Omron Varispeed J7 CIMR-J7AZ System Configuration Manual

Page 1
CIMR-J7AZ
Varispeed J7
Small, simple and smart
• V/f controlled inverter
• Compact size
• Good torque performance: 100% torque at 1.5 Hz, 150% at 3 Hz
• Overload detection function.
• Motor thermal function
• Freely configurable V/f curve
• 4 programmable digital input
• 1 programmable digital output
• 1 programmable analog output
• Optional RS-232C/485 communication - Modbus
• PC Configuration tool: CX-drive
• CE, UL, and cUL marking
Ratings
• 200 V class single-phase 0.1 to 1.5 kW
• 200 V class three-phase 0.1 to 4.0 kW
• 400 V class three-phase 0.2 to 4.0 kW
System configuration
SI-485/J7
Line filter
SI-232/J7 SI-232/J7C
CX-Drive
JVOP-144 Remote digital oper. with potentiometer
Varispeed J7
JVOP-146 Remote digital oper. with potentiometer
3G3IV-PCN329-E Inverter to PC cable
3G3IV-PEZZ8122_ DIN attachment
3G3IV-PCN126/326 Digital operator extension cable
351Varispeed J7
Page 2
Specifications
Type designation
CIMR—J7AZ20P1
Inverter
J7 series
A: With digital operator (with potentiometer)
Z: European standard specifications
Voltage class 200 V single/three-phase 400 V three-phase
Model CIMR-J7AZ#
Max. applicable
motor output kW (HP)
Inverter capacity kVA
Rated output current A
Output
Power
1. Single-phase series inverter output is three-phase (for three-phase motors)
2. Based on a standard 4-pole motor for max. applicable motor output. Select the inverter model whose rated current is larger than motor rated current.
Max. output voltage V
characteristics
Max. output frequency
Rated input voltage
supply
Allowable frequency
Three-phase 20P1 20P2 20P4 20P7 21P5 22P2 24P0 40P2 40P4 40P7 41P5 42P2 43P0 44P0
Single-phase
and frequency
Allowable voltage
function
function
1
B0P1B0P2B0P4B0P7B1P5–––––––––
2
0.12 0.25 0.55 1.1 1.5 2.2 4.0 0.37 0.55 1.1 1.5 2.2 3.0 4.0
0.3 0.6 1.1 1.9 3.0 4.2 6.7 0.9 1.4 2.6 3.7 4.2 5.5 7.0
0.8 1.6 3 5 8 11 17.5 1.2 1.8 3.4 4.8 5.5 7.2 9.2
3-phase, 200 to 230 V (proportional to input voltage)
Single-phase, 200 to 240 V (proportional to input voltage)
3-phase, 200 to 230 V, 50/60 Hz
Single-phase, 200 to 240 V, 50/60 Hz
Max. applicable motor output 0P1: 0.1 kW
~
4P0: 4.0 kW
"P" indicates a decimal
[ ]
point
Voltage B: Single-phase 200 VAC 2: Three-phase 200 VAC 4: Three-phase 400 VAC
3-phase, 380 to 460 V (proportional to input voltage)
400 Hz (programmable)
3-phase, 380 to 460 V, 50/60 Hz
–15 to +10%
±5%
352 Frequency inverters
Page 3
Commom specifications
Model
CIMR-J7AZ# Control method Output frequency range Frequency tolerance
Resolution of frequency set value
Resolution of output frequency Overload capability Frequency set value Accel/decel time
Control functions
Braking torque
V/f characteristics Digital inputs Four of the following input signals are selectable: forward/reverse run (3-wire sequence), fault reset, external fault (NO/NC
Digital outputs Following output signals are selectable (NO/NC contact output): Fault, running, zero speed, speed agreed,
Standard functions Full-range automatic torque boost, slip compensation, 9-step speed operation (max.), restart after momentary power loss,
Functionality
Display
Motor overload protection Instantaneous overcurrent Overload Overvoltage Undervoltage
Momentary power loss
Cooling fin overheat
Protection
Stall prevention level
Cooling fan fault Ground fault Power charge indication
Degree of protection Cooling
Ambient temperature Ambient humidity Storage temperature Installation Installation height
