Oregon WMR100NA User Manual

Page 1
1
EN
Advanced Weather Station with Wireless
Sensor Set & Mounting Package
Model: WMR100N / WMR100NA
USER MANUAL
CONTENTS
Alternative Set Up: Remote Wind Sensor on Existing Pole
.......................................................... 6
Alternative Set Up: Temperature / Humidity Sensor Mounted Separately
................................... 7
Temperature and Humidity .................................... 10
Temperature and Humidity Trend ......................... 10
Comfort Level ....................................................... 10
Wind Direction / Speed .......................................... 10
UVI / Barometer / Rainfall ....................................... 11
UV Index .............................................................. 11
Barometer ............................................................ 12
Rainfall .................................................................12
Weather Alarms ......................................................12
Set Up Software (First time use) ...........................12
Additional step for Windows Vista users only ...... 12
Install software .....................................................
13
Disable Sleep Mode ................................................ 13
To disable sleep mode on computer ....................
13 (Windows XP)
To disable sleep mode on computer .................... 13
(Windows Vista)
Upload data to PC software ................................... 13
Backlight ................................................................. 14
Reset ........................................................................ 14
Specifications .........................................................14
Precautions ............................................................. 15
About Oregon Scientific ........................................ 15
EU Declaration of Conformity ............................... 15
FCC Statement ........................................................ 16
INTRODUCTION
Thank you for selecting the Oregon Scientific™ Weather Station (WMR100N / WMR100NA).
The base station is compatible with other sensors. To purchase additional sensors, please contact your local retailer.
Sensors with this logo
are compatible with this
unit.
NOTE Please keep this manual handy as you use your new product. It contains practical step-by-step instructions, as well as technical specifications and warnings you should know about.
PACKAGING CONTENTS
BASE STATION
1 x Base Station
1 x USB cable
1 x 6V adapter
4 x AA UM-3 1.5V
batteries
WIND SENSOR / TEMPERATURE & HUMIDITY SENSOR
1 x Wind
Sensor
(1 x Wind
Vane Above
and 1 x
Anemometer
Below)
1 x Aluminium
pole
2 x AA UM-3
1.5V batteries
2 x AAA UM-4
1.5V batteries
Page 2
2
EN
1 x
Temperature
/ Humidity
Sensor casin
g
1 x Temperature
/ Humidity
Sensor
4 x Screws
(Type
A)
1 x sensor
connector
RAIN GAUGE
1 x Rain
Collector
1 x Filter
4 x Screws
(Type C
)
2 x AA UM-3
1.5V batteries
6 x Washers
ASSEMBLY PARTS
1x Vertical
Attachment
Bracket
1 x Cone-
Shaped End
1 x Horizontal
Attachment
Bracke
t
1 x Bottom
Pole 1 x Mid Pole 1x Top Pole
2 x Round
U- bolts
2 x Rectangular
Base Legs
3 x Eye pins
1 x Versatile Base (Wall or Ground Fixable)
ACCESSORIES - SENSORS
This product can work with up to 10 sensors at any one time to capture outdoor temperature, relative humidity or UV readings in various locations.
Optional wireless rem ote sen sor s such as tho se listed below can be purchased separately. For more information, please contact your local retailer.*
• Solar Panel STC800 connectable to Wind Sensor and Temperature / humidity sensor
• Thermo-hygro THGR800 (3-Ch)
• Thermo-hygro THGR810 (10-Ch)
• UV UVN800
* Features and accessories will not be available in all countries.
