Panasonic CU-C12DKU, CS-C12DKU, CS-C9DKU, CU-C9DKU User Manual

Order No. MAC0502033C1
Air Conditioner
CS-C9DKU CU-C9DKU CS-C12DKU CU-C12DKU
CONTENTS
Page Page
1 Features 2
2 Functions
3 Product Specifications
3.1. CS-C9DKU CU-C9DKU
3.2. CS-C12DKU CU-C12DKU
4 Dimensions
4.2. Outdoor Unit
5 Refrigeration Cycle Diagram
6 Block Diagram
7 Wiring Diagram
8 Operation Details
8.1. Cooling Operation
8.2. Soft Dry Operation
8.3. Automatic Operation
8.4. Operation Control
10
10
11
12
13
14
15
15
16
17
18
3
6
6
8
8.5. Indoor Fan Speed Control 21
8.6. Outdoor Fan Speed Control
8.7. Vertical Airflow Direction Control
8.8. Horizontal Airflow Direction Control
8.9. Powerful Operation
8.10. Quiet Operation
8.11. Timer Control
8.12. Random Auto Restart Control
8.13. Remote Control Signal Receiving Sound
8.14. Economy Mode Operation
9 Operating Instructions
10 Installation Instructions
10.1. Safety Precautions
10.2. Attached accessories
10.3. Select the best location
10.4. Indoor/Outdoor Unit Installation Diagram
© 2005 Panasonic HA Air-Conditioning (M) Sdn Bhd (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law.
23
23
24
24
25
26
26
26
27
28
34
34
36
36
36
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
10.5. Indoor unit 37
10.6. Outdoor unit
11 2-way, 3-way Valve
11.1. Evacuation of Installation
11.2. Pumping down
11.3. Evacuation of Re-installation
11.4. Balance refrigerant of the 2-way, 3-way valves
11.5. Evacuation
11.6. Gas charging
12 Servicing Information
12.1. Distinction of Lead Free (PbF) Printed Circuit Board
12.2. Indoor Electronic Controller Removal Procedures
12.3. Indoor Fan Motor and Cross Flow Fan Removal
Procedures
12.4. Auto OFF/ON Button
12.5. Remote Control Reset

1 Features

High Efficiency
Compact Design
Wider range of horizontal discharge air.
Air Filter with function to reduce dust and smoke.
13 Troubleshooting Guide 57
40
45
46
47
48
49
50
51
52
52
52
54
55
56
13.1. Refrigeration cycle system
13.2. Relationship between the condition of the air conditioner
and pressure and electric current
13.3. Diagnosis methods of a malfunction of a compressor
14 Technical Data
14.1. Thermostat characteristics
14.2. Operation characteristics
15 Exploded View (Indoor Unit)
16 Replacement Parts List (Indoor Unit)
17 Exploded View (Outdoor Unit)
18 Replacement Parts List (Outdoor Unit)
19 Electronic Circuit Diagram
19.1. Indoor Unit
19.2. Remote Control
19.3. Print Pattern Indoor Unit Printed Circuit Board
Quality Improvement
Random auto restart after power failure for safety restart
operation.
Gas leakage protection.
Prevent Compressor reverse cycle.
Inner protector to protect Compressor.
Noise prevention during soft dry operation.
Blue Coated Condenser for high resistance to corrosion.
57
58
58
59
59
60
64
65
66
67
68
68
74
75
Automatic air swing and manual adjusted by Remote
Control for vertical airflow.
Long installation piping.
CS/CU-C9DKU, long piping up to 33ft.
CS/CU-C12DKU, long piping up to 49ft.
Operation Improvement
Quiet mode to provide quiet operation.
Powerful mode to reach the desired room temperature
quickly.
24-hour timer setting.
Serviceability Improvement
Removable and washable Front Panel.
2

2 Functions

CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
ı
3
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
4
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
5
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU

3 Product Specifications

3.1. CS-C9DKU CU-C9DKU

Unit Indoor unit Outdoor unit
Power Source (Phase, Voltage, Cycle) ø, V, Hz Single, 115, 60 Cooling Capacity kW (BTU/h) 2.58 (8,800) Moisture Removal l/h (Pint/h) 1.0 (2.1)
Airflow Method OUTLET
INTAKE
Air Volume Lo m3/min (cfm) 4.7 (164) - 4.7 (164)
Me m3/min (cfm) 5.7 (202) - 5.7 (202) — Hi m3/min (cfm) 7.2 (250) - 7.2 (250) 33.8 (1,190 ) SHi m3/min (cfm) 7.8 (274) - 7.8 (274)
Noise Level dB (A) High 36 - 36, Low 26 - 26 High 49
Power level dB High 49 - 39 High 62
Electrical Data Input Power W 790
Running Current A 7.2 EER W/W (BTU/hW) 3.27 (11.10) Starting Current A 42.0
Piping Connection Port (Flare piping)
Pipe Size (Flare piping)
Drain Hose
Power Cord Length m
Dimensions Height inch (mm) 11 - 1/32 (280) 21 - 1/4 (540)
Net Weight lb (kg) 20 (9.0) 64 (29) Compressor Description Rotary (1 cylinder)
Fan Motor Description Cross-flow Fan Propeller Fan
Heat Exchanger Description Evaporator Condenser
Refrigerant Control Device Capillary Tube Refrigeration Oil (cm3) SUNISO 4GDID or ATMOS M60
Refrigerant (R-22) g (oz) 680 (24.0)
Inner diame ter inch (mm) 20/32 (16) — Length inch (mm) 25-19/32 (650)
Number of core-wire
Width inch (mm) 31 - 15/32 (799) 30 - 23/32 (780) Depth inch (mm) 7 - 7/32 (183) 11 - 3/8 (289)
Motor Type Induction (2-poles) Rated Output W 600
Material ASG32K1 PP Resin Type Induction (4-poles) Induction (6-poles) Input W 60.61 85.8 Rated Output W 15 30 Fan Speed Low rpm 750 - 750
Medium rpm 920 - 920 — High rpm 1,160 - 1,160 845 SuperHigh rpm 1,250 - 1,250
Tube material Copper Copper Fin material Aluminium (Pre Coat) Aluminium (Blue Coat) Fin Type Slit Fin Louver Fin Row / Stage (Plate fin configu ration, forced draft)
FPI 21 16 Size (W × H × L) inch (mm) 24-1/32 ×12-13/32 × 1
inch inch
inch inch
SIDE VIEW TOP VIEW
G ; Half Union 3/8”
L ; Half Union 1/4” G ; (gas side) 3/8”
L ; (liquid side) 1/4”
2×15 1×20
(610 × 315 × 25.4)
G ; 3-way valve 3/8”
L ; 2-way valve 1/4”
G ; (gas side) 3/8”
L ; (liquid side) 1/4”
rolling piston type
33-4/32 × 20-3/8 × 28/32
(841 × 508 × 22)
or ATMOS 56
6
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
Unit Indoor unit Outdoor unit
Thermostat Electrical — Protection Device 2 Stage Overload Protector Capillary Tube Length inch (mm) 26-18/32 (675)
Flow Rate l/min 13.0 Inner Diameter inch (mm) 20/32 (1.6)
Air Filter Material
Style Capacity Control Capillary Tube Compressor Capacitor µF, VAC 35 µF, 370VAC Fan Motor Capacitor µF, VAC 5.0 µF, 230VAC 8.0 µF, 230VAC
P.P.
Honeycomb
Note:
Specifications are subjected to change without prior notice for further improvement.
7
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU

3.2. CS-C12DKU CU-C12DKU

Unit Indoor unit Outdoor unit
Power Source (Phase, Voltage, Cycle) ø, V, Hz Single, 115, 60 Cooling Capacity kW (BTU/h) 3.60 (12,30 0) Moisture Removal l/h (Pint/h) 1.6 (3.4)
Airflow Method OUTLET
INTAKE
Air Volume Lo m3/min (cfm) 5.6 (199) - 5.6 (199)
Me m3/min (cfm) 6.8 (238) - 6.8 (238) — Hi m3/min (cfm) 8.0 (280) - 8.0 (280) 31.1(1,100) SHi m3/min (cfm) 8.2 (289) - 8.2 (289)
Noise Level dB (A) High 39 - 39, Low 29 - 29 High 49
Power level dB High 52 - 42 High 62
Electrical Data Input Power kW 1.16
Running Current A 10.3 EER W/W (BTU/hW) 3.10 (10.60) Starting Current A 57.0
Piping Connection Port (Flare piping)
Pipe Size (Flare piping)
Drain Hose
Power Cord Length m
Dimensions Height inch (mm) 11 - 1/32 (280) 21 - 1/4 (540)
Net Weight lb (kg) 20 (9.0) 73 (33) Compressor Description Rotary (1 cylinder) rolling piston
Fan Motor Description Cross-flow Fan Propeller Fan
Heat Exchanger Description Evaporator Condenser
Refrigerant Control Device Capillary Tube Refrigeration Oil (cm3) ATMOS M60 or SUNISO 4GDID
Refrigerant (R-22) g (oz) 760 (26.8) Thermostat Electrical — Protection Device 2 Stage Overload Protector
Inner diame ter inch (mm) 20 / 32 (16) — Length inch (mm) 25-19/32 (650)
Number of core-wire
Width inch (mm) 31 - 15/32 (799) 30 - 23/32 (780) Depth inch (mm) 7 - 7/32 (183) 11 - 3/8 (289)
Motor Type Induction (2-poles) Rated Output W 850
Material ASG32K1 PP Resin Motor Type Induction (4-poles) Induction (6-poles)
Input W 60.61 66.0 - 75.0 Rated Output W 15 31 Fan Speed Low rpm 900 - 900
Medium rpm 1,080 - 1,080
High rpm 1,280 - 1,280 820 - 820
SuperHigh rpm 1,310 - 1,310
Tube material Copper Copper Fin material Aluminium (Pre Coat) Aluminium (Blue Coat) Fin Type Slit Fin Louver Fin Row / Stage (Plate fin configuration, forced draft)
FPI 21 16 Size (W × H × L) inch (mm) 24-1/32 × 12-13/ 32 × 1
inch inch
inch inch
SIDE VIEW TOP VIEW
G ; Half Union 1/2”
L ; Half Union 1/4” G ; (gas side) 1/2”
L ; (liquid side) 1/4”
2×15 2×24
(610 × 315 × 25.4)
G ; 3-way valve 1/2”
L ; 2-way valve 1/4”
G ; (gas side) 1/2”
L ; (liquid side) 1/4”
29-10/32;28-15/32 × 19-27/32 ×
744.2;723.5 × 504 × 25.4
or ATMOS M56
type
1
8
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
Unit Indoor unit Outdoor unit
Capillary Tube Length inch (mm) 16-23/32 (425)
Flow Rate l/min 18.0 Inner Diameter inch (mm) 2/32 (1.7)
Air Filter Material
Style Capacity Control Capillary Tube Compressor Capacitor µF, VAC 50 µF, 370VAC Fan Motor Capacitor µF, VAC 5.0 µF, 230VAC 8.0 µF, 230VAC
P.P.
Honeycomb
Note:
Specifications are subjected to change without prior notice for further improvement.
9
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU

4 Dimensions

4.1. Indoor Unit & Remote Control

10

4.2. Outdoor Unit

CU-C9DKU
CU-C12DKU
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
11
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU

5 Refrigeration Cycle Diagram

CS-C9DKU CU-C9DKU
CS-C12DKU CU-C12DKU
12

6 Block Diagram

CS-C9DKU CU-C9DKU
CS-C12DKU CU-C12DKU
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
13
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU

7 Wiring Diagram

CS-C9DKU CU-C9DKU
CS-C12DKU CU-C12DKU
REMARKS
B : BLUE BR : BROWN BL : BLACK GRY : GRAY O : ORANGE P : PINK R : RED W : WHITE Y/G : YELLOW/GREEN
Power Supply Cord
Resistance of Indoor Fan Motor Windings
MODEL CS-C9DKU
CS-C12DKU
CONNECTION CWA921143
BLUE-YELLOW 82.4
YELLOW-RED 103.4
Note: Resistance at 68°F of ambient temperature.
Resistance of Outdoor Fan Motor Windings
MODEL CU-C9DKU
CONNECTION CWA951244
BLUE-YELLOW 61.2
YELLOW-RED 53.4
Note: Resistance at 78.8°F of ambient temperature.
CU-C12DKU
Resistance of Compressor Windings
MODEL CU-C9DKU CU-C12DKU
CONNECTION 2R135126A 2P19S126C-1A
C-R 0.938 0.613 C-S 2.611 2.106
Note: Resistance at 77°F/68°F of ambient temperature.
14
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU

8 Operation Details

8.1. Cooling Operation

Cooling operation can be set using remote control.
This operation is applied to cool down the room temperature reaches the setting temperature set on the remote control.
The remote control setting temperature, which takes the reading of intake air temperature sensor, can be adjusted from 60.8°F
to 86°F.
During cooling operation, the compressor will stop running and restart as shown in below figure.
8.1.1. Cooling Operation Time Diagram
15
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU

8.2. Soft Dry Operation

Soft Dry operation can be set using remote control.
Soft Dry operation is applied to dehumidify and to perform a gentle cooling to the room.
This operation starts when the intake air temperature sensor reaches the setting temperature on the remote control.
When operation begins, Soft Dry will be switched “ON” for a maximum 10 minutes, then Soft Dry operation will be turned “OFF”
for a minimum 6 minutes. After that, the Soft Dry operation will be “ON” and “OFF” based on the setting temperature as shown in below figure.
However after 3 minutes of compressor off, during Soft Dry “OFF” (within 6 minutes Soft Dry restart control), the indoor unit will
start to operate at normal Cooling mode if the intake temperature is higher than Cooling “ON” point.
8.2.1. Soft Dry Operation Time Diagram
16
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU

8.3. Automatic Operation

Automatic operation can be set using remote control.
This operation starts to operate with indoor fan at SLo speed for 20 seconds to judge the intake air temperature.
After judged the temperature, the operation mode is determined by referring to the below standard.
Then, the unit start to operate at determined operation mode, until it is switched off using remote control, with the setting
temperature as shown in below table.
The setting temperature for all the operations can be changed one level up or one level down from the standard temperature
as shown in below table by pressing on the temperature up or temperature down button at remote control.
The operation mode judging temperature and standard setting temperature can be increased by 3.6°F permanently, by open
the circuit of JX1 at indoor electronic controller.
17
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU

8.4. Operation Control

8.4.1. Restart Control (Time Delay Safety Control)
When the thermo-off temperature (temperature which compressor stops to operate) is reached during:-
Cooling/Heating operation - the compressor stops for 3 minutes (minimum) before resume operation.
Soft Dry operation - the compressor stops for 6 minutes (minimum) before resume operation.
If the operation is stopped by the remote control, the compressor will not turn on within 3 minutes from the moment operation
stop, although the unit is turn on again within the period.
This phenomenon is to balance the pressure inside the refrigerant cycle.
8.4.2. 7 Minutes Time Save Control
The compressor will start automatically if it has stopped for 7 minutes and the intake air temperature falls between the
compressor ON temperature (A) and compressor OFF temperature (B) during the period.
This phenomenon is to reduce the built up humidity inside a room.
8.4.3. 60 Seconds Forced Operation
Once the air conditioner is turned on, the compressor will not stop within 60 seconds in a normal operation although the intake
air temperature has reached the thermo-off temperature. However, force stop by pressing the OFF/ON operation button at the remote control is permitted.
The reason for the compressor to force operate at minimum 60 seconds is to allow the refrigerant oil run in a full cycle and
return back to the outdoor unit.
8.4.4. Starting Current Control
When the compressor, outdoor fan motor and indoor fan motor are simultaneously started, the indoor fan motor will start to
operate at 1.6 second later.
The reason of the difference is to reduce the starting current flow.
18
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
8.4.5. Anti-Freezing Control
If the temperature of the indoor heat exchanger falls below 35.6°F continuously for 4 minutes or more, the compressor turns off.
The fan speed setting remains the same.
This phenomenon is to protect the indoor heat exchanger from freezing and to prevent higher volume of refrigerant in liquid form
returning to the compressor.
Compressor will restart again when the indoor heat exchanger temperature rises to 50°F (Recovery).
Restart control (Time Delay Safety Control) will be applied in this Control if the recovery time is too short.
8.4.6. Compressor Reverse Rotation Protection Control
If the compressor is operating continuously for 5 minutes or longer and the temperature difference between intake air and
indoor heat exchanger is 4.5°F or less for continuous 2 minutes, compressor will stop and restart automatically.
Time Delay Safety Control is activated before the compressor restart.
s T = Intake air temperature - Indoor heat exchanger temperature
This is to prevent compressor from rotate reversely when there is an instantaneous power failure.
8.4.7. Anti-Dew Formation Control
Purpose is to prevent dew formation on indoor unit discharge area.
When room temperature is constant (±1.8°F) the following condition occur for 30 minutes continuously, anti-dew formation will
activate:
- Indoor intake temperature is more than 75.2°F and less than 86°F.
- Remote Control setting temperature is less than 77°F
- Compressor is on.
- Cooling Operation Mode.
- Indoor fan motor operate at Low fan speed or QLo.
19
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
Anti-Dew Formation is control by:-
Increasing Air Flow Volume
1. Lo fan speed.
Lo fan speed is changed to Lo+ after 30 min to prevent dew formation.
2. QLo fan speed.
Dew formation may occur at QLo cool, therefore QLo cool is operated only 1hr 30min (1 hr QLo, 30 min QLo + 80 rpm). After that, it operates at QLo + 160 rpm (However Quiet LED remains on).
Narrowing
1. Vertical Airflow Direction
During Anti-Dew condensation prevention, Airflow Direction Auto-control angle from 0° - 32° to 20° - 30° under cooling and Soft Dry operation mode.
20
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
During Anti-Dew condensation prevention, Airflow Direction Manual Control angle change from 10°, 15°, 20°, 26°, 32° to 22°, 24°, 26°, 28°, 30°.

8.5. Indoor Fan Speed Control

Indoor Fan Speed can be set using remote control.
8.5.1. Fan Speed Rotation Chart
Speed Fan Speed (rpm)
CS-C9DKU CS-C12DKU
SHi 1250 1310
Hi 1160 1280
Me 920 1080 HLo 840 960 CLo 750 900
Lo- 750 850 SLo 710 820
SS Lo - ­QSHi - -
QHi 1060 1180
QMe 820 980
QH Lo - -
QLo 650 800
21
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
8.5.2. Automatic Fan Speed Control
When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the table.
Fan speed rotates in the range of Hi and Me.
Deodorizing Control will be activated.
Auto Fan Speed during cooling operation:
1. Indoor fan will rotate alternately between off and on as shown in below diagram.
2. At the beginning of each compressor start operation, indoor fan will increase fan speed gradually for deodorizing purpose.
3. For the first time the compressor operate, indoor fan will be switched to Hi fan speed from Lo- after 70 seconds from the start of compressor. This cause the room temperature to achieve the setting temperature quickly.
4. During compressor stop, indoor fan will operate at Lo for the beginning 20 seconds to prevent higher volume of refrigerant in liquid form returning to the compressor.
5. After the compressor at turn off condition for 3 minutes, indoor fan will start to operate at Lo- to circulate the air in the room. This is to obtain the actual reading of the intake air temperature.
6. For the resume of compressor operation, indoor fan will operate at Me fan speed to provide comfort and lesser noise environment, after 70 seconds from the restart of compressor.
22
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU
Auto Fan Speed during Soft Dry operation:
1. Indoor fan will rotate alternately between off and Lo-.
2. At the beginning of each compressor start operation, indoor fan will increase fan speed gradually for deodorizing purpose.
3. When compressor at turn off condition for 6 minutes, indoor fan will start fan speed at Lo- to circulate the air in the room. This is to obtain the actual reading of intake air temperature.
8.5.3. Manual Fan Speed Control
Manual fan speed adjustment can be carried out by using the Fan Speed selection button at the remote control.
There are 3 types of fan speed settings: Lo, Me, Hi.

8.6. Outdoor Fan Speed Control

There is only one speed for outdoor fan motor.
When the air conditioner is turned on, the compressor and the outdoor fan will operate simultaneously.
Likewise, both compressor and outdoor fan will stop at the same time if the unit is turned off.

8.7. Vertical Airflow Direction Control

8.7.1. Auto Control
When the vertical airflow direction is set to Auto using the
remote control, the louver swings up and down as shown in the diagram.
When stop operation using the remote control, the
discharge vent is reset, and stop at the closing position.
During Cooling operation or Soft Dry operation, indoor fan
motor may stop to rotate at certain periods. At that condition, the louver will stop swinging and rest at the upper limit.
8.7.2. Manual Control
When the vertical airflow direction is set to Manual using the
remote control, the automatic airflow is released and the airflow direction louver move up and down in the range shown in the diagram.
The louver can be adjusted by pressing the button to the
desired louver position.
When stop operation using the remote control, the
discharge vent is reset, and stop at the closing position.
23
CS-C9DKU CU-C9D KU / CS-C12DKU CU-C12DKU

8.8. Horizontal Airflow Direction Control

The horizontal airflow direction louvers can be adjusted manually by hand.

8.9. Powerful Operation

The Powerful operation is to achieve the setting temperature quickly.
When Powerful operation is set, the setting temperature will be automatically decreased 5.4°F internally against the present
setting temperature (Lower temperature limit: 60.8°F).
This operation automatically will be running under SHi Fan Speed (Cooling), Lo- Fan Speed (Soft Dry).
Vertical Airflow Direction:-
- In “Manual” setting, the vane will automatically shift down 10° lower than previous.
- In “Auto” setting, the vane will automatically swing up and down. However the lower limit will be shifted 10° downward.
Powerful Mode will operate for 15 minutes only and operation will shift back to previous setting mode.
Powerful operation stops when:-
- Powerful mode button is pressed again.
- Stopped by OFF/ON operation button.
- Timer OFF activates.
- Quiet mode button is pressed.
- Operation mode button is changed.
- Economy mode button is pressed.
24
Loading...
+ 53 hidden pages