Ambient conditions
Vibration
1. Shows deceleration torque for uncoupled motor decelerating from 60 Hz with the shortest possible deceleration time.
contact input), multi-step speed operation, jog command, accel/decel time select, external baseblock (NO/NC contact input), speed search command, UP/DOWN command, accel/decel hold command, LOCAL/REMOTE selection, communication/ control circuit terminal selection, emergency stop fault, emergency stop alarm, self test
frequency detection (output frequency or set value), during overtorque detection, minor error, during baseblock, operation mode, inverter run ready, during fault retry, during undervoltage detection, reverse running, during speed search, data output through communication
DC injection braking current at stop/start (50% of inverter rated current, 0.5 sec, or less), frequency reference bias/gain, fault retry, speed search, frequency upper/lower limit setting, overtorque detection, frequency jump, accel/decel time switch, accel/ decel prohibited, S-curve accel/decel, frequency reference with built-in volume, constants copy (option) MEMOBUS commu­nications (option)
0 to 10 VDC (20 kΩ), 4 to 20 mA (250 Ω), 0 to 20 mA (250 Ω), frequency setting volume (selectable)
ON until the DC bus voltage becomes 50 V or less, RUN lamp stays ON or digital operator LED stays ON.
Self cooling for 200 V 0,1..0,75 kW (single-phase) 0,1..0,4 kW (Three-phase) and for 400 V 0,2..0,75l kW
Digital reference: 0.01 Hz (less than 100 Hz), 0.1 Hz (100 Hz or more)
Short-term average deceleration torque
Digital operator: available to monitor frequency reference, output frequency, output current
Protected by electronic circuit (operation level is approx. 250% of rated output current)
Cooling fan for 200 V (single-phase), 0.75 kW..4.0 kW (3-phase) and for 400 V 1,5..4.0 kW
0.1 to 999 sex. (accel/decel time are independently programmed)
Status indicator LED: RUN and ALARM provided as standard LED’s
Motor coasts to a stop at approx. 250% of inverter rated current
Motor coasts to a stop after 1 minute at 150% of inverter rated output current
Motor coasts to a stop if DC bus voltage exceed 410 V (double for 400 V class)
Stops when DC bus voltage is approx. 200 V or less (double for 400 V class)
Following items are selectable: Nnot provided (stop if power loss is 15ms or longer),
continuous operation if power loss is approx. 0.5 s or shorter, continuous operation
Individual level stall prevention can be set during acceleration or constant running,
Digital reference: ±0.01% (–10 to +50 °C),
Analog reference: ±0.5% (25±10 °C)
Analog reference: 1/1000 of max. output frequency
150% rated output current for one minute
0.4/0.75 kW (0,5 HP, 1HP): 100% or more;
2.2 kW (3 HP) or more: 20% or more
Continuous regenerative torque: Approx 20%
(approx. 160 V or less for single-phase series)
provided/not provided setting available during deceleration.
Detected by electronic circuit (fan lock detection)
-20 ºC..+60 ºC (short-term temperature during trasnportation)
10 to 20 Hz, 9.8 m/s2 max; 20 to 50 Hz, 2m/s2 max
Specifications
Sine wave PWM (V/f control)
0.1 to 400 Hz
0.01 Hz
1
: 0.1, 0.2 kW (0.13 HP, 0,25 HP): 150% or more;
1.5 kW (2 HP): 50% or more;
Possible to program any V/f pattern
Electronic thermal overload relay
Protected by thermister
(Charge LED is provided for 400 V)
-10 ºC to 50 ºC (non-freezing)
90% RH or less (non-condensing)
Indoor (no corrosive gas, dust, etc.)
IP20
Max. 1000 m
Varispeed J7 353
Page 4
Digital operator
Data display
Digital operator
Function display LEDs
Selected function is lit (see the functions below). Its data is displayed on data display.
Display selection key
Switch functions among function display LEDs.
Enter key
Enter data when setting constants. After selecting constant no. at PRGM mode, data are displayed.
Increment key
Increase constant no. or data.
Decrement key
Decrease constant no. or data.
Stop/Reset key
Press to stop the motor. If fault occurs, reset the inverter.