OVERVIEW
FRONT VIEW
1 2
3
4
5
1. MEMORY / ON / OFF: Read the max / min memory record; Activate / deactivate alarms
2. ALARM: View and set alar ms for baro met er, temperature, humidity, rainfall and wind speed
3. MODE: Switch between the different display modes / settings
4. Rotating dial: Rotate left or right to increase or decrease the values of the selected reading
5. SELECT: Switch between the different areas
Page 3
3
EN
BACK VIEW
1
3
2
4 5
6
7
1. AC adapter socket
2. RESET: Returns unit to default settings
3. SEARCH: Searches for sensors or for the radio­controlled clock signal
4. UNIT: Selects unit of measurement
5. Battery compartment
6. WMR100N only –
EU / UK radio signal
7. USB connector
LCD DISPLAY
1
2
3
4
5
6
7
8
1. Weather Forecast Area
2. Temperature / Heat Index / Wind Chill Area
3. Wind Speed / Wind Direction Area
4. UVI / Barometer / Rainfall Area
5. Clock / Alarm / Calendar
/ Moon Phase Area
6. AC adapter icon - displays when unplugged
7. Low battery icon for base station
8. Humidity / Dew Point Area
Temperature / Heat Index / Wind Chill Area
1 2
3 4
5
6 7
8 9
1. Temperature trend
2. Wind Chill level - temperature is showing
3. Heat Index level - temperature is showing
4. HI / LO temperature, HI Heat Index and LO Wind Chill alarms are set
5. Selected area icon
6. Indoor / Outdoor channel
temperature and humidity
is displayed
7. MAX / MIN temperature
8. Outdoor sensor battery is low
9. Temperature (°C / °F)
Wind Speed / Wind Direction Area
1
2
3
4 5
6
7
1. Wind speed levels: AVERAGE / MAX / GUST
2. Wind speed level indicator
3. Outdoor wind sensor battery is low
4. Wind speed level description
5. Gust wind or wind speed reading (m / s, kph, mph or knots)
6. HI gust wind alarm is set
7. Wind direction display
UVI / Barometer / Rainfall Area
1
2
3 4
7 8 9
5
6
10
1. UVI / barometer / rainfall readings is showing
2. Outdoor UV / rain sensor battery is low
3. UV / barometer / rainfall alarm is set
Page 4
4
EN
4. Rain rate is showing
5. UVI / barometric pressure (mmHg, inHg or mb / hPa)/ rainfall readings (in / hr or mm / hr)
6. UVI level indicator
7. Accumulated rainfall is showing
8. Past 24hrs rainfall is showing
9. Altitude is showing
10. UVI / barometric pressure / rainfall historical bar chart display
Clock / Alarm / Calendar / Moon Phase Area
1 2
3
4
5
6
1. Clock radio reception
2. Alarm 1 and 2 are displayed and set
3. Timestamp is displayed
4. Offset time zone
5. Moon phase
6. Time / date / calendar
Humidity / Dew Point Area
1 2
3 4
5
6
1. Dew point level - Temperature is showing
2. HI / LO humidity and Dew Point alarms are set
3. Comfort levels
4. Humidity trend
5. MAX / MIN humidity
6. Humidity reading
WIND SENSOR
2
3
4
1
1. Wind direction
2. Wind vane casing
3. Anemometer
4. Solar power socket
RAIN GAUGE
Base and funnel:
1
2
3
1. Rain gauge
2. Battery compartment
3. RESET button
1
2
1. Funnel
2. Indicator
Page 5
5
EN
OUTDOOR TEMPERATURE / HUMIDITY SENSOR
1
2
3
4
1. Temperature / humidity sensor casing
2. Solar power socket
3. RESET button
4. Battery compartment
GETTING STARTED
SET UP REMOTE WIND SENSOR
The win d sens or takes wind spe ed and directi on readings.
The sensor is bat ter y operated. It is cap able of transmitting data to the base station wirelessly within an approximate operating range of 100 meters (328 feet).
IMPORTANT Ensure that the wind sensor is pointing North to enable it to record accurate readings.
NOTE The sensor should be positioned in an open area away from trees or other obstructions.
To insert batteries:
1
2
1. Unscrew the anemometer from the wind sensor carefully.
2. Insert batteries matching the polarities (+ / -) and replace the anemometer. Press
RESET after each
battery change.
3
3. Slide wind vane onto the end of the plastic attachment located on the aluminium pole.
NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing.
SET UP REMOTE TEMPERATURE / HUMIDITY SENSOR
1
2
3
1. Holding sensor, twist and click to the left.
2. Pull sensor away from casing.
3. Insert batteries matching the polarities (+ / -). Press RESET after each battery change.
4
5
4. Insert sensor into the casing, twist and click to the right to secure.
5. Slide temperature and humidity sensor onto the smaller end of the sensor connector.
REMOTE UNIT ASSEMBLY
1
3
4
2
1. Insert the cone-shaped end into the pole.
2. Using 2 screws, fix it firmly into place.
Page 6
6
EN
3. Insert the versatile plastic base into the pole. Align the holes of the pole with the holes of the plastic base.
4. Secure the plastic base by inserting the screw and screwing it tightly into the holes of the plastic base and pole.
IMPORTANT The sensor should be positioned in an open area away from trees or other obstructions.
5. Hammer pole (cone end down) into the ground at the desired spot until versatile plastic base is level with the ground.
TIP Place a block of wood between the pole and the hammer to prevent damage to the pole.
6
7
8
9
6. Assemble middle pole on top of the bottom one.
7. Using two screws, fix it firmly into place.
8. Assemble top pole on top of the middle one.
9. Using two screws, fix it firmly into place.
11
10
10. Slide the vertical attachment bracket on top of the top pole.
11. Using two screws, fix it firmly into place.
To mount the temperature / humidity sensor:
12
12. Slid e outdoor sen sor onto ver tical atta chment bracket.
To mount the wind sensor:
13
14
13. Insert the wind vane into the attachment bracket.
14. Screw aluminium pole firmly into place.
IMPORTANT For best results, point the wind vane North.
Securing the assembled remote unit:
16
15
15. Insert the 2 rectangular base legs through the holes of the versatile base and hammer down.
16. Using the string, tie a knot on the eye pins. Hammer each eye pin into the ground at a 90° angle.
IMPORTANT Using the fasteners, tighten the string. To tighten, pull fastener down. To loosen, thread the string up through the fastener eyelets.
