OPTI-UPS AS450, AS450B, AS450C, AS650, AS650B Quick Manual

...
6hours
CAUTION: NEVER connect a laser printer or scanner to the
UPS unit. This may cause the damage of the unit.
1. Package Contents
You should have received the following items inside of package:
- UPS Unit
- Communication cable (only for the model with USB/RS-232 port)
- Power cable (only for the IEC-type model)
2. Product Overview
Front View:
Back View:
NEMA Type IEC Type Schuko Type Universal Type
3. Installation and Initial Startup
NOTE: Before installation, please inspect the unit. Be sure that nothing inside
the package is damaged.
Placement & Storage Conditions
Install the UPS in a protected area that is free of excessive dust and has adequate air flow. Please place the UPS away from other units at least 20 cm to avoid interference. Do NOT operate the UPS where the temperature and humidity is outside the specific limits. (Please check the specs for the limitations.)
Connect to Utility and Charging
Plug in the AC input cord to the wall outlet. For the best results, suggest to charge the battery at least 6 hours before initial use. The unit charges its battery while connecting to the utility.
Connect the Loads
Plug in the loads to output receptacles on the rear panel of the UPS. Simply turn on the power switch of UPS unit, then devices connected to the UPS will be protected by UPS unit.
Connect Modem/Phone/Network for Surge Protection
(Only for the model with
RJ-11/RJ-45)
Connect a single modem/phone line into surge-protected “IN” outlet on the back panel of the UPS unit. Connect from “OUT” outlet to the computer with another phone line cable.
Connect Communication Cable
(Only for the model with USB/RS-232 port)
To allow for unattended UPS shutdown/start-up and status monitoring, connect the communication cable one end to the USB/RS-232 port and the other to the communication port of your PC. With the monitoring software installed, you can schedule UPS shutdown/start-up and monitor UPS status through PC.
Turn On/Off the Unit
Turn on the UPS unit b y pressing the power switch. Turn off the UPS unit by pressing again the power switch.
Active Line Interactive UPS Quick Guide V. 1.1
X
Output receptacles Y
AC input
Z Circuit breaker
[ RS-232 communication port
\ Modem
/p
hone or Network surge protection ] USB communicationport
X
Power Switch
Y
AC mode indicator: green lighting
Z Battery mode indicator: yellow
flashing
[
Fault mode indicator: red lighting
4. Important Safety Warning (SAVE THESE INSTRUCTIONS)
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity
controlled indoor area free of conductive contaminants. (See the specifications for the acceptable temperature and humidity range.) CAUTION! T o reduce the risk of o verheating the UPS, do not co ver the UPS' cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces. CAUTION! Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS.
CAUTION! Do not plug the UPS input into its own output. CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages
or any other liquid-containing vessels on or near the unit. CAUTION! In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS.
CAUTION! Do not attach a power strip or surge suppressor to the UPS. CAUTION! If the UPS is with metal chassis, for safety purpose, grounding is a must during
UPS installation in order to reduce leakage current below 3.5A. Attention hazardous through electric shock. Also with disconnection of this unit from the mains, hazardous voltage still may be accessible through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole at the quick connectors of the battery when maintenance or service work inside the UPS is necessary. CAUTION! Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.
CAUTION! When replacing the batteries, use the same number and type of batteries. CAUTION! Internal battery voltage is 12VDC. Sealed, lead-acid, 6-cell battery. CAUTION! Do not dispose of batteries in a fire. The battery may explode. Do not open or
mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes.
CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent. CAUTION! A battery can present a risk of electric shock and high short circuit current. The
following precaution should be observed before replacing batteries:
1) Remove watches, rings, or other metal objects.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or disconnecting batteries terminal.
5. Software Download & Installation (Only for the model with communication port)
Please follow steps below to download and install monitoring software:
1. Go to the website http://www.power-software-download.com
2. Click ViewPower software icon and then choose your required OS to download the software.
3. Follow the on-screen instructions to install the software.
4. When your computer restarts, the monitoring software will appear as an orange plug icon located in the system tray, near the clock.
6. Trouble Shooting
Use the table below to solve minor problems.
Problem Possible Cause Solutions
Low battery. Charge the UPS at least 6 hours. Battery fault. Replace the battery with the same
type of battery.
No LED display on the front panel.
The UPS is not turned on. Press the power switch again to turn
on the UPS. Alarm continuously sounds when the mains is normal.
The UPS is overload. Remove some loads first. Before
reconnecting equipment, please
verify that the load matches the UPS
capability specified in the specs.
The UPS is overload. Remove some critical load. Battery voltage is too low. Charge the UPS at least 6 hours.
When power fails, back-up time is shorten.
Battery defect. It might be due to high temperature operation environment, or improper operation to battery.
Replace the battery with the same
type of battery.
The mains is normal but yellow LED is flashing.
Power cord is loose. Reconnect the power cord properly.
7 Specifications
Model AS450/AS450B/
AS450C
AS650/AS650B/
AS650C
AS850/AS850B/
AS850C
CAPACITY 450 VA / 240 W 650 VA / 360 W 850 VA /480 W INPUT
Voltage 110/120 VAC or 220/230/240 VAC Voltage Range 81-145 VAC / 162-290 VAC OUTPUT Voltage Regulation +/-10% Transfer Time Typical 4 ms Waveform Simulated Sine Wave BATTERY Type & Number 12 V/4.5 AH x 1 12 V/7 AH x 1 12 V/9 AH x 1 Charging Time < 4 hours recover to 90% capacity PHYSICAL Dimension (DxWxH) 11.29 x 3.93 x 5.59 in / 287 x 100 x 142 mm Net Weight 7.9 lbs / 3.6 kg 9.4 lbs / 4.3 kg 10.9 lbs / 4.9 kg Environment Humidity
0-90 % RH @ 0-40°C / 32~104°F (non-condensing) Noise Level Less than 45 dB MANAGEMENT USB/RS-232 (Option) Windows 98 SE/ME/NT 4.x/2000/2003/XP/Vista/2008