The lightning flash with arrowhead symbol, within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated dangerous voltage within
the product s enclosure that may be of sufficient
magnitude to constitute a risk of electric shock to
persons.
The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in
the literature accompanying the appliance.
THIS APPARATUS MUST BE GROUNDED
To ensure safe operation the three-pin plug must be
inserted only into a standard three-pin power outlet
which is effectively grounded through normal household wiring.
Extension cords used with the equipment must be
three-core and be correctly wired to provide connection to the ground. Incorrectly wired extension cords
can be extremely hazardous.
The fact that the equipment operates satisfactorily
does not imply that it is grounded, and the installation is not necessarily safe. For your safety, if in any
doubt about the effective grounding of the equipment
or power outlet, please consult a qualified electrician.
CAUTION:
Do not install or place this unit in a bookcase,
built- in cabinet or in another confined space in
order to keep well ventilation condition. Ensure
that curtains and any other materials do not obstruct the ventilation condition to prevent risk of
electric shock or fire hazard due to overheating.
CAUTION:
TO REDUCE THE RISK OF FIRE OR
SHOCK HAZARD AND ANNOYING
INTERFERENCE, USE THE RECOMMENDED ACCESSORIES ONLY.
WARNING:
TO REDUCE THE RISK OF FIRE OR SHOCK
HAZARD, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
WARNING:
TO REDUCE THE RISK OF FIRE OR SHOCK
HAZARD, KEEP THIS EQUIPMENT AWAY
FROM ALL LIQUIDS-USE AND STORE ONLY
IN LOCATIONS WHICH ARE NOT EXPOSED
TO THE RISK OF DRIPPING OR SPLASHING
LIQUIDS, AND DO NOT PLACE ANY LIQUID
CONTAINERS ON TOP OF THE EQUIPMENT.
CAUTION:
TO REDUCE THE RISK OF FIRE OR
SHOCK HAZARD, REFER MOUNTING OF
THE OPTIONAL BOARD TO AUTHORIZED
SERVICE PERSONNEL.
CAUTION:
TO REDUCE THE RISK OF FIRE OR SHOCK
HAZARD, REFER CHANGE OF THE SWITCH
SETTING INSIDE THE UNIT TO AUTHORIZED SERVICE PERSONNEL.
FCC Note:
This device complies with Part 15 of the FCC Rules.
To assure continued compliance follow the attached
installation instructions and do not make any
unauthorized modifications.
This equipment has been tested and found to comply
with the limits for a Class A digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful
interference when the equipment is operated in a
commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a
residential area is likely to cause harmful interference
in which case the user will be required to correct the
interference at his own expense.
1 is the sefety information.
IMPORTANT
“Unauthorized recording of copyrighted television programs, video tapes and other materials
may infringe the right of copyright owners and
be contrary to copyright laws.”
Operating precaution
Operation near any appliance which generates
strong magnetic fields may give rise to noise in
the video and audio signals. If this should be
the case, deal with the situation by, for instance,
moving the source of the magnetic fields away
from the unit before operation.
– 2 –
Contents
General and Features ...............................................4
Controls and their functions ...................................... 6
Front panel ..............................................................6
•
Connector area .....................................................15
•
Operations using the front panel bottom controls .... 18
Operations using the front panel top controls .......... 21
Before operating this unit, check that all of its accessories are present and accounted for.
Power cord....1 pc
Options
AJ-MA75P Rack mounting adapter
•
AJ-UC1500 SD input up-converter board
•
AJ-VNC150P encoder/decoder board to support DVCPRO HD bank data
•
AJ-YAC150P SDTI interface board
•
– 3 –
General and Features
This unit is a DVCPRO HD-LP format HD digital video cassette recorder which is designed to
use 1/4-inch wide compact cassette tapes.
It is a studio-use digital VTR which can record, play back and edit HD signals (1080i/720p,
59.94 Hz), and can play back tapes recorded using the existing DVCPRO (25 Mbps/50
Mbps) format. Use of the HD-SD conversion facility of the format converter (standard feature
of this unit) enables interfacing with existing SD systems and development into HD systems.
This VTR with its high picture quality uses high-efficiency digital compression technology to
reduce by a significant margin the degree of deterioration in the sound and picture quality
which accompanies dubbing.
The unit features a compact 4U size and lightweight design to make it easier to carry around.
It can also be easily installed in a 19-inch rack.
The settings for the unit’s setup are performed interactively while viewing the display tube at
the top front of the unit or the screen menus shown on a TV monitor. Both assemble and
insert editing facilities are provided as editing functions.
Features
Compact size and light weight
This is a 4U digital VTR. Using the rack-mounting adapters (optional accessory: AJ-MA75P),
it can also be easily housed in a 19-inch rack.
Up to 92 minutes of recording
Using the DVCPROHD-LP recording system, up to 92 minutes of material can be recorded
on a 1/4" L-size cassette tape.
High picture quality
The unit’s high picture quality is achieved by 4:2:2 HD component signal recording using a
recording rate (100 Mbps) which is 4 times higher than that of the existing DVCPRO format.
1080i/59.94 Hz, 720p/59.94 Hz signal switching
By selecting the menu, each type of signal can be recorded and played back.
SDI interface
The unit comes with an HD serial digital interface as a standard accessory.
Playback compatibility with DVCPRO systems
Besides DVCPROHD-LP recordings, tapes which have been recorded using an existing
system such as DVCPROHD, DVCPRO50 or DVCPRO can be played back on this unit.
Consumer-use DV tapes (SP) can also be played back on this unit.
Digital slow motion/dial jog
Panasonic’s unique digital slow motion technology enables clear playback (of tapes recorded
using the DVCPROHD-LP system) at speeds ranging from -1× to +2×.
<Note>
Some noise may occur during slow playback (using the external controller) at speeds almost
exactly +2× or -1×.
Search speed
Search speed enables the tape to be played back with color images at a speed of up to 100
times the forward and reverse direction.
– 4 –
General and Features
Features
(continued)
Time codes
This unit comes with a built-in time code generator (TCG)/time code reader (TCR). In
addition to the internal time code, an external time code can also be recorded as the LTC on
the unit’s tape.
Multi-functional interfaces
Serial digital input and output connector
•
The unit features a HD component serial interface input/output connector to enable HD
component video signals and 8-channel digital audio signals to be interfaced using just the
one BNC connector. (SMPTE 292M, BTA S-004)
The unit comes with an HD/SD format converter as a standard accessory so that even SD
component serial signals can be output. (SMPTE 259M-C, 272M, 294M)
Analog video output connector
•
Composite signals are output during DVCPRO50- or DVCPRO-compatible playback, DV
playback, DVCAM playback and down-conversion.
AES/EBU audio input/output connectors
•
Digital audio input/output connectors for 8 channels are featured as a standard accessory.
SDTI input/output connector
•
Use of the SDTI board (optional accessory) enables interfacing with the compressed
component signals still in their original form. (SMPTE 305M, 321M)
SD signal up-conversion and recording
•
Using the input up-converter board (optional accessory), SD component serial signals
(SMPTE 259M-C) can be up-converted and recorded as HD signals.
9-pin RS-422A and RS-232C remote control connectors
•
In addition to the standard 9-pin serial remote (RS-422A) control connector, the unit is
equipped with RS-232C and 50-pin parallel remote control connectors.
The RS-422A facility enables parallel operation if a loop connection has been performed
between the unit and another VTR.
8-channel high-sound-quality digital audio
The 8-channel PCM audio allows for not only independent editing and mixing on all eight
channels. One channel is provided for the analog CUE track.
Menu-driven setup
The setup settings, which are conducted prior to operating the unit are performed while
viewing the setup menus either on the unit’s display or a TV monitor.