ALTERNATIVE SET UP: REMOTE WIND SENSOR ON EXISTING POLE
1
2
3
1. Secure the plastic base onto existing pole with U­bolts, washers and bolts.
2. Insert the horizontal attachment bracket into the base.
3. Using a screw, fix firmly into place.
Page 7
7
EN
16
4
5
6
4. Insert wind sensor into the top of the bracket.
5. Using screws, fix aluminium pole firmly into place.
6. S
lide outdoor sensor onto bracket.
IMPORTANT For best results, point the wind vane North.
ALTERNATIVE SET UP: TEMPERATURE / HUMIDITY SENSOR MOUNTED SEPARATELY
1. Insert 4 type A screws into the holes of the sensor connector. Screw firmly into place, i.e., fence.
SET UP RAIN GAUGE
The rain gauge collects rain and takes readings of rainfall rate and the total rainfall over a period of time. The sensor can remotely transmit data to the base station.
The base station and rain gauge should be positioned within an effective range: about 100 meters (328 feet) in an open area.
The rain gauge should be mounted horizontally about 1 meter (3 feet) from the ground in an open area away from trees or other obstructions to allow rain to fall naturally for an accurate reading.
To set up the Rain Gauge:
2
1
1. Remove screws and slide the cover off in an upwards motion.
2. Insert the batteries (2 x UM-3 / AA), matching the polarities (+ / -). Press
RESET after each battery
change.
3
3. Remove the fibre tape.
To ensure a level plane:
Put a few drops of water on the cross at the base of the funnel to check the horizontal level.
1
23
4
Water will pool to the center of the cross when the rain gauge is level.
If water remains on 1-4, the gauge is not horizontal.
If necessary, adjust the level using the screw.
NOTE For best results, ensure the base is horizontal to allow maximum drainage of any collected rain.
Page 8
8
EN
SET UP BASE STATION
NOTE Install batteries in the remote sensor before the
base station matching the polarities (+ and -).
For continuous use, please install the AC adapter. The batteries are for back-up use only.
NOTE Make sure the adapter is not obstructed and is easily accessible to the unit.
NOTE The base station and adapter should not be exposed to wet conditions. No objects filled with liquid, such as vases, should be placed on the base station and adapter.
Install the base station batteries (4 x UM-3 / AA) matching the polarity + and -. Press RESET after each battery
change.
NOTE Do not use rechargea ble batter ies . It is
recommended that you use alkaline batteries with this product for longer performance.
NOTE Batteries should not be exposed to excessive heat such as sunshine or fire.
The battery icon indicator
may appear in the
following areas:
AREA MEANING
Weather Forecast Area
Battery in the base station is low.
will show when AC
adapter is disconnected
.
Temperature / Heat Index / Wind Chill Area
The displayed channel indicates the outdoor sensor for which battery is low.
Wind Speed / Wind Direction Area
Battery in the wind sensor is low.
UVI / Barometer / Rainfall Area
Battery in the UV / Rain sensor is low.
BASE STATION
CHANGE DISPLAY / SETTING
To change the display and settings, use the following buttons on the rotating dial: SELECT, MEMORY /
ON / OFF, MODE and ALARM.
In addition, the UNIT and SEARCH buttons located at the bottom of the base station allows pre-setting of the remote sensor channels and the measurement units for display.
TIP To exit from the setting mode, push any button. Alternatively, the base station will automatically exit after 30 seconds.
CLOCK RECEPTION
This product is designed to synchronize its calendar clock automatically once it is brought within range of a radio signal:
WMR100N:
• EU: DCF-77 signal: within 1500 km (932 miles) of Frankfurt, Germany.
• UK: MSF-60 signal: within 1500 km (932 miles) of Anthorn, England.
WMR100NA:
• WWVB-60 signal: within 3200km (2000 miles) of Fort Collins Colorado.
WMR100N only - slide the EU / UK swit ch to the appropriate setting based on your location. Press RESET whenever you change the selected setting.
The reception icon will blink when it is searching for a signal. If the radio signal is weak it can take up to 24 hours to get a valid signal reception.
indicates the status of the clock reception signal.
ICON MEANING
Time is synchronized. Receiving signal is strong
Time is not synchronized. Receiving signal is weak
To enable (and force a signal search) / disable the clock radio reception (clock synchronization):
1. Press
SELECT to navigate to the Clock / Calendar /
Alarm Area. will show next to the Area.
2. Press and hold SEARCH.
appears when it is enabled.
Page 9
9
EN
NOTE For best reception, the base station should be
placed on a flat, non-metallic surface near a window in an upper floor of your home. The antenna should be placed away from electrical appliances and not be moved around when searching for a signal.
