Operating Instructions for XER6022, XER6022-SS, XER1022 & XER1032
Explosion-Proof Classification
The explosion-proof models of safety interlock switches are specifically designed for potentially explosive atmospheres while retaining the features and operating characteristics of the conventional models. A sealed flameproof contact block makes the explosion-proof interlock switches suitable for use in European Zone 1 and Zone 2 environments, which are typical of those found in the chemical and petrochemical industries. All switches are classified by the European method as EEx d II C T6. For a full explanation of the classification method, see “Hazardous Location Rating Systems for Interlock Switches” in The Safety Library Section of this catalog. WARNING: These switches are not suitable for use in atmospheres containing Group I gases, e.g., methane (firedamp). These switches DO NOT meet all conditions of the US classification of Class I, Div 1, due to the differences between European and US classification methods. In the US and Canada, these products can be used in areas classified as Class I, Division 2 in Groups A (acetylene), B (hydrogen), C (ethylene) and D (propane).
Installation must be in accordance with the following steps and stated specifications and should be carried out by suitably competent personnel. Adherence to the recommended maintenance instructions forms part of the warranty.
WARNING: Do not defeat, tamper, remove or bypass this unit. Severe injury to personnel could result.
XER6022 XER6022-SS
cable entry
40
49
63
7 89
23
32
10
All Dimensions in mm
XER1032
96
4 Mounting Holes Clearance for M5 Screws
Optional E-Stop Button
4 Mounting Holes Clearance
222 min - 239 max
327 min - 361 max
Optional E-Stop Button
86
100
for M5 Screws
86
54
23
143
110
29
10 25
96
60
92
XER1022
223 min - 240 max
Optional E-Stop Button
96
4 Mounting Holes Clearance for M5 Screws
27.50
cable entry
All Dimensions in mm
Tension Indicator
Indicator shown with steel rope properly adjusted.
1NC + 1NO
86
100
34
Left Sided Model: XER1022-011C3L
2NC + 2NO
143
92
110
29
10 25
60
27.50
cable entry
All Dimensions in mm
Contact Arrangement: XER6022, XER6022-SS, XER1022 and XER1032 Models
Rope Slack
1NC/2NC/3NC
1NO/2NO
34
Tension Range
2NC
3NC + 1NO
Rope Pulled
Contact open Contact closed
XER Series
Operating Instructions for XER6022, XER6022-SS, XER1022 & XER1032
1. Installation of all Safety Rope Switch systems must be in accordance with a risk assessment for the individual application. Installation must only be carried out by
competent personnel and in accordance with these instructions.
2. Rope support eyebolts must be fitted at 2.5m. min. to 3m. max. intervals along all rope lengths between switches. The rope must be supported no more than 500mm
from the switch eyebolt or Safety Spring (if used). It is important that this first 500mm is not used as part of the active protection coverage.
3. M5 mounting bolts must be used to fix the switches. Tightening torque for mounting bolts to ensure reliable fixing is 4Nm. Tightening torque for the lid screws,
conduit entry plugs and cable glands must be 1.5Nm to ensure IP seal. Only use correct sizing glands for conduit entry and cable outside diameter.
4. Tensioning of rope is achieved by use of tensioner / gripper assemblies. Upon installation, tension to mid-position as indicated by the red arrows in the viewing window of each switch. Check operation for all switches and the control circuits by puling the rope at various locations along the active protection area and resetting each switch by depressing the Blue Reset button. Ensure each time that the switches latch off and require manual resetting by depressing the Blue Reset button. Increase the system tension further, if required, depending upon the checks along the active length of coverage. If fitted with a Mushroom type E-Stop button (Red) then test and reset each switch to ensure function of control circuits. Typical operational conditions for successful operation of system is less than 75N. pulling force and less than 150mm deflection of rope between eyebolt supports.
Every week: Check correct operation of system at locations along all coverage length. Check for nominal tension setting, re-tension rope if necessary. Every 6
5. months: Isolate power and remove cover. Check screw terminal tightness and check for signs of moisture ingress. Never attempt to repair any switch.
Mechanical Features
Enclosure / Cover Die-cast – painted yellow
XER6022-SS = 316 stainless steel External Parts Stainless steel IP Rating IP67 Rope Spans Max XER1022, XER1032 (heavy duty),
dual head 200m., single head 125m.
XER6022 (standard duty) = 80m
XER6022-SS = 100m
Mounting 4 x M5
Mounting position Any
Conduit entries 3m cable (all models)
Torque settings Mounting = M5 4.0 Nm
Lid = Torx M4 1.5 Nm
Terminals = 1.0 Nm
Ambient Operating Temperature -25C. to 80 C.
Vibration resistance 10-500Hz 0.35mm
Shoc
k resistance 15g 11ms
Tension Force (typical mid setting) 130 N
Typical Operating Force (Rope pulled) < 125N. < 300mm deflection Mechanical Life 1,000,000 operations Weight XER1022, XER1032 (heavy duty)
dual 1320 g. single 1100 g.
XER6022 (standard duty) 880 g XER6022-SS 1635 g
Electrical
Ex Classification II 2 G EEx d II C T6
Certificates Baseefa11ATE0267X IECEx BAS 11.0133X
Contact Configuratoins 2NC, 1 NC + 1NO, 2NC + 2NO, 3NC + 1NO
Safety Contacts 1 N/C , 2NC
Rated Voltage AC15 400 VAC 250 VDC 250 VDC
Rated Curent CD13 2A AC 4A AC 0.15A DC
AC Ratings (switching) 250V 125V
Resistive 5A 5A
Inductive 3A 3A
DC Ratings (switching) 250V 125V 30V
Resistive 0.4A 0.8A 7A
Inductive 0.03A 0.06A 5A
Electric Life 1,000,000 operations
Exclusion of Liability Under the Following Circumstances
incorrect use non-compliance with safety regulations installation and electrical connection not performed by authorized personnel. failure to perform functional checks.
EC Declaration of Conformity
The manufacturer named below herewith declares that the product fulfills the provisions of the directive(s) listed below and that the related standards have been applied.
OMRON Scientific Technologies Inc. 6550 Dumbarton Circle Fremont, CA 94555, U.S.A.
Directives applied: Machinery directive 2006/42/EC Low Voltage directive 2006/95/EC Potential Explosive Atmosphere 94/9/EC RoHS directive 2011/65/EC
Standards applied: EN 60947-1:2007+A1:2011 EN 60947-5-1:2004:+A1:2009 EN 60947-5-5:1997+A1:2005 EN 60204-1:2006:+A1:2009 EN 60079-0:2011 EN 60079-1:2007 EN 60079-31:2009 ISO 13850:2006 ISO 13849-1 EN50013
Fremont, March 2013
Marty Krikorian Director, Quality Control
Information with regard to UL 508 Use polymeric conduit only. Use copper conductors only.
Electrical rating: A300. Type 1 enclosures
Approvals
CE, ATEX per EC-Type Examination
©2013 Omron Scientific Tetchnologies, Inc. All rights reserved.
Reference P/N 99916-0010 Rev.B