TROUBLESHOOTING
7
INFORMATION
26~27
QUICK GUIDE
BACK COVER
NOTE
The illustrations in this manual are for
explanation purposes only and may
differ from the actual unit. It is subjected
to change without notice for future
improvement.
OPERATION CONDITION
Use this air conditioner under the following
temperature range
Temperature (°C)
COOLING
Max.3223
Min.1611
Indoor
*DBT *WBT
These symbols denote an actions that
is COMPULSORY.
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not
play with the appliance.
Please consult authorized dealer or specialist to repair,
install, remove and reinstall the unit. Improper installation
and handling will cause leakage, electric shock or fi re.
Do not install the unit in a potentially explosive or fl ammable
atmosphere. Failure to do so could result in fi re.
Do not insert your fi ngers or other objects into the
air conditioner indoor or outdoor unit, rotating parts
may cause injury.
Do not touch the outdoor unit during lightning, it may cause
electric shock.
REMOTE CONTROL
Do not allow infants and small children to play with the
remote control to prevent them from accidentally swallowing
the batteries.
Temperature (°C)
COOLING
* DBT: Dry bulb temperature
* WBT: Wet bulb temperature
2
Outdoor
*DBT *WBT
Max.4326
Min.1611
CAUTION
WARNING
Air Inlet
Air Outlet
Air Outlet
Air Inlet
Air Inlet
WARNING
POWER SUPPLY
Do not use modifi ed cord,
joint cord, extension cord or
unspecifi ed cord to prevent
overheating and fi re.
Do not share the same power outlet with other
equipment to prevent overheating and fi re.
Do not operate with wet hands to prevent electric
shock.
If the supply cord is damage, it must be replaced
by the manufacturer, its service agent or similarly
qualifi ed persons in order to avoid a hazard.
It is strongly recommended to be installed
with Earth Leakage Circuit Breaker (ELCB)
or Residual Current Device (RCD) to prevent
electric shock or fi re.
This equipment must be earthed to prevent
electrical shock or fi re.
In case of emergency or abnormal conditions
(burnt smell, etc), turn off the power supply, and
please consult authorized dealer.
Prevent electric shock by switching off the power
supply when:
- Before cleaning or servicing.
- Extended non-use.
- Abnormally strong lightning activity.
CAUTION
INDOOR UNIT AND OUTDOOR UNIT
Do not wash the indoor unit with water,
benzene, thinner or scouring powder.
Do not use for other purpose such as
preservation of food.
Do not use any combustible equipment in front
of the airfl ow outlet to avoid propagation fi re.
Do not expose yourself directly to cold air for a
long period.
Do not sit or step on the unit, you
may fall down accidentally.
Do not touch the sharp aluminium fi n,
sharp parts may cause injury.
Do not switch ON the indoor unit when waxing
the fl oor. After waxing, aerate the room properly
before operating the unit.
Do not install the unit in oily and smoky areas.
Ensure drainage pipe is connected properly.
Otherwise, leakage may occur.
Aerate the room regularly.
After long period of use, make sure the
installation rack is not deteriorate to prevent the
unit from falling down.
REMOTE CONTROL
Do not use rechargeable (Ni-Cd) batteries.
It may damage the remote control.
ENGLISH
Remove the batteries if the unit is not going to
be used for a long period of time.
New batteries of the same type must be
inserted following the polarity stated to prevent
malfunction of the remote control.
Indoor
Remote
Unit
Air Inlet
Control
Air Outlet
Outdoor
Unit
Air Inlet
Air Inlet
Power
Supply
Air Outlet
3
REMOTE CONTROL
FAN SPEED
AIR SWING
ECO
PAT
ROL
PATROL/
QUIET/
POWERF
UL
MODE
TEM
P
OFF/ON
TIMER
SET
CAN
CEL
ON
OFF
1
2
3
SET
CLOCK
RESET
OFF
TIMER
ON
TIMER
AUTO
COOL
DRY
FAN
SPEED
AIR
SWING
C9KKV, C9KKV-6, C12KKV, C12KKV-6
Maximum
distances: 8m
INDICATOR
POWER
TIMER
QUIET
POWERFUL
ECO PATROL
(Red/Orange/Blue)
(Green)
(Orange)
(Orange)
(Orange)
(Blue)
(Green)
Standard setting
PATROL SENSOR
Press the remote control’s button
1
TO TURN ON OR OFF THE UNIT
• Please be aware of the OFF indication on the remote
control display to prevent the unit from starting/stopping
improperly.