CLOCK / CALENDAR
To manually set the clock:
(You only need to set the clock and calendar if you have disabled the clock radio reception).
1. Press
SELECT to navigate to the Clock Area. will
show next to the Area.
2. Press and hold
MODE to change the clock setting.
The setting will blink.
3. Rotate the dial left or right to decrease or increase the setting value.
4. Press
MODE to confirm.
5. Repeat steps 1 to 5 to set the time zone offset hour (+ / -23 hours), 12 / 24 hour format, hour, minute, year, date / month format, month, date and weekday language.
NOTE If you enter +1 in the time zone setting, this will give you your regional time plus 1 hour.
If you are in the US (WMR100NA only) set the clock to:
0 for Pacific time +1 for Mountain time
+2 for Central time +3 for Eastern time.
NOTE The weekday is available in English, German, French, Italian or Spanish.
To change the clock display:
1. Press
SELECT to navigate to the Clock Area. will
show next to the Area.
2. Press
MODE to toggle between:
• Clock with Seconds
• Clock with Weekday
• Calendar
CLOCK ALARM
The clock has 2 alarms that can be set to sound with a beep.
ICON MEANING
Alarm 1 or 2 is displayed
Alarm 1 or 2 is activated
No icons No alarm is set
To set an alarm:
1. Press
SELECT to navigate to the Clock Area. will
show next to the Area.
2. Press
ALARM to toggle between alarm 1 and
alarm 2 display.
3. When you’ve selected the alarm you wish to change, press and hold ALARM. The alarm setting will blink.
4. Rotate the dial left or right to change the setting.
5. Press
ALARM to confirm.
To activate / deactivate an alarm:
1. Press SELECT to navigate to the Clock Area. will show next to the Area.
2. Press
ALARM to toggle between alarm 1 and
alarm 2 .
3. Pre ss MEMO RY /
ON / OFF to activate or deactivate the alarm. or appears when the alarm is activated.
MOON PHASE
The Calendar must be set for this feature to work (see Clock / Calendar section).
New Moon Full Moon
Waxing Crescent
Waning Gibbous
First quarter
Third quarter
Waxing Gibbous
Waning Crescent
AUTO SCANNING FUNCTION
To activate the outdoor temperature and humidity auto-scan function:
1. Press SELECT to navigate to the Temperature or Humidity Area. will show next to the Area.
2. Press and hold MODE to activate auto-scan. The temperature and humidity display will scroll from indoor to ch1 through to ch10.
3. Press MEMORY / ON / OFF or MODE or ALARM to stop the auto-scan.
NOTE Channel 1 is used for the outdoor temperature and humidity sensor. Additional temperature and humidity sensors can use other channels.
WEATHER FORECAST
This product forecasts the next 12 to 24 hours of weather within a 30-50 km (19-31 mile) radius.
Weather Forecast Area
ICON DESCRIPTION
Sunny
Partly cloudy
Cloudy
Rainy
Snowy
Page 10
10
EN
TEMPERATURE AND HUMIDITY
The weather station displays indoor and outdoor readings for:
1. Current, minimum and maximum temperatures and relative humidity.
2. Comfort level indicator and trend line.
3. Heat index, wind chill and dew point level.
The weather station can connect up to 10 remote sensors.
NOTE Channel 1 is dedicated for outdoor temperature and humidity.
shows which remote sensor’s data you are viewing.
appears when indoor data is displayed.
The timestamp records the date and time when storing the temperature and humidity readings in memory.
To select the temperature measurement unit:
Press UNIT (at the bottom of the base station) to select °C / °F.
NOTE The unit of all temperature related displays will
be changed simultaneously.
To view temperature (Current temperature, Heat Index and Wind Chill):
1. Press SELECT to navigate to the Temperature Area.
will show next to the Area.
2. Rotate the dial left or right to select the channel.
3. Press MODE repeatedly to toggle betwe en the different displays.
4. Press MEMORY / ON / OFF to select MAX / MIN display.
NOTE To view wind chill, ensure channel 1 is selected.
To view humidity (Humidity, Dew point):
1. Press
SELECT to navigate to the Humidity Area.
will show next to the Area.
2. Rotate the dial left or right to select the channel.
3. Press MODE repeatedly to toggle betwe en the different displays.
4. Press MEMORY / ON / OFF to select MAX / MIN display.
Data required
Area located
Channels supported
Type of memory
Current Temperature
Temperature
Indoor and 1-10 outdoor
MAX
MIN Heat Index MAX Wind Chill 1 only MIN
Humidity
Humidity
Indoor and 1-10 outdoor
MAX
MIN
Dew Point
MAX
MIN
The timestamp is displayed accordingly in the Clock Area.
To clear the mem ori es and timestamp fo r the temperature, heat index, wind chill, humidity and dew point readings:
In the Temperature or Humidity Area, press and hold
MEMORY / ON / OFF to clear the readings.
