Connecting your equipment to the UPS
For UPS models with US-type outlets: connect the power cord(s) of your computer
equipment to the output receptacle(s) of the UPS.
For UPS with IEC outlets, as shown in the illustration, u se your computer power cord to
connect UPS to the wall socket. Use the power cord supplied with the UPS to connect
your PC to one of UPS outlets (item 1.5 on the rear panel drawing below).
Thunder Shield
User Manual
Placement
This UPS is intended for indoor use
only; its internal components are not
sealed from the environment.
Please install it in a protected
environment away from excessive heat
or excessive moisture.
Charging the UPS first
The battery is fully charged at the
factory. However, it is recommended to
charge the battery at least 8 (eight)
hours before using the UPS, since
energy loss may have occurred during
shipping or long duration storage. To
recharge the battery, simply leave the
UPS plugged into an AC outlet.
www.opti-ups.com
Turn on the UPS
To turn UPS on please press the power butto n for 3 seconds. Pressing the power button
shortly under normal mode will enable the self-test function. The silence function can be
enabled/disabled by shortly pressing the power button in backup mode. In addition, the
power button can be used as the master on/off switch for your equipment by leaving your
equipment connected to UPS and switched on. To turn off the UPS, please press power
button for about 3 seconds.
Front & Rear Panels
**)
No Load Shutdown Function
As a battery saving feature, the UPS will automatically turn off if none
of the connected equipment is operating while the UPS is in back-up
mode. Once normal utility power returns, the unit will re-start
automatically. You can disable the “No Load Shutdown” function by
pressing the power button of your switched-off UPS until you hear two
beeps.
1.1 Power Button 1.5 UPS Outlets
1.2 RS-232 Port
1.3 Phone/LAN Jack
1.4 AC Input 1.8 AC Fuse
_____________________________________________
*)
TS-B models only
**)
Battery Backup Outlet for TS1700(B) (110V/120V) /
TS2250
*)
110V/120V/220V/230V/240V
1.6 Surge Suppression Outlet
*)
1.7 Circuit Breaker
**)
Front panel LED (UPS status indicator)
When the LED is continuously lit and the
buzzer is silent, the UPS is in normal mode and
AC Mode
Battery Mode
Fault
providing power to your equipment. The UPS
will continue to filter electrical noise and
provide surge protection.
When the LED blinks every 2 seconds in time
with the beeping sound, the UPS is providing
power from its battery.
When the LED is flashing rapidly and the
beeping sound is continuous, it indicates that
the UPS is overloaded.
Warning
DO NOT PLUG LASER PRINTERS INTO THE UPS BECAUSE
THEY TYPICALLY DRAW TOO MUCH POWER
Fuse replacement procedure
(Note: for 220V/230V/240V units only)
1. Use a slotted screwdriver to take out the fuse holder
2. Take out the busted fuse from the fuse holder
3. Use the screwdriver to push out the spare fuse from the holder
4. Put the spare fuse in the holder
5. Push the fuse holder back into the AC input socket
6. Follow the UPS turn on procedure
Battery replacement procedure
Note: Follow this procedure for safe replacement of the battery. Howev er, small sparks may occur
during the process. This is normal.
1. Turn off the UPS and unplug it from the wall outlet
2. Remove two screws both sides nearby the front panel
3. Gently pull the top portion of the front panel until it unsnaps
4. Place the front panel on top of the unit taking care not to pull out the wires for the panel
5. Remove the screw for the battery cover
6. Gently pull out the batteries using the tab located at the base of the battery
7. Disconnect the two long wires connecting the batteries to the UPS
8. Use the short wire to connect between the batteries and push the new batteries into place
9. Connect the long wires to the new batteries, making sure that the red wire is connected to the red
battery terminal of the lower battery and the black wire to the black battery terminal of the upper
battery
10. Mount the battery cover and replace the screw
11. Snap back the front panel into place
12. Follow the UPS turn on procedure
Specifications
Model
Maximum Capacity 600W 900W 1200W
Topology Line-interactive
On-battery Output Waveform Simulated Sine Wave
Input Voltage Range 110/120V or 220/230/240V +/- 25%
Input Frequency 50Hz/60Hz Auto Sensing
Output Voltage Regulation Rated voltage +/- 5%
Communication Port RS232*)
Data Line Surge Protection RJ11/RJ45*)
Surge Energy Rating 480 Joules
Recharge Time to 90% 6 hours
Operating Temperature
Storage Temperature
Relative Humidity 0 to 95% maximum, non-condensing
Audible Noise <40 dBA
Unit Dimensions (L×W×H), mm
Net Weight, kg 13.4 (14.8) 15.9 (17.3)
EMC/RFI Compatibility CE
Safety Certifications CE, UL, cUL
*)
TS-B models only
Thunder Shield 1250(B) Thunder Shield 1700(B) Thunder Shield 2250(B)
0~40°C / 32~104℉
-20~60°C / -4~140℉
382×130×192
Warranty
LIMITED WARRANTY
What the warranty covers:
We guarantee this product to be free from defects in material and workmanship during
the warranty period. If a product proves to be defective in material or workmanship
during the warranty period, we will at our sole option, repair or replace the product
with a like product.
