Panamax MB1000 Specifications

UNINTERRUPTIBLE POWER SUPPLY
FOR YOUR HOME THEATER SYSTEM
MB1000
A Fully Programmable
UPS, Voltage Regulator
000
FEATURES:
• Surge Protection and AVM
• LiFT Noise Filtration
• Dual Learning IR Output Controls
• RS-232 with Open Source
Code Protocol
• Fully Programmable
• Power Management Software
• USB Interface
• Critical Load Management
• USB Cord Included
• RS232 Pin Cable Included
• Rack Mounting Kit
MB1
www.panamax.com
MB1000
FRONT/BACK PANELS FEATURES
Outlet Bank 1 Indicator
Illuminated blue when outlet bank 1
is switched on.
Power Switch
Press and hold the
power button for 2 seconds to turn the UPS ON or OFF.
Outlet Bank 2
Indicator
Illuminated blue
when outlet bank 2
is switched on.
Circuit Breakers for
Overload Protection
Resettable circuit
breakers provide
optimal overload
protection.
Outlet Bank 2 - Non-Critical-Load Outlets
Four battery powered, surge protected and AVR outlets
for connected equipment insures temporary uninter-
rupted operation of connected equipment during a power
failure. These outlets will shut off when the batteries
drain to a designated level to reserve remaining battery
charge from the critical load outlets.
Line Fault Indicator
This LED will illuminate in red to warn the user that a wiring problem such as a bad/missing ground or reversed wiring exists within the AC receptacle. If illuminated, disconnect all equipment and contact an electrician to insure outlet is properly wired.
10 Ft. AC Power Cord
Ground Lug
IR Detector
IR Detector, for sampling IR remote control signals.
Outlet Bank 1 - Critical Load Outlets
Four battery powered, surge protected and AVR outlets for critical-load equipment insures temporary uninterrupted operation of connected
equipment during a power failure.
Menu Navigation Knob
Rotate clockwise to navigate to the next screen, counter-clockwise to return to the previous screen, push
to select menu item.
RS-232 Serial Communication Port
The serial port allows connection and communication between the UPS and an automation or computer system. This allows the installer to program a number of variables including the Critical Load Battery Threshold. See the software documenta­tion for more information.
Status Display
LCD displays status and menu navigation items
Removable Battery Access Panel
Easy to remove for battery access and replacement.
IR Control Section
Indicator LED’s – Indicates status IR Output Jacks – Standard 1/8” (3.5mm) mono jack for connection to an IR flasher (IR flashers not included)
USB to Computer
MB1000 SPECIFICATIONS
Input
Voltage 85 – 137 Vac
Frequency 57 – 63 Hz
AC Power
Current Rating 12 A
Surge Protection 900 Joules
Overvoltage Shutoff, fast rise 150 ± 5 V
Overvoltage Shutoff, slow rise 132 ± 5 V
Undervoltage Shutoff 90 ± 5 V
Automatic Voltage Regulation,
Sensitive Mode Capture Range 98 – 135 V Automatic Voltage Regulation, Sensitive Mode Output Range 120 ± 5% Automatic Voltage Regulation, Standard Mode Capture Range 93 – 145 V Automatic Voltage Regulation, Standard Mode Output Range 120 ± 10% Bank 1 EMI Filtration 66dB Max, 100kHz-2MHz Bank 2 EMI Filtration 66dB Max, 100kHz-2MHz
UPS Output
Voltage 120 ± 5 V Simulated Sine Wave
Frequency 60 Hz ± 1%
UPS Output Capacity 1000VA 600W @ 0.6pf
UPS Backup Time 3 minutes at full load
Transfer Time < 10ms
MB1000 prevents critical equipment from losing setup configuration,
stored data and hard-disk crashes. Shuts off projection equipment
via IR control to allow the projector bulbs to go through a proper
cool-down cycle before shutting off.
WEIGHTS & MEASUREMENTS, QUANTITIES, UPC’S
FOR ORDERING & SHIPPING
SINGLE MODEL MB1000
Dimensions Weight L 17” x H 4” x W 13” 36 lbs.
SINGLE UNIT CARTON
Dimensions Weight UPC L 22.25 x H 9.25” x W 17.5” 40 lbs. 050616-008518
3 Year
Product
Warranty
2 Year Battery
Warranty
MODEL: MB1000
MADE IN CHINA
C US
LISTED
Specifications subject to change due to product upgrades and improvements..
© 2008 Panamax Inc. Panamax and the Panamax logo are registered US trademarks of Panamax.
1690 Corporate Circle, Petaluma, CA. 94954 • 800-472-5555 • 707-283-5900
Fax 707-283-5901 • www.panamax.com
L615 REV. A 12/08
Loading...