diametermm——
Air FilterMaterial
Style
P.P.
Honeycomb
2 rows / 24 stages
× 504 × 36.4
694.6
—
•
•
Specifications are subject to change without notice for further improvement.
• •
9
CS-TE9DKE CU-TE9DKE / CS-TE 12DKE CU-TE12D KE
4 Dimensions
4.1. Indoor Unit
10
4.2. Outdoor Unit
CS-TE9DKE CU-TE9DKE / CS-TE 12DKE CU-TE12D KE
11
CS-TE9DKE CU-TE9DKE / CS-TE 12DKE CU-TE12D KE
5 Refrigeration Cycle Diagram
12
6 Block Diagram
CS-TE9DKE CU-TE9DKE / CS-TE 12DKE CU-TE12D KE
13
CS-TE9DKE CU-TE9DKE / CS-TE 12DKE CU-TE12D KE
7 Wiring Diagram
7.1. CS-TE9DTE / CS-TE12DKE
14
7.2. CU-TE9DKE / CU-TE12DKE
CS-TE9DKE CU-TE9DKE / CS-TE 12DKE CU-TE12D KE
15
CS-TE9DKE CU-TE9DKE / CS-TE 12DKE CU-TE12D KE
8 Electronic Circuit Diagram
8.1. Indoor Unit / Remote Controller
16
8.1.1. Printed Circuit Board
CS-TE9DKE CU-TE9DKE / CS-TE 12DKE CU-TE12D KE
17
CS-TE9DKE CU-TE9DKE / CS-TE 12DKE CU-TE12D KE
8.2. Outdoor Unit
18
8.2.1. Printed Circuit Board
CS-TE9DKE CU-TE9DKE / CS-TE 12DKE CU-TE12D KE
19
CS-TE9DKE CU-TE9DKE / CS-TE 12DKE CU-TE12D KE
9 Operation Details
9.1. BASIC FUNCTION
Inverter control, which equipped with a microcomputer in determining the most suitable operating mode as time passes,
automatically adjusts output power for maximum comfort always. In order to achieve the suitable operating mode, the
microcomputer maintains the set temperature by measuring the temperature of the environment and performing temperature
shifting. The compressor at outdoor unit is operating following the frequency instructed by the microcomputer at indoor unit that
judging the condition according to internal setting temperature and intake air temperature.
9.1.1. Internal Setting Temperature
Once the operation starts, remote control setting temperature will be taken as base value for temperature shifting processes.
These shifting processes are depending on the air conditioner settings and the operation environment. The final shifted value
will be used as internal setting temperature and it is updated continuously whenever the electrical power is supplied to the unit.
Mode within 60 Minutes from Start-up:Temperature Shift (°C)
Cooling/Soft Dry-1.0
Heating+2.0
CS-TE9DKE CU-TE9DKE / CS-TE 12DKE CU-TE12D KE
TE9DKETE12DKE
30 X 380.000.00
23 X 300.000.00
X 230.000.00
17 X 210.000.00
9 X 170.000.00
5 X 9+0.50+1.00
1 X 5+1.00+1.25
X 1+1.50+2.00
Hi, Me-, Me, Me+, Auto+0.25 (TE9DKE), +0.50
(TE12DKE)
9.2. Indoor Power Relay Control
The Power Relay turns on under the followin g conditions.
1. For three minutes, when plugged in the A/C or the Error Reset button on remote controller is pressed.
2. During Installation Check Mode and following for three minutes after checking.
3. During On-timer sampling and during Preliminary operation.
4. During Operation and following for three minutes after the operation is stopped.
5. During Auto Operation, Test run, Forced Heating or Odour Removal Operation and following for three minutes after the
operation is stopped.
9.3. Room Air Temperature Control (Compressor Control)
Operating frequency of a compressor is decided according to temperature differences between remote controller setting and
room temperatures. A relative method which gives frequency changes, based on the decided frequency, will provide you with
comfortable room environment that is not affecte d by operating conditions.
9.3.1. Cooling Operation
9.3.1.1. Thermostat Control
•
•
[Intake Air Temp. - Remote Controller Setting Temp.] >
• •
[Thermostat-OFF Temp. +0.5 °C]
Operated in corresponding frequency.
•
•
Frequency is decided after a completion of the starting
• •
control (in 60 seconds).
•
•
When Room Temp. is below [Thermostat-OFF Temp.]
• •
continuously for 3 minutes or more, it turns to ThermostatOFF operation.
CoolingPowerTE9DKETE12DKE
Intake Air Temp.