To change the high / low temperature, heat index, wind chill, humidity and dew point alarms:
1. In the Temperature or Humidity Area, press ALARM repeatedly to toggle between high / low alarms for temperature, heat index, wind chill, humidity and dew point readings.
2. Press and hold
ALARM to enter the alarm setting.
3. Rotate the dial left or right to set the desired values.
4. Press
ALARM to confirm the setting.
To activate / deactivate the high / low temperature, heat index, wind chill, humidity and dew point alarms:
1. In the Temperature or Humidity Area, press
ALARM
repeatedly to select the desired alarm.
2. Pre ss MEMORY /
ON / OFF to act ivate or
deactivate the alarm.
NOTE The dew point advises at what temperature
condensation will form. The wind chill factor is based on the combined effects of temperature and wind speed.
TEMPERATURE AND HUMIDITY TREND
The trend lines are shown next to the temperature and humidity readings. The trend is shown as follows:
RISING STEADY FALLING
COMFORT LEVEL
The Comfort Zone icon indicates how comfortable the climate is based on current temperature and humidity measurements:
COMFORTABLE NEUTRAL UNCOMFORTABLE
WIND DIRECTION / SPEED
The base station provides wind speed and wind direction information.
To read the wind direction find the compass point the
is pointing to.
The timestamp records the date and time when storing the wind speed readings.
Page 11
11
EN
To select the wind speed unit:
Press UNIT (at the bottom of the base station) to switch between:
Metres per second (m / s)
Kilometers per hour (kph)
Miles per hour (mph)
Knots (knots)
The wind level is shown by a series of icons:
ICON LEVEL DESCRIPTION
N/A <2 mph (<4km/h)
Light 2-8 mph (3~13 km/h)
Moderate 9-25 mph (~14-41 km/h)
Strong 26-54 mph (~42-87 km/h)
Storm >55 mph (>88 km/h)
To display the AVERAGE and GUST wind:
1. Press SELECT to navigate to the Wind Speed and Wind Direction Area. will show next to the Area.
2. Press MODE to toggle between AVERAGE and GUST wind readings.
To display the maximum speed and direction for gust wind:
In the Wind Speed and Wind Direction Area, press MEMORY / ON / OFF to toggle between wind speed
/ MAX GUST wind readings. The timestamp is displayed accordingly in the Clock Area.
To clear the memories and timestamp for the wind readings:
In the Wind Speed and Wind Direction Area, press and hold MEMORY / ON / OFF to clear the readings.
To change the high gust wind speed alarm:
1. In the Wind Speed and Wind Direction Area, press and hold
ALARM to enter the high gust wind alarm
setting.
2. Rotate the dial left or right to set the desired values.
3. Press
ALARM to confirm the settings.
To activate / deactivate the high gust wind speed alarm:
1. In the Wind Speed and Wind Direction Area, press ALARM repeatedly to select the desired alarm.
2. Pre ss MEMORY /
ON / OFF to act ivate or
deactivate the alarm.
UVI / BAROMETER / RAINFALL
The weather station works with one UV sensor and one rain gauge. The station is capable of storing and displaying the hourly history data for the last 10 hours
of UV index, and 24 hours of rainfall and barometric pressure readings.
UVI BAROMETER RAINFALL
The bar chart display shows the current and historical data for the UV index, barometric pressure and rainfall readings.
To view the UV / Barometer / Rainfall readings:
1. Press
SELECT to navigate to the UV / Barometer /
Rainfall Area. will show next to the Area.
2. Press MODE to toggle between UVI / Barometer / Rainfall readings. The corresponding icon will appear:
UVI BAROMETER RAINFALL
3. Rotate the dial left or right to view the historical data for the selected area. The corresponding historical readings are showing.
NOTE The number shown in the HR icon indicates how long ago each measurement was taken (e.g. 2 hours ago, 3 hours ago, etc.).
To select the measurement unit for the barometer or rainfall readings:
In the UV / Barometer / Rainfall Area, press UNIT (at the bottom of the base station) to switch between:
• Barometer: Millimeters of mercury (mmHg), inches of mercury (
inHg), millibars per hectopascal (mb /
hpa).
• Rainfall: Millimeters (mm), inches (in), inches per hour (in / hr) or millimeters per hour (mm / hr).
UV INDEX
The UV index levels are as follows:
UV INDEX DANGER LEVEL ICON
0-2 Low
3-5 Moderate
6-7 High
8-10 Very high
11 and above Extremely high
To change the high UV alarm:
1. In the UV / Barometer / Rainfall Area and UVI reading display. Press and hold
ALARM to enter the high UV
alarm setting.
Page 12
12
EN
2. Rotate the dial left or right to set the desired values.
3. Press
ALARM to confirm the settings.
