Oreck Air User Manual [en, es, fr]

AirInstinct
TM
User’s
Model:
AIR10 9
Air Purier
Important!
Read this manual
carefully, and
keep for future
reference.
Enjoy
Call
Congratulations on your purchase of the Oreck AirInstinctTM air purier. Use this manual to learn the features, operation and maintenance of the Oreck Air Purier.
Welcome to our Call. Click. customer service program. To speak with an Oreck representative call:
USA: 18009893535 Canada: 18886767325
Click
On the web, point and click at: www.oreck.com and click locate a store on the top right.
2
Contenido
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
General Warnings . . . . . . . . . . . . . . . . . . . . . . . ...4
Placement Warnings . . . . . . . . . . . . . . . . . . ...... 5
Features ................................. 6
Operation ................................ 8
Manual Mode . . . . . . . . . . . . . . . . . . . . . . .......9
Automatic (AUTO) Mode . . . . . . . . . . . . . . . . . 9
Cleaning.................................11
Cleaning and Replacement Intervals . . . . . . . . .11
Replacing the lters .......................12
Filter Reset Mode . . . . . . . . . . . . . . . . . . . . . . . . . 13
Cleaning the Air Sensor . . . . . . . . . . . . . . . . . . . . 14
Adjusting the Air Sensor ...................15
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Spanish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
French . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
3
Safety
!
General Warnings
IMPORTANT SAFETY
INSTRUCTIONS
• Do not operate any fan with a damaged cord or plug. Discard fan or return to an authorized service facility for examination and/or repair.
• Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Arrange cord away from trafc area and where it will not be tripped over.
• Only use the air purier as described in this manual. Failure to do so may result in serious injury or death.
• Do not use the air purier with a damaged cord or plug. Doing so may result in electric shock, serious injury or death. Have a qualied service technician replace any damaged cords or plugs.
• Do not handle the unit with wet hands. Doing so may result in electrical shock, serious injury or death. Thoroughly dry your hands before handling any part of the air purier.
CAUTION!
• Hair, loose clothing and body parts may get caught in the machine resulting in injury. Keep hair, loose clothing and body parts away from openings and moving parts.
• Do not unplug by pulling on the cord. Doing so may result in electrical sparks and re. Unplug the unit by grasping, and pulling the plug.
Note: A polarized plug has one rounded prong and one straight prong. The rounded end goes into the longest socket slot.
This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to t in a polarized outlet only one way. If the plug does not t fully in the outlet, reverse the plug. If it still does not t, contact a qualied electrician. Do not attempt to defeat this safety feature.
• Do not use an extension cord.
• Do not place the air purier near sources of heat, such as
stove tops, ovens, radiators or computers.
4
!
• This equipment should be inspected frequently and col-
lected dirt removed from it regularly to prevent excessive accumulation that may result in ashover or a risk of re.
• Unplug or disconnect the appliance from the power supply before servicing.
Placement Warnings
WARNING!
• Do not use the air purier outdoors or on wet surfaces.
Doing so may result in electric shock, serious injury or death. Use only indoors and under dry conditions.
• Do not use the air purier in an enclosed space where
ammable, combustible or explosive gases are present.
• Do not use in an area where toxic vapors, ammable dust
or oxygen tanks are present. Doing so may result in serious injury or death. Check the location and make sure these elements are not present.
• Warning: Product contains chemicals known to the State
of California to cause cancer and birth defects or other reproductive harm.
CAUTION!
• Do not place open ames, including candles, directly in
front of the air purier.
• Keep objects away from the air intake grille.
It is important to consider the following when deciding on
where to locate the air purier:
• Position the air purier on a at, solid, stable surface
Never place the unit on soft surfaces such as a bed or sofa.
• Position the air purier where the dirty air is not drawn across your head or body while sitting or sleeping.
• Position the air purier so the plug on the power cord easily reaches a standard electrical outlet for a
polarized plug.
• Never allow children to insert hand in lighted opening.
READ AND SAVE THESE
INSTRUCTIONS
5
Features
1. Display Panel: Air purier controls and indicator lights.
2. Power Button: Turns the purier On and Off.
3. AUTO On/Off Button: Automatically adjusts the fan based
on the level of particles detected by the air sensor.
4. Mood Button: Turns mood lighting On and Off.
5. Speed Button: Manually sets the fan speed.
6. Speed Indicator Lights: Displays fan speed.
7. Check Filter Light: Indicates the lters may need to be
replaced when lit.
