Oregon WMR80A User Manual 2

1
EN
Wireless Full Weather Station Kit
Model: WMR80 / WMR80A
USER MANUAL
CONTENTS
Introduction ............................................................... 1
Packaging Contents ................................................. 1
Base station ........................................................... 1
Wind Sensor .......................................................... 1
Temperature & Humidity Sensor ............................ 1
Rain Gauge ............................................................ 2
Accessories - Sensors ............................................. 2
Overview .................................................................... 2
Front View .............................................................. 2
Back View .............................................................. 2
LCD Display ...........................................................2
Wind Sensor ........................................................... 3
Rain Gauge ............................................................ 3
Outdoor Temperature / Humidity Sensor ................ 4
Getting Started .......................................................... 4
4
Set Up Remote Temperature / Humidity Sensor ....
4
Set Up Rain Gauge ................................................
5
Set Up Base Station ............................................... 5
Clock Reception ....................................................... 6
Clock / Calendar ....................................................... 6
Moon Phase .............................................................. 6
Auto Scanning Function .......................................... 6
Weather Forecast ..................................................... 7
Temperature and Humidity ...................................... 7
Temperature and Humidity Trend ........................... 7
Wind Chill / Direction / Speed .................................. 7
UVI / Barometer / Rainfall ......................................... 8
UV Index ................................................................ 8
Barometer .............................................................. 8
Rainfall ...................................................................9
Backlight ................................................................... 9
Reset .......................................................................... 9
Specifications ...........................................................9
Precautions ............................................................. 10
About Oregon Scientific ........................................ 10
EU Declaration of Conformity ............................... 10
FCC Statement ........................................................ 10
INTRODUCTION
Thank you for selecting the Oregon Scientific™ Weather Station (WMR80 / WMR80A).
The base station is compatible with other sensors. To purchase additional sensors, please contact your local retailer.
Sensors with this logo
are compatible with this
unit.
NOTE Please keep this manual handy as you use your new product. It contains practical step-by-step instructions, as well as technical specifications and warnings you should know about.
PACKAGING CONTENTS
BASE STATION
WIND SENSOR
TEMPERATURE & HUMIDITY SENSOR
4 x AA UM-3
1.5V batteries
1 x Wind Sensor (1 x Wind Vane Above
and 1 x Anemometer
Below)
1 x sensor
connector
2 x AA UM-3
1.5V batteries
4 x Screws
(Type A)
1 x Round
U- bolt
2 x AAA UM-4
1.5V battery
1 x wall mount
bracket
1 x Temperature /
Humidity Sensor
1 x Base Station
1 x Table stand
WMR80_IM_EN_R1.indd 1 2008.7.1 7:10:13 PM
2
EN
RAIN GAUGE
ACCESSORIES - SENSORS
This product can work with up to 3 sensors at any one time to capture outdoor temperature, relative humidity or UV readings in various locations.
Optional wireless rem ote sen sor s such as tho se listed below can be purchased separately. For more information, please contact your local retailer.*
• Solar Panel STC800 connectable to Wind Sensor and Temperature / humidity sensor
• Thermo-hygro THGR800 (3-Ch)
• Thermo-hygro THGR810 (10-Ch)
• UV UVN800
* Features and accessories will not be available in all countries.