– 5 –
Controls and their functions
Front panel
[
`
_
^
]
1
4
ON
OFF
POWER
METER
FULL/FINE
L
MONITOR SELECT
R
LEVEL
CH 1/5 CH 2/6 CH 3/7 CH 4/8 CUE
HEADPHONES
PULL
OPEN
23
6
REC
PB
V
STATUS
78
AUDIO CH SELECT
CH
1
CH
ASMBL
VIDEO
1
2345678
MULTICUE
PREVIEW
AUTO EDIT
REVIEW
R
S
W
PROG
SAVE/
MENU
EXIT
5
CH CONDITIONENTER ESCAPE SHIFT
PULL FOR VARIABLE
\
SET UP
X
Z
4
CH 5CH
8
CH1/5 CH2/8 CH3/7 CH4/8 CUE TC
INSERT
PREROLL
Q
STATUS
123
TRIM
A
IN
SET
IN
T
Y
RESET
TC/CTL
TC SET
SHIFT ADJ
START
A
OUT
OUT
U
PROG MENU
1234
H
I
K
J
EJECT
F
9:
G
M-cassette / ADAPTER
Do not insert S-cassette without adaptor
L
TC INTTCTAPE
EXT EE
UB
STAND BY
EDITPLAY
MODE
PLAYER
SERVO
CONTROL
REMOTE
LOCAL
RECORDER
REC INHIBIT
REC
PUSH
JOGSHTL
SLOW
REVFWD
M
N
O
P
REWSTOP
@
A
>
<
MODE/SEL EXIT
FF
?
=
MENU SET DIAG
PULL
OPEN
;
D
E
C
B
abc
g h
d
ef
– 6 –
Controls and their functions
<Front Panel Top Section>
1 POWER switch
2 TV system/format displays
This shows the format during playback.
HD:This indicates the DVCPROHD-LP recording and playback modes as well as the
DVCPROHD playback mode.
50M:This indicates the DVCPRO50 playback mode.
25M:This indicates the DVCPRO, DV or DVCAM playback mode.
33
3 VTR status display area
33
The VTR’s statuses, programmable menus and setup menus appear in this display area.
<Status display>
This indicates the VTR statuses (format, field frequency, video/audio inputs, time code,
etc.) which have been defined by the user on the front sub-panel.
<Programmable menu display>
The setup menus which have been defined by the user are displayed on the front subpanel. Settings can be changed using the 5, 6, 7 and 8 buttons.
<Setup menu display>
The setup menus are displayed using the MENU d button.
44
4 Channel condition lamps
44
One of these lamps lights in accordance with the error rate status. (Green→Amber→Red)
Green: This lights when the error rates for the video and audio playback signals are both
acceptable.
Amber: This lights when the error rate for the video or audio playback signals has
deteriorated.
The playback picture will remain normal even when this lamp lights.
Red:This lights when the video or audio signals are subject to rectification or
interpolation.
55
5 Scroll buttons
55
These are used for left and right scrolling when the status is displayed in the VTR status
display area.
They are used for up and down scrolling when the programmable menu is displayed in the
VTR status display area.
66
6 ENTER button
66
Press this to enter the menu items or the settings when the programmable menu is
displayed.
7 7
7 ESCAPE button
7 7
Press this to ignore or cancel the settings when the programmable menu is displayed.
88
8 SHIFT button
88
The values of programmable menu settings can be changed at high speed by pressing the
scroll buttons while holding down the SHIFT button.
9 Cassette insertion slot
::
: EJECT button
::
When this is pressed, the tape is unloaded and several seconds later the cassette is
automatically ejected. When the counter display indicates “CTL”, the display is reset.
; AUTO OFF lamp
This lights when trouble has arisen in the deck’s operation.
– 7 –
Controls and their functions
<Front Panel Center Section>
<<
< PLAY button
<<
Playback commences when this button is pressed.
Recording commences when the button is pressed together with the REC button; manual
editing commences when it is pressed together with the EDIT button during playback.
However, manual editing will not be initiated if the servo is not locked.
Pressing only the PLAY button during manual editing will cut out the editing and establish
the playback mode.
==
= REC button
==
Recording commences when this button is pressed together with the PLAY button.
When it is pressed during playback, search*1), fast forward or rewind, EE mode images
and audio signals can be monitored for as long as it is kept depressed.
When it is pressed in the stop mode, EE mode images and sound can be monitored.
When the STOP button is pressed, the original picture and sound are restored.
>>
> STOP button
>>
When this is pressed, the tape stops traveling, and if the TAPE/EE selector switch is at
TAPE, still pictures can be monitored.
The drum continues to rotate even in the stop mode, and the tape remains in close contact
with the drum.
If the stop mode continues for more than a certain period of time, the unit automatically
switches to the standby OFF mode in order to protect the tape.
The stop mode is established immediately after a cassette has been inserted into the unit.
??
? FF button*
??
The tape is fast forwarded when this is pressed.
@@
@ REW button*
@@
The tape is rewound when this is pressed.
2)
2)
AA
A EDIT button
AA
For manual editing, press both this button and the PLAY button together during playback.
When the button is pressed in the stop mode, the input mode signals selected by the
ASMBL or INSERT button can be monitored in the EE mode.
The original picture and sound are restored when the STOP button is pressed.
When the button is pressed during playback, search*1), fast forward or rewind, the input
signals of the mode selected by the ASMBL or INSERT button can be monitored in the EE
mode for as long as the button is held down.
BB
B SERVO lamp
BB
This lights when the drum servo and capstan servo have locked.
CC
C REC INHIBIT lamp
CC
In the following situations, this lamp lights up to indicate that recording and editing cannot
be performed.
(Related setup menu items No.022, No.023, No.113, No.114, No.117 and No.118)
1. When 1 (ON) has been selected as the setup menu item No.113 (REC INH) setting
2. When the cassette has been set to the accidental erasure prevention mode
3. When “MANUAL” has been selected as the setup menu item No.022 (PB FORMAT)
setting, “HD_SP/50M/25M/50Mp/DV/DVCAM” has been selected as the No.023
(FORMAT SEL) setting, and “ON” has been selected as the No.118 (SP MODE INH)
setting, and the tape has been inserted
4. When “AUTO” has been selected as the setup menu item No.022 (PB FORMAT) setting, and
“ON” has been selected as the No.118 (SP MODE INH) setting, and a DVCPRO, DVPRO50,
DVCPRO50P, DVCPROHD (but not the LP format), DV or DVCAM tape has been inserted
5. When ON has been selected as the setup menu No.117 (M CASSTT INH) and the M
cassette tape has been inserted
1)
No guarantees are given for the audio playback sound in the search mode.
*
2)
The FF/REW speed can be selected on the setup menu No. 102 (FF. REW MAX), and it is
*
set to the same speed.
– 8 –
Controls and their functions
<Front Panel Center Section>
DD
D STAND BY button
DD
When this is pressed, the same tension as in the regular stop mode is applied to the tape,
and while the head drum continues to rotate, the button’s lamp lights to indicate that the
standby ON mode is established.
In the standby OFF mode, the half-loading mode is established.
When this button is pressed in the stop mode, the standby OFF mode is established, the
half-loading mode is established. The lamp in the button now goes off. When the unit
remains in the stop mode for longer than a predetermined period, the standby OFF mode
is automatically established in order to protect the tape.
When this button or the STOP button is pressed in the standby OFF mode, the standby
ON mode is established.
When a button other than the STOP button is pressed, the mode corresponding to the
button pressed is established.
On-screen settings are available for the transfer time to the standby OFF mode.
EE
E PLAYER/RECORDER buttons
EE
These buttons are operated when editing operations are conducted using the unit as the
recorder and a VTR equipped with an RS-422A serial interface remote control connector
(9 pins). Neither button functions when the unit is used on its own.
PLAYER button:When this button is pressed, its lamp lights, and the player connected
to the unit can be operated by remote control. The unit’s editing and
tape transport buttons now control the player’s functions.
RECORDER button: When this button is pressed, its lamp lights, and the editing and tape
transport buttons control the recorder’s (= the unit’s) functions.
