Panasonic AG6124 Service Manual

TechInfo Sheet fax: 01344 853689
Audio Visual email: av.technical@mail.panasonic.co.uk
Product Group: CCVE Model: AG6124 Date: 20/10/98 Revision No: 01 Document No: 01 Subject: Dead
1. Symptom: Dead, no output from power supply.
Cause: Fuse F1001 O/C
Remedy: Check and replace if necessary IC1001, R1019, R1020, R1021, R1022 & F1001.
Part Numbers
IC1001 STRM6545 IC1019 ERDS2FJ152 IC1020 ERX1SJR82 IC1021 ERDS2FJ471 IC1022 ERDS2FJ471
2. Symptom: Dead, no output from power supply.
Cause: Failure of power supply to start up.
Remedy: Replace IC1001 and D1003
Part Numbers
IC1001 STRM6545 D1003 MA178
3. Symptom: No control of VCR functions when using front panel controls.
Cause: Front operation panel lockup.
Remedy: Switch off unit at the mains supply. Switch unit back ON whilst trying to
load a tape. If a tape is already jammed this will require removal first.
Panasonic CS U.K. Document No: 01