Test Equipment Depot - 800.517.8431 - 5 Commonwealth Ave, MA 01801 - TestEquipmentDepot.com
InTemp® CX400 Series Temperature Logger Manual
InTemp CX400 series loggers measure temperature in indoor monitoring applications. Designed
to meet World Health Organization (WHO) and Centers for Disease Control and Prevention
(CDC) guidelines, this logger is ideal for clinical applications, such as vaccine storage and
pharmaceutical manufacturing. This Bluetooth® Low Energy-enabled logger is designed for
wireless communication with a mobile device. Using the InTemp app, you can easily configure
the logger with one of four preset profiles designed for ambient storage, clinical refrigerator,
freezer, or refrigerator monitoring or you can set up a custom profile for other applications.
You can also quickly perform daily logger checks, download reports, and monitor tripped
alarms. Or, you can use InTempConnect® to configure and download CX series loggers via the
CX5000 Gateway. The InTempVerify™ app is also available to easily download loggers and
automatically upload reports to InTempConnect. Use the built-in LCD screen on the logger to
check the current temperature, daily maximum or minimum temperatures, logging status,
battery use, and more. Once data is uploaded to InTempConnect, you can track logger
configurations and automatically upload logger data to build custom reports for further
analysis. The CX402 model uses a 2- or 4-meter probe and is available with a 5, 15, or 30 mL
glycol bottle (bottle holder included). It also contains an internal sensor for ambient
InTemp CX400 Temperature
Loggers
temperature monitoring. The CX403 model is available with an internal sensor only.
Specifications
Models:
• CX402-T205 & CX402-VFC205,
2 meter probe and 5 mL glycol
bottle
• CX402-T215 & CX402-VFC215,
2 meter probe and 15 mL
glycol bottle
• CX402-T230 & CX402-VFC230,
2 meter probe and 30 mL
glycol bottle
• CX402-T405 & CX402-VFC405,
4 meter probe and 5 mL glycol
bottle
• CX402-T415 & CX402-VFC415,
4 meter probe and 15 mL
glycol bottle
• CX402-T430 & CX402-VFC430
4 meter probe and 30 mL
glycol bottle
• CX402-T2M, CX402-B2M, &
CX402-VFC2M, 2 meter probe
• CX402-T4M, CX402-B4M, &
CX402-VFC4M, 4 meter probe
• CX403
Included Items:
• Double-sided tape (for models
with glycol bottles)
• Two AAA 1.5 V alkaline
batteries
• Battery door and screw
• NIST Certificate of Calibration
Required Items:
• InTemp app
• Device with iOS or Android™
External Temperature Probe
Range -40° to 100°C (-40° to 212°F)
Accuracy CX40x-Txxx and CX402-BxM:
±1.0°C from -40° to -15°C (±1.8°F from -40° to 5°F)
±0.5°C from -15° to 80°C (±0.9°F from 5° to 176°F)
±0.7°C from 80° to 100°C (±1.3°F from 176° to 212°F)
CX40x-VFCxxx:
±1.0°C from -40° to -22°C (±1.8°F from -40° to -8°F)
±0.5°C from -22° to 50°C (±0.9°F from -8° to 122°F)
±1.0°C from 50° to 100°C (±1.8°F from 122° to 212°F)
Resolution 0.024°C at 25°C (0.04°F at 77°F)
Drift <0.1°C (0.18°F) per year
NIST Calibration CX40x-Txx and CX402-BxM: Single point NIST calibration, probe and
logger body
CX40x-VFCxxx: Single point NIST calibration, probe only
CX403: Single point NIST calibration
Cable Length 2 or 4 meter (6.56 or 13.12 feet) flat ribbon cable
Probe Dimensions Food-grade stainless steel probe with pointed tip, 53.34 mm (2.1 inches)
long, 3.18 mm (0.125 inches) diameter
Ambient Temperature Sensor
Range -30° to 70°C (-22° to 158°F)
Accuracy CX40x-Txxx and CX402-BxM:
±0.5°C from -15° to 70°C (±0.9°F from 5° to 158°F)
±1.0°C from -30° to -15°C (±1.8°F from -22° to 5°F)
CX40x-VFCxxx:
±1.0°C from -30° to -22°C (±1.8°F from -22° to -8°F)
±0.5°C from -22° to 50°C (±0.9°F from -8° to 122°F)
±1.0°C from 50° to 70°C (±1.8°F from 122° to 158°F)
Resolution 0.024°C at 25°C (0.04°F at 77°F)
Drift <0.1°C (0.18°F) per year
Logger
Radio Power 1 mW (0 dBm)
Transmission Range Approximately 30.5 m (100 ft) line-of-sight
Wireless Data Standard Bluetooth Low Energy (Bluetooth Smart)
Logger Operating Range -30° to 70°C (-22° to 158°F), 0 to 95% RH (non-condensing)
Logging Rate 1 second to 18 hours
19996-Q

InTemp CX400 Series Temperature Logger Manual
Specifications (continued)
Time Accuracy ±1 minute per month at 25°C (77°F)
Battery Type Two AAA 1.5 V alkaline or lithium batteries, user replaceable
Battery Life 1 year, typical with logging interval of 1 minute. Faster logging intervals,
Memory 128 KB (84,650 measurements, maximum)
Full Memory Download
Time
LCD LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or
Dimensions 9.4 x 4.5 x 2.59 cm (3.7 x 1.77 x 1.02 inches)
Weight 90.2 g (3.18 oz)
Environmental Rating IP54
Passed RTCA DO160G, part 21H
Logger Components and Operation
Audible alarm
speaker
Alarm LED
LCD
remaining connected with the InTemp app, excessive report generation,
numerous audible alarms, and paging all impact battery life.