Operation key
Press to run the motor. The RUN light is ON while running.
Alarm LED
Run LED
Frequency setting volume
Set operational frequency with volume.
354 Frequency inverters
FREF
Frequency reference
setting/monitoring
F/R
Operator RUN command
FWD/REV selection
FOUT
Output frequency
monitoring
IOUT
Output current
monitoring
LO/RE
LOCAL/REMOTE
selection
MNTR
Multi-function
monitoring
PRGM
Constant no./data
Page 5
Dimensions
IP 20 type 0.1 to 4 kW
2 – M 4
4 – M 4
Voltage class
200 V
three-phase
200 V
single-phase
400 V
three-phase
8.5
(0.34)
Figure 1 Figure 2
Max. applicable
motor output kW
0.12
0.25
0.55
1.1
1.5
2.2
4.0
0.1
0.2
0.4
0.75
1.5
0.37
0.55
1.1
1.5
2.2
3.0
4.0
Inverter model
CIMR-J7AZ#
20P1 20P2 20P4 20P7 21P5 22P2 24P0 B0P1 B0P2 B0P4 B0P7 B1P5 40P2 40P4 40P7 41P5 42P2 43P0 44P0
Figure
1 68 128 70 56 118 5 0.5 Self cooled
2 108 129 96 118 1.3
1 68 128 70 56 118 5 0.5 Self cooled
2 108 129 96 1.5 Fan cooled
2 108 128 81 96 118 5 1.0 Self cooled
W H D W1 H1 H2
140 161 128 2.1
140 161 128 2.1
Dimensions in mm
102 0.8 122 0.9 Fan cooled
154 1.5
112 0.9
154
99 1.1 129 1.5 154
8.5
(0.34)
Weight kg
7.7
Cooling method
Fan cooled
Varispeed J7 355
Page 6
Filters
Schaffner model
3x200 V 3G3JV-PFI2010-SE 194 82 50 160 181 62 5.3 M5 25 56 118 M4
3G3JV-PFI2020-SE 169 111 50 135 156 91 5.5 M5 25 96 118 M4
1x200 V 3G3JV-PFI1010-SE 169 71 45 135 156 51 5.3 M5 22 56 118 M4
3G3JV-PFI1020-SE 169 111 50 135 156 91 5.3 M5 25 96 118 M4
3x400 V 3G3JV-PFI3005-SE 169 111 50 135 156 91 5.3 M5 22 96 118 M4
3G3JV-PFI3010-SE 169 111 50 135 156 91 5.3 M5 22 96 118 M4 3G3JV-PFI3020-SE 174 144 50 135 61 120 5 M5 28 128 118 M4
A B C D E F G H I J K L
Output flexes
Dimensions
Drive mounts
Rasmi model
3x200 V 3G3JV-PFI2010-E 82 50 194 181 62 M5
3G3JV-PF2020-E 111 50 169 156 91 M5
3G3JV-PFI2030-E 144 50 174 161 120 M5
1x200 V 3G3JV-PFI1010-E 71 45 169 156 51 M5
3G3JV-PFI1020-E 111 50 169 156 91 M5
3x400 V 3G3JV-PFI3005-E 111 50 169 156 91 M5
3G3JV-PFI3010-E 111 50 169 156 91 M5 3G3JV-PFI3020-E 144 50 174 161 120 M5
356 Frequency inverters
W H L X Y Inverter fixing
Dimensions
Page 7
DIN rail mounting bracket
3G3IV-PEZZ08122A
3G3IV-PEZZ08122C
Four, M4 tap
(35.1)
DIN rail
3G3IV-PEZZ08122B
Four, M4 tap
(35.1)
DIN rail
3-phase 200 VAC
Single-phase 200 VAC
3-phase 400 VAC
Four, M4 tap
Inverter DIN rail mounting bracket
CIMR-J7AZ20P1/20P2/20P4/20P7 3G3IV-PEZZ08122A CIMR-J7AZ21P5/22P2 3G3IV-PEZZ08122B CIMR-J7AZ24P0 3G3IV-PEZZ08122C CIMR-J7AZB0P1/B0P2/B0P4 3G3IV-PEZZ08122A CIMR-J7AZB0P7/B1P5 3G3IV-PEZZ08122B CIMR-J7AZ40P2/40P4/40P7/41P5/42P2 3G3IV-PEZZ08122B CIMR-J7AZ43P0/44P0 3G3IV-PEZZ08122C
Varispeed J7 357
Page 8
Installation
Standard connections
Forward run/stop
Reverse run/stop
Multi­function input
Fault reset External fault
(no contact) Multi-step speed
reference 1
Frequency reference
MCCB
R
S
T
Pulse train input
2 kΩ
P
P
Frequency setter
indicates shielded wire.
