Omron V740-BA50C24-US, V740, V740-BA50C04-US, V740-HS01L, V740-HS01C Operation Manual

Page 1
Table of Contents
1. Installation and Usage Guide ........................................................................................ 3
1.1 Before You Begin................................................................................................................................... 4
1.1.1 Installation Requirements............................................................................................................. 4
1.1.2 Performance Considerations........................................................................................................ 4
1.2 Authorized Antennas .............................................................................................................................5
1.2.1 Antennas ...................................................................................................................................... 5
1.2.2 Antenna Cables(Options)............................................................................................................. 5
1.2.3 Setting the Reader RF Power ...................................................................................................... 5
1.3 Reader Installation.................................................................................................................................6
1.3.1 Install the Reader ......................................................................................................................... 6
1.3.2 Install the Antennas...................................................................................................................... 6
1.3.3 Connect the Reader ..................................................................................................................... 6
1.4 Reader Configuration............................................................................................................................. 9
1.5 Reader Service .................................................................................................................................... 10
1.5.1 Using the Browser-Based Interface ...........................................................................................10
1.5.2 Restarting the Reader ................................................................................................................18
1.5.3 Using Safe Mode........................................................................................................................ 18
1.6 Tag Fundamentals............................................................................................................................... 20
1.7 Specifications....................................................................................................................................... 21
2. Query Protocol ............................................................................................................. 22
2.1 Transport Protocol ............................................................................................................................... 22
2.1.1 TCP Connection Setup and Teardown ...................................................................................... 22
2.2 Event/Query Protocol........................................................................................................................... 23
2.2.1 Client Software Requests/Functionality .....................................................................................23
2.2.2 General Observations, Commands, and Syntax........................................................................ 24
2.2.3 Extended RQL Command Structure supported by the V740 Reader........................................ 24
2.2.4 Detailed Command Structure..................................................................................................... 25
2.2.4.1 ID Read ................................................................................................................................... 25
2.2.4.2 ID Write ...................................................................................................................................29
2.2.4.3 Reader Control........................................................................................................................ 31
2.2.4.4 Get Information........................................................................................................................35
2.2.5 Errors.......................................................................................................................................... 36
2.2.6 Protocol Specific Functionality and Parameter Settings ............................................................ 39
2.2.6.1 915 MHz EPC Class 1/1B .......................................................................................................39
2.2.6.2 915 MHz EPC Class 0 ............................................................................................................40
2.3 Examples ............................................................................................................................................. 41
2.3.1 Example 1 ..................................................................................................................................41
2.3.2 Example 2 ..................................................................................................................................41
2.3.3 Example 3 ..................................................................................................................................41
3 Characteristics(Reference) .......................................................................................... 42
3.1 Communications Range ......................................................................................................................42
3.2 Communications Time ......................................................................................................................... 43
APPENDIX : OUTLINE DRAWINGS................................................................................. 44
Reader : ( V740-BA50C02-US)........................................................................................................... 44
Antenna : ( V740-HS02C) ............................................ エラー! ブックマークが定義されていません。
Antenna Cable:.................................................................................................................................... 44
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
1 of 45 ©OMRON CORPORATION 2005
Page 2
V740 Series RFID system
Reader/Writer Antenna
Operation Manual
V740-BA50C04-US
V740-BA50C24-US
V740-HS01L V740-HS01C
The OMRON V740 RFID Reader ( herein after denoted as the V740 Reader) uses RFID (radio frequency identification) technology to read data stored on RFID tags. The V740 reader operates analogous to an SQL (structured query language) server, providing tag data in response to requests from another application. A separate software application may be used to direct its operation and provide a user interface.
Mono-static Reader/Writer(4ports) Mono-static Reader/Writer(8ports) Mono-static Antenna
Mono-static Antenna
FCC WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTICE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Properly shielded a grounded cables and connectors must be used for connection to host computer and / or peripherals in order to meet FCC emission limits. AC adaptor with ferrite core must be used for RF interference suppression.
The reader supports UHF (ultra high frequency) antennas, which are available separately. The reader supports multiple configurations of UHF antenna ports and transfers data to a remote computer over a network connection.
The V740 Reader is powered by ThingMagic LLC Mercury4
® technologies.
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
2 of 45 ©OMRON CORPORATION 2005
Page 3
1. Installation and Usage Guide
About this Guide
This installation and usage guide explains how to install the V740 Reader, how to use the browser­based interface, and how to control the reader remotely.
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
3 of 45 ©OMRON CORPORATION 2005
Page 4
1.1 Before You Begin
1.1.1 Installation Requirements
The reader is shipped with a certified limited power source with a cable length of 1.8m (6ft).
Use only authorized antennas and cables to maintain FCC approval (see page 4).
In order to comply with FCC requirements for RF exposure safety, a separation distance of at least 23 cm (9.1 in) needs to be maintained between the radiating elements of the antenna and the bodies of nearby persons.
Provide strain relief for all reader connections.
The minimum screw size for mounting the reader is #12 (M5). Use suitable wall anchors when mounting to drywall or masonry.
A Shielded Ethernet cable must be used to communicate with other devices.
Multiple readers and antennas can be used in combination to enhance detection at specific locations provided the software application is able to synchronize antenna operation.
Recommended minimum configuration for a computer running an application that interfaces with the V740 Reader:
Pentium® 400 MHz processor
– – 128MB memory 10 GB hard disk drive Base-T-10/100 Ethernet® port
1.1.2 Performance Considerations
Reader performance may be affected by external factors including tag variables and environment.
Performance tests conducted under typical operating conditions at your site are recommended to help you optimize system performance.
Tag Variables
There are several variables associated with tags that can affect reader performance:
Application surface — Some materials interfere with tag performance including metal and moisture. Tags applied to items made from or containing these materials may not perform as expected.
Tag orientation — Reader performance is affected by the orientation of the tag in the antenna field.
Tag model — many tag models are available. Each model has its own performance characteristics(refer to Chapter 3).
Environment
Reader performance may be affected by the following:
Metal surfaces such as desks, filing cabinets, bookshelves, and wastebaskets may enhance or degrade reader performance.
Mount antennas as far as possible from metal surfaces that are adversely affecting system performance.
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
Devices that operate at 900 MHz, such as cordless phones and wireless LANs, can interfere with reader performance.