To activate / deactivate the high UV alarm:
1. In the UV / Barometer / Rainfall Area and UVI reading display, press ALARM repeatedly to select the desired alarm.
2. Pre ss MEMORY / ON / OFF to acti vate or deactivate the alarm.
BAROMETER
To change the barometer alarm:
1. In the UV / Barometer / Rainfall Area and
Barometer reading display, press and hold ALARM to enter the Barometer alarm setting.
2. Rotate the dial left or right to set the desired values.
3. Press
ALARM to confirm the settings.
To activate / deactivate the
barometer alarm:
1. In the UV / Barometer / Rainfall Area and Barometer reading display, press
ALARM repeatedly to select
the desired alarm.
2. Pre ss MEMORY /
ON / OFF to act ivate or
deactivate the alarm.
To set the altitude level com pens ation for the Barometer readings:
1. In the UV / Barometer / Rainfall Area and Barometer reading display. Press and hold
MODE to enter the
altitude setting.
2. Rotate the dial left or right to set the desired values.
3. Press
MODE to confirm the setting.
RAINFALL
To view the current hour, accumulated or last 24 hours rainfall history:
In the UV / Barometer / Rainfall Area and Rainfall reading display, press
MEMORY / ON / OFF repeatedly to toggle between current, past 24 hours or accumulated rainfall. The clock line will change to display the start time when the accumulated rainfall is displayed. The icon
appears and the start date is showing.
To toggle between rainfall & rain rate display:
In the UV / Barometer / Rainfall Area and Rainfall reading display, press and hold
MODE.
To reset the accumulated rainfall and timestamp:
In the UV / Barometer / Rainfall Area and Rainfall reading display
. Press and hold MEMORY / ON / OFF to reset the accumulated rainfall to ‘0’ and to set the timestamp to current date and time.
To change the HI rainfall rate alarm:
1. In the UV / Barometer / Rainfall Area and Rainfall
reading display, press and hold
ALARM to enter the
Rainfall alarm setting.
2. Rotate the dial left or right to set the desired values.
3. Press ALARM to confirm the settings.
To activate / deactivate the HI rainfall rate
alarm:
1. In the UV / Barometer / Rainfall Area and Rainfall reading display, press
ALARM repeatedly to select
the desired alarm.
2. Pre ss MEMORY / ON / OFF to acti vate or deactivate the alarm.
WEATHER ALARMS
Weather alarms are used to alert you of certain weather conditions. Once activated, the alarm will go off when a certain criterion is met.
Alarms can be set for:
• Indoor and outdoor high / low temperatures, dew point and High / Low humidity
• High Heat Index
• High Gust Wind
• Low wind chill
• High UV
• Pressure drop
• High rain rate
See the relevant section for how to set the alarm.
To silence any alarm: Press any button or rotate the dial.
SET UP SOFTWARE (FIRST TIME USE)
The base station is capable of connecting to a PC computer using the USB connection. The software can read the latest weather data collected from the base station.
PC system requirements
The mini mum syst em requirements for use of the software is:
• Operating system: Microsoft Windows XP SP2 or Vista
• Processor: Pentium 4 or above
• RAM: Min. 512MB
• Hard disk free space: Min. 512MB
• S c re en D is pla y A re a: 102 4 x 7 68 p ixe l s (recommended)
ADDITIONAL STEP FOR WINDOWS VISTA USERS ONLY
* For Windows XP users, please go straight to Install Software section.
IMPORTANT You must follow the below instructions before installing software.
Determine status of UAC (User Account Control):
1. Click on
Start.
2. In context menu, scroll to Settings and select Control Panel.
3. Doubl e click the User Account (an d Fam ily Safety).
Page 13
13
EN
4. Double click on Change your Windows password. (If you chose the Control Panel classic link from left hand column in step 2, skip this step).
5. In Turn User Account On or Off screen, identify if UAC option is enabled / on (ticked) or disabled / off (un-ticked).
NOTE We highly recommend disabling this option for seamless operation of the Weather OS software.
To Turn User Account Off:
6. Deselect the UAC option by un-ticking the box (click once).
7. Click OK.
8. In You must restart your computer dialogue box, click Restart now.
INSTALL SOFTWARE
1. Insert provided CD into disk drive.
2. Run CD software.
3. Setup Wizard dialogue box will appear and guide you through the installation process.
If you have Windows Vista and User Account Control
is ON (ticked),
i. In Select Installation Folder dialogue box, next
to Folder text box (C:\Program Files \Orego n Scientific\Weather OS), click
Browse.
ii. To select a new location to save the program,
select C:\Users\ adm in. {Or cli ck C: Drive, subfolder Users, subfolder admin.}
iii. Click on
(Create New Folder) icon.
iv. Type
OS Weather and click OK.
v. In User Account Control dialogue box, click
Allow.
vi. Continue with installation process.
4. Du ring in st all at io n, M ic ro so ft V is ua l C+ + Redistributable Setup dialogue box may appear. Select Repair and click Next.