DC reactor (option)
UX
short
bar
+2 +1 ­R/L1
S/L2
T/L3
Varispeed J7AZ
S1
S2
S3
S4
S5
SC
Shield connection terminal
Frequency setting power supply (+12 V 20 mA)
FS
Speed frequency reference
FR
0 To 10 V (20 kΩ ) or 4 to 20mA (250 Ω )
FC
or O to 20 mA (250
0V
Digital operator frequency setting volume
min
Ω
max
)
U/T1
V/T2
W/T3
MA MB MC
AM
AC
IM
Grounding
Multi-function
Running
Speed reference pulse train (33 kHz max.)
Frequency meter adjusting potentiometer
P
Output frequency
output 250 VAC 1 A or less 30 VDC 1 A or less
Analog monitor output
FM
0 To 10 VDC (2 mA)
indicates twisted pair
P
shielded wire.
: shows the connection for the following two kinds of sequence input (S1 to S5) signals: no-voltage contact and NPN transistors (0 V common). For a PNP transistor (+24 V common), a 24 V external power supply is necessary.
358 Frequency inverters
Page 9
Main circuit
Terminal Name Function (signal level)
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
+2, +1
+1, –
AC power supply input
Inverter output
DC reactor connection
DC power supply input
Grounding
Main circuit power supply input (Use R/L1 and S/L2 for single-phase power supply inverter. Do not use T/L3 of the models less than 0.75kW for other usage, such as a junction terminal.)
For inverter output
Remove the short bar between +2 and +1 when connecting DC reactor (option)
For power supply input (+1: positive electrode; – : negative electrode)*
For grounding (grounding should conform to the local grounding code.)
Control circuit
Type No. Signal name Function Signal level
Multi-function input selection 1 Factory setting: runs when CLOSED, stops when OPEN. 24VDC, 8mA
Multi-function input selection 2 Factory setting: runs when CLOSED, stops when OPEN.
Multi-function input selection 3 Factory setting: "fault reset"
Multi-function input selection 4 Factory setting: "external fault (NO contact)"
Multi-function input selection 5 Factory setting: "multi-step speed reference 1"
Multi-function input selection common
Power supply terminal for frequency setting
Speed frequency reference 0 to +10 VDC (20 kΩ) or 4 to 20 mA (250 Ω), 0 to 20 mA (250 Ω) (resolution 1/1000)
Frequency reference common 0 V
NO contact output Factory setting: "running" Contact capacity
NC contact output
Contact output common
Analog monitor output Factory setting: "output frequency" 0 to +10 V output 0 to 10 V 2 mA or less
Analog monitor common 0 V
Common for control signal
+12V (allowable current: 20 mA max.)
photocoupler isolation
250 VAC, 1A or less 30 VDC, 1A or less
Resolution: 8bits
Digital input signals
input
Analog
signals
Digital
output
signals
output
Analog
signals
S1
S2
S3
S4
S5
SC
FS
FR
FC
MA
MB
MC
AM
AC
Varispeed J7 359
Page 10
30 mm min. (0.1 to 4.0 KW)
W=
50 mm min. (5.5 and 7.5 KW)
100 mm min.