8. Front Grille: Air enters here for the rst stage of cleaning.
9. Mood Light/Air Indicator: Visually displays either a
mood light and either a light purple, magenta, or red light based on the level of particles detected by the Air Sensor.
10. Air Sensor: Measures the level of particles passing
through the sensor.
10
2
3 4 5 6
7
1
9
8
6
12
11. Handle: Use handle to move the purier.
12. Exhaust Grille: Directs the ow of air as it exits the unit.
13. Power Cord: Plug into the outlet to begin use.
14. Pre-lter: Filters large particles such as dust, hair and
lint that passes through the lter.
15. Odor Filter: Reduces odors and VOC’s from the air that
passes through the lter.
16. HEPA Filter: Captures 99.97% of dust, allergens, pet
dander, mold and smoke at .3 microns from the air that passes through the lter.
11
14
13
15
16
7
Operation
1. Place. Locate the air purier on a solid surface. Be sure the grille is not blocked by other objects and there are no candles or ames near the unit.
2. Plug In. Into nearest standard electrical outlet that accepts a polarized plug.
3. Press. The power button to turn the purier On or Off. Press and hold the POWER button approximately two seconds to turn the purier OFF.
4. Select. The desired air cleaning mode (manual or automatic) and the fan speed. The fan speed is controlled manually in manual mode or by the Air Sensor in the automatic mode.
3
2
4
1
8
Manual Mode
A. Press the SPEED button for the desired fan speed: L ow,
Medium, High, Turbo.
B. The indicator lights will show the speed. All three lights
will be illuminated in Turbo Mode.
BA
Automatic (AUTO) Mode
Automatic (AUTO) Mode
Important: The Air Sensor is set to standard sensitivity when shipped from the factory. If you prefer the air purier to adjust its speed more or less frequently, you can set the sensi­tivity of the Air Sensor (see page 15).
A. Press the AUTO On/Off button to set the purier in automatic mode. In automatic mode the air purier will
self-adjust the fan speed.
B. The indicator lights will show the speed.
A
9
B
5. Press the MOOD button if you want the mood lamp On
or Off.
5
The MOOD button also functions as the reset button
when a lter needs to be replaced. The indicator light will come on when a lter needs to be replaced.
10
!
Cleaning
Cleaning and Replacement Intervals
Proper care and cleaning of the air purier is critical to performance. The following chart shows the recommend­ed cleaning intervals and method.
Part Time Method
Cabinet As needed Wipe with damp cloth rst.
If required, follow with mild, non-abrasive cleaner.
Air Inlet and Outlet
Air Sensor Every two
Pre-Filter Two to four
Odor Filter 12 months
HEPA Filter 3 years
Every two months
months
weeks
WARNING!
Cleaning the unit while it is plugged in may result in electric shock, electric spark and serious injury. Unplug the unit before cleaning or maintenance
Brush with soft brush. Exercise caution not to have dust fall inside the purier.
See page 14 for instructions.
Rinse thoroughly in warm water or as needed. Let dry before reinstalling.
*
Replace
*
Replace
*
Filter life will vary by usage and environment.
11
Replacing the Filters
IMPORTANT: Always remove the protective plastic packaging from the lter before installing the lter.
1. Unplug the air purier.
2. Open the Cover by gently pulling from the bottom
corners.
3. Press the two hooks above the Pre-Filter, pull straight out of the Cabinet. Thoroughly rinse the pre-lter and let it air dry before placing it back in the cabinet.
Note: Do not use heated or compressed air as part of the drying process.
4. Remove the used Odor Filter and HEPA lter. Note:
Do not dispose of the odor lter’s plastic frame.
5. Remove the plastic bag from the lters.
6. Place the lters back in the Cabinet in the following
order: HEPA lter, Odor lter, and Pre-Filter.
Note: Insert Odor Filter into its plastic frame before inserting into the unit.
3
2
6
5
12
4
Filter Reset Mode
1. The indicator light will come on when a lter may need
to be replaced.
2. When the indicator light comes on, press the Mood But-
ton to nd out which lter needs to be replaced:
Low Speed Light
Indicates Odor Filter is in need of replacement
Medium Speed Light
Indicates HEPA Filter is in need of replacement
1. After installing a new lter replacement, press and hold the reset (MOOD) button for approximately two seconds to set reset.
Note: If the AUTO button is pressed or twenty seconds
have passed in reset mode, the reset mode is cancelled.
*
2
Press and hold to reset lter
3
1
Forced Reset Mode
When you have replaced a lter before the lter replacement light is illuminated:
1. Press and hold the reset button for 1 second (forced reset).
2. Push the speed button to select the replaced lter. When
both low and medium speed lights are illuminated, replace both lters.