These devices may degrade performance of the reader. The reader may also adversely affect performance of 900 MHz devices.
Antennas operating in close proximity may interfere with one another, thus degrading reader performance.
Interference from other antennas may be eliminated or reduced by using either one or both of the following strategies:
Affected antennas may be synchronized by a
separate user application using a time­multiplexing strategy.
Antenna power can be reduced by reconfiguring
the RF Transmit Power setting for the reader.
4 of 45 ©OMRON CORPORATION 2005
Page 5
1.2 Authorized Antennas
The antenna authorized by the FCC for use with the V740 Reader is described below.
IMPORTANT: No other antennas may be used with the V740 Reader without violating FCC regulations. It is the responsibility of the user to comply with this requirement.
1.2.1 Antennas
OMRON Mono-static Antenna(Options)
Model: V740-HS01L,V740-HS01C Gain: 6 dBi max. Connector: N Cable length : 0.3m(0.98’)
1.2.2 Antenna Cables(Options)
The only cables authorized by the FCC for use with the V740 Reader are listed below:
Short cable
Model: V740-A01-3.0M Length: 3.0m(9.8') Insertion Loss: 1.5 dB min. Cable Type: 3D-2V Connector: Reverse TNC to Type N Cable Diameter : 5.5mm(0.22’’)
1.2.3 Setting the Reader RF Power
During initial installation, the reader must be properly configured to use the correct RF power to comply with FCC regulations. DO NOT increase the power beyond the recommended power setting as calculated below.
The maximum RF power is determined from antenna gain and antenna cable loss using the formula:
Pmax = 36 dBm - Antenna Gain + Cable Loss
For example, if the antenna has a maximum gain of 6 dBi, and the cable has a minimum loss of 1.5 dB, the maximum RF power that may be set is (36- 6 + 1.5) =
31.5 dBm.
The Reader RF Power is set through the Settings Page as described on Page 14.
Note that in no case may the power be set higher than
32.5 dBm.
Recommended Power Settings
Antenna Type Short Cable/Long Cable
V740-HS01L
V740-HS01C
31.5 dBm
Long cable
Model: V740-A01-10M Length: 10m(32.8') Insertion Loss: 1.5 dB min. Cable Type:5D-SFA Connector: Reverse TNC to Type N Cable Diameter : 7.6mm(0.30’’)
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
5 of 45 ©OMRON CORPORATION 2005
Page 6
Mechanical Loading - Mounting of the equipment in
1.3 Reader Installation
The following parts are provided with the reader:
the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.
Part Qty. Part Number
V740-Reader/Writer 1
Power Supply 1 -
V740-BA50C04-US or V740-BA50C24-US
IMPORTANT: Be sure the user reads the section on Declarations to maintain compliance with FCC regulations. The Reader and the antennas are to be installed only by professionals at specific locations For human safety maintain a 23 cm (9.1in) distance from the antennas .
1.3.2 Install the Antennas
The antennas can be mounted directly to a variety of surfaces. Mounting surfaces should be flat to fix the antenna securely.
To mount the reader on a wall :
1. Hold the antenna in its mounting location and mark the position of the mounting screws with minimum (4) points. The antenna has several mounting holes for each side. Choose 4 of those with diagonal position according to the mounting
1.3.1 Install the Reader
You can place the reader on a shelf or mount it to a wall. Mounting shelf and wall should be flat to fix the reader securely.
To mount the reader on a wall:
1. Hold the reader in its two mounting location and mark the position of the mounting screws
location.
2. Drill holes for the screws and install wall anchors if required.
3. Insert the M4x20 screws with spring washers and flat washers and tighten until almost flush with the wall.
Mounting
holes
2. Drill holes for the screws and install wall anchors if required. Be sure anchors must have enough strength to fixed the reader against vibration.
3. Insert the M5x16 screws with spring washers and flat washers and tighten until almost flush with the wall.
4. Slip the reader over the screws and slide down to lock the screws in the keyhole openings.
5. Tighten the screws securely.
6. Fix the AC adaptor so that not to move by vibration and tense DC plug cables. Do not bundle the adaptor cable with other signal or power lines.
4. Tighten the screws securely.
Note: For best performance, mount the antenna in the horizontal orientation as pictured above.
1.3.3 Connect the Reader
A B C D E A = RJ-45 Ethernet port 10/100Base-T B = Safe Mode button C = RS232C (Reserved for future use) D = GPIO E = DC power input
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
6 of 45 ©OMRON CORPORATION 2005
Page 7
A
(
)
(
One to four OMRON Bi-static antennas(V740-HS02C) can be connected to the reader, depending on the application requirements. The upper row silk-screen markings on the reader identifies the port number and antenna connections.
Note: Lower row of silk-screen marking on the reader is reserved for future use.
1. Connect required UHF antennas to the antenna ports on the reader .
IMPORTANT: Connect antennas to the antenna ports before applying power to the reader. Any antenna port not having an antenna connected to it will be disabled when the reader is powered on.
Antenna Connection : V740-BA50C04-US
Antenna x2
-
-
Antenna Connections : V740-BA50C24-US
ntenna x4
-
Antenna Cable x8
V740-A01
Note: When two antenna configuration, there are possibility to read the tag by not activated antenna when the tag is located proximately (within 20cm).
2. Verify that all antennas are securely connected.
3. Connect the reader to the network by plugging a Shielded Ethernet cable into the Ethernet port.
or
Connect the reader to a PC (personal computer) by plugging a crossover Shielded Ethernet cable into the Ethernet port.
Note: If DHCP is to be used, then the network and server must be connected before powering up the reader. If a DHCP server is not found the reader will fall back to the IP address: “10.0.0.101”.
-
Note: If NTP is to be used, then the network must be connected and the server must be available
before powering up the reader. If a NTP server is
Antenna Cable x4
V740-A01)
not found. The reader will not set the current time.
4. Plug the power adapter provided with the reader into the DC power input connector. Then connect the power cord to a power outlet.
While the reader is powering up, one green light will be on. After the reader finishes its power-on self-test, approximately 45 seconds, the green light will pulse. The reader is now ready for operation.
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
7 of 45 ©OMRON CORPORATION 2005
Page 8
LED Indicators
Name Meaning
POWER
MODULE A
MODULE B
FAULT/ERROR
STATUS
ACTIVITY
Lights while booting. Blinks when the reader is running.
