HOBO® RX Wireless Sensor Network
HOBO RX3000 RXW Manager (RXMOD-RXW-xxx) Manual
The HOBO RX3000 RXW Manager is a module and mote designed to work with the HOBOnet
Wireless Sensor Network. When the RXW Manager module is installed in an RX3000 station, data
is transmitted wirelessly from sensor motes across the network to the RX3000 station and then
uploaded to HOBOlink® web-based software. You can use HOBOlink to monitor the network, view
graphs, set up alarms, download data, and more.
Specifications
HOBO RX3000
RXW Manager
Models:
• RXMOD-RXW-900 (US)
• RXMOD-RXW-868 (Europe)
• RXMOD-RXW-922
(Australia/NZ)
Items Included:
• Cable ties
• Screws
Components and Operation
Mounting
Tab
Latch
Eyelet
Cable
Manager Mote Closed Manager Mote Opened
perating Temperature
Range
Radio Power 12.6 mW (+11 dBm) non-adjustable
Transmission Range Reliable connection to 457.2 m (1,500 ft) line of sight at 1.8 m (6 ft) high
Wireless Data Standard IEEE 802.15.4
Radio Operating
Frequencies
Modulation Employed OQPSK (Offset Quadrature Phase Shift Keying)
Data Rate Up to 250 kbps, non-adjustable
Duty Cycle <1%
Maximum Number of
Motes
Power Source Powered by the RX3000 station
Dimensions Mote: 16.2 x 8.59 x 4.14 cm (6.38 x 3.38 x 1.63 inches)
Weight Mote: 159 g (5.62 oz)
Materials Mote: PCPBT, silicone rubber seal
Environmental Rating Mote: IP67, NEMA 6
ompliance Marks RXMOD-RXW-900: See last page
-25° to 60°C (-13° to 140°F)
Reliable connection to 609.6 m (2,000 ft) line of sight at 3 m (10 ft) high
RXMOD-RXW-900: 904–924 MHz
RXMOD-RXW-868: 866.5 MHz
RXMOD-RXW-922: 916–924 MHz
50 motes per one RX Wireless Sensor Network
Cable length: 2 m (6.56 ft)
RXMOD-RXW-868: The CE Marking identifies this product as
complying with all relevant directives in the European Union
(EU).
RXMOD-RXW-922: See last page
The RXW Manager consists of a mote with a cable attached that
Antenna
is plugged into a module, which is installed in the RX3000
station. These are the components of the mote and module.
Mounting Tab: Use the tabs at the top and bottom of the mote
to mount it (see Deploying and Mounting).
Cable: Use this cable to connect the mote to the module.
Eyelet: Use this eyelet to attach a 3/16 inch padlock to the
USB Port
mote for security.
Latch: Use the two latches to open and close the mote door.
Antenna: This is the built-in antenna for the radio
communications across the RX Wireless Sensor Network.
USB Port: Use this port to connect to the mote to a computer
via USB cable if you need to update the firmware (see Updating
Module Jack
Mote Firmware).
Manager Module
22248-A
Module Jack: Use this jack to connect the mote to the module
with the cable attached to the mote (see Installing the Module).
HOBO RX3000 RXW Manager (RXMOD-RXW-xxx) Manual
Installing the Module
The module must be installed in an RX3000 station before the
motes in the RXW Wireless Sensor Network can join the network.
Important: If you have not already registered the RX3000
station with HOBOlink and set up the station communications,
follow the instructions in the RX3000 Quick Start.
To add a module:
1. Stop the station if it is currently logging. Press the Connect
button and wait for the station to connect to HOBOlink so
that all the latest data is offloaded before adding a new
module.
Press Connect if the station was
logging to upload the latest data
2. Once the station is done connecting to HOBOlink, power it
down by disconnecting the battery and unplugging any
charging device.
3. Insert the connector on the back of the module into the
receptacle in the left or right module slot.
module was installed in the left slot in this example, it is
listed on the LCD as module 1.
The module
is added to
D
7. The station should automatically connect to HOBOlink
(press the Connect button on the station if it does not).
Check your station’s page in HOBOlink to make sure the
new module is listed.
8. If you added the module to an RX3000 station that was
previously in use, you will need to update the station
firmware. (If you have a new station, go to the next step.)
To update the firmware:
a. In HOBOlink, go to Devices > List and click your station
name.
b. On the station page, click Overview and scroll down to
Device Information.
c. On the General tab under the Firmware Version, click the
firmware upgrade link.
Insert the connectors
on the module here
4. Using a Phillips-head screwdriver, tighten the screw at the
bottom of the module.
5. Plug the cable from the RXW Manager mote into the jack on
the module, making sure the cable is inserted through the
bottom of the station case. Do not reconnect the power on
the station until the mote is plugged in as shown.
6. Plug in the battery and then the charging device, and wait
for the station to power up. Verify that the new module is
listed on the LCD screen with a checkmark. Because the
Click this link to
upgrade the
station firmware
d. Select Upgrade on Next Connection and click Save.
e. Press the Connect button on the station.
Press Connect to connect to HOBOlink
and start the firmware upgrade
f. Wait for the firmware upgrade to complete. The upgrade
icon should be gone in HOBOlink once the upgrade is
successful. If the station firmware is not successfully
installed, it could be because there is an interruption in
cellular service or poor signal strength. Contact Onset
Technical Support at 1-800-LOGGERS, 508-759-9500, or
www.onsetcomp.com/support/contact for help.
9. Set the logging interval for the module in HOBOlink. Go to
Devices > List, select the icon next to your station, and
select Module/Sensor Configuration. Select Module <1 or
2>: Wireless Sensors Logging, enter a logging interval (how
often the sensor motes will record data), and click Save.
1-800-LOGGERS 2 www.onsetcomp.com