Both lamps light, and the recorder functions as the master unit for Parallel Run operations
if the PLAYER or RECORDER button is pressed while “ENA” has been selected for setup
menu No. 200 (PARA RUN). [However, external control can no longer be exercised from
the REMOTE connector (9-pin) when this setting has been made.]
FF
F TC/CTL switch
FF
By pressing this switch, what appears on the counter display is changed between TC and
CTL.
When TC is selected, either the TC or UB value is displayed depending on the position
selected by the TC/UB switch.
GG
G TC/UB switch
GG
This selector switch determines whether the value of TC or UB appears on the counter
display when the TC/CTL switch has been set to TC.
HH
H INT/EXT switch
HH
INT:For using the built-in time code generator.
EXT:For using the external time code, which is input from the time code input connector
or from the video signal. This selection is set using setup menu item No.507 [EXT
TC SL (HD)]or No.516 [EXT TC SL (SD)].
II
I TAPE/EE switch
II
<In the stop mode>
TAPE: For outputting the signals played back from the tape.
EE:For outputting the input signals selected by the setup menus No. 600 (VIDEO IN
SEL) and No. 700 (AUDIO IN SEL).
<In the editing*/recording mode>
TAPE: For outputting the simultaneous playback signals.
EE:For outputting the input signals selected by the setup menus No. 600 (VIDEO IN
SEL) and No. 700 (AUDIO IN SEL).
* The SETUP menu No. 302 (CONFI EDIT) setting is required.
– 9 –
Controls and their functions
<Front Panel Center Section>
JJ
J REMOTE/LOCAL switch
JJ
This switch is set when the unit is to be controlled from an external source using the
REMOTE connector, RS-232C connector or parallel connector.
REMOTE: Set to this position when controlling the unit by a device connected using the
9-pin REMOTE connector or RS-232C/parallel connector.
LOCAL:Set to this position when controlling the unit using the controls on its own
operation panel.
KK
K REMOTE lamp
KK
This lights when the REMOTE/LOCAL switch has been set to the REMOTE position.
LL
L Search button
LL
This button is pressed to establish the search mode.
When the search dial is set to the shuttle mode and turned to a particular position, and this
button is pressed, playback commences at the speed set by the search dial.
MM
M JOG/SHTL/SLOW lamps
MM
These indicate the present status of the search dial and SHTL/SLOW switch.
JOG:This lights when the unit is in the JOG mode.
SHTL:This lights when the unit is in the SHTL mode.
SLOW:This lights when the unit is in the SLOW mode.
NN
N SHTL/SLOW switch
NN
This selector switch is set when the search dial is used for SHTL or SLOW applications.
OO
O REV/STILL/FWD lamps
OO
One of these lamps lights depending on the operation of the search dial.
REV:This lights when the dial is turned counterclockwise and the tape travels in the
REV direction provided that the lamp in the search button has lighted.
STILL:This lights in the JOG mode while the dial is kept stationary, and the tape stops
traveling provided that the lamp in the search button has lighted.
It lights in the SHTL mode provided that the dial is at the STILL position.
FWD:This lights when the dial is turned clockwise, and the tape travels in the FWD
direction provided that the lamp in the search button has lighted.
PP
P Search dial
PP
This is used to search for the edit points.
Each time it is pressed, the mode is alternately set to shuttle or jog, and one of the JOG,
SHTL and SLOW lamps lights. When the power has been turned on, the dial will not
function until it has first returned to the STILL position.
Shuttle mode: When the dial is turned and stopped at a particular position while the
SHTL/SLOW switch is at SHTL, the tape can be played back at the speed
corresponding to the dial’s rotary angle position. A still picture appears at
the dial’s center position.
Slow mode:When the dial is turned all the way counterclockwise with the SHTL/SLOW
switch at SLOW, the tape speed is set to –4.9× normal speed, when it is
set to the center position, a still picture is produced, and when it is turned
all the way clockwise, the tape speed is set to +4.9× normal speed. The
speed for SLOW can be set using setup menu No. 308 (VAR FWD MAX)
and No. 309 (VAR REV MAX).
Jog mode:In this mode, the dial has no click-stop positions, and the tape is played
back in accordance with the speed at which the dial is turned within the
speed range which has been set using setup menu item No.310 (JOG
FWD MAX) and No.311 (JOG REV MAX).
– 10 –
Controls and their functions
<Front Panel Center Section>
QQ
Q PREROLL button
QQ
This is used for feeding and cueing the tape for manual editing.
When it is pressed, the tape travels to the preroll point where it stops.
The preroll time can be set on the setup menu No. 000 (P-ROLL TIME).
When this button is pressed together with the IN or OUT button, the tape can be cued to
the IN or OUT point entered.
When the AUTO ENTRY on the setup menu No. 305 is set to “ENA”, IN point has been
entered at the point where the PREROLL button is pressed even if the IN point has not
been entered.
RR
R AUTO EDIT button
RR
Automatic editing is executed when this is pressed after an edit point has been entered.
When the AUTO EDIT button is pressed though the IN point has not been entered,
automatic editing is executed using the point at which the button was pressed as the IN
point.
SS
S PREVIEW/REVIEW buttons
SS
PREVIEW: When this is pressed after an edit point has been entered, the tape travels,
editing is not performed, and the preview can be activated on the screen
connected to the recorder.
If it is pressed when the IN point has not been entered, the point at which the
button was pressed is entered as the IN point, and preview is executed
accordingly.
REVIEW: If this is pressed after a block has been edited, the now edited block can be
played back and monitored on the screen connected to the recorder.
TT
T IN (A IN)/SET/OUT (A OUT) buttons
TT
When IN (A IN) or OUT (A OUT) button is pressed together with the SET button, the IN (A
IN) or OUT (A OUT) point is entered.
A IN and A OUT are used during audio split editing to enter an audio IN or OUT point that
differs from the video In or OUT point.
While an IN (A IN) or OUT (A OUT) point is selected, the IN (A IN) or OUT (A OUT) button
corresponding to the point entered lights. When this button is pressed after a point has
been entered, the IN (A IN) /OUT (A OUT) point value appears on the counter display.
When the IN (A IN) or OUT (A OUT) button is pressed together with the RESET button, the
IN (A IN) or OUT (A OUT) point is cleared.
UU
U TRIM buttons
UU
These buttons are used to trim IN or OUT point finely.
When the “+” or “–” button is pressed while the IN or OUT button is held down, the entered
edit point can be trimmed in 1-frame increments. When the “+” button is pressed, the tape
is advanced by one frame; when the “–” button is pressed, it is rewound by one frame.
VV
V ASMBL button
VV
This is pressed for assemble editing.
The button is self-illuminating, and it is set ON (lamp lights) when it is pressed once and
OFF (lamp goes off) when it is pressed again.
WW
W INSERT buttons
WW
Press one of these seven buttons to select the input signals to be edited during insert
editing.
The buttons are self-illuminating, and they are set ON (lamp lights) when they are pressed
once and OFF (lamp goes off) when they are pressed again.
The audio channels (CH1 to CH8) are allocated to CH1-4 or CH5-8 using the AUDIO CH
SELECT button Z.
– 11 –
Controls and their functions
<Front Panel Center Section>
XX
X Counter display area
XX
The TC and CTL count values, UB and messages are displayed in this area.
Cassette inserted display lamp:
This lamp lights when a cassette has been inserted into the unit.
DV lamp:
This lights when a cassette recorded using the DV (SP mode) format is being played back.
DVCAM lamp:
This lights when a cassette recorded using the DVCAM format is being played back.
DVCPRO lamp:
This lights when a cassette recorded using the DVCPRO format is being played back.
DVCPRO50 lamp:
This lights when a cassette recorded using the DVCPRO50 format is being played back.
DVCPRO50P lamp:
This lights when a cassette recorded using the DVCPRO50p format is being played back.
LP lamp:
This lights when a cassette is being recorded or played back using the DVCPROHD-LP
format.