Lights when communicating with tags via MODULE A(Antenna port 1 and 2) Lights when communicating with tags via MODULE B(Antenna port 3 and 4)
Lights when system error occurs.
Reserved for Future Use
Reserved for Future Use
IMPORTANT: DO NOT disconnect power during startup. Disconnecting power while booting the V740 reader may result in improper startup.
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
8 of 45 ©OMRON CORPORATION 2005
Page 9
6. If you wish to use DHCP, modify the “Use
1.4 Reader Configuration
In some cases, the application software may provide support for reader configuration. If so, follow the instructions provided with the application.
The following procedure describes how to configure the reader directly from a network PC using the browser-based interface.
The reader is shipped to use DHCP by default but will fall back to the following static network configuration if it does not get a DHCP lease:
IP Address: 10.0.0.101 Subnet Mask: 255.255.255.0 Gateway: 10.0.0.1
You must know the IP address and subnet mask settings for the network environment in which the reader will be running or you may use Apple’s Rendezvous™ protocol (download Rendezvous™ from Apple’s website) to browse to it. Also if DHCP and the DNS function are available on the server such as Microsoft system, it can tell you an IP address and a hostname.
Note: Please contact Apple about operating the Rendezvous™ technology.
1. Exit any reader applications that are running on the network.
IMPORTANT: Running another reader application while using the browser-based interface may cause a reader error. If this happens, reboot the reader or restart the system using the browser­based interface.
2. Verify that the reader is operational. All LED’s should be out except for the green power LED which should be pulsing.
3. Start a Java-enabled web browser from any network-enabled PC. This PC must be configured with an IP address and subnet mask compatible with the reader’s settings. For example:
IP address 10.0.0.10 Subnet mask 255.255.255.0
® Windows® 2000 server operating
DHCP?” setting by selecting the “Yes” radio button; otherwise, enter the required network settings in the IP Address, Subnet Mask, and Gateway fields. The fields will turn red if the gateway is not on the same subnet as the IP address. Then, click the [Save Changes] button.
IMPORTANT: Do not disconnect power until the save process is completed.
7. Set the reader RF power per instructions on page 5 to correspond to antenna and cable types.
8. Verify that the settings shown are correct. Then, restart the reader by disconnecting the power cable and then reconnecting it.
It may take about 60 seconds for the reader to restart. If the reader IP address was changed, you must type the new address into the PC browser address field to communicate with the reader.
IMPORTANT: Do not disconnect and connect power cable at the DC cord. Always disconnect and connect power cable at the AC cord.
9. Once the system restarts, click Settings. You are taken to the Modify Settings page. Your changes will be saved and then applied. After the reader reconfigures its network interfaces, it will automatically redirect you to its status page. There is no need to restart the reader.
IMPORTANT: Do not disconnect power while the reader is saving its new configuration.
The reader is now ready to receive commands from the network.
10. Use the Query page of the browser-based interface to verify the reader and antenna operation by reading tags.
11. Close the browser window. Start an application to control the reader on the network.
4. Browse to…
http://mercury4 (dhcp name) or
http://10.0.0.101
The V740 Reader browser-based interface to the reader is displayed.
5. Click the Settings link in the navigation menu. The Modify Settings page appears.
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
9 of 45 ©OMRON CORPORATION 2005
Page 10
1.5 Reader Service
Navigation menu
1.5.1 Using the Browser-Based
Interface
The browser-based interface communicates directly with the V740 reader. It includes several tools that enable you to monitor reader performance, change reader settings, and upgrade reader firmware.
A navigation menu provides access to the following pages:
Status—Displays current operational settings.
Query—Allows the user to set timing of operation, set antennas, set RF air interface protocols, and read tags.
Write—Allows the user to write tags; this is only applicable to tags that are writeable.
Settings—Allows the user to modify radio and network settings.
Description for each page are the following:
Firmware—Allows the user to upgrade the V740 reader with new firmware images supplied by OMRON.
Restart—Allows the user to restart the reader.
Diagnostics—Provides the current operating settings of the reader.
Help—Provides information that is helpful in operating the reader.
The browser-based interface can be run from any PC on the network. Care must be taken to configure the PC with an IP address and subnet mask compatible with the current operational settings of the reader.
To start the browser-based interface:
1. Exit all reader applications on the network.
IMPORTANT: Running another reader application while using the browser-based interface may cause a reader error. If this happens, reboot the reader or restart it using the browser-based interface.
2. Start a Java-enabled web browser from any network-enabled PC.
3. Type the IP address of the reader to which you want to communicate in the address field of the browser or use Apple’s Rendezvous™ protocol to browse to it.
4. A navigation menu and the V740 Reader “Mercury4” Status page appear in the browser.
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
10 of 45 ©OMRON CORPORATION 2005
Page 11
Status Page Query Page
The Status page shows the current settings of the reader.
1. Click the Status link in the navigation menu to display the Status page.
2. Close the browser window if you are finished using the browser-based interface.
Note: The status of 'Connected Antenna Ports' is displayed as 'Connected' only for the antennas connected to the V740 reader when it starts up.
Use the Query page to monitor reader performance (read rags). The Query page is useful for verifying performance when installation is complete and for troubleshooting performance issues.
The Query field includes a drop-down list (at the bottom-right of the screen) that enables you to specify the operating mode. The operating mode specifies the tag protocols and the maximum number of tags count to be used in conjunction with the Query page.
Note: The selected settings DO NOT affect reader performance associated with other applications.
The following operating modes are available for use with the Query page:
Each mode provides the most suitable time out value for the protocols and the number of tags to be read.
less than 10 EPC0 tags
less than 10 EPC1 tags
less than 20 total EPC0 and EPC1 tags
less than 50 EPC0 tags
less than 50 EPC1 tags
less than 100 total EPC0 and EPC1 tags
less than 100 EPC0 tags
less than 100 EPC1 tags
less than 200 total EPC0 and EPC1 tags
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
Note: The modes that contains ISO18000-6B are not supported in the firmware version 2.0.61.To confirm the version of the firmware see the status page.
11 of 45 ©OMRON CORPORATION 2005
Page 12
To read Tag data;
1. Click the Query link on the navigation menu. The Query page appears.
2. Select the operating mode from the pull-down list.
3. Click the Start button to begin reading tags.
If there are tags, tag data is displayed. Each entry shows sequential tag number, number of times tag was read, tag data, antenna, and protocol.