5. Once Setup has been successfully completed, click Finish, then Close.
6. After successful installation, double click on desktop shortcut.
7. Click Display in Oregon Weather Station dialogue box.
DISABLE SLEEP MODE
To allow for continuous data updates, ensure Sleep Mode on computer is disabled.
TO DISABLE SLEEP MODE ON COMPUTER (WINDOWS XP)
1. Right click on Desktop.
2. In context menu, click on Properties.
3. Click on Screen Saver tab in the Display Properties dialogue box.
4. Click on
Power located at the bottom half of dialogue
box.
5. In new dialogue box Power Options Properties, click on Power Schemes tab.
6. In Settings for Timers off (Presentation) power scheme section, under System Standby option, choose Never in drop-down list.
7. Click
Apply and then click OK.
8. Previous window will return. Click OK to confirm and exit.
TO DISABLE SLEEP MODE ON COMPUTER (WINDOWS VISTA)
1. Right click on Desktop.
2. In context menu, click on Personalize.
3. Clic k on Screen Saver link
in the Person alize
appearance and sounds dialogue box.
4. Click on Change Power Settings located at the bottom half of window.
5. Select High Performance and click Change plan settings link.
6. Click
Change advanced power settings link.
7. Click on
next to Sleep, in sub menu, click on
next to Hibernate after.
8. Click Setting link and select Never in drop-down list.
9. Click
Apply and then OK.
UPLOAD DATA TO PC SOFTWARE
NOTE The USB is only used for uploading weather data.
It cannot be used for charging battery power.
1. After successful installation, double click on desktop shortcut.
2. Click
Display in Oregon Weather Station dialogue
box.
3. You will be prompted to select model number. Please select your model in the drop-down list and refer to the image next to your selection to confirm it is the correct model.
4. Plug one end of the USB cable into the base station’s USB port and the other end into the PC’s USB port.
5. Uploading will start immediately.
NOTE This product should be supplied by an identical USB port complying with the requirements of Limited Power Source.
To learn more about how to utilize the functions available on the software, please refer to PC Software Manual,
Page 14
14
EN
downloadable from the software webpage.
IMPORTANT You must first successfully install software to access the PC Software Manual.
1. In the PC software home page, clic k on MENU located at the top right hand corner of software main webpage.
2. Select HELP from drop-down list. This will redirect you to a new webpage. Click on
PC Software
Manual.
SOFTWARE UPDATES
As we continually strive for improvement, the software will be updated from time to time.
If there is a new version, the moment PC is connected to the internet, a dialogue box informing of available software will appear.
1. Click
OK.
2. After a few moments, File Download - Security Warning dialogue box will appear. Click Run.
3. In the Internet Explorer - Security Warning, click Run.
4. Follow steps 3 - 7 from
Install Software section.
BACKLIGHT
Press any butto n or rotate the dial to activ ate the backlight.
RESET
Press RESET to return to the default settings.
SPECIFICATIONS
BASE STATION
Dimensions 143 x 89 x 165 mm
(L x W x H)
(5.6 x 3.5 x 6.5 inches)
Weight
300 g (10.58 oz) without battery
INDOOR BAROMETER
Barometer unit mb/hPa, inHg and mmHg
Measuring range 700 – 1050mb/hPa
Accuracy +/- 10 mb/hPa
Resolution 1mb (0.0 inHg)
Altitude setting Sea level
User setting for compensation
Weather display
Sunny, Partly Cloudy, Cloudy, Rainy and Snowy
Memory Historical data and bar chart
for last 24hrs
INDOOR TEMPERATURE
Temp. unit °C / °F
Displayed range 0°C to 50°C (32°F to 122°F)
Operating range -30°C to 60°C (-4°F to 140°F)
Accuracy 0°C - 40°C: +/- 1°C (+/- 2.0°F)
40
°C - 50°C: +/- 2°C (+/- 4.0°F)
Comfort 20°C to 25°C (68°F to 77°F)
Memory Current, Min and Max temp.