SP lamp:
This lights when a cassette recorded using the DVCPROHD format is being played back.
SCH lamp:
This lights when the SCH phase of the SD REF signal is within a fixed range.
CF lamp:
This lights when the color framing is locked.
TC/UB lamp:
This flashes when the TC or UB information cannot be read during tape playback; it
remains lighted while the information is being read properly.
W lamp:
This lights when a warning has been issued.
YY
Y Time code buttons
YY
These are used to set the TC or UB value.
SHIFT: When setting the TC or UB value, first press this button to stop the data running.
Change the digit now flashing on the display.
Each time the button is pressed, the flashing moves to the right by one digit, and
when it reaches the right-most digit, it returns to the left-most digit.
When it is kept depressed, the flashing moves consecutively.
ADJ:This is used to change the numeral of the digit now flashing on the display.
When the button is pressed once, the number is incremented by 1, and when it is
kept depressed, the number is incremented consecutively.
START: This enters the data which has been changed by the SHIFT and ADJ buttons.
Also, Pressing this button when the TC or UB value are not set enables the TCG
or UBG setting values to be confirmed.
RESET: When this button is pressed in the CTL mode, the display is reset to
“00:00:00:00”. In the CTL mode, the entered edit points are cleared.
In the TC/UB mode, the generator is reset when the button is pressed together
with the SHIFT button.
ZZ
Z Audio channel selector button
ZZ
This button is used to switch the display and control of the CH1-CH4 or CH5-CH8 audio
meter and volume and insert buttons.
– 12 –
Controls and their functions
<Front Panel Center Section>
[ [
[ Level meter
[ [
This displays the levels of the PCM audio signals for CH1, CH2, CH3 and CH4 (or for
CH5, CH6, CH7 and CH8) and CUE track signals.
During recording and E-E selection, it displays the levels of the audio input signals; during
playback, it displays the levels of the audio output signals.
\\
\ Audio input/output level controls
\\
These controls are used to adjust the recording and playback levels of the PCM audio
signals (CH1/CH2/CH3/CH4/CH5/CH6/CH7/CH8) and the CUE track signal.
The upper controls are for adjusting the recording levels.
The lower controls are for adjusting the playback levels.
Each control is a “pull for variable” control, meaning that the level can be adjusted only
when the control has been pulled up. The signal levels are set to the unity value (preset
value) when the controls have been pushed down.
Furthermore, when the channels have been switched between CH1-4 and CH5-8 using
the AUDIO CH SELECT button Z, the previous information is retained until the controls
are next operated.
]]
] Headphones jack
]]
The sound being recorded, played back or edited can be monitored on stereo headphones
when they are connected to this jack.
^^
^ Volume control
^^
This is used to adjust the headphones volume and the monitor output volume.
Whether the headphones output and monitor output volumes are to be linked or kept
separate can be set on the setup menu No. 713 (MONI OUT). (Note that the headphones
output volume is normally linked.)
When the volumes are kept separate, the monitor output is set to the unity value (preset
value).
__
_ MONITOR SELECT switches
__
These are used to select the audio signals output to the monitor L/R channels.
Each time the “L” button is pressed, the signals output to the monitor L channel are
selected in turn in the following order: CH1, CH2, CH3, CH4, CH5, CH6, CH7, CH8, CUE
and back to CH1.
[However, this switching is disabled when the channel except OFF has been selected for
setup menu No. 734 (MONITOR MIX L).]
Each time the “R” button is pressed, the signals output to the monitor R channel are
selected in turn in the following order: CH1, CH2, CH3, CH4, CH5, CH6, CH7, CH8, CUE
and back to CH1.
[However, this switching is disabled when the channel except OFF has been selected for
setup menu No. 735 (MONITOR MIX R).]
The L or R lamp on the level meter display lights to indicate which signal is now being
selected. (When the unit is set to “AUTO” in No. 745 (MONI CH SEL) on the setup menu,
then the display will change according to the monitor output.)
The lamp flashes if the channels selected by AUDIO CH SELECT do not appear on the
display screen.
``
` METER (FULL/FINE) selector switch
``
This is used to change the scale display (graduations) of the audio level meters.
FULL mode: Standard scale (from –¶ to 0 dB)
FINE mode: The scale changes every 0.5 dB.
– 13 –
Controls and their functions
<Front Panel Bottom Section>
aa
a User assignment switch
aa
This enables the VTR statuses and programmable menus to be registered.
Refer to page 18 for details.
bb
b Status selector switch
bb
This enables the statuses to be registered by the user assignment switch in 3 ways.
Refer to page 18 for details.
cc
c Programmable menu selector switch
cc
This enables the programmable menus to be registered by the user assignment switch in
4 ways.
Refer to page 18 for details.
dd
d MENU button
dd
When this is pressed, the setup menu appears on the TV monitor (when the HD SDI
MONITOR, SD SDI MONITOR and VIDEO OUT3 connectors are being used).
The setup menu numbers and items are displayed on the unit’s top front display area.
Press the button again to exit the setup menu settings and return to the original status.
ee
e SET button
ee
When this is pressed, the data which has been set on the setup menu is entered. After
data entry, the setup menu setting mode is exited and the original operating mode is
restored.
ff
f DIAG button
ff
When this is pressed, VTR information is displayed on-screen. When it is pressed again,
the original display is restored.
There are two types of VTR information: “HOURS METER” information and “WARNING”
information. Switching between these types is enabled by pressing the search button.
Indicated on the “HOURS METER” screen are the power-on time, drum rotation time, tape
travel time, loading count and power ON/OFF time, etc.
Indicated on the “WARNING” screen are the warning.
g MODE/SEL button
This is used to initiate a MULTI CUE operation or other expansion mode operation. For
details, refer to page 46.
h EXIT button
This is used to exit from the MULTI CUE operation or other expansion mode operation and
return to the original mode.
– 14 –
Controls and their functions
Connector area
SIGN
2
GD
>
;
=
HD SDI
<
OUT 1INOUT 2OUT 3
ACTIVE
THROUGH
SDTI
SD SDI
AUDIO
CH1Æ2
IN
IN
(OPTION)
OUT
PUSH
MONITOR
(SUPER)
VIDEO OUT
1
2
(WFM)
(SUPER)
3
AUDIO
OUT
CH1Æ2
ANALOG
SD REF IN
?@B
CH3Æ4CH5Æ6CH7Æ8
CH3Æ4CH5Æ6CH7Æ8
DIGITAL AUDIO
HD REF INHD REF OUT
ON
75≠
OFF
A
4
AC IN
L
1
125V 5A
3
5
6
TC
CUEMON
ININL
OUT
OUTR
CH 1
PUSHPUSHPUSH
FUSE
CH 1CH 2CH 3CH 4
:
9
8
7
PUSHPUSH
AUDIO IN
CH 2CH 3CH 4
AUDIO OUT
MONITOR (SUPER)
ON
75≠
OFF
SD
REF OUT
R
RS-232C
E
M
O
T
E
C
D
PARALLEL
ENCODER
REMOTE
4
FGH
REMOTE
IN/OUT
REMOTE
OUT
E
1 AC IN connector
This is for connecting the unit to the power outlet using the power cord provided.
2 SIGNAL GND terminal
This terminal is connected to the signal ground terminal of the connected unit in order to
reduce noise. It is not connected to ground for safety purposes.
3 Fuse holder
This contains a fuse.
4 Fan motor
This is for cooling the unit.
The W lamp lights when trouble has caused the fan motor to stop. If the unit is still
operated in the warning status, the temperature inside the deck will rise, and when it
exceeds the safety temperature, all the unit’s operations will be shut down.
– 15 –
Controls and their functions
<Connector area>
5 TIME CODE IN connector
This is the connector for recording the external time code on the tape.
6 TIME CODE OUT connector
The playback time code is output from this connector during playback.
During recording, the time code generated by the internal time code generator is output.