4. Click Stop to stop the tag search.
IMPORTANT: You MUST stop the query before changing the operating mode or RQL command. If you do not click STOP before exiting the browser­based interface, the reader will continue to poll antennas.
Show Raw button displays raw tag data on the
Query page. Each entry shows read count, protocol, antenna, and tag data.
Hide Raw button stops the display of raw tag data.
Font Size text box decides the character size of tags read list.It can be applied from 1 to 128.
Clear Output button clears the tags read list displayed.
Query Once button initiates a single search cycle.
Note: The SELECT clause may be modified.
However changing the SELECT clause may cause incorrect display of data.
The Query page provides additional options that enable you to control the data that is gathered and how it is displayed:
Bignum checkbox (when checked) displays the
total number of unique tags read. The total is displayed in large red numbers directly over the tags read list.This function is not available when Show Raw screen is displayed.
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
12 of 45 ©OMRON CORPORATION 2005
Page 13
Write Page
To write data, use the Write page to replace the EPC data that is encoded on a 915 MHz EPC Class 1 tag.
Consider the following guidelines when writing to tags:
Always place a tag 0.3–0.6m (1–2ft) from the antenna when writing data. The tag may be damaged if it is too close to the antenna.
Only unlocked 915 MHz EPC Class1/1B tags can be used.
The data to be written must be exactly 16 or 24 hexadecimal characters (numerals from 0–9 and letters from A–F)(16 characters for 64 bit tag, 24 characters for 96 bit tag).
To read data from a tag:
1. Display the Write page (click the Write link on the navigation menu).
2. Click the Make Select button. A query designed to read data from the antenna connected to the port 1 appears in the center window.
3. Place the tag to be read within the detection zone of the antenna.
4. Click the Submit Query button to read tag data. Query results appear in the bottom window.
Always place only one tag in the antenna’s field when writing. If multiple tags are present, they will all be encoded with the same EPC data.
Use the antenna connected to port 1 of the reader
To write data to a tag:
1. Click the Write link on the navigation menu. The Write page appears.
2. Type tag ID data in the upper window, type 16 hexadecimal digits for 64bits class 1 tag, or type 24 hexadecimal digits for 96bit class 1B tag.
3. Highlight the hexadecimal data.
4. Click the Make Update button. A query designed to write the highlighted data to the tag appears in the center window.
5. Place the tag 0.3–0.6m (1–2ft) from the antenna connected to the port 1.
Verify that no other tags are in the antenna’s field.
6. Click the Submit Query button to write the data. If the write was successful, the command line and the new tag data appears in the bottom window. If the write is not successful, the response will include an error message.
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
13 of 45 ©OMRON CORPORATION 2005
Page 14
Settings Page
Use the Modify Settings page to change network settings.
to connect to the reader via its hostname. Usually when using DHCP, the DHCP server will add the hostname to the DNS server’s database.
The reader adjusts time by NTP only once when it starts up.You should confirm if the time is correct using Get information command(Ref. Section
2.2.4.4).
Note: Please ask the network administrator about the network settings in your environment.
1. Click the Settings link on the navigation menu. The Modify Settings page appears.
2. Enter the required settings.
3. Click the Save Changes button to save the new settings.
IMPORTANT: Do not disconnect power until the save process is complete.
The new settings DO NOT take effect until the reader is restarted by rebooting the reader (see 1.5.2 Restarting the Reader on page 15).
Instructions for Modifying the Settings
Changing these parameters changes the readers settings used on startup. Both radio settings and network settings can be modified. Care must be taken to use correct values or you might be unable to connect the reader without restarting into safe mode.
Static network settings are ignored when in DHCP mode, and DHCP related settings are ignored when in static IP mode. Please note that your network needs to have properly configured DNS servers if you wish
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
14 of 45 ©OMRON CORPORATION 2005
Page 15
Device and LAN settings
Item Describe Setting
Default
Requirement
Device Settings
UHF Power (dBm)
Class 1 96-bit Support
Hostname Specify a name that is unique on the network for the
NTP Server Specify the IP address (or machine name) of the server to
Domain Name Specify the group name when using devices on the network
Primary DNS Server
Secondary DNS Server
Default Gateway Select whether the reader uses LAN wired or air interface. - LAN(fixed)
UHF Output power in dBm. This setting must be adjusted carefully to comply with FCC regulations.
Radio button that enables 96-bit tag support. To optimize the reader keep this setting turned off unless it is needed.
reader.
get current time from the network (either LAN or WAN). The reader obtains correct time from another device since it doesn't have a hardware clock.
Example) 129.6.15.8(NIST, Gaithersburg, Maryland)
as a group. Omit unless using devices as a group.
Specify the IP address (or machine name) of the server that replaces a domain name with an IP address on the network. It is used at first, the secondary DNS server is used next. Omit if you access by the static IP address.
Specify the IP address (or machine name) of the server that replaces a domain name with an ID address.The server is used only when the primary DNS server can not find the domain name. Omit if you access by the static IP address.
Mandatory 30.0
- ON
Mandatory mercury4
Optional (none)
Optional (none)
Optional 10.0.0.1
Optional (none)
LAN TCP/IP Settings
Use DHCP Select whether the reader gets an IP address on the
network automatically by DHCP or manual setting. You must not check the item if you use a manually set IP address.
Vendor Class Identifier
Use DHCP Server Supplied Hostname
LAN IP Address Specify a unique IP address on the network when manually
LAN Netmask Specify the mask value to determine the network address
LAN Gateway Specify a unique IP address for the gateway machine only
Specify an extra DHCP parameter for integration and customization. It is not supported on the firmware version
2.0.61.
Set this to yes to allow the DHCP server to assign the reader a hostname.
set. It is given automatically by the DHCP server, if using DHCP.
of the subnet from the IP address. It is not used if using DHCP.
when communicating with the device on another LAN. You don't have to set the item when communicating with the device on the same LAN. Also It is not used if using DHCP.
Optional Yes
Optional mercury4
- No
Mandatory (in the case of not using DHCP)
Mandatory (in the case of not using DHCP)
Optional (in the case of not using DHCP)
10.0.0.101
255.255.255.0
10.0.0.1
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
15 of 45 ©OMRON CORPORATION 2005
Page 16
Firmware Upgrade Page
Use the Firmware upgrade page to update firmware. Only the update firmware file provided by OMRON can be used.