Air
Inverter
Inverter heat loss
Three-phase 200 V class
CIMR-J7AZ# 20P1 20P2 20P4 20P7 21P5 22P2 24P0
Inverter capacity kVA 0.3 0.6 1.1 1.9 3.0 4.2 6.7
Rated current A 0.8 1.6 3.0 5.0 8.0 11.0 17.5
Heat
loss W
Single-phase 200 V class
CIMR-J7AZ# B0P1 B0P2 B0P4 B0P7 B1P5
Inverter capacity kVA 0.3 0.6 1.1 1.9 3.0
Rated current A 0.8 1.6 3.0 5.0 8.0
Heat
loss W
Three-phase 400 V class
CIMR-J7AZ# 40P2 40P4 40P7 41P5 42P2 43P0 44P0
Inverter capacity kVA 0.9 1.4 2.6 3.7 4.2 5.5 7.0
Rated current A 1.2 1.8 3.4 4.8 5.5 7.2 9.2
Heat
loss W
Inverter Inverter
100 mm min.
Fin 3.7 10.3 15.8 28.4 53.7 60.4 96.7
Inside unit 9.3 18.0 12.3 16.7 19.1 34.4 52.4
Total heat loss 13.0 18.0 28.1 45.1 72.8 94.8 149.1
Fin 3.7 7.7 15.8 28.4 53.7
Inside unit 10.4 12.3 16.1 23.0 29.1
Total heat loss 14.1 20.1 31.9 51.4 82.8
Fin 9.4 15.1 30.3 45.8 50.5 58.2 73.4
Inside unit 13.7 15.0 24.6 29.9 32.5 37.6 44.5
Total heat loss 23.7 30.1 54.9 75.7 83.0 95.8 117.9
Side
Air
360 Frequency inverters
Page 11
AC reactor
DC reactor
AC reactor
L1(R) L2(S) L3(T)
MCCB
U
X V W
L1(R)
Y
L2(S)
Z
L3(T)
T1(U) T2(V) T3(W)
Motor
IM
CIMR-J7AZ
Be sure to connect AC reactor on inverter input side [L L
2 (S), L3 (T)].
200 V class 400 V class Max. applicable
motor output kW
0.1 2.0 2.0 ------
0.22.02.00.2
0.42.54.20.4
0.75 5 2.1 0.75 2.5 8.4
1.5 10 1.1 1.5 5 4.2
2.2 15 0.71 2.2 7.5 3.6
4.0 20 0.53 4.0 10 2.2
Current value AInductancemHMax. applicable
MCCB
motor output kW
DC reactor
Current value AInductance
Motor
1 (R),
mH
1.3 18.0
CIMR-J7AZ
200 V class 400 V class Max. applicable
motor output kW
0.12 5.4 8 --------
0.25 0.37 3.2 28
0.55 0.55
1.1 1.1
1.5 18 3 1.5 5.7 11
2.2 2.2
4.0 4.0 12 6.3
Current value AInductance
mH
Max. applicable motor output kW
Current value AInductance
mH
Varispeed J7 361
Page 12
Ordering information
SI-485/J7
B
Line filter
A
Varispeed J7
SI-232/J7 SI-232/J7C
CX-Drive
JVOP-144 Remote digital oper. with potentiometer
Varispeed J7
JVOP-146 Remote digital oper. with potentiometer
3G3IV-PCN329-E Inverter to PC cable
B
3G3IV-PEZZ8122_ DIN attachment
3G3IV-PCN126/326 Digital operator extension cable
200 V
Specifications Model
1x200 V 0.12 Kw 0.8 A CIMR-J7AZB0P10
0.25 Kw 1.6 A CIMR-J7AZB0P20
0.55 Kw 3.0 A CIMR-J7AZB0P40
1.1 Kw 5.0 A CIMR-J7AZB0P70
1.5 Kw 8.0 A CIMR-J7AZB1P50
3x200 V 0.12 Kw 0.8 A CIMR-J7AZ20P10
0.25 Kw 1.6 A CIMR-J7AZ20P20
0.55 Kw 3.0 A CIMR-J7AZ20P40
1.1 Kw 5.0 A CIMR-J7AZ20P70
1.5 Kw 8.0 A CIMR-J7AZ21P50
2.2 Kw 11.0 A CIMR-J7AZ22P20
4.0 Kw 17.5 A CIMR-J7AZ24P00
362 Frequency inverters
400 V
Specifications Model
3x400 V 0.37 Kw 1.2 A CIMR-J7AZ40P20
