![](/html/24/24c3/24c3d14ae8e35cf7f392fbcdeed19f38f3415ca6418ec035762fed7464f18919/bg1.png)
Series
Standby UPS
VS1000C
UPS Series
Line Interactive
Elegant outlook and state of the art design that is compatible with personal computers and home entertainment systems
(i.e. PS/2). Horizontal and vertical design allows you to place it anywhere you like.
UPS and surge protector for both PC and home entertainment systems.
Keep your home gaming system running when a power failure is encountered. VS1000C helps you ensure that
all your data is securely stored.
Backup Time (Typical)
VS1000C 1PC+1LCD 18-35 mins
Series
On Line UPS
VS1000C
*
Front Panel
AVR Series
Inverter Series
Rear Panel
Surge Series
110V / 120V
Series
Green Power
ON / OFF
AC Mode
Backup Mode
Test / Silence
Overload
Battery Fault
Communication
Port
UPS Outlets
Data Line
Protection
Surge Outlets
Fuse
IEC 320 Inlet
Communication
Port
Outlets
Data Line
Protection
Specifications
Model Name VS1000C
Topology
On-battery Output Waveform
OUTPUT
Bypass Capacity
No. of outlets
Voltage (on battery)
Frequency (on battery)
Transfer Time
INPUT
Maximum Capacity
Voltage (range)*
Frequency
PROTECTION
Unit Input
Overload Protection
Short Circuit
BATTERY
Typical Recharge Time (to 90% of full capacity)
Typical Backup
User Replaceable Battery
PHYSICAL
Weight (Net / Gross) (kg) (lbs)
Dimension (Physical / Packing) (in)
(LxWxH) (mm)
WARNING SIGNALS
Communication Port
Audible Alarms
ENVIRONMENT
Ambient Operation
Audible Noise
CONFORMANCE
Approvals
* Models of these nominal voltages are available, however each model is preset to a certain nominal voltage, which is not user-changeable.
Win
windows
95/98
ME/NT
windows
2000 / XP
2003 / Vista
2 Battery backup + 1 Surge (US); 2 Battery backup (220V / 230V / 240V)
230V / 240V +15% / -20% at line input
50 or 60Hz +/- 10% (auto sensing)
Fuse for overload & short circuit protection
UPS automatic shutdown if overload exceeds
105% of nominal for 20 seconds, 120% for 10 seconds, 130% for 3 seconds.
18-35 mins (a PC with 15" LCD)
7.6 x 2.8 x 10.1/ 10.4 x 5.6 x 13.3
194 x 71 x 257 / 263 x 141 x 337
Battery back-up, Battery low, Overload, UPS fault
3,000 meters max. elevation, 5-90% humidity (No-condensing water), 0-40 C
< 40dBA (1 meter from surface)
Standby
Simulated Sine Wave
10A
Rated Voltage
50 or 60Hz +/- 0.4Hz
4 ms (typical)
800VA/480W
110V +/-25% at line input
120V +20% /-25% at line input
220V +/-25% at line input,
UPS output cut off immediately
4 Hours
12V / 34W x 1
3.6 (7.93) / 4.1 (9.03)
USB
CE, UL/cUL, GOST-R
Simulated
Sine Wave
220V / 230V / 240V
Series
Networking
Fuse
IEC 320 Inlet
6.