Ozito IDP-2000U Original Instructions Manual

ELECTRIC AIR PUMP
130W
ORIGINAL INSTRUCTIONS SPECIFICATIONS
Voltage: 220-240V ~ 50/60Hz Power: 130W Max. Current: 0.62A Max. Pressure: 0.04bar (0.6psi) Flow Rate: 440l/min Max. Run Time: 15min Weight: 0.49kg
IDP-2000U
WHAT’S IN THE BOX
DESCRIPTION OF SYMBOLS
SPARE PARTS
ozito-diy.co.uk
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
• Do not place the hose end against any part of your body when turned on, as this may infuse air into your blood stream putting your health at serious risk.
• Do not make any alterations to this air pump. Only use the adaptors supplied with this product.
• Use this product only in accordance with operation instructions included in this manual.
• It is not suggested that the air pump work continuously for more than 15 minutes. If 15 minutes of use has been reached, turn it off and let it cool for 8 minutes before using again.
• If the pump is making abnormal sounds or its temperature is quite high, turn off the power straight away and let it cool for at least 10 minutes before trying again. Improper use may result in damage of the air pump.
• Do not leave unattended and operating. Keep out of reach of children.
• Put the air pump in a dry place if it is not in use for an extended period of time.
• Keep the air pump away from ammable liquid or gas. Do not allow the
pump to become wet.
• Never put the connector and adaptors into your mouth, ear or eye. They are not
toys.
• Avoid inserting hands into the inlets/outlets of the air pump while it is connected to power.
• Before using the air pump, always inspect it visually. Do not use the pump if it is cracked and/or damaged. If the pump is damaged, contact Ozito customer service.
• Never work or perform maintenance on the pump without rst making sure it has
been disconnected from the mains power.
IMPORTANT:
• The electrical connection must always be made in a dry area. Make sure that electrical connections are protected from inundations.
• Protect the plug and the power cable from heat, oil or sharp edges.
• If damaged, The power cable must be replaced by a qualied electrician.
AIR PUMP SAFETY WARNINGS
WARNING! Read all safety warnings and all instructions. Failure to follow the
warnings and instructions may result in electric shock, re and/or serious injury.
Save all warnings and instructions for future reference. The term “power tool” in the warnings refers to your mains-operated (corded) power tool or battery-operated (cordless) power tool.
1. Work area safety
a. Keep work area clean and well lit. Cluttered or dark areas invite accidents. b.
Do not operate power tools in explosive atmospheres, such as in the presence of ammable
liquids, gases or dust. Power tools create sparks which may ignite the dust or fumes.
c. Keep children and bystanders away while operating a power tool. Distractions can cause
you to lose control.
2. Electrical safety a. Power tool plugs must match the outlet. Never modify the plug in any way.
Do not use any adapter plugs with earthed (grounded) power tools. Unmodied plugs and
matching outlets will reduce risk of electric shock.
b. Avoid body contact with earthed or grounded surfaces, such as pipes, radiators, ranges
and refrigerators. There is an increased risk of electric shock if your body is earthed or grounded.
c. Do not expose power tools to rain or wet conditions. Water entering a power tool will
increase the risk of electric shock.
d. Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the power
tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cords increase the risk of electric shock.
e. When operating a power tool outdoors, use an extension cord suitable for outdoor use.
Use of a cord suitable for outdoor use reduces the risk of electric shock.
f. If operating a power tool in a damp location is unavoidable, use a residual current device
(RCD) protected supply. Use of an RCD reduces the risk of electric shock.
3. Personal safety a. Stay alert, watch what you are doing and use common sense when operating a power
tool. Do not use a power tool while you are tired or under the inuence of drugs, alcohol
or medication.
A moment of inattention while operating power tools may result in serious personal injury.
b. Use personal protective equipment. Always wear eye protection. Protective equipment
such as dust mask, non-skid safety shoes, hard hat, or hearing protection used for appropriate
conditions will reduce personal injuries.
c. Prevent unintentional starting. Ensure the switch is in the off-position before connecting
to power source and/or battery pack, picking up or carrying the tool. Carrying power
tools with your nger on the switch or energising power tools that have the switch on invites
accidents.
d. Remove any adjusting key or wrench before turning the power tool on.
A wrench or a key left attached to a rotating part of the power tool may result in personal injury.
e. Do not overreach. Keep proper footing and balance at all times. This enables better control
of the power tool in unexpected situations.
f. Dress properly. Do not wear loose clothing or jewellery. Keep your hair, clothing and gloves
away from moving parts. Loose clothes, jewellery or long hair can be caught in moving parts.
g. If devices are provided for the connection of dust extraction and collection facilities,
ensure these are connected and properly used. Use of dust collection can reduce dust-
related hazards.