1. Click the Firmware link on the navigation menu. The Firmware upgrade page appears.
2. Place the cursor in the Filename field and type the complete network pathname of the firmware file or click the Browse button to locate the new firmware file.
3. Be sure to click both check boxes if you want the reader to revert to safe-mode settings(Ref. section
1.5.3.).
The lower check box becomes enabled after clicking the check box above.
Restart Page
Use the Restart page to restart the reader.
1. Click the Restart link on the navigation menu. The Restart Reader page appears.
2. To restart the reader, click the Restart System button. The following dialog box appears.
3. Click OK. The following message appears and remains on the screen until the reader restarts. Then the Status page appears.
4. Click the Upgrade button to download the new firmware to the reader.
The status frame at the bottom of the page displays the progress of the upgrade if the web browser supports automatic page reload. Click the Refresh button to update the status bar if the web browser does not support automatic page reload.
The firmware downloaded to the reader IS NOT implemented until the reader is restarted.
If an error occurs during the firmware upgrade, use Safe Mode to recover.
IMPORTANT: DO NOT disconnect power from the reader while the firmware is being updated. You may get unpredictable results.
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
16 of 45 ©OMRON CORPORATION 2005
Page 17
Diagnostics Page
The Diagnostics page provides a wealth of information, including the current settings of the reader, comprehensive version information, and current status of network interfaces.
Help Page
Use the Help page to view descriptions of system operations.
View Log is used for maintenance of the reader.
For use by OMRON only.
V740 RFID READER/WRITER, ANTENNA OPERATION MANUAL
2005-07, REV.01
17 of 45 ©OMRON CORPORATION 2005
Page 18
1.5.2 Restarting the Reader 1.5.3 Using Safe Mode
Use this procedure to recover from a reader error. Use the Safe Mode button on the reader connector
1. Click the restart link on the navigation menu.
2. Click the restart button and the OK button on the confirmation dialog.
Wait for at least 60 seconds for the reader to boot up. The Power/Heartbeat LED is solid green while the reader boots. When the LED begins blinking, the boot process is complete.
panel to recover from errors that disable the reader.
Safe mode operation restores factory default settings as follows:
Firmware Version: ...............factory installed version
Item Default Value
UHF Power 30.0
Class 1 96 -bit Support OFF
Hostname mercury4
NTP Server louie.udel.edu
Domain Name thingmagic.com
Primary DNS Server 10.0.0.1
Secondary DNS Server none
Default Gateway LAN
The browser-based interface pages are displayed in red when operating in Safe mode and the reader function is restricted. Only functions for changing settings are available, functions for tag operation are not available. In most cases, the reader will need to be reconfigured for operation with the reader application after starting in Safe mode.
1. Disconnect power from the reader.
2. Depress and hold the Safe Mode button, using a nonconductive object, while restoring power to the reader. Keep the Safe Mode button depressed until the reader boots completely (the green Power/Heartbeat LED blinks).
Safe Mode button
3. Factory-default settings are restored.
4. Use the browser-based interface to configure the reader for use with your system.
This PC must be configured with an IP address and subnet mask compatible with the reader default settings. For example: IP address
10.0.0.10, net mask 255.255.255.0.
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
18 of 45 ©OMRON CORPORATION 2005
Page 19
5. Click the Settings link on the navigation menu and verify the new settings. Be sure to click [SAVE] to store all settings changes.
6. Restart the reader with the new settings. Once the restart is complete, the reader is no longer in Safe Mode.
A navigation menu provides access to the following pages:
Status—Displays current settings in safe mode.
Settings—Displays current settings in normal mode. And allows the user to modify network settings.
Firmware—This page can be used to upgrade the tag reader with new firmware images supplied by OMRON.
Restart—Allows the user to restart the reader.
Diagnostics—This page provides the current operating settings in safe mode.
Help—This page provides information that is helpful in operating the tag reader.
Note: Enabling Safe-Mode resets all settings to factory default. Modify settings in the normal mode as required for the application.
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
19 of 45 ©OMRON CORPORATION 2005
Page 20
)
(
)
Check Code (CRC)
1.6 Tag Fundamentals
Tag Memory Structure
Protocols and the tag memory structures supported by the V740 reader are described below. For additional information regarding tag operation, refer to each tag specification.
Class 0 Tags
Class 0 tags contain 112 bits of read only memory. It consists of EPC Code and Check Code data. 96 bits of them are EPC Code and the rest 16 bits are Check Code data for the EPC Code.
Byte Bit
1 0-7 2 8-15 3 16-23 4 24-31 5 32-39 6 40-47 7 48-55 8 56-63
9 64-71 10 72-79 11 80-87 12 88-95 13 96-103 14 104-111
Contents
EPC Code
12bytes (96bits)
Check Code
CRC
Class 1B Tags
Class 1B tags contain 128 bits of programmable memory. The format is almost the same as the Class 1 tags. Bit count of EPC code is 96.
Byte Bit
1 0-7 2 8-15 3 16-23 4 24-31 5 32-39 6 40-47 7 48-55 8 56-63
9 64-71 10 72-79 11 80-87 12 88-95 13 96-103 14 104-111
Contents
Check Code (CRC
EPC Code
12bytes (96bits)
Class 1 Tags
Class 1 tags contain 96 bits of programmable memory. It consists of EPC Code, Check Code data. 64 bits of them are EPC Code, and the first 16 bits of them are Check Code for the EPC Code.
Byte Bit
1 0-7 2 8-15 3 16-23 4 24-31 5 32-39 6 40-47 7 48-55 8 56-63 9 64-71
10 72-79
Contents
EPC Code
8bytes (64bits)
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
20 of 45 ©OMRON CORPORATION 2005
Page 21
Supported Tag Protocols
1.7 Specifications
Electrical
Reader
UHF operating frequency ................... 902–928MHz
Input voltage.........................................24Vdc, 2.0A
Separate Power Supply
Input voltage.......... Nominal 100–240Vac, 50/60Hz
AC line current...................... Nominal 1.6A at 115V
Output voltage ...............Nominal 24Vdc, 2.5A peak
Certified limited power source
Antenna
Operating frequency........................... 902–928MHz
Gain......................................................... 6dBi max.