3. To complete forced reset, press and hold the reset button for approximately 1 second.
When the auto button is pressed or 20 seconds have passed in the forced reset mode, the forced rest mode is cancelled.
*
Filter life will vary by usage and environment.
13
Cleaning the Air Sensor
!
WARNING!
Cleaning the unit while it is plugged in may result in electric shock, electric spark and serious injury. Unplug the unit before cleaning or maintenance.
1. Open the air sensor cover on the side of the product.
Clean the air inlet, outlet vents, and air sensor.
2.
Air outlets
Air inlets
3. Wet a cotton swab lightly and clean the lens, dust inlet, and dust outlet. After cleaning, use a dry cotton swab to remove any moisture.
Dust outlet
Dust outlet
Note: Without regular cleaning the sensor will decline in performance.
14
Adjusting the Air Sensor
The purier is shipped with the air sensor set to standard sensitivity. Adjust the sensitivity of the sensor if you want the air purier to adjust its fan setting in Auto Mode to
change more frequently or less frequently.
To adjust the sensitivity of air sensor:
1. Turn the power On.
2. Press the AUTO and SPEED buttons simultaneously for
one second.
3. The speed indicator blinks according to the current
sensitivity of the air sensor.
4. Press the SPEED button for the desired sensitivity.
1
5. Press the AUTO and SPEED buttons simultaneously for
one second to set the sensor.
Note: If ten seconds have passed while in the setting
mode the new setting will automatically be set.
2
4
5
3
Sensitive Standard Insensitive
Speed Low Medium High
15
Service problems that appear to be major can often be solved
Trouble­shooting
easily. You can be your own troubleshooter by reviewing, this guide.
All other servicing should be done by an Oreck authorized service center.
Problem Check Solution
Unit does not turn ON.
• Power Cord
• Cover
• Plug in power cord.
• Make sure that the cover is securely closed.
No air is blowing. • Power Cord
• Is the power On?
Airow speed is weak.
Color of Mood Light is always the same.
Unit does not capture particles.
Unit still does not operate properly.
• Filters • Check the lters. Replace
• Light Purple, Magenta, or Red
• Blue
• Filters • Check the lters. Replace
Review all of the above Contact Oreck for service.
• Plug in power cord.
• Press and hold the POWER button to turn On.
if necessary.
• Were the plastic bags removed from lters?
• Adjust the sensitivity of the
air sensor to insensitive or standard.
• Adjust the sensitivity of the
air sensor to sensitive or standard.
if necessary.
• Unit may be damaged
Contact Oreck for service.
16
Warranty
ORECK MANUFACTURING COMPANY: (Oreck Manufacturing Company gives you the following limited warranty for this product only if it was originally purchased by you for residential use, not for resale, from Oreck or an Oreck Authorized Retail Dealer.)
Oreck will repair or replace, free of charge, to the original purchaser, any part that is found to be defective in material or workmanship within three (3) years following the date of purchase for all residential models. NOTE: If the unit is used commercially, a one (1) year overall warranty applies.
This limited warranty does not cover the replacement of expendable or consumable parts such as lters, cartridges, and other parts subject to normal wear unless they are defective in material or workmanship.
This limited warranty does not apply to any part subjected to accident, abuse, commercial use, alteration, misuse, damage caused by act of God, the use of voltages other than on the data plate of this product or service of this product by other than Oreck or a participating Factory Authorized Service Center.
Oreck does not authorize any person or representative to assume or grant any other warranty obligation with the sale of this product.
Oreck’s limited warranty is valid only if you retain proof of purchase from Oreck or an Oreck Authorized Retail Dealer for this product. If you purchase this product from any other source, your purchase is “AS IS,” which means Oreck grants you no warranty, and that you, not Oreck, assume the entire risk of the quality and performance of this product, including the entire cost of any necessary servicing or repairs of any defects.
Oreck’s liability for damages to you for any costs whatsoever arising out of this statement of limited warranty shall be limited to the amount paid for this product at the time of original purchase, and Oreck shall not be liable for any direct, indirect, consequential or incidental damages arising out of the use or inability to use this product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
ALL EXPRESS AND IMPLIED WARRANTIES OTHER THAN THE LIMITED WARRANTY SET FORTH ABOVE, FOR THIS PRODUCT, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY DENIED.
If there is an issue with your air purier that you believe is covered by this warranty, contact Oreck customer service at 1-800-989-3535. This warranty gives you specic legal rights, and you may also have other rights which vary from state to state.
17
Loading...
+ 37 hidden pages