Dew Point w/ Min and Max
Alarm Hi / Lo
INDOOR RELATIVE HUMIDITY
Displayed range 2% to 98%
Operating range 25% to 90%
Resolution 1%
Accuracy 25% - 40%: +/- 7%
40% - 80%: +/- 5%
80% - 90%: +/- 7%
Comfort 40% to 70%
Memory Current, Min and Max
Alarm Hi / Lo
RADIO-CONTROLLED / ATOMIC CLOCK
Synchronization Auto or disabled
Clock display HH:MM:SS
Hour format 12hr AM/PM or24hr
Calendar DD/MM or MM/DD
Weekday in 5 (E, G, F, I, S)
languages
Battery 4 x UM-3 (AA) 1.5V batteries
AC adapter 6V
REMOTE WIND SENSOR UNIT
Dimensions 178 x 76 x 214 mm
(L x W x H)
(7 x 3 x 8.4 inches)
Weight 100 g (3.53 oz) without battery
Wind speed unit m/s, kph, mph, knots
Speed accuracy 2 m/s ~ 10 m/s (+/- 3 m/s)
10 m/s ~ 56 m/s (+/- 10%)
Direction accuracy 16 positions
Transmission of
Approx. every 14 seconds
wind speed signal
Memory Max speed gust
Battery 2 x UM-3 (AA) 1.5V batteries
OUTDOOR TEMPERATURE / HUMIDITY UNIT
RELATIVE TEMPERATURE
Dimensions 115 x 87 x 118 mm
(L x W x H)
(4.5 x 3.4 x 4.6 inches)
Weight
130 g (4.59 oz) without battery
Temp. unit
°C / °F
Displayed range -50°C to 70°C (-58°F to 158°F)
Page 15
15
EN
Operating range -30°C to 60°C (-4°F to 140°F)
Accuracy -20°C – 0°C: +/- 2°C (+/- 4.0°F)
0°C - 40°C: +/- 1°C (+/- 2.0°F)
40
°C - 50°C: +/- 2°C (+/- 4.0°F)
50
°C - 60°C: +/- 3°C (+/- 6.0°F)
Comfort 20°C to 25°C (68°F to 77°F)
Memory Current, Min and Max temp.
Dew Point w/ Max and Min
Wind chill temp. and min
RELATIVE HUMIDITY
Displayed range 2% to 98%
Operating range 25% to 90%
Resolution 1%
Accuracy 25% - 40%: +/- 7%
40% - 80%: +/- 5%
80% - 90%: +/- 7%
Comfort 40% to 70%
Memory Current, Min and Max
Battery 2 x UM-4 (AAA) 1.5V batteries
RF TRANSMISSION
RF frequency 433MHz
Range Up to 100 meters (328 feet) with
no obstructions
Transmission
Approx. every 60 seconds
No. of Channel 1 for Wind/ Rain/ UV and 10 for
Temp. / Humidity
REMOTE RAIN GAUGE
Dimensions 114 x 114 x 145 mm
(L x W x H) 4.5 x 4.5 x 5.7 inches
Weight
241 g (8.50 oz lbs) without battery
Rainfall unit Mm/hr and in/hr
Range 0 mm/hr – 9999 mm/hr
Resolution 1 mm/hr
Accuracy < 15 mm/hr: +/- 1 mm
15 mm to 9999 mm: +/- 7%
Memory Past 24hrs, hourly and
accumulated
from last memory reset
Battery 2 x UM-3 (AA) 1.5V
PRECAUTIONS
• Do not subject the unit to excessive force, shock, dust, temperature or humidity.
• Do not cover the ventilation holes with any items such as newspapers, curtains etc.
• Do not immerse the unit in water. If you spill liquid
over it, dry it immediately with a soft, lint-free cloth.
• Do not clean the unit with abrasive or corrosive materials.
• Do not tamper with the unit’s internal components. This invalidates the warranty.
• Only use fresh batteries. Do not mix new and old batteries.
• Images shown in this manual may differ from the actual display.
• When disposing of this product, ensure it is collected separately for special treatment
and not as household
waste.
• Placement of this product on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible. Consult the furniture manufacturer's care instructions for information.
• The contents of this manual may not be reproduced without the permission of the manufacturer.
• Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
• Please note that some units are equipped with a battery safety strip. Remove the strip from the battery compartment before first use.
NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice.
NOTE Features and accessories will not be available in all countries. For more information, please contact your local retailer.
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products. If you're in the US and would like to contact our Customer Care department directly, please visit: www2.oregonscientific. com/service/support.asp
Fo r in te rnati on al in qu iries , pl ea se vi si t: ww w2. oregonscientific.com/about/international
.asp
EU DECLARATION OF CONFORMITY
Hereby, Oregon Scientific, declares that this Advanced Weather Station with Wireless Sensor Set & Mounting Pac kage (mod els: WMR100N / WMR 100N A) is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service.
COUNTRIES RTTE APPROVAL COMPLIED
All EU countries, Switzerland
and Norway
CH
N
Page 16
16
EN
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energ y and
, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular ins tall atio n. If this equipment does cause har mful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and
receiver.
Co nn ec t th e equi pm en t into an out le t on a
circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio / TV
technician for help.
DECLARATION OF CONFORMITY
The following information is not to be used as contact for support or sales. Please visit our website at
www2.
oregonscientific.com/service
for all enquiries.
We
Name: Oregon Scientific, Inc. Address: 19861 SW 95th Ave.,Tualatin,
Oregon 97062 USA
Telephone No.:
1-800-853-8883
declare that the product
Product No.: WMR100N / WMR100NA Product Name: Advanced Weather Station
with Wireless Sensor Set & Mounting Package Manufacturer: IDT Technology Limited Address: Block C, 9/F, Kaiser Estate, Phase 1, 41 Man Yue St., Hung Hom, Kowloon, Hong Kong
is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation.
Loading...