The HOBO Temp/RH data logger records temperature and relative humidity (within 3.5%
accuracy) in indoor environments with its integrated sensors. Using HOBOware®, you can easily
configure the logger alarm to trip for specific high or low sensor readings. Or, you can set up burst
logging in which the logger records data at a different interval during certain conditions. The
logger can also calculate minimum, maximum, average, and standard deviation statistics. This
compact data logger has a built-in LCD screen to monitor the current temperature, relative
humidity, logging status, battery use, and memory consumption in between readouts.
Specifications
Temperature Sensor
Range -20° to 70°C (-4° to 158°F)
Accuracy ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F), see Plot A
HOBO Temp/RH 3.5%
Data Logger
UX100-003
Included Items:
• Command™ strip
• Double-sided tape
• Hook & loop strap
Required Items:
• HOBOware 3.4 or later
• USB cable (included with
software)
Resolution 0.024°C at 25°C (0.04°F at 77°F), see Plot A
Response Time 4 minutes in air moving 1 m/s (2.2 mph)
Drift <0.1°C (0.18°F) per year
RH Sensor
Range 15% to 95%
Accuracy ±3.5% from 25% to 85% over the range of 15° to 45°C (59° to 113°F)
Resolution 0.07% at 25°C (77°F) and 30% RH
Response Time 43 seconds to 90% in airflow of 1 m/s (2.2 mph)
Drift <1% per year typical
Logger
Logger Operating Range Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing)
Logging Rate 1 second to 18 hours, 12 minutes, 15 seconds
Logging Modes Normal, burst, or statistics
Memory Modes Wrap when full or stop when full
Start Modes Immediate, push button, date & time, or next interval
Stop Modes When memory full, push button, or date & time
Restart Mode Push button
Time Accuracy ±1 minute per month at 25°C (77°F), see Plot C
Battery Life 1 year, typical with logging rate of 1 minute and sampling interval of
Battery Type One 3V CR2032 lithium battery
Memory 128 KB (84,650 measurements, maximum)
Download Type USB 2.0 interface
Full Memory Download Time 20 seconds
LCD LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly
Size 3.66 x 8.48 x 1.52 cm (1.44 x 3.34 x 0.6 in.)
Weight 30 g (1.06 oz)
Environmental Rating IP50
including hysteresis; ±5% from 25% to 95% over the range of 5° to
55°C (41° to 131°F) including hysteresis, see Plot B
Launch/Readout: 0° to 50°C (32° to 122°F) per USB specification
15 seconds or greater
or go blank in temperatures outside this range
The CE Marking identifies this product as complying with all relevant
directives in the European Union (EU).
16209-E
HOBO Temp/RH 3.5% Data Logger (UX100-003) Manual
°
Specifications (continued)
100%
90%
80%
70%
60%
50%
40%
30%
20%
0 10203040 50 6050
Plot A: Temperature
Accuracy and Resolution
Not Specified
+/- 5%
+/-3.5%
C
Plot B: RH Accuracy
Plot C: Time Accuracy
Logger Components and Operation
Battery Door
Alarm/Stats Button
Start/Stop Button
Temperature Sensor
Mounting
Loop
Mounting
LCD Screen
USB Port
RH Sensor (behind
louvered door)
Start/Stop Button: Press this button for 3 seconds to start or
stop logging data, or to resume logging. This requires
configuring the logger in HOBOware with a push button start or
stop, and with “Resume logging on next button push” selected
(see Setting up the Logger). You can also press this button for
1 second to record an internal event (see Recording Internal Logger Events) or to turn the LCD screen on if the option to turn
off the LCD has been enabled (see Setting up the Logger).
Battery Door: Open the battery door on the top of the logger to
access the logger battery (see Battery Information).
Alarm/Stats Button: Use this button to clear a tripped alarm
(see Setting up Alarms) or to switch between statistics, alarm
readings, and the current sensor readings.
Mounting Loops: Use the two mounting loops to mount the
logger with the hook-and-loop strap (see Mounting the Logger).
Temperature Sensor: This sensor is located at the far right side
of the logger, slightly behind the louvered door in the logger
case.
RH Sensor: This sensor is located behind the louvered door in
the logger case to the right of the LCD screen.
Loop
USB Port: Use this port (not visible in the diagram) to connect
the logger to the computer or the HOBO U-Shuttle via USB
cable (see Setting up the Logger and Reading Out the Logger).
LCD Screen: This logger is equipped with an LCD screen that
displays details about the current status. This example shows all
symbols illuminated on the LCD screen followed by definitions
of each symbol in the table below.
LCD Symbol Description
The logger is waiting to be launched. Press and
hold the Start/Stop button for 3 seconds to launch
the logger.
The logger has been launched with a push button
stop enabled; press and hold the Start/Stop
button for 3 seconds to stop the logger. Note: If
you also launched the logger with a push button
start, this symbol will not appear on the display for
30 seconds.