0.55 Kw 1.8 A CIMR-J7AZ40P40
1.1 Kw 3.4 A CIMR-J7AZ40P70
1.5 Kw 4.8 A CIMR-J7AZ41P50
2.2 Kw 5.5 A CIMR-J7AZ42P20
3.0 Kw 7.2 A CIMR-J7AZ43P00
4.0 Kw 9.2 A CIMR-J7AZ44P00
Page 13
ALine filters
12.2 (0.48)
9.3 (0.37)
1.7 (0.07)
Voltage Model CIMR-J7AZ Schaffner Rasmi Rated current (A) Weight (kg)
Inverter Line filter
20P1 / 20P2 / 20P4 / 20P7 3G3JV-PFI2010-SE 3G3JV-PFI2010-E 10 0.68
3-phase 200 VAC
21P5 / 22P2 3G3JV-PFI2020-SE 3G3JV-PFI2020-E 16 0.84
24P0 --- 3G3JV-PFI2030-E 26 1.0
Single-phase 200 VAC
B0P1 / B0P2 / B0P4 3G3JV-PFI1010-SE 3G3JV-PFI1010-E 10 0.45
B0P7 / B1P5 3G3JV-PFI1020-SE 3G3JV-PFI1020-E 20 0.68
40P2 / 40P4 3G3JV-PFI3005-SE 3G3JV-PFI3005-E 5 0.57
3-phase 400 VAC
40P7 / 41P5 / 42P2 3G3JV-PFI3010-SE 3G3JV-PFI3010-E 10 0.67
43P0 / 44P0 3G3JV-PFI3020-SE 3G3JV-PFI3020-E 20 / 15 1.0
B Accessories
Type Model Description Funtions
Digital operator
JVOP-146
JVOP-144
Remote digital operator
without potentiometer
Remote digital operator
with potentiometer
11
23.1
11
(0.43)
58 (2.28)
23.1
(0.91)
(0.43)
58 (2.28)
(0.91)
DATA
DSPL
DATA
ENTER
78 (3.07) 88 (3.46)
(15.5)
STOP
78 (3.07) 88 (3.46)
RUN
STOP RESET
15.5 (0.61)
4-4.4 dia. MTG holes
5
(0.2)
4-4.4 dia. MTG holes
DIGITAL OPERATOR JVOP-140
MIN MAX
80 (3.15)
5
1.7 (0.07)
1.7 (0.07)
12.2 (0.48)
12.2 (0.48)
(0.2)
80 (3.15)
1.7
(0.07)
12.2
(0.48)
9.3 (0.37)
9.3 (0.37)
30.4
(1.20)
30.4
(1.20)
10.5 (0.41)
10.5 (0.41)
50 (1.97)
18.2 (0.72)
18.2 (0.72)
50 (1.97)
56 (2.20)
4-M4 spot facing deep 3.5 (0.14)
56 (2.20)
4-M4 spot facing deep 3.5 (0.14)
68 (2.68)
68 (2.68)
Varispeed J7 363
Page 14
Type Model Description Funtions
SI-232/J7 (3G3JV-PSI232J)
Another option SI-232/J7C (3G3JV-PSI232JC) is available, the only difference is that this one is removable.
RS232 adapter
16
(0.63)
15.5
(0.61)
21.5 (0.85)
63(2.48)
29
(1.14)
2.5 (0.1)
19 (0.75)
8(0.31
SI-485/J7 (3G3JV-PSI485J)
Interface units
RS485 adapter
SI232/J7 must be connected
SI232/J7 must be connected
Accessories
3G3IV-PCN126 3G3IV-PCN326
3G3IV-PCN329-E
Digital operator extension cable
1 meter
3 meters
PC configuration cable
B Accessories
Type Model Description Installation
Software
CX-drive Computer software Configuration and monitoring software tool for drives.
CX-One Computer software Complete OMRON automation software including CX-drive.
16(0.63)
12 (0.47)
13(0.51)
4 3.8(0.15)=15.2(0.6)
63 (2.48)
29
(1.14)
8
19
(0.3) (0.75)
(0.3)
8
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. I19E-EN-02
In the interest of product improvement, specifications are subject to change without notice.
364 Frequency inverters