Approximately 60 seconds; may take longer the farther the device is
from the logger
go blank in temperatures outside this range
The CE Marking identifies this pr
directives in the European Union (EU).
See last page
oduct as complying with all relevant
LCD: This screen shows the latest temperature reading and
other status information. The LCD screen refreshes at the same
rate as the logging interval. The example shows all symbols
illuminated on the LCD screen followed by a table with
descriptions of each symbol.
Start button
External
temperature
probe (CX402
models only)
Temperature
sensor (behind
rectangular
plug)
One of four
magnets (on
back of logger)
Mute or Next
button
Start Button: Press this button for 1 second to start the logger
when it is configured to start “on button push.”
Mute or Next Button: Press this button for 1 second to mute a
beeping alarm (see Logger Alarms). For CX402 loggers, press
this button for 1 second to switch between the external probe
and ambient internal sensor temperature readings.
Magnets: There are four magnets on the back of the logger (not
shown in diagram) for mounting.
Temperature Sensor: This internal sensor measures ambient
temperature.
External Temperature Probe: This is the probe that is plugged
into the logger for measuring temperature (CX402 models
only).
Audible Alarm Speaker: This is the speaker for the audible
alarm that beeps when an alarm is tripped or the external
probe is removed (if applicable).
Alarm LED: This LED blinks every 5 seconds when an alarm is
tripped or the external probe is removed (if applicable). See
Logger Alarms.
LCD Symbol Description
An alarm has tripped because the temperature
reading is outside the specified range
The logger has bee
twice daily checks (twice daily is shown in this
example), but no checks have been performed yet.
The once daily or t
this example) has been performed.
This indicates how much me
for the current configuration. In this example,
approximately 40 percent of the memory has been
used.
This shows the appr
remaining.
The logger is cu
The logger is cu
tablet via BlueTooth. The more bars there are, the
stronger the signal.
The logger is waiting to be star
the Start button for 3 seconds to start the logger.
n configured to perform daily or
wice daily logger check (twice in
mory has been used
oximate battery power
rrently logging.
rrently connected to a phone or
ted. Press and hold
2

InTemp CX400 Series Temperature Logger Manual
LCD Symbol Description
This is an example of a temperature reading from
an external probe.
This is an example of a temperature reading from
the internal sensor.
This is an example of a minimum temperature,
which is the lowest probe temperature reading
from the day (CX402 models) or the lowest
ambient temperature reading (CX403 model)
within the current 24-hour period (midnight from
one day to midnight the next day) if the logger
was set to record logger checks (see Performing
Logger Checks). Otherwise the minimum and
maximum readings represent the entire logging
period and only reset when the logger is
downloaded and restarted or stopped and
reconfigured.
This is an example of a maximum temperature,
which is the highest probe temperature reading
from the day (CX402 models) or the lowest
ambient temperature reading (CX403 model)
within the current 24-hour period (midnight from
one day to midnight the next day) if the logger
was set to record logger checks (see Performing
Logger Checks). Otherwise the minimum and
maximum readings represent the entire logging
period and only reset when the logger is
downloaded and restarted or stopped and
reconfigured.
The external prob
and
(if applicable).
MUTE indicates an alar
or
beeping alarm by pressing the Mute button. The
LCD then changes to MUTED.
The audible alarm has been
with your phone or tablet and then download reports, which
are saved in the app and automatically uploaded to
InTempConnect. The CX5000 Gateway is also available to
automatically configure and download loggers and upload data
to InTempConnect. Or, anyone can download a logger using the
InTempVerify app if the loggers are enabled to be used with
InTempVerify. If you do not need to access logged data via the
cloud-based InTempConnect software, then you also have the
option to use the logger with the InTemp app only
Follow these steps to begin using the loggers with
InTempConnect and the InTemp app.
e is not connected to the logger
m is beeping. Turn off the
muted.
The logger has been configur
a delay. The display will count down in days,
hours, minutes, and seconds until logging begins.
In this example, 5 minutes and 38 seconds remain
until logging will begin.
The profile settings ar
logger.
An erro
r occurred while loading the profile
settings onto the logger. Try reconfiguring the
logger.
The logger was paged from the
The logger has bee
with the InTemp app or because the memory is
full.
The logger is being
n downloaded and stopped
updated with new
ed to start logging on
e being loaded onto the
InTemp app.
firmware.
Note: If the logger has stopped logging because the memory is
full, the LCD screen will remain on with “STOP” displayed until
the logger is downloaded to your mobile device. Once the
logger has been downloaded, the LCD will turn off
automatically after 2 hours. The LCD will turn back on the next
time the logger connects with your device.
Getting Started
InTempConnect is web-based software where you can monitor
CX400 series logger configurations and view downloaded data
online. Using the InTemp app, you can configure the logger
3