V.S.W.R....................................................... < 1.5 :1
Polarization......................................... Liner/Circular
Impedance.....................................................50ohm
Cable length ......................................... 30cm(11.8’)
915 MHz......................................... EPC Class 1/1B
Environmental
Reader
Operating temperature: ... 0° to 40°C (32° to 104°F)
Storage temperature: ....-20° to 65°C (-4° to 149°F)
Relative humidity: .... 25 to 85%RH non-condensing
Antenna
Operating temperature: -10° to 55°C (14° to 122°F) Storage temperature: ..-25° to 65°C (-13° to 149°F)
Relative humidity: .... 25 to 85%RH non-condensing
Mechanical
Reader
Dimension .................................308 X 286 X 40mm
Weight ...............................................1.5kg (3.4 lbs)
Protection .........................................................IP40
Antenna
Dimension ..................................256X 256 X 57mm
Weight ...............................................1.5kg (3.4 lbs)
Protection .........................................................IP50
Outline Drawings
See on the page 43 to 44.
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
21 of 45 ©OMRON CORPORATION 2005
Page 22
2. Query Protocol
Reference Guide
This chapter lays the groundwork for the communication protocol between client software running on a remote computer and the V740 Reader. The client software may be a database system, enterprise software, or user software.
In this chapter, we discuss the underlying transport protocol used and present the initial communication protocol RQL. This protocol is loosely based on the SQL language with extensions for a better notion of time. This protocol was designed for rapid prototyping of applications, where a full query to the reader can be encapsulated in a single line of ASCII text. A simple polling mechanism exists for automatically receiving tag events and for testing.
2.1 Transport Protocol
In the current implementation, TCP/IP is used as the transport protocol. TCP is a connection-oriented protocol that provides a reliable, in-order data transport layer with end-to-end checksums and flow control.
2.1.1 TCP Connection Setup and Teardown
A session between client software and the reader consists of connection setup, data transactions, and connection teardown.
At present, all connections are initiated only by the client software. If, for example, the reader is configured to automatically forward events and/or data to the client software but the client software has not established a connection, then no attempt is made by the reader to contact the client software to establish a connection. Furthermore, if an extant connection terminates unexpectedly, the reader will not attempt to contact the client software to re-establish a connection. All responsibility for opening, maintaining, and closing the connection during a session rests with client software.
The client software sets up a TCP socket connection on reader port 8080. After connecting successfully, communication between the client software and the reader can proceed as described below. Once the client software has determined that communication has concluded, the connection must be terminated at the TCP level. In order to prevent synchronization issues, each reader will support only one TCP connection.
Other transport protocols may be used to communicate between the client software and its subjugate readers. The application-level protocol discussed below is neutral with respect to the transport layer.
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
22 of 45 ©OMRON CORPORATION 2005
Page 23
2.2 Event/Query Protocol
The client software can control the reader using RQL via TCP connection and can acquire data from the readers in two modes: 1) by requesting specific data or 2) by automatically receiving events. The two modes are discussed in further detail in the following subsections.
In order to keep the protocol comprehensive and easy to use, we specify a small set of commands that allow the client software to fully configure the readers and exploit their capabilities.
This minimal set of commands includes the ability to request reads based on several relevant criteria (for example, group reads, range reads, reads by prefix, and so on). The ability to reset the reader database and other control capabilities are also provided.
1. Query
protocol_id
antenna_id read_count
2. Tag population/general query is made
id protocol
0x1234 EPC1 2 1
Client PC
3. Reply
id
0x1234 EPC1 2 1
V740 Reader/Writer
RQL Engine
antenna
id
id
0xABCD EPC0 1 2
read
count
2.2.1 Client Software Requests/Functionality
The client software is able to make the following requests of a reader:
Read IDs of all tags within range of all antennas.
Read IDs of all tags within range of a given
antenna.
Read IDs of all tags within a certain subset of tag
IDs within range of all antennas.
Read IDs of all tags within a certain subset of tag
IDs within range of a specific antenna.
Read Individual tag IDs within range of a certain
antenna or all antennas.
Read only the IDs of tags communicating a given
RF communication protocol.
Return the number of times a given tag was read
per query.
Read IDs from a variety of tag protocols Write IDs to a tag from a variety protocols as they
are supported.
Register any commands as aliases (cursor) to the
V740 reader.
Execute any aliases (cursor) one time
Execute any aliases (cursor) repeatedly at the
indicated interval.
Execute any aliases (cursor) repeatedly in the
specified term.
Figure 1 : Conceptual diagram of control flow
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
23 of 45 ©OMRON CORPORATION 2005
Page 24
2.2.2 General Observations, Commands, and Syntax
We note that a reader behaves very much like database wherein each individual tag represents an entry in the database with a given set of attributes. Due to memory constraints of the reader, the system will remove entries from the database as they are queried.
The syntax for querying against this database is derived from SQL syntax.
In the simplest case, the client software explicitly requests data by polling the readers. The request protocol is implemented in such a way that the client software specifies:
Required information.
What subset of tags the reader should consider.
Which read constraints should be applied.
Example commands:
SELECT id FROM tag_id WHERE
id=0x1234567890ABCDEF AND antenna_id=1 AND protocol_id='EPC1';
Would return a tag only if its tag ID was
0x1234567890ABCDEF.
SELECT id FROM tag_id WHERE (antenna_id=1
OR antenna_id=2) AND protocol_id='EPC1' SET time_out=1000;
Would return a tag only if the antenna ID was 1 or 2 and will search for at least 1000ms.
Note: The RQL command is terminated by a semicolon. When you use sample commands in this manual, you must input a command in one line without line feed characters.
2.2.3 Extended RQL Command
Structure supported by the V740
Reader
Extended Command Set for Data and Write, and Lock operations
ID Read : Identify tags, including anti-collision.
ID Write : Change tag ID
ID Lock : Prevent further changes of tag ID
Kill : Initialize tag
Password : Set a pass-code to kill a tag
Table1: Supported Protocols for each function
Function EPC1 EPC1B EPC0
Read
ID
Write
Lock
Kill
Password
N/S:Not Supported in firmware Ver.2.0.61 N/A:Not Applicable
With the exception of the ‘ID Read’ command, all commands are protocol and antenna specific and can only be used with a single protocol at a time and with a single antenna at a time. Hence all queries with the exception ‘ID Read’ need to be constrained to one protocol and one antenna, for example
WHERE protocol_id='EPC1' and antenna_id=1
A complete example of an ‘ID Write’ query would be
UPDATE tag_id SET id=0x0123456789ABCDEF WHERE protocol_id='EPC1' AND antenna_id=1.