2
TO SET TEMPERATURE
• For cool and dry modes, the range of temperature for
selection is 16˚C ~ 30˚C.
• Operating the unit within the recommended temperature
could induce energy saving.
COOL mode : 26˚C ~ 28˚C.
DRY mode : 1˚C ~ 2˚C lower than room temperature.
3
TO SELECT OPERATION MODE
AUTO mode - For your convenience
• Unit selects the operation mode according to the room
temperature.
• Once auto mode is selected, the unit will operate at the
standard setting temperature.
Room
temperature
23˚C & aboveCool25˚C
Below 23˚CDry22˚C
• Press
standard setting temperature.
COOL mode - To enjoy cool air
• Use curtains to screen off sunlight and outdoor heat to
reduce power consumption during cool mode.
DRY mode - To dehumidify the environment
• Unit operates at low fan speed to give a gentle cooling
operation.
4
FAN SPEED
• For AUTO, the indoor fan speed is automatically adjusted
4
for “HI” to +2˚C or for “LO” to -2˚C to the
TO SELECT FAN SPEED (3 OPTIONS)
according to the operation mode.
Operation mode
temperature
TO ADJUST VERTICAL AIRFLOW DIRECTION
5
(5 OPTIONS)
AIR SWING
• Keeps the room ventilated.
• In COOL/DRY mode, if AUTO is set, the louver swing
up/down automatically.
6
TO ADJUST AIRFLOW DIRECTION (5 OPTIONS)
(PAGE 5)
AIR SWING
• Keeps the room ventilated.
• In COOL/DRY mode, if AUTO is set, the louver swing
left/right and up/down automatically.
TO MONITOR HUMAN PRESENCE
7
& ACTIVITY FOR ENERGY SAVING
ECO
PATROL
Heat Source & Movement
ECO 1ECO 2ECO OFF
Low
High
None
Set Temperature
-1°C
Set Fan Speed
+1 tap
≤ Medium
Fan
• — ECO 1 - To optimize comfort and energy saving.
• --- ECO 2 - To maximize energy saving.
Remote Control display
7
3
11
12
13
15
C9KKV, C9KKV-6, C12KKV, C12KKV-6
+3°C
+2°C
1
8
4
2
5
14
FAN SPEED
POWERFUL
ECO
PAT
ROL
PAT
ROL/
MODE
QUI
ET
TEMP
OFF/ON
TIMER
SET
CAN
CEL
ON
OFF
1
2
3
AIR
SWI
NG
SET
CLOCK
C18KKV, C18KKV-6, C24KKV, C24KKV-6,
C28KKV, C28KKV-6
NOTES
QUIET
POWERFUL
P
Q
P
TO SET THE TIMER
S
O
8
Q
TO ENJOY CLEAN AND FRESH AIR
PATROL/
PATROL
NORMAL
PATROL - To monitor air quality
• Detects air quality; e-ion operation
activates when air quality is at dirty
level.
• Regardless of air quality, to
maintain air freshness e-ion
activates automatically (PATROL
Indicator Air Quality
BlueClean
OrangeModerate
RedDirty
SENSOR indicator turns red) when:
- 2 minutes after the unit is on, or
- exceeds 4 hours at clean level.
• Can be activated even when the unit is turned off.
• Patrol starts automatically with the unit switched on with
OFF/ON
.
- To freshen and purify the air
• Generates negative ions to produce fresh air effect and
attract dust which will then be captured at the positively
charged e-ion fi lters.
• Can be activated even when the unit is turned off. In this
condition, fan speed and air swing can not be adjusted.
9
TO ENJOY QUIET OPERATION
• This operation reduces airfl ow noise.
TO REACH TEMPERATURE
10
QUICKLY
• This operation will stop automatically after 15 minutes.
Press and hold for 5 seconds to dim or restore the
12
unit’s indicator brightness.
Press and hold for approximately 10 seconds to
13
show temperature setting in °C or °F.
14
Press to restore the remote control’s default setting.
15
Not used in normal operations.
NOTES
PATROL/
OWERFUL
,
,
,
QUIET/
PATROL
,
ECO
• Can be activated in all modes and can be cancelled
by pressing the respective button again.
ECO
UIET
POWERFUL
,
QUIET/
OWERFUL
,
PATROL
,
• Cannot be selected at the same time.
ENGLISH
11
TO SWITCH BETWEEN QUIET & POWERFUL
UIET/
POWERFUL
QUIETPOWERFULNORMAL
• QUIET & POWERFUL operations function similarly as
10
9
described for
and
respectively.
6
9
C18KKV, C18KKV-6, C24KKV, C24KKV-6,
C28KKV, C28KKV-6
TO SET THE TIMER
• To turn ON or OFF the unit at a preset time.
ON
1
OFF
Select ON or
OFF timer
2
Set the timeConfi rm
• To cancel ON or OFF timer, press
press
CANCEL
.
• When ON Timer is set, the unit may start earlier (up
10
to 15 minutes) before the actual set time in order to
achieve the desired temperature on time.
• Timer operation is based on the clock set in the
remote control and repeats daily once set. For clock
setting, please refer to Remote Control Preparation at
back cover.
• If timer is cancelled manually or due to power failure,
you can restore the previous setting (once power is
resumed) by pressing
SET
.
ET
N
OFF
or
then
5
INDOOR UNIT
CLEANING INSTRUCTIONS
HINT
• Switch off the power supply before cleaning.
CAUTION
CLEANING INSTRUCTIONS
• Do not use benzene, thinner or scouring powder.
• Use only soap ( pH7) or neutral household detergent.
• Do not use water hotter than 40°C.
4
2
3
5
6
7
• Do not touch the aluminium fi n, sharp parts may cause injury.
HINT
• To ensure optimal performance of the unit, cleaning
maintenance has to be carried out at regular intervals.
Please consult authorized dealer.
1
8
9
10
11
9, 10, 11
5
e-ion AIR PURIFYING
SYSTEM
• Do not touch during operation
ECO PATROL SENSOR
• Do not hit or violently press the
sensor or poke it with a sharp
object. This can lead to damage
and malfunction.
• Do not place large objects near
the sensor and keep heating units
or humidifi ers off the sensor’s
detection area. This may lead to
sensor malfunction.
1
INDOOR UNIT
• Wipe the unit gently with a soft, dry cloth.
2
FRONT PANEL
Remove Front Panel
• Raise and pull to remove the front panel.
• Wash gently and dry.
Close Front Panel
• Press down both ends of the front panel to close it
securely.
• Use when remote control is misplaced or a malfunction
occurs.
Press once.Auto
Press and hold until 1 beep is
heard, then release.
Press the button to turn off.
9
10
• Clean the fi lters regularly.
• Wash/rinse the fi lters gently with water to avoid damage
to the fi lter surface.
• Dry the fi lters thoroughly under the shade, away from
fi re or direct sunlight.
• Replace any damaged fi lters.
11
Clean with dry cotton bud.
• Active e-ion generator cleaning is
recommended every 6 months.
ActionMode
Cooling
e-ion CHARGING WIRE
e-ion FILTERS
ACTIVE e-ion GENERATOR
TROUBLESHOOTING
The following symptoms do not indicate malfunction.
SYMPTOM
CAUSE
Check the following before calling for servicing.
SYMPTOM
CHECK
Notes on “ECO PATROL SENSOR”
The following symptoms do not indicate malfunction.
SYMPTOM
Mist emerges from indoor unit.► • Condensation effect due to cooling process.
Water fl owing sound during operation.► • Refrigerant fl ow inside the unit.
The room has a peculiar odour.► • This may be due to damp smell emitted by the wall,
Indoor fan stops occasionally during automatic fan speed
setting.
Operation is delayed a few minutes after restart.► • The delay is a protection to the unit’s compressor.
Outdoor unit emits water/steam.► • Condensation or evaporation occurs on pipes.
Timer indicator is always on.► • The timer setting repeats daily once set.
Cracking sound during operation. ► • Changes of temperature cause the expansion/
Inconsistent airfl ow during PATROL operation.► • Fan speed is adjusted automatically during patrol
Check the following before calling for servicing.
SYMPTOM
Cooling operation is not working effi ciently.► • Set the temperature correctly.
Noisy during operation.► • Check if the unit has been installed at an incline.
Remote control does not work.
(Display is dim or transmission signal is weak.)
The unit does not work.► • Check if the circuit breaker is tripped.
The unit does not receive the signal from the remote
control.
Patrol sensor or e-ion indicator on the indoor unit is
blinking.
carpet, furniture or clothing.
► • This helps to remove the surrounding odours.
contraction of the unit.
operation.
Select QUIET operation to maintain the airfl ow
consistency.
• Close all doors and windows.
• Clean or replace the fi lters.
• Clear any obstruction at the air inlet and air outlet vents.
• Close the front panel properly.
► • Insert the batteries correctly.
• Replace weak batteries.
• Check if timers have been set.
► • Make sure the receiver not obstructed.
• Certain fl uorescent lights may interfere with signal
transmitter. Please consult authorized dealer.
► • Stop Patrol or e-ion operation then restart. If the patrol
sensor or e-ion indicator still blinking, please consult
authorized dealer.
CAUSE
CHECK
ENGLISH
Notes on “ECO PATROL SENSOR”
• Sensor may not detect moving objects further than 7m away or beyond detection angle.
• Sensor sensitivity is infl uenced by indoor unit location, movement speed, temperature range, etc.
• The sensor may mistakenly detects pets, sunlight, certain lighting, fl uttering curtains and light refl ection as human being.
7
AVISO
CUIDADO
AVISO
UNIDADE INTERIOR E UNIDADE EXTERIOR
Obrigado por adquirir o Ar
ÍNDICE
NOTA
CONDIÇÃO DE
FUNCIONAMENTO
Condicionado da Panasonic
ÍNDICE
PRECAUÇÕES
DE SEGURANÇA
CONTROLE REMOTO
10~11
8~9
PRECAUÇÕES DE SEGURANÇA
Para evitar danos pessoais, danos a outros, ou danos na propriedade, por
favor cumpra o seguinte.
A utilização incorreta devido ao incumprimento das instruções pode resultar
em ferimentos ou danos cuja gravidade é classifi cada da seguinte forma:
AVISO
CUIDADO
As instruções a seguir são classifi cadas com os seguintes símbolos:
Este símbolo indica perigo de morte ou
ferimento grave.
Este símbolo indica perigo de ferimento ou
danos de bens.
UNIDADE INTERIOR
RESOLUÇÃO
DE PROBLEMAS
INFORMAÇÃO
26~27
GUIA RÁPIDO
TAMPA TRASEIRA
NOTA
As ilustrações deste manual têm
apenas um caráter explicativo e podem
diferir da unidade real. Estão sujeitas a
alteração sem aviso prévio para fi ns de
melhoramento futuro.
CONDIÇÃO DE
FUNCIONAMENTO
Utilize este ar condicionado com o
seguinte intervalo de temperatura
Temperatura (°C)
REFRIGERAÇÃO
Máx.3223
Mín.1611
Interior
*DBT *WBT
12
13
Este símbolo indica uma ação
PROIBIDA.
Este símbolo denota uma ação que é
UNIDADE INTERIOR E UNIDADE EXTERIOR
COMPULSÓRIA.
AVISO
Este dispositivo não se destina ao uso por pessoas
(incluindo crianças) com reduzidas capacidades
físicas, sensoriais ou mentais, ou falta de experiência e
conhecimento, exceto se tiverem supervisão ou instrução
relacionadas com o uso do dispositivo por uma pessoa
responsável pela sua segurança. As crianças devem ser
supervisionadas para assegurar que não brincam com o
dispositivo.
Por favor consulte o representante autorizado ou
especialista para reparar, instalar, remover e reinstalar
a unidade. A instalação inadequada e manutenção pode
provocar fuga, choque elétrico ou incêndio.
Não instale a unidade (em um/num) ambiente
potencialmente explosivo ou infl amável. Se não fi zer isso,
pode provocar incêndio por acidente.
Não coloque os seus dedos ou outros objetos na
unidade de ar condicionado interior ou exterior, as
partes rotativas podem provocar ferimentos.
Não toque na unidade exterior em caso de relâmpagos,
pode provocar choque elétrico.
CONTROLE REMOTO
Não deixe as crianças brincar com o controle remoto para
impedir que engulam acidentalmente as pilhas.
Temperatura (°C)
REFRIGERAÇÃO
* DBT: Temperatura de bolbo Seco
* WBT: Temperatura de bolbo Úmido
8
Exterior
*DBT *WBT
Máx.4326
Mín.1611
CUIDADO
UNIDADE INTERIOR E UNIDADE EXTERIOR
AVISO
Entrada de ar
Saída de ar
Entrada de ar
Entrada de ar
Saída de ar
AVISO
FONTE DE ALIMENTAÇÃO
Não utilize um cabo
modifi cado, com união,
com extensão ou não
especifi cado para evitar o
sobreaquecimento e incêndio.
Não partilhe a mesma saída de energia com
outro equipamento para evitar sobreaquecimento
e incêndio.
Não utilize com as mãos molhadas para evitar
choque elétrico.
Se o cabo de alimentação estiver danifi cado,
terá de ser substituído pelo fabricante, agente
de assistência ou técnico qualifi cado para evitar
situações de perigo.
É fortemente recomendada a instalação do
Disjuntor com fuga à terra (ELCB) ou um
Dispositivo de Corrente Residual (RCD) para
evitar choque elétrico ou incêndio.
Este equipamento deve ter ligação terra para
evitar choque elétrico ou incêndio.
Numa situação de emergência ou condições
anómalas (cheiro a queimado, etc.), desligue a
alimentação e consulte o revendedor autorizado.
Evitar choque elétrico ao desligar a fonte de
alimentação quando:
- Antes da limpeza ou manutenção.
- Não utilização prolongada.
- Forte atividade de relâmpagos fora
(palavra junta) a está separado do normal.
CUIDADO
UNIDADE INTERIOR E UNIDADE EXTERIOR
Não lave a unidade interior com água, benzina,
diluente ou pó áspero.
Não utilize a unidade para outros fi ns, como,
por exemplo, a conservação de alimentos.
Não utilize nenhum equipamento de combustão
em frente à saída de ar para evitar a
propagação de incêndio.
Não se exponha diretamente ao ar frio durante
um período de tempo prolongado.
Não se sente na unidade ou
utilize-a como um degrau, pode cair
acidentalmente.
Não toque na rebarba de alumínio
afi ada, as peças afi adas podem
provocar lesões.
Não ligue (ON) a unidade interior quando
encera o chão. Após encerar, areje a divisão
adequadamente antes de colocar a unidade em
funcionamento.
Não instalar a unidade em áreas com óleos e
fumos.
Certifi que-se que o tubo de drenagem está ligado
adequadamente. De contrário, pode ocorrer fuga.
Areje regularmente a sala.
Após longo período de uso, certifi que-se que
a armação da instalação não está deteriorada
para evitar que a unidade caia.
CONTROLE REMOTO
Não utilize pilhas recarregáveis (Ni-Cd).
Pode danifi car o controle remoto.
PORTUGUÊS
Remova as pilhas da unidade se não a pretender
utilizar durante um período de tempo prolongado.
Introduza pilhas novas do mesmo tipo seguindo
as indicações de polaridade indicadas para
evitar a avaria do controle remoto.
Unidade
Controle
Interior
Entrada de ar
Remoto
Fonte de
Saída de ar
Unidade
Exterior
Entrada de ar
alimentação
Entrada de ar
Saída de ar
9
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.