The battery indicator shows the approximate
battery power remaining.
The logger has been configured to stop logging
when memory fills. The memory bar indicates the
approximate space remaining in the logger to
record data. When first launched, all five segments
in the bar will be empty. In this example, the
logger memory is almost full (only one segment in
the memory bar is empty).
The logger has been configured to never stop
logging (wrapping). The logger will continue
recording data indefinitely, with newest data
overwriting the oldest data. When first launched,
all five segments in the memory bar will be empty.
1-800-LOGGERS 2 www.onsetcomp.com
HOBO Temp/RH 3.5% Data Logger (UX100-003) Manual
LCD Symbol Description
In this example, the memory is full (all five
segments are filled in) and new data is now
overwriting the oldest data. This
the logger is stopped or the battery runs out.
The logger is currently logging.
A sensor reading is above or below the high or low
alarm that you configured. Press and release the
Alarm/Stats button until the “alm” symbol
(described below) is displayed on the screen. This
symbol at left will clear depending on how alarms
were configured in HOBOware. If the alarm was
configured to clear when the logger is relaunched,
this symbol will remain on the LCD. Otherwise, it
will clear when the sensor reading is back within
the alarm limits or by pressing the Alarm/Stats
button for 3 seconds.
An alarm is ready to be cleared. This will only
appear if “Cleared with button press” was selected
in the HOBOware alarm settings. Press the
Alarm/Stats button for 3 seconds to clear the
alarm.
These symbols show the maximum, minimum,
average, and standard deviation values most
recently calculated for the logger (if the logging
mode has been set to Statistics in HOBOware).
Press the Alarm/Stats button for 1 second to cycle
through each of the available statistics and then
back to the current sensor reading (or to the alarm
value if applicable).
This is the sensor reading that tripped the alarm.
Press the Alarm/Stats button to view this reading.
Press the Alarm/Stats button again to cycle
through any statistics (defined above) and
ultimately back to the current sensor reading.
This is an example of a temperature reading.
Temperature units are determined by the settings
in HOBOware. To switch between Celsius and
Fahrenheit, change the Display Preferences in
HOBOware before launching the logger.
This is an example of an RH reading.
The logger has been configured to start logging on
a particular date/time. The display will count down
in days, hours, minutes, and seconds until logging
begins. In this example, 5 minutes and 38 seconds
remain until logging will begin.
The launch settings are being loaded onto the
logger from HOBOware. Do not disconnect the
USB cable during this process.
An error occurred while loading the launch
configurations onto the logger from HOBOware.
Make sure the USB cable is connected to both the
logger and the computer and try launching again.
The logger has been stopped with HOBOware or
because the memory is full.
will
continue until
Notes:
• You can disable the LCD screen when logging. Select
“Turn LCD off” when setting up the logger as described in
the next section. When this option is enabled, you can
still temporarily view the LCD screen by pushing the
Start/Stop button for 1 second. The LCD will then remain
on for 10 minutes.
• The LCD screen refreshes every 15 seconds regardless of
the logging interval selected in HOBOware. If you choose
a logging interval less than 15 seconds, the data will be
recorded at the faster interval, but the sensor readings
will only be updated on the screen every 15 seconds.
• When the logger has stopped logging, the LCD screen will
remain on until the logger is offloaded to a computer or
HOBO U-Shuttle (unless launched with the “Turn LCD off”
option). Once the logger has been offloaded and
disconnected from the computer, the LCD will turn off
automatically after 2 hours. The LCD will turn back on the
next time the logger is connected to the computer.
Setting up the Logger
Use HOBOware to set up the logger, including setting alarms,
selecting the options to start and stop logging, and choosing a
logging mode.
1.Connect the logger and open the Launch Logger window.
To connect the logger to a computer, use the USB cable
provided. Click the Launch icon on the HOBOware toolbar
or select Launch from the Device menu.
Important: USB 2.0 specifications do not guarantee
operation outside the range of 0°C (32°F) to 50°C (122°F).
2.Select the sensors to log in this deployment. Choose
Temperature or Temperature and RH. Type a label for the
sensor(s) if desired. Note that both sensors are required to
calculate dew point, which is an additional data series
available for plotting after reading out the logger.
3.Set up alarms (optional). Click the Alarms button if you
want to configure an alarm to trip when the sensor reading
is above or below a value you specify. See Setting up Alarms
for details.
4.Configure filters (optional). Click the Filters button to
create additional filtered data series. Any filtered series will
be available automatically upon reading out the logger.
5.Select the Logging Interval. Select a logging interval from 1
second to a maximum of 18 hours, 12 minutes, and 15
seconds.
6.Select the Logging Mode:
1-800-LOGGERS 3 www.onsetcomp.com
Loading...
+ 5 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.