‘ID Read’ (enumerate tags) is, by definition, a multi­target command, since it determines what the individual targets are in the first place.
N/A
N/S N/S N/A
N/S N/S N/A
N/S N/S N/A
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
There are some special cases to the single-target rule. For example, ID Write is semantically tricky – what does it mean to target a tag if its target ID is going to be changing? In the current state of the art, most protocols do not support addressed ID writes (ID write targets all tag IDs) or disallow tag ID changes entirely.
24 of 45 ©OMRON CORPORATION 2005
Page 25
2.2.4 Detailed Command Structure
2.2.4.1 ID Read
The client software would use the SELECT command to read IDs of tags. The SELECT command is for querying the tag population of the reader as well as static variables such as firmware version. The structure of a SELECT command is as follows:
SELECT entry_list FROM
table_expression where_specification
[set_specification];
Ref. Table 2 for entry_list details.
A SELECT clause is entered as:
SELECT entry1, entry2, entry3, ...
one or more entries can be specified, for multiple entries, a comma delimiter is required.
A table_expression is specified by only one table name.
FROM table
In the function ID Read, you always use 'tag_id' as a table name. And so the table_expression is as follows:
From tag_id
A where_specification is entered as:
WHERE boolean_expr
boolean_expr can consist of any expression which evaluates to a boolean value. In many cases, this expression will be:
entry binary_operator value
where binary_operator can be one of =, <, <=, >, >= , <>, AND, or OR. Parentheses may also be used to create associations of subexpressions. In the presence of a 'where_specification', SELECT will not return any rows for which the WHERE condition does not evaluate to TRUE.
Note: You must specify one or more protocols in 'where_specification'.
A set_specification is entered as:
SET expression
expression consists of entry and the value.
In response, all IDs delimitted by LF code are sent. The format is as follows:
[id1] <LF> [id2] <LF>.....[idn] <LF><LF>
The response includes the check code and ID. The first 4 digits are the check code, and the ID follows for the EPC1/1B protocols. For EPC0, the 24 digits ID is first, followed by the 4 digit check code.
Below are some examples for reading tag ID:
To query a tag on a specific antenna and protocol,
you can specify a specific antenna and protocol in the 'where_specification':
SELECT id FROM tag_id WHERE antenna_id=1 AND protocol_id='EPC1';
SELECT id FROM tag_id WHERE antenna_id=2 AND protocol_id='EPC0';
The first specifies 1 as an antenna id, and EPC1 as a protocol id. The second specifies 2 as an antenna id, and EPC0 as a protocol id. The reader searches tags that corresponds to the condition, and returns the tag ID if the tag is present followed by LF code, an empty event (only LF code) results if tags matching the 'where_specification' are not present.
To query a tag on multiple antennas and
protocols, you can specify multiple antennas and protocols by 'OR' operator in the 'where_specification':
SELECT id FROM tag_id WHERE (antenna_id=1 OR antenna_id=2) AND protocol_id='EPC1';
SELECT id FROM tag_id WHERE antenna_id=2 AND (protocol_id='EPC1' OR protocol_id='EPC0');
The first specifies 2 antennas, and the second specifies 2 protocols.
To query a specific tag, given its EPC code, one
can specify a specific tag with an ID as a hexadecimal number:
SELECT id FROM tag_id WHERE id=0x1234567890ABCDEF AND antenna_id=1 AND protocol_id='EPC1';
When Indicating id in the 'where_specification', the reader searches the ID from the higher order. If the value is shorter than 16 digit for EPC1(24 digit when using EPC1B), it examines only upper bits.
SELECT id FROM tag_id WHERE antenna_id=1 AND protocol_id='EPC1' AND id=0x1234;
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
25 of 45 ©OMRON CORPORATION 2005
Page 26
To query a specific sub class of tags, given a
range of tag ID values:
SELECT id FROM tag_id WHERE protocol_id='EPC1' AND tag_id>=min_tag_id AND tag_id<=max_tag_id;
The reader returns the tag ID values for all the present tags between min_tag_id and max_tag_id, which are hexadecimal values.
To query tags by specific or all antennas:
SELECT id FROM tag_id WHERE antenna_id=1 AND protocol_id='EPC1';
SELECT id FROM tag_id WHERE protocol_id='EPC1';
At the first, the reader searches tags only by antenna 1. Second the reader searches tags by all antennas available. Omitting the antenna indication in the 'where_specification' means to search all antennas available.
Note: When specifying multiple antennas even if an antenna that does not exist is specified, the reader obtains the tag ID only using antenna 1 and doesn't return any an error message.
SELECT id FROM tag_id WHERE (antenna_id=1 OR antenna_id=5) AND protocol_id='EPC1';
The client software can specify multiple entries in
the select_list field of the SELECT command:
SELECT id, antenna_id FROM tag_id WHERE antenna_id=1 AND protocol_id='EPC1';
SELECT protocol_id, timestamp, id, antenna_id FROM tag_id WHERE antenna_id=1 AND protocol_id='EPC1';
The first example returns the tag IDs and antenna_ids, and the second returns protocol_ids and the time that the tag was read (seconds from the unix epoch, Jan 1, 1970) with the tag IDs and antennas_ids.
Note: To read timestamp, the NTP sever must be set up in advance.
The reader returns protocol_id as an integer value. The value '1' represents 'EPC1',and the value '9' represents 'EPC0'. For example, the query with protocol_id and the response is as follows:
[Query] SELECT protocol_id, id FROM
[Res] 1|0xCE791111111111111111<LF><LF>
tag_id WHERE antenna_id=1 AND protocol_id='EPC1';
To query EPC0 tags:
When the client software reads tags of the 'EPC0' protocol, it should indicate 'read_count>1' in the 'where_specification'.
For example, the command is as follows:
SELECT id FROM tag_id WHERE antenna_id=1 AND protocol_id='EPC0' AND read_count>1;
To read EPC1 and EPC0 tags at the same time:
SELECT id FROM tag_id WHERE protocol_id='EPC1' OR (protocol_id='EPC0' AND read_count>1);
Note: If you don't specify the 'read_count>1', the reader returns ghost data occasionally. 'Ghost data' means the data which is returned even if tags do not exist in the antenna field.