4. Power tool use and care a. Do not force the power tool. Use the correct power tool for your application. The correct
power tool will do the job better and safer at the rate for which it was designed.
b. Do not use the power tool if the switch does not turn it on and off. Any power tool that
cannot be controlled with the switch is dangerous and must be repaired.
c. Disconnect the plug from the power source and/or the battery pack from the power tool
before making any adjustments, changing accessories, or storing power tools. Such preventive safety measures reduce the risk of starting the power tool accidentally.
d. Store idle power tools out of the reach of children and do not allow persons unfamiliar
with the power tool or these instructions to operate the power tool. Power tools are dangerous in the hands of untrained users.
e. Maintain power tools. Check for misalignment or binding of moving parts, breakage of
parts and any other condition that may affect the power tool’s operation. If damaged, have the power tool repaired before use. Many accidents are caused by poorly maintained
power tools.
f. Keep cutting tools sharp and clean. Properly maintained cutting tools with sharp cutting
edges are less likely to bind and are easier to control.
g. Use the power tool, accessories and tool bits etc. in accordance with these instructions,
taking into account the working conditions and the work to be performed. Use of the power tool for operations different from those intended could result in a hazardous situation.
5. Service
a. Have your power tool serviced by a qualied repair person using only identical
replacement parts. This will ensure that the safety of the power tool is maintained.
GENERAL POWER TOOL SAFETY WARNINGS-PERSONAL SAFETY
ELECTRICAL SAFETY
Cleaning
• Keep the ventilation vents of the air pump clean at all times, if possible, prevent foreign matter from entering the vents.
• After each use, blow air through the air pump housing to ensure it is free from all dust particles which may build up. Build up of dust particles may cause the air pump to overheat and fail.
• If the enclosure of the air pump requires cleaning do not use solvents but a moist soft cloth only. Never let any liquid get inside the product; never immerse any part of the air pump into a liquid.
Note: Ozito Industries will not be responsible for any damage or
injuries caused by the repair of the air pump by an unauthorised person
or by mishandling of the product.
Electric Air Pump
3 x Ination Adaptors
Problem Cause Solution
The air pump does not start
Cord not connected to the power
Connect the power cord to a 240V power outlet
On/off switch not in on position
Push the on/off switch into the on position
Adaptors disconnect when the pump switches on
Loose adaptor Ensure the adaptor
is pushed tightly onto the air port
Pump is operating
but the inatable item is not inating/ deating
Some inatable items
have a check valve that require pinching or unscrewing
Pinch or unscrew the items valve while operating the pump
Pump is overheating While inating, the
deation port is being
obstructed, restricting
the ow of the air pump
Ensure the deation
port is free of any obstructions
While deating, the ination port is being
obstructed, restricting
the ow of the air pump
Ensure the ination
port is free of any obstructions
MAINTENANCE
TROUBLESHOOTING
WARNING: BEFORE CLEANING OR CARRYING OUT
ANY MAINTENANCE PROCEDURE, ENSURE THE UNIT IS SWITCHED OFF, DISCONNECTED FROM THE POWER SUPPLY AND ALLOWED TO COOL DOWN.
IMPORTANT: STORE THE AIR PUMP ONLY IN A DRY LOCATION
WHICH IS NOT ACCESSIBLE TO UNAUTHORISED PERSONS.
WARNING! When using mains-powered tools, basic safety precautions, including the
following, should always be followed to reduce risk of re, electric shock, personal injury
and material damage.
Read the whole manual carefully and make sure you know how to switch the tool off in an emergency, before operating the tool. Save these instructions and other documents supplied with this tool for future reference.
Before you connect the equipment to the mains supply make sure that the data on the rating plate are identical to the mains data.
This tool is double insulated therefore no earth wire is required.
The supply cord cannot be replaced. If the cord is damaged the appliance should be scrapped.
Note: Double insulation does not take the place of normal safety precautions when operating this tool. The
insulation system is for added protection against injury resulting from a possible electrical insulation failure
within the tool.
Using an Extension Lead
Always use an approved extension lead suitable for the power input of this tool. Before use, inspect the extension lead for signs of damage, wear and ageing. Replace the extension lead if damaged or defective.
When using an extension lead on a reel, always unwind the lead completely. Use of an extension lead
not suitable for the power input of the tool or which is damaged or defective may result in a risk of re and
electric shock.
WARRANTY
OZITO UK Unit 9 Stadium Court, Wirral International Business Park, Plantation Road, Bromborough, Wirral, CH62 3QG
0916
All of our products undergo strict quality checks to ensure that they reach you in perfect condition. In the unlikely event that your device develops a fault, please contact our service department at the address shown on this guarantee card. You can also contact us by telephone using the customer service number shown. Please note the following terms under which guarantee claims can be made:
1. These warranty terms regulate additional warranty services, which the manufacturer mentioned below promises to buyers of its new products in addition to their statutory guarantee claims are not affected by this guarantee. Our guarantee is free of charge to you.
2. The warranty services only covers defects due to material or manufacturing faults on a product which you have bought from the
manufacturer mentioned below are limited to either the rectication of said
defects on the product or the replacement of the product, whichever we prefer. Please note that our devices are not designed for use in commercial, trade or professional applications. A guarantee contract will not be created if the device has been used by commercial, trade or industrial business or has been exposed to similar stresses during the guarantee period.
3. The following are not covered by our guarantee:
- Damage to the device caused by a failure to follow the assembly instructions or due to incorrect installation, a failure to follow the operating instructions (for example connecting it to an incorrect mains voltage or current type) or a failure to follow the maintenance and safety instructions or by exposing the device to abnormal environmental conditions or by lack of care and maintenance.
- Damage to the device caused by abuse or incorrect use (for example overloading the device or the use or unapproved tools or accessories), ingress of foreign bodies into the device (such as sand, stones or dust, transport damage), the use of force or damage caused by external forces (for example by dropping it).
- Damage to the device or parts of the device caused by normal or natural wear or tear or by normal use of the device.
4. Your Product is guaranteed for a period of 36 months from the original date of purchase and is intended for DIY (Do It Yourself) use only. Lithium Ion batteries and chargers are covered by a 12 month warranty. Warranty excludes consumable parts. Guarantee claims should be submitted before the end of the guarantee period within two weeks of the defect being noticed. No guarantee claims will be accepted after the end of the guarantee period. The original guarantee period remains applicable to the device even if repairs are carried out or parts are replaced. In such cases,
the work performed or parts tted will not result in an extension of the
guarantee period, and no new guarantee will become active for the work performed or parts tted. This also applies if an on-site service is used.
IN ORDER TO MAKE A CLAIM UNDER THIS WARRANTY YOU MUST RETURN THE PRODUCT TO THE PLACE OF PURCHASE WITH YOUR REGISTER RECEIPT.
Please refer to the restrictions of this warranty concerning wearing parts, consumables and missing parts as set out in the service information in these operating instructions.
CUSTOMER SERVICE HELPLINE GB: 0151 294 4488 IRL: 1850 882711 Ozito-diy.co.uk
Spare parts can be ordered from the Special Orders Desk at your local Bunnings Warehouse or Homebase store.
For further information, or any parts visit
www.ozito-diy.co.uk or contact Ozito Customer Service:
Great Britain: 0151 294 4488
Ireland: 1850 882711
E-mail: enquires@ozito-diy.co.uk
A Amps
Double insulated
ONLINE MANUAL
Scan this QR Code with your mobile device to take you to the online manual.
4. DEFLATING ITEMS
2 Insert the adaptor
into the valve of the
inatable item.
4 Once the item is
deated, switch the
air pump off and then remove the adaptor from the valve.
3 Switch the air pump on at the
on/off switch.
1 Fit the required
adaptor onto the
deation port at the
top of the unit tightly.
IMPORTANT: BEFORE CONNECTING OR
DISCONNECTING ACCESSORIES, ALWAYS MAKE SURE THAT THE AIR PUMP IS TURNED OFF.
CAUTION: ENSURE THE INFLATION PORT IS NOT
OBSTRUCTED, OTHERWISE THE UNIT COULD OVERHEAT.
CAUTION: ENSURE THE DEFLATION PORT IS NOT
OBSTRUCTED, OTHERWISE THE UNIT COULD OVERHEAT.
3. INFLATING ITEMS
2 Insert the adaptor
into the valve of the
inatable item.
4 Once the item is
inated, switch the
air pump off and then remove the adaptor from the valve.
3 Switch the air pump on at the
on/off switch.
1 Fit the required adaptor onto
the ination port tightly.
IMPORTANT: BEFORE CONNECTING OR
DISCONNECTING ACCESSORIES, ALWAYS MAKE SURE THAT THE AIR PUMP IS TURNED OFF.
WARNING: AVOID INFLATING THE OBJECTS ABOVE
THE RECOMMENDED INFLATION PRESSURE. THIS MAY LEAD TO DAMAGE AND/OR INJURIES.
2. SWITCHING ON & OFF
WARNING: COMPRESSED AIR CAN BE DANGEROUS.
NEVER POINT THE OUTLET NOZZLE TOWARDS ANY PART OF YOUR BODY OR AT ANOTHER PERSON.
1 Ination Port
2 On/Off Switch
3 Air Pump Housing
4 Deation Port
5 Power Cord
ELECTRIC AIR PUMP
ACCESSORIES
KNOW YOUR PRODUCT
IDP-2000U
1. ADAPTORS
SETUP & PREPARATION OPERATION
6 Ination Adaptors
Fitting an Adaptor
Removing Adaptors
1 Align the required adaptor with
the port.
1 To start operating the air
pump, push the on/off switch to the on position.
2 Push the adaptor
onto the air port tightly.
2 To stop operation,
push the on/off switch to the off position.
1 To remove, simply
pull the adaptor from the air port.
WARNING: ENSURE THE TOOL IS SWITCHED OFF AND
DISCONNECTED FROM THE POWER SUPPLY BEFORE PERFORMING ANY OF THE FOLLOWING STEPS.
162 3 4 5
CAUTION! THE POWER SUPPLY FOR THIS PRODUCT
SHOULD BE PROTECTED BY A RESIDUAL CURRENT DEVICE (RATED AT 30mA OR LESS).
Loading...