7 CUE IN connector
The analog signal to be recorded on the CUE track is supplied to this connector. The audio
signals from a microphone can also be recorded by selecting the –60dB input mode on the
setup menu No. 705 (CUE IN LV).
8 CUE OUT connector
The analog signal recorded on the CUE track is output from this connector.
9 MONITOR OUT connector
During playback, the playback signals from the CUE track or PCM audio signal CH1, CH2,
CH3, CH4, CH5, CH6, CH7 and CH8 are output from this connector.
: ANALOG AUDIO IN connectors
These are the input connectors for the analog audio signals (CH1, CH2, CH3, CH4).
; ANALOG AUDIO OUT connectors
These are the output connectors for the analog audio signals (CH1, CH2, CH3, CH4).
<<
< HD SERIAL DIGITAL COMPONENT AUDIO VIDEO IN/OUT connectors/ACTIVE
<<
THROUGH
These are the input and output connectors for the HD digital component audio and video
signals that comply with the SMPTE 292M standard.
The TC, menu or other information is output from the HD SDI MONITOR connector with
the information superimposed onto the signals.
ACTIVE THRU (SD up-converter, optional accessory)*
*1: Connector for the input/output signals of compressed data complying with the SMPTE
305M, 321M standard
*2: Input connector enabling SD SDI signals complying with the SMPTE 259M-C standard
to be up-converted to the HD format and recorded
>>
> SD SERIAL DIGITAL COMPONENT AUDIO VIDEO OUT connectors
>>
These are the output connectors for the digital component audio and video signals that
comply with the SMPTE 259M-C, 272M and 294M standards.
The signals are output during the playback of compatible DVCPRO25M, 50M, DV or
DVCAM format tapes or during down-conversion output.
The TC, menu or other information is output from the SD SDI MONITOR connector with
the information superimposed onto the signals.
Using setup menu item No.606 (SD MONI O SEL), the SD SDI MONITOR output signals
can be set to the same output as the SD SDI OUT1 (no superimposing).
When “SD SDI” has been selected as the setup menu item No.600 (VIDEO IN SEL)
setting and “THRU” as the No.107 (EE MODE SEL) item setting, the SD SDI MONITOR
output in the EE mode will not be subject to superimposing, and it will be set to the same
output as SD SDI OUT1. (The AJ-UC1500 board available as an optional accessory is
needed for “SD SDI” to be selected as the setup menu item No.600 setting.)
2
– 16 –
Controls and their functions
<Connector area>
??
? ANALOG COMPOSITE VIDEO OUT connectors
??
These are the output connectors for the analog composite video signals.
The signals are output during the playback of compatible DVCPRO25M, 50M, DV or
DVCAM format tapes or during down-conversion output.
Video signals with information superimposed onto them can be output from the VIDEO
OUT3 connector.
Whether information is to be superimposed or not (ON/OFF) is selected by setting the
setup menu No.005 (SUPER) item.
The VIDEO OUT2 connector can also be used as the WFM (waveform) OUT connector.
TC, CTL, VIDEO, RF L/R and ENV L/R are the signals which can be selected on the
menu.
@@
@ SD REF IN connectors and 75-ohm termination switch
@@
These are the input connectors for the SD reference video signals.
Input the NTSC signals with color burst.
To terminate, set the switch to ON.
AA
A HD REF IN connectors and 75-ohm termination switch
AA
This is the input connectors for the HD reference video signals.
Input tri-level sync signals with positive and negative polarities.
To terminate, set the switch to ON.
B B
B HD REF OUT connector
B B
This is the output connector for the HD reference video signals used for external
synchronization.
It outputs tri-level sync signals with positive and negative polarities.
CC
C SD REF OUT connector
CC
This is the output connector for the NTSC external synchronization signal (black burst
signal).
D DIGITAL AUDIO IN/OUT connector
This I/O connector is for digital audio signals which comply with the AES/EBU standard.
E Remote control connectors
The unit can be controlled from an external source by connecting the unit with another unit
or an external controller.
There are two remote control connectors, one for IN/OUT uses and the other for OUT
uses.
IN/OUT: For connection with an external controller.
For connection with deck-to-deck operation.
OUT:For connection with parallel running operations.
For use in a loop-through configuration.
F ENCODER REMOTE connector
The external encoder/controller is hooked up to this connector when the video output
signal and other settings are to be adjusted from an external source.
G RS-232C connector
H PARALLEL REMOTE connector
This is used when operating the unit from an external source.
– 17 –
Operations using the front panel bottom controls
The desired status information and setup menu items can registered in the STATUS 1 to 3
buttons b and PROG MENU 1 to 4 buttons c by using the SETUP, STATUS, PROG MENU
and SAVE/EXIT buttons a. Once the information has been registered, it can be indicated on
the VTR status display area 3 by pressing the STATUS 1 to 3 buttons b or PROG MENU 1
to 4 buttons c concerned.
PROG
SET UP
STATUS
MENU
SAVE/
EXIT
a
Items which can be registered
The following items can be registered in the buttons.
STATUS:Up to 9 items including the recording format and playback format can be
•
registered in these buttons. (Refer to the VTR status item table for
descriptions of the items and contents.)
PROG MENU: Up to 9 items from setup menus in the 000 range to 700 range can be
•
registered in these buttons. However, the submenus of setup menu item
No.680 (BLANK LINE) cannot be registered.
Registration method
The items are registered as they are selected by the menu-driven system. Connect the TV
monitor to the VIDEO OUT3 connector in the unit’s connector area and display the
registration menu.
STATUS
123
b
PROG MENU
1234
c
MODE/SEL EXIT
MENU SET DIAG
1
Press the SETUP button.
The message indicating that the registration steps can now be commenced appears on
the TV monitor.
-ASSIGNMENT MODE-
select any key!
MENU :<PROG MENU>
STATUS :<STATUS>
EXIT :<SETUP>
2
Select the button which corresponds to the objective.
PROG MENU buttons:The registration menu for registering the setup menu items in
•
the PROG MENU 1 to 4 buttons is displayed.
STATUS buttons:The registration menu for registering the VTR status
•
information in the STATUS 1 to 3 buttons is displayed.
SETUP buttons:This cancels the registration operation.
•
– 18 –
Operations using the front panel bottom controls
3
Turn the search dial and select the item to be registered.
The cursor (¢) on the menu screen now moves.
∫Example of the menu displayed for registering setup menu items
ASSIGN-MENU BASIC
<USER> N0.000 - 1---
¢
000 P-ROLL TIME 1-- 001 LOCAL ENA -2- 002 TAPE TIMER --3 003 REMAIN SEL --- 004 SYNCHRONIZE --- 005 SUPER --- 006 DISPLAY SEL --- 007 CHARA H-POS --- 008 CHARA V-POS ----
∫Example of the menu displayed for registering VTR statuses
ASSIGN-MENU
<STATUS> N0.000 - 1---
¢
000 REC FORMAT 1-- 001 REF OUT -2- 002 PB FLD RATE --3 003 REC FLD RATE --- 004 HD OUT --- 005 SD OUT --- 006 UFC --- 007 SETUP NUMBER --- 008 TAPE SPEED ----
4
When registering setup menu items: At the position of the item to be registered,
select the PROG MENU button (1, 2, 3 or 4) in
which the information is to be registered, and
press it.
When registering VTR statuses:At the position of the item to be registered,
select the STATUS button (1, 2 or 3) in which
the information is to be registered, and press it.
The number of the button corresponding to the button that was pressed is now
displayed. When the same button is pressed again, the button number display is
released.
5
To register more items, repeat steps 3 and 4.
6
Press the SAVE/EXIT button.
The registered information is now saved in the memory. (When more than one item
has been registered, the information will be stored in sequence starting with the lowest
item number.)
To return the registered information to the state prior to registration, press the STOP
button.
– 19 –
Operations using the front panel bottom controls
∫ To return the registered information to the factory settings (initial settings), press
the RESET button while the registered menu item is displayed. The following
message will appear.
∫Example of the menu displayed for resetting setup menu items which have been
PLAY button:Whatever items have been registered in the PROG
MENU 1 to 4 buttons b are reset to the factory
settings.
PROG MENU 1 to 4 buttons:The button which was pressed is returned to the non-
registration status.
CANCEL button:This is for canceling the reset operation.
∫Example of the operation menu displayed for resetting VTR statuses which have
been registered
ASSIGN-MENU INIT SET
select any key!
ALL <PLAY>
STATUS1 <STATUS1>
STATUS2 <STATUS2>
STATUS3 <STATUS3>
CANCEL <STOP>
PLAY button:Whatever statuses have been registered in the STATUS 1 to 3
buttons c are reset to the factory settings.
STATUS 1 to 3 buttons: The button which was pressed is returned to the non-
registration status.
CANCEL button:This is for canceling the reset operation.
– 20 –
Operations using the front panel top controls
What has been registered in the STATUS 1 to 3 buttons b and PROG MENU 1 to 4 buttons
c located at the bottom of the panel can be called to the VTR status display area 3 by
pressing the button concerned.
The called item can be operated using the buttons shown below.
CH CONDITIONENTER ESCAPESHIFT
567
8
1-1 VTR status displays
When the power is turned on, the information registered in the STATUS 1 button appears on
the display, and after this point what is displayed can be switched by pressing the STATUS 1
to 3 buttons b.
[Example of status display]
RlE0C8F0RiMRIENFTO5U9T...........
.
≥
Each item consists of 6 characters. Three items can be displayed at the same time.
The names of the items appear on the first line, and their statuses on the second line.
≥
When the number of registered items is 4 or more, press the SCROLL buttons 5 to scroll
the display to the left or right.
≥
When the number of registered items is less than 3, “.....” appears in the sections where
items have not been registered.
2-1 Registered menu item displays
The registered setup menu items are displayed by pressing the PROG MENU 1 to 4 buttons
c.
[Example of registered menu item display]
¢ PL_ORCOALLL
ETNIA
ME
ST&5EsJ
Digit 1:Cursor (¢) for selecting items/mark (!) indicating that a setting is being
changed
Digits 2 to 13:Name of the menu item (12-character display)
Digit 14:Cursor for selecting item
Digits 15 to 20: Setting (6-character display)
≥
Two registered menu items can be displayed at the same time.
≥
When the number of registered items is 3 or more, press the SCROLL buttons 5 to scroll
the display up or down.
≥
The data in the currently selected user file (USER1 to USER5) is reflected in the settings.
– 21 –
Operations using the front panel top controls
2-2 How to change a registered menu setting
Selecting the menu item:Press the SCROLL buttons 5 to move the item
selection cursor (¢) up or down, and select the menu
item.
Transferring to the change mode: Press the ENTER button 6 to transfer to the setting
change mode. Whether operation has transferred to
the change mode is confirmed by the movement of the
item selection marker to digit 14.
Changing the setting:Press the scroll buttons 5 to change the setting.
When a change has been made to the current setting,
the mark (!) indicating that a setting is being changed
appears at digit 1 to indicate the status.
!PL_ORCOALLL
ETNIA
≥
If the item allows for a wide range of variation in its
setting, continue to press one of the SCROLL buttons
5 while holding down the SHIFT button 8, and the
setting can be incremented or decremented at a
higher speed.
Entering the setting:Press the ENTER button 6 to enter the setting change
and return to the menu selection status.
Canceling the change:Press the ESCAPE button 7 to cancel the setting
change and return to the menu selection status.
<Note>
When the user file now selected is one of USER2–USER5, the setup menu No. A03 (MENU LOCK)
selection is 1 (lock setting), you cannot go to the set-value change mode.
ME¢
ST&7EsJ
– 22 –
Operations using the front panel top controls
VTR status item table
tem as it ap-
Name of registration
menu item
000
001
002
003
004
005
006
007
008
REC FORMAT
REF OUT
PB FLD RATE
REC FLD
RATE
HD OUT
SD OUT
UFC
SETUP
NUMBER
TAPE SPEED
I
pears on VTR
status display
REC FMT
REFOUT
PB_FLD
RECFLD
HD_OUT
SD_OUT
UFC
SETUP
SPEED
This indicates the recording format.
1080i:The tape is recorded using the 1080i format.
720p:The tape is recorded using the 720p format.
This displays the output reference status.
HD_59:The HD REF input signal has been selected as
the reference. The field frequency is 59.94 Hz.
IN_59:The HD serial input signal has been selected
as the reference. The field frequency is 59.94
Hz.
INT59:The signal from the internal generator (59.94
Hz) is selected as the reference.
NTSC59: The SD REF input signal has been selected as
the reference. The field frequency is 59.94 Hz.
INT59N: SD REF has been selected by the OUT REF
setting. Since the SD REF signal is not input,
the signal from the internal generator (59.94
Hz) is used.
This indicates the field frequency at which the recording
was made on the tape as ascertained from the tape’s
playback signals.
59.94:The tape has been recorded at a field frequency of 59.94 Hz.
This indicates the field frequency at which the recording
is to be made on the tape.
59.94:The recording will be made on the tape at a
field frequency of 59.94 Hz.
This indicates the format of the HD serial output.
1080i:The HD serial output uses the 1080i format.
720P:The HD serial output uses the 720p format.
NONE:Output is in a state of mute according to the
setting of the setup menu No. 630 - No. 633.
This indicates the format of the SD serial output.
480i:The SD serial output is in the 480i format.
480P:The SD serial output is in the 480p format.
NONE:Output is in a state of mute according to the
setting of the setup menu No. 630 - No. 633.
This indicates the status of HD-SD format converter
board.
LN_CON: The line converter is operating.
UP_CON: The up-converter is operating.
DW_CON:
This indicates the user file No. of the setup menu.
USER1:USER1 is selected.
USER2:USER2 is selected.
USER3:USER3 is selected.
USER4:USER4 is selected.
USER5:USER5 is selected.
This indicates the tape speed in JOG/SLOW/SHTL mode.
JOG mode: REV (reverse)/STILL (stop)/FWD (forward)
SLOW mode: Current speed is indicated.
SHTL mode: Current speed is indicated.
Other than
above:Indication is blank.
The down-converter is operating.
is indicated.
Description of display
– 23 –
Connections
Connections when one unit is used
Set the CONTROL switch on the front panel to LOCAL.
HD SDI input (audio/video) connector
SDTI input (when the SDTI interface board, available as an
optional accessory, has been installed)
SD SDI input (when the SD input up-converter board, available
as an optional accessory, has been installed)
SDTI output (when the SDTI board, available as an
optional accessory, has been installed)
SD SDI input/active through (when the SD input up-converter board,
available as an optional accessory, has been installed)
Audio monitor output connectors
TC
CUEMON
PUSHPUSH
ININL
OUT
OUTR
AUDIO IN
CH 1
CH 2CH 3CH 4
PUSHPUSHPUSH
FUSE
AC IN
125V 5A
SIGN
L
GD
AUDIO OUT
CH 1CH 2CH 3CH 4
Analog audio input connectors
Analog audio output connectors
HD SDI input active-through connector
SD SDI output connector
Digital audio input
connectors
Digital audio output
connectors
HDSDI
IN
OUT
SDTI
(OPTION)
PUSH
ACTIVE
THROUGH
SD SDI
MONITOR
(SUPER)
VIDEO OUT
1
2
(WFM)
(SUPER)
3
OUT 1INOUT 2 OUT 3
AUDIO
CH1Æ2
IN
CH1Æ2
AUDIO
OUT
ANALOG
SD REF IN
MONITOR (SUPER)
CH3Æ4 CH5Æ6 CH7Æ8
CH3Æ4 CH5Æ6 CH7Æ8
DIGITAL AUDIO
HD REF IN HD REF OUT
ON
ON
75≠
75≠
OFF
OFF
SD
REF OUT
R
RS-232C
E
M
O
T
E
PARALLEL
ENCODER
REMOTE
HD reference input connector (active-through output)
Video monitor output connector
(COMPOSITE OUT 3 systems)
– 24 –
Connections
Connections when 2 units are used (deck to deck)
Source machine:
Recorder:
To audio monitor
Source machine
TC
ININL
OUT
CH 1
FUSE
AC IN
125V 5A
CH 1 CH 2 CH 3 CH 4
SIGN
L
GD
SD reference signal generator
Set the CONTROL switch on the front panel to REMOTE.
•
Set the CONTROL switch on the front panel to LOCAL.
•
HD SDI signal
device
To audio monitor
Recorder
CUE MON
HD SDI
PUSHPUSH
OUTR
CH 2 CH 3 CH 4
PUSHPUSHPUSH
AUDIO IN
AUDIO OUT
ACTIVE
THROUGH
SD SDI
SDTI
IN
(OPTION)
OUT
MONITOR
(SUPER)
PUSH
To video
monitor device
OUT 1INOUT 2 OUT 3
AUDIO
IN
AUDIO
OUT
VIDEO OUT
1
2
(WFM)
(SUPER)
3
SD REF IN
CH1Æ2
CH1Æ2
ANALOG
DIGITAL AUDIO
ON
OFF
OFF
MONITOR (SUPER)
CH3Æ4 CH5Æ6 CH7Æ8
CH3Æ4 CH5Æ6 CH7Æ8
HD REF IN HD REF OUT
ON
75≠
75≠
OFF
SD
REF OUT
R
RS-232C
E
M
O
T
E
PARALLEL
ENCODER
REMOTE
REMOTE
IN/OUT
REMOTE
OUT
AC IN
SIGN
L
GD
Remote control signal (9P)
device
TC
CUE MON
ININL
OUT
OUTR
CH 1
CH 2 CH 3 CH 4
PUSHPUSHPUSH
FUSE
125V 5A
CH 1 CH 2 CH 3 CH 4
monitor device
PUSHPUSH
AUDIO IN
AUDIO OUT
To video
OUT 1INOUT 2 OUT 3
HD SDI
ACTIVE
THROUGH
SD SDI
SDTI
AUDIO
IN
IN
(OPTION)
AUDIO
OUT
OUT
MONITOR
(SUPER)
PUSH
SD REF IN
VIDEO OUT
1
2
(WFM)
(SUPER)
3
CH1Æ2
CH1Æ2
ANALOG
DIGITAL AUDIO
ON
OFF
MONITOR (SUPER)
CH3Æ4 CH5Æ6CH7Æ8
CH3Æ4 CH5Æ6CH7Æ8
HD REF IN HD REF OUT
ON
75≠
75≠
OFF
SD
REF OUT
R
RS-232C
E
M
O
T
E
PARALLEL
ENCODER
REMOTE
REMOTE
IN/OUT
REMOTE
OUT
ON
– 25 –
Connections
Connections with editing controller
AV monitor
Video monitor signals
Audio monitor signals
Editing controller
Recorder
ON
OFF
POWER
METER
FULL/FINE
L
MONITOR SELECT
R
LEVEL
CH 1/5 CH 2/6 CH 3/7 CH 4/8 CUE
PULL FOR VARIABLE
HEADPHONES
PULL
OPEN
Remote
CH CONDITIONENTER ESCAPE SHIFT
RESET
TC/CTL
TC SET
AUDIO CH SELECT
SHIFT ADJ
CH 1
ASMBL
1
REC
PREVIEW
REVIEW
PB
CH 4
VIDEO
CH1/5 CH2/8 CH3/7 CH4/8 CUE TC
2 3 4 5 6 7 8
MULTICUE
AUTO EDIT
START
CH 5 CH 8
INSERT
TRIM
PREROLL
A IN
A OUT
SET
IN
OUT
To REMOTE IN/OUT
connector
M-cassette / ADAPTER
Do not insert S-cassette without adaptor
MODE
TC INTTCTAPE
UB
EXT EE
STAND BY
PLAYER
SERVO
EDIT PLAY
REW STOP
EJECT
CONTROL
PUSH
REMOTE
JOG SHTL
SLOW
REVFWD
LOCAL
RECORDER
REC INHIBIT
REC
FF
PULL
OPEN
Video input signals
Audio input signals
Video monitor signals
AV switcher
AV monitor
Audio monitor
signals
Reference
signal generator
ON
OFF
CH CONDITIONENTER ESCAPE SHIFT
POWER
METER
FULL/FINE
L
MONITOR SELECT
R
LEVEL
CH 1/5 CH 2/6 CH 3/7 CH 4/8 CUE
HEADPHONES
PULL
OPEN
PULL FOR VARIABLE
REC
PREVIEW
REVIEW
PB
Source machine
Video monitor
AUDIO CH SELECT
CH 1
CH 4
CH 5 CH 8
ASMBL
VIDEO
CH1/5 CH2/8 CH3/7 CH4/8 CUE TC
1
2 3 4 5 6 7 8
MULTICUE
AUTO EDIT
PREROLL
signals
RESET
TC/CTL
TC SET
SHIFT ADJ
START
INSERT
TRIM
A IN
A OUT
SET
IN
OUT
Remote
To REMOTE
IN/OUT connector
M-cassette / ADAPTER
Do not insert S-cassette without adaptor
MODE
CONTROL
RECORDER
PUSH
REMOTE
JOG SHTL
REVFWD
LOCAL
REC INHIBIT
REC
FF
TC INTTCTAPE
UB
EXT EE
STAND BY
PLAYER
SERVO
EDIT PLAY
REW STOP
Audio monitor
signals
Audio output
Video output signals
signals
Remote
Reference signal
Audio output signals
Video output signals
To REMOTE
IN/OUT connector
PUSH
JOG SHTL
SLOW
REVFWD
EJECT
PULL
OPEN
EJECT
SLOW
PULL
OPEN
Reference signal
MONITOR SELECT
PULL
OPEN
ON
OFF
METER
FULL/FINE
L
R
HEADPHONES
POWER
LEVEL
CH CONDITIONENTER ESCAPE SHIFT
CH 1/5 CH 2/6 CH 3/7 CH 4/8 CUE
PULL FOR VARIABLE
CH 1
ASMBL
1
REC
PREVIEW
REVIEW
PB
AUDIO CH SELECT
CH 4
CH 5 CH 8
VIDEO
CH1/5 CH2/8 CH3/7 CH4/8 CUE TC
2 3 4 5 6 7 8
MULTICUE
AUTO EDIT
PREROLL
M-cassette / ADAPTER
Do not insert S-cassette without adaptor
MODE
CONTROL
TC INTTCTAPE
REMOTE
RESET
UB
EXT EE
LOCAL
TC/CTL
STAND BY
PLAYER
TC SET
SHIFT ADJ
INSERT
TRIM
A IN
SET
IN
RECORDER
START
SERVO
REC INHIBIT
EDIT PLAY
REC
REW STOP
FF
A OUT
OUT
Source machine
Audio monitor
Video monitor
signals
signals
AV monitorAV monitor
<Note>
If the remote signal (9P) connection is to be disconnected from one component and connected to another instead,
recheck the editing controller settings, etc.
– 26 –
Tapes
Type
Consumer DV/DVCAM
cassette
(S size cassette)
M size cassette
DVCPROHD
L size
cassette
(100 Mbps)
For consumer
use DV/DVCAM
Align the cassette tape with the center of the insertion slot, and gently push it inside. The cassette tape
is automatically loaded.
Description
These tapes are exclusively used with general consumer DV/DVCAMcamera/
recorder.
They can be played back on the unit if a cassette adapter AJ-CS750P (available
as an optional accessory) is used. However, bear in mind that long-playing
cassette tapes (80 minutes in the standard mode; 120 minutes in the LP mode.)
cannot be used.
It is recommended that Panasonic’s consumer-use DV tapes for general
consumer applications be used.
Bear in mind that inserting one of these tapes without first installing the cassette
adapter will cause malfunctioning.
Tapes with a maximum playback time of maximum of 64 minutes.
Tapes with a maximum recording/playback time of maximum of 92 minutes.
Standard playback cassette tapes for consumer use DV/DVCAM.
Use of Panasinic’s consumer-use DV tapes is recommended.
PUSH
JOG SHTL
SLOW
REVFWD
EJECT
PULL
OPEN
ON
OFF
POWER
METER
FULL/FINE
L
MONITOR SELECT
R
LEVEL
CH 1/5 CH 2/6 CH 3/7 CH 4/8 CUE
HEADPHONES
PULL
OPEN
CH CONDITIONENTER ESCAPE SHIFT
AUDIO CH SELECT
CH
1
CH
ASMBL
VIDEO
1
2 3 4 5 6 7 8
MULTICUE
REC
PREVIEW
PULL FOR VARIABLE
AUTO EDIT
REVIEW
PB
4
CH 5CH
8
CH1/5 CH2/8 CH3/7 CH4/8 CUE TC
INSERT
TRIM
PREROLL
A
IN
IN
SHIFT ADJ
SET
RESET
TC/CTL
TC SET
START
A
OUT
OUT
M-cassette / ADAPTER
Do not insert S-cassette without adaptor
MODE
TC INTTCTAPE
EXT EE
UB
STAND BY
PLAYER
SERVO
EDITPLAY
REW STOP
CONTROL
REMOTE
LOCAL
RECORDER
REC INHIBIT
REC
FF
M cassette
L cassette
<Notes>
General consumer tapes recorded in the LP mode cannot be played back.
•
The maximum speed at which general consumer DV/DVCAM tapes can be advanced is 32 times the
•
normal tape speed.
The maximum STILL mode time for general consumer DV/DVCAM tapes is set to 10 seconds..
•
Cueing up a general consumer DV/DVCAM tape at the same position should be kept to the minimum
•
in order to protect the tape from damage.
The maximum time for STILL TIMER when a general consumer DV/DVCAM tape is used is set to 10
•
seconds, and the total time during which such a tape may be left standing in the STILL mode is set to
1 minutes.
Before proceeding with editing material recorded on a consumer-use DV or DVCAM tape, first record
•
the material on a DVCPROHD tape or other tape used by VTRs for broadcast applications.
Noise may be produced when a consumer-use DV or DVCAM tape is used for slow-motion play.
•
– 27 –
Switching on the power/inserting the cassette
13
2
4
PULL FOR VARIABLE
ON
AUDIO CH SELECT
SHIFT ADJ
TC SET
START
TC/CTL
RESET
TC INTTCTAPE
UB
STAND BY
EDITPLAY
REWSTOP
SERVO
REC
FF
REC INHIBIT
PLAYER
EXT EE
MODE
REMOTE
PUSH
REVFWD
RECORDER
LOCAL
CONTROL
CH
1
1
ASMBL
PREVIEW
REVIEW
AUTO EDIT
PREROLL
TRIM
A
IN
IN
SET
OUT
A
OUT
MULTICUE
INSERT
VIDEO
CH1/5 CH2/8 CH3/7 CH4/8 CUE TC
CH
4
OFF
POWER
CH CONDITIONENTER ESCAPE SHIFT
METER
FULL/FINE
MONITOR SELECT
LEVEL
HEADPHONES
CH 1/5 CH 2/6 CH 3/7 CH 4/8 CUE
REC
L
R
PB
PULL
OPEN
PULL
OPEN
CH 5CH
8
23 45 67 8
JOGSHTL
SLOW
EJECT
M-cassette / ADAPTER
Do not insert S-cassette without adaptor
Before starting to operate the unit, check whether the equipment has been connected
properly.
1
Turn on the power.
2
Check that the AUTO OFF lamp is off.
When condensation has formed or some other trouble has occurred, the AUTO OFF
lamp lights, and all operations are disabled.
3
Insert the cassette tape.
Insert the tape at its proper position without force.
4
Check that the STOP lamp is on.
When the tape is inserted, the cylinder rotates automatically, the tape is loaded and the
unit goes into the stop mode. The EJECT lamp goes off.
– 28 –
STOP/STAND BY mode
PULL FOR VARIABLE
ON
AUDIO CH SELECT
SHIFT ADJ
TC SET
START
TC/CTL
RESET
TC INTTCTAPE
UB
STAND BY
EDITPLAY
REWSTOP
SERVO
REC
FF
REC INHIBIT
PLAYER
EXT EE
MODE
REMOTE
PUSH
REVFWD
RECORDER
LOCAL
CONTROL
CH
1
1
ASMBL
PREVIEW
REVIEW
AUTO EDIT
PREROLL
TRIM
A
IN
IN
SET
OUT
A
OUT
MULTICUE
INSERT
VIDEO
CH1/5 CH2/8 CH3/7 CH4/8 CUE TC
CH
4
OFF
POWER
CH CONDITIONENTER ESCAPE SHIFT
METER
FULL/FINE
MONITOR SELECT
LEVEL
HEADPHONES
CH 1/5 CH 2/6 CH 3/7 CH 4/8 CUE
REC
L
R
PB
PULL
OPEN
PULL
OPEN
CH 5CH
8
23 45 67 8
JOGSHTL
SLOW
EJECT
M-cassette / ADAPTER
Do not insert S-cassette without adaptor
2
1
1
When the STOP button is pressed, the unit goes into the stop mode. The STOP lamp
lights and the tape stops traveling.
In order to protect the tape, the unit goes into the standby OFF mode after the time set
•
by setup menu No. 400 (STILL TIMER) has elapsed. When the STOP, REW, FF or
PLAY button is pressed, the unit will go into the appropriate mode.
2
When the STAND BY button is pressed, the unit goes into the standby ON/OFF mode.
When the button’s lamp is lighted, the unit is in the standby ON mode.
When the button is pressed during the stop mode, the unit goes into the standby OFF
mode and half-loading mode and the lamp goes off.
When the button is pressed during the standby OFF mode, the unit goes to the standby
ON mode.
Still Timer Setting
Page 85 indicates the settings for menu item 400-Still Timer set. Still Timer settings 4 and
below will best protect the tape.
– 29 –
Recording
1
Set the accidental erasure prevention tab on the cassette tape to the “recording”
position and insert the tape.
2
Press the STOP button to place the unit in the stop mode.
3
Set the TAPE/EE switch to EE.
EE images now appear on the TV monitor.
4
Check that the REC INHIBIT lamp is off.
When this lamp is lighted, select “0 (OFF)” as the setup menu item No.113 (REC INH)
setting.
5
Select the video and audio input signals and adjust their levels.
5-1 Selecting video/audio input signals
1 Connect the signals to be recorded.
2 Select the input signals on the setup menus No. 600 (VIDEO IN SEL) and
NO.700 (AUDIO IN SEL).
5-2 Adjusting the audio level
1 Adjust the levels of the audio input signals in the audio CH1, CH2, CH3, CH4,
CH5, CH6, CH7, CH8 and analog cue channels selected by the setup menu
item No.700 setting. Normally, keep the audio input/output level controls \
pushed in (unity value).
The audio signals will be recorded at the proper level.
2 To adjust the recording level, pull out the controls \ and adjust them. With the
CUE signal, adjust the control in such a way that –20 dB will not be exceeded.
<Note>
When “CH1-CH4 (CH5-CH8)” is lighted at the audio channel selector display Z, the
audio input/output level controls \ and level meter [ will operate for CH1-CH4 (CH5CH8).
6
Press the PLAY button while holding down the REC button. The REC and PLAY lamps
light, and recording commences.
7
To end the recording, press the STOP button.
Recording is ended, and the unit goes into the stop mode.
<Note>
Check that the SERVO lamp is lighted during recording. If it flashes or if it is off, the images
•
played back will be disturbed.
– 30 –
Loading...
+ 96 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.