To query during a specific time:
SELECT id FROM tag_id WHERE antenna_id=1 AND protocol_id='EPC1' SET time_out=500;
The command imposes a time out constraint of 500ms; i.e., the reader stops reading and returns all collected data after 500ms. The order in which specifying arguments are used is irrelevant. The default timeout is 250ms if none is specified.
It is important to always use a timeout in specifying a query to achieve optimal performance for a given application. Detailed
information will be discussed in the next section
Timeout
The client software can impose a time limit on a read operation, requesting the reader to search only for a limited time (specified in milliseconds). The reader may fail to detect some tags if insufficient time is allocated to the search operation. The time_out is the parameter used for specifying the time allocated for the read operation.
Conveyor
Application
Dock Station
short
long
In general, a large time_out should be used for dock stations (>2000ms), and short time_outs should be used for conveyor belts (<100ms).
SELECT id FROM tag_id SET time_out=1000;
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
26 of 45 ©OMRON CORPORATION 2005
Page 27
(See 3.2 Communications Time)
The constraints on the scheduler in the reader for the time_out are shown below. Time is equally divided among the specified protocols. The reader searches sequentially for each antenna in the time provided for the protocol. When the last antenna completes searching, the reader returns to the first antenna again. Following chart shows an example of time schedule given by the model command as below.
SELECT id FROM tag_id WHERE (protocol_id='protocol1' or protocol_id='protocol2') and (antenna_id=ant1 or antenna_id=ant2);
protocol 1 protocol 2
time_out
ant1 ant2 ant1 ... ant1 ant2 ant1 ...
The antenna arbitration algorithm is optimized to maximize the read rate of all the tags in the field. For EPC0, each antenna will be given 150ms of search time. The time division for each antenna within a protocol is determined automatically by the reader and cannot be specified by the user.
It is important to specify the protocols in the RQL commands, if no protocol is specified, the reader searches for tags using all possible protocols, resulting the slower read rates. When specifying multiple protocols, calculate the minimum time_out value using the following calculation.
minimum time_out = max{# of protocol 1 tags x read time of (1) tag), (# of protocol 2 tags x read time of (1) tag),..} x ( # of protocols) x (# of antennas) (ms)
e.g. if 40 EPC0 tags takes 450 ms (cf. 3.2 Communications Time) and 10 EPC1 tags takes 20 ms per tag on average. With two antennas:
minimum time_out = max{450, 10 x 20} x 2 x 2 = 1800 ms.
As another example, if the goal is to search for EPC1 and EPC0 tags on antennas 1, 2 for 20 strong tags on each protocol. The query specified is;
SELECT read_count, protocol_id,
antenna_id, id FROM tag_id WHERE (antenna_id = 1 OR antenna_id = 2) AND (protocol_id='EPC1' OR protocol_id='EPC0') SET time_out=700;
ant1 ant2 ant1 ... ant1 ant2 ant1
EPC1 EPC0 350 ms 450 ms
time_out
700 ms
EPC0 and EPC1 will each get a 350 ms slot. This will allow all 20 EPC0 tags to be read, but not all EPC1 tags.
If the EPC0 tags are present only on the 2nd antenna, the reader will never arbitrate time to this antenna. A better query would be:
SELECT read_count, protocol_id, antenna_id, id FROM tag_id WHERE (antenna_id = 1 OR antenna_id = 2) AND (protocol_id='EPC1' OR protocol_id='EPC0') SET time_out=1600;
time_out
ant1 ant2 ant1 ... ant1 ant2 ant1 ...
EPC1 EPC0
800 ms 900 ms
1600 ms
Both EPC0 and EPC1 will get 800 ms: each antenna for EPC0 will get 400 ms (above 150ms) should read all 20 EPC0 and 20 EPC1.
Note: It is caused by following reasons that difference between the time_out value actual time required for reading.
1. It spends 20 ms to switch protocols.
2. It is fixed on 150 ms to read EPC0 tag.
The max of the difference can be calculated by summing up the time caused by the reasons. You need consider time lag to avoid mutual interface due to time sharing.
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
27 of 45 ©OMRON CORPORATION 2005
Page 28
Table 2: Table Schema - Tag Read
Keyword Entry Table Arguments Range
SELECT
id tag_id Hex String - 0xFEDCBA0
Example
Value
987654321
antenna_id tag_id Int - 2
protocol_id tag_id Int - 9 ( EPC0),
1 (EPC1/1B)
read_count
tag_id Int - 1
(*1)
timestamp tag_id String - 1101973245.
003590
FROM tag_id - - - -
WHERE
antenna_id tag_id Int [1...4] 1
protocol_id tag_id String 'EPC1' or
'EPC1'
'EPC0'
read_count tag_id Int 1 and over 2
id tag_id Hex String - 0xFEDCBA0
987654321
Comments
Requests the id tag data (tag id) of the tag
Requests the antenna id used to read the tag
Requests the protocol id of the tag
Requests the number of times a tag ID was read
Requests the time M4 read data from the tag.
To get the correct time, you need to adjust the clock by setting NTP server.
The name of the internal tag data table(fixed)
Specifies the antenna used to read a tag
Specifies the protocol used to read a tag.
Must be uppercase.
Specifies the number of times a tag was read
Specifies the tag id to be read.
SET time_out tag_id Int [1...65535] 500
Note(*1): If you specify 'read_count' on 'EPC1' protocol, the reader returns '1' due to the search algorithm.
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
Specifies the amount of time the SELECT command will read tags in milliseconds.
28 of 45 ©OMRON CORPORATION 2005
Page 29
2.2.4.2 ID Write
The UPDATE command is used to write new data to a tag. This can be used to write a new tag_id. The structure of an UPDATE command is as follows:
UPDATE table_expression set_specification where_specification;
table_expression and entries specified in set_specification are provided in Table 3.
A table_expression is specified by only one table name:
UPDATE tag_id
A set_specification is entered as:
SET entry=value
A where_specification is entered as:
WHERE boolean_expr
In a where_specification, both protocol_id and antenna_id must be specified.
The tag_id (tag data) is returned with a check code as follows:
If wrong data is written to the tag, the tag may be unreadable. In this case, write correct tag ID again, