Thank you very much for using SUNX products. Please read this Instruction Manual carefully and thoroughly for the correct and optimum use of this product. Kindly keep this manual in a convenient place for quick reference.
1
CAUTIONS
Make sure that the power is off while wir­ing to the amplifier.
When using shield wires, twist the wire to a diameter of Ǿ1.2mm or less before in­serting into the connector.
Take care not to damage the wires when stripping the wire insulation.
Do not insert 2 or more wires into a wire inlet. If connecting 2 or more wires, it causes a failure.
Make sure not to short-circuit due to splaying of wires or shielded wire etc.
Do not pull the connector or cable with excessive force. This may cause damage or a wire-break of the connector.
Do not use the connector in a state where the lock-lever has been broken. If the lock-lever has been broken, the connec­tor may come out or cause malfunction.
Make sure that stress by forcible bending or pulling is not applied directly to the wire inlet of the connector.
Do not pull the connector by using a tool, such as pliers, etc.
When wiring, hold the connector tightly. Furthermore, do not inser t the wire forci­bly. This may cause an injury.
The connector does not have a water­proof construction.
2
SPECIFICATIONS
Model No.
Item
Applicable wire
Rated current
Rated voltage DC32V Contact resist-
ance (Note 1) Voltage withstand-
ability Insulation resist-
ance
Insulation resist­ance
Insertion / withdraw-
No. of times
al Ambient temper-
ature (Note 2)
Notes: 1)
The contact resistance of the connector part.
:2)
However, this is restricted by the allowable ambient temperature range of the cable.
3
WIRE CONNECTION
0.08 to 0.5mm2(AWG 28 to 20) However, the diameter of the wire sheath should be Ǿ1.5mm or less.
3A/pole (when 0.5mm2wire is used) 2A/pole (when 0.3mm 1A/pole (when 0.2mm
0.5A/pole (when 0.1mm
30mǡ or less (20mV DC or less, at 100mA or less)
1,000V AC for 1 minute (Leak current: 1mA or less)
1,000Mǡ,or more, with 500V DC
1,000Mǡ,or more, with 500V DC
CN-EP1
2 2
50 times
-30 to +75
wire is used) wire is used)
2
wire is used)
Wire connecting procedure
Process the core length to 7 to 8 mm in accord­ance with 'STRIP GAUGE' indicated on the side of this unit, and twist the core several times. When using shielded wires, twist the wire to a diameter of Ǿ1.2 mm or less.
STRIP GAUGE
Connector (CN-EP1)
Use a flathead screwdriver (Blade width:
Core length: 7 to 8 mm
Wire
2 mm or less) to push the operating lever (white) located at the operating area until it is locked.
Flathead screwdriver (Blade width: 2 mm or less)
Operating area
Insert the wire to the bottom of the wire inlet. Check that the shield part of the wire is properly inserted into the wire inlet as well as that the core end has passed through the wire connection area as shown in the figure below.
Shield part
Wire connection area
Place the head of a flathead screw-driver
of wire
Wire inlet
underneath the operating lever (white) through the releasing slot, and lift the screwdriver head. If you hear a snap, the operating lever (white) is returned and the wire is fixed.
Releasing slot
Operating lever (white)
Slightly pull the wire to ensure that the wire is not loose. When using shielded wires, also check that they are not in contact with each other.
Shielded wires
Releasing procedure
Use a flathead screwdriver (Blade width: 2mm or less) to push the operating lever (white) located at the wire inlet and re­move the wire.