Difference (°C)
(-1.00)OFF—-—-
Maximum2.7kW4.0kW
Rated2.5kW3.6kW
Intermediate~~
Minimum0.8kW0.8kW
21
CS-TE9DKE CU-TE9DKE / CS-TE 12DKE CU-TE12D KE
9.3.2. Dry Operation
9.3.2.1. Thermostat Control
•
•
[Intake Air Temp. - Remote Controller Setting Temp.] >
• •
[Thermostat-OFF Temp. +0.5 °C]
Operated in corresponding frequency.
•
•
Frequency is decided after a completion of the starting
• •
control (in 60 seconds).
•
•
When Room Temp. is below [Thermostat-OFF Temp.]
• •
continuously for 3 minutes or more, it turns to ThermostatOFF operation.
•
•
When room temperature almost comes to Thermostat-OFF
• •
Temp., the operation turns to the Minimum power & fan
speed: SSLo.
DryPowerTE9DKETE12DKE
Intake Air Temp.
Difference (°C)
(-2.50)OFF——
Maximum2.7kW4.0kW
Rated2.5kW3.6kW
Intermediate~~
Minimum0.8kW0.8kW
9.3.3. Heating Operation
9.3.3.1. Thermostat Control
•
•
[Intake Air Temp. - Remote Controller Setting Temp.] >
• •
[Thermostat-OFF Temp. +0.5 °C]
Operated in corresponding frequency.
•
•
Frequency is decided after a completion of starting control
• •
(in 60 seconds).
•
•
When Room Temp. is below Thermostat-OFF Temp.
• •
continuously for 3 minutes or more, it turns to ThermostatOFF operation.
•
•
When room temperature almost comes to Thermostat-OFF
• •
Temp., the operation turns to the Maximum power.
HeatingPowerTE9DKETE12DKE
Intake Air Temp.
Difference (°C)
(+1.00)Maximum4.6kW6.2kW
OFF——
Minimum0.8kW0.8kW
Intermediate~~
Rated3.5kW4.5kW
22
CS-TE9DKE CU-TE9DKE / CS-TE 12DKE CU-TE12D KE
9.4. Airflow Direction Control
Vertical louver is controlled with Vertical Airflow Direction button on remote controller and by operation conditions, as shown in the
table below.
9.4.1. Vertical Airflow Louver Angle
Cooling and Dry Operations
Airflow Direction AutoAirflow Direction Setting
Manual OperationVertical Auto OperationPowerful-ON
•
•
The louver is fixed at five-level setting
• •
•
•
It swings when airflow direction is set with
• •
remote controller.
•
•
It does not swing while indoor fan is
• •
stopped. (It is fixed at the upper limit.).
position when the airflow direction is set with
remote controller.
Heating Operation
Airflow Direction AutoAirflow Direction Setting
Fixed by Heat Exchanger TemperaturePowerful OperationRemote Control
•
•
When Heat Exchanger Temperature is less
• •
than 33°C
•
•
When Heat Exchanger Temperature is
• •
between 33°C (, incl.) and 127°C
Airflow Direction AutoAirflow Direction Setting
Odour Removal Control
•
•
When Heat Exchanger Temperature is less
• •
than 33°C
•
•
When Heat Exchanger Temperature is
• •
between 33°C (, incl.) and 127°C
•
•
The louver is fixed at five-level setting
• •
position when the airflow direction is set with
remote controller.
•
•
The vertical louver is fully opened and move to the setting position when the unit is turned on with the remote controller.
• •
•
•
The vertical louver remains open position when the unit is turned off during operation.
• •
•
•
The horizontal louver is manually operated.
• •
23
CS-TE9DKE CU-TE9DKE / CS-TE 12DKE CU-TE12D KE
9.5. Quiet operation (Cooling Mode / Cooling area of Dry Mode)
A. Purpose
To provide quiet cooling operation compare to normal operation.
B. Control condition
a. Quiet operation start condition
•
•
When “quiet” button at remote control is pressed.
• •
Quiet LED illuminates.
b. Quiet operation stop condition
1. When one of the following conditions is satisfied, quiet operation stops:
a. Powerful button is pressed.
b. Stop by OFF/ON switch.
c. Timer “off” activates.
d. When change mode to ION only mode.
2. When quiet operation is stopped, operation is shifted to normal operation with previous setting.
3. When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
4. When operation mode is changed, quiet operation is shifted to quiet operation of the new mode, except ION only mode.
5. During quiet operation, if timer “on” activates, quiet operation maintains.
6. After off, when on back, quiet operation is not memorised.
C. Control contents
1. Fan speed is changed from normal setting to quiet setting of respective fan speed.
This is to reduce sound of Hi, Me, Lo for 3dB.
2. Fan speed for quiet operation is -100 rpm from setting fan speed.
9.5.1. Quiet operation under Soft Dry operation (Dry area at Dry Mode)
Automatic Fan Speed (Dry operation)
Manual Fan Speed (Dry operation)
24