OVERVIEW
FRONT VIEW
1. + / -: Increase / decrease values of the selected setting; toggle between indoor / outdoor channels
2. LIGHT: Activate backlight
3. MODE: Switch between the different display modes / settings; set clock; set altitude; activate autoscan
2 x AA UM-3
1.5V batteries
4 x Screws
(Type B)
1 x Rain Collector
4. UNIT: Select unit of measurement
5. SELECT: Switch between the different areas
6. MIN / MAX: Read the max / min memory readings;
clear readings
BACK VIEW
1. Wall mount hole
2. RESET: Returns unit to default settings
3. SEARCH: Searches for sensors or for the radio-
controlled clock signal
4. EU / UK: Select the nearest radio signal (WMR80
only)
5. Battery compartment
LCD DISPLAY
1. Outdoor remote sensor battery low
2. Weather Forecast Area
3. Temperature Area
4. Wind Speed / Wind Direction / Wind Chill Area
5. UVI / Barometer / Rainfall Area
6. Clock / Alarm / Calendar
/ Moon Phase Area
7. Humidity / Dew Point Area
6 x Washers
1
2
3
4 5 6
1
2 3 4
5
1
2
3
7
4
5
6
WMR80_IM_EN_R1.indd 2 2008.7.1 7:10:46 PM
3
EN
Temperature Area
1. Selected area icon
2. Indoor / Outdoor channel
temperature and humidity
is displayed
3. Outdoor sensor battery is low
4. Indicate MAX / MIN temperature is displayed
5. Temperature trend
6. Temperature (°C / °F)
Wind Speed / Wind Direction / Wind Chill Area
1. Outdoor wind sensor battery is low
2. Wind speed level indicator
3. Indicate minimum wind chill is displayed
4. Wind speed reading (m / s, kph, mph or knots)
5. Wind speed level description
6. Wind direction display
UVI / Barometer / Rainfall Area
1. In dic ate UV I / baro meter / rai nfa ll re adi ng is displayed
2. Outdoor UV / rain sensor battery is low
3. UVI / barometric pressure (mmHg, inHg or mb) / rainfall readings (in / hr or mm / hr)
4. UVI level indicator
5. Indicate past 24hrs rainfall is displayed
6. Indicate maximum UV is displayed
7. UVI / barometric pressure / rainfall historical bar chart display
Clock / Alarm / Calendar / Moon Phase Area
1. Clock radio reception
2. Indicate time stamp is displayed
3. Time / date / calendar
4. Offset time zone
5. Moon phase
Humidity / Dew Point Area
1. Indicate Dew point level - Temperature is displayed
2. Indicate MAX / MIN humidity / dew point level is displayed
3. Humidity trend
4. Humidity reading
WIND SENSOR
1
2
3
4
1. Wind direction
2. Wind vane casing
3. Anemometer
4. Solar power socket
RAIN GAUGE
Base and funnel:
1. Rain gauge
2. Battery compartment
3. RESET button
1
2
6
5
4
3
1
2 3 4
5 6 7
1
5
4
2
3
1
4
3
2
1
2
3
5
6
4
WMR80_IM_EN_R1.indd 3 2008.7.1 7:11:02 PM
4
EN
1. Funnel
2. Indicator
OUTDOOR TEMPERATURE / HUMIDITY SENSOR
1. LED status indicator
2. RESET hole
3. °C / °F: Select temperature unit
4. CHANNEL switch
5. Battery compartment
GETTING STARTED
SET UP REMOTE WIND SENSOR
The win d sens or takes wind spe ed and directi on readings.
The sensor is bat ter y operated. It is cap able of transmitting data to the base station wirelessly within an approximate operating range of 100 meters (328 feet).
IMPORTANT Ensure that the wind sensor is pointing North to enable it to record accurate readings.
NOTE The sensor should be positioned in an open area away from trees or other obstructions.
To insert batteries:
1
2
1. Unscrew the anemometer from the wind sensor carefully.
2. Insert batteries matching the polarities (+ / -) and replace the anemometer. Press
RESET after each
battery change.
3. Secure the sensor connector in the desired location: a. Align the back of the sensor connector to an
existing pole. Secure in place by inserting the ends of the U-bolt into the holes on the sensor connector
and securing it with washers and bolts. OR b. Insert 4 type A screws into the holes of the sensor
connector. Screw fi rmly into place, i.e., fence.
4. Slide wind vane onto the smaller end of the sensor connector.
NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing.
SET UP REMOTE TEMPERATURE / HUMIDITY SENSOR
The remote sensor can collect data from up to 3 channels.
To set up the remote sensor:
1. Slide open the battery door.
2. Slide channel switch to select a channel (1, 2, 3). Ensure you use a different channel for each sensor.
3. Insert the batteries, matching the polarities (+ / -).
4. Press
RESET after each battery change.
5. Close the battery door.
NOTE Install batteries in the remote sensor before the base station matching the polarities (+ and -).
6. Initiate a sensor search on the base station to start receiving temperature / humidity data from the sensor.
1
5
2
3
4
C F
a
b
WMR80_IM_EN_R1.indd 4 2008.7.1 7:11:10 PM
Loading...
+ 9 hidden pages