How long the warranty is effective:
For accurate warranty period and conditions, please contact the local branch offices or
your dealers.
Who the warranty protects:
This warranty is valid only for the first consumer purchaser.
What the warranty does not cover:
1. Any product on which the serial number has been defaced, modified or
removed.
2. Damage, deterioration or malfunction resulting from:
a) Accident, misuse, neglect, fire, water, or other acts of nature, unauthorized
product modification, or failure to follow instructions supplied with the
product.
b) Repair or attempted repair by anyone not authorized by OPTI-UPS.
c) The fault is the result of accidental damage or damage in transit or
transportation, including but not limited to liquid spillage.
d) Removal or installation of the product.
e) Causes external to the product.
f) Use of supplies or parts not meeting our specifications.
g) Normal wear and tear.
h) Any other cause which does not relate to a product defect.
3. Removal, installation and set-up service charges.
Limitation of implied warranties:
There are no warranties , expressed or implied, which extend beyond the description
contained herein including the implied warranty of merchantability and fitness for a
particular purpose.
Exclusion of damages:
Our liability is limited to the cost of repair or replacement of the product. We shall not
be liable for:
1. Damage to other property caused by any defects in the product, damages based
upon inconvenience, loss of use of the product, loss of time, loss of profits, loss
of business opportunity, loss of goodwill, loss of data, loss of software, costs of
substitute equipment, interference with business relationships, claims by third
parties, or other commercial loss, even if advised of the possibility of such
damages.
2. Any other damages, whether incidental, consequential or otherwise.
3. Any claim against the customer by any other party.
Troubleshooting
Problems Possible Cause Solution
Press the power switch for more
than 1 second until the UPS
turns on
Recharge the battery for 6 hours
by leaving the UPS plugged in
and the load disconnected from
the UPS.
Disable “No Load Shutdown
Function”
Check input voltage
Recharge the battery for 6
hours. If the problem is still
present, replace the battery.
UPS can’t turn on,
LED does not light
UPS always at battery
mode
Back up time too short
Buzzer continuously
beeping
Power switch not pressed
long enough
Battery voltage is less
than 10V
Load is less than 20W at
battery mode
PCB failure Call for service
Input power cord is loose Plug in the power cord firmly
Busted input fuse Replace the fuse
Input voltage too high or
too low
PCB failure Call for service
Battery is not fully
charged or defective
PCB failure Call for service
Overload Remove some loads
Contact Information
OPTI-UPS USA:
Tel: +1-909-869-5700
Fax: +1-909-869-5730
Toll Free: (888) OPTI-UPS
info@opti-ups.com
http://www.opti-ups.com
OPTI-UPS UK:
Tel: +44 0208 622 3083
Fax: +44 0208 622 3200
info@opti-ups.co.uk
http://www.opti-ups.co.uk
OPTI-UPS Europe:
Tel: +49-89-3715-6 420
Fax: +49-89-37156-4229
info@opti-ups.de
http://www.opti-ups.de
OPTI-UPS Czech:
Tel: +420-604- 444077
Fax: +420-604-444077
info@opti-ups.cz
http://www.opti-ups.cz
OPTI-UPS Australia:
Tel: +61-3-9545-53 22
Fax: +61-3-9545-5669
Toll Free AU: 1800-678-428
info@optiups.com.au
http://www.optiups.com.au
OPTI-UPS Middle East:
Tel: +9714-8819-83 8
Fax: +9714-8819-938
inquiry@opti-ups.com
http://www.opti-ups.com
OPTI-UPS Panama:
Tel: +507-4415668
Fax: +507-4416851
tony@opti-ups.com
http://www.opti-ups.com
OPTI-UPS Asia:
Tel: +886-2-2246-7 272
Fax: +886-2-2246-7312
Toll Free: 0800-029898
info@opti-ups.com.tw
http://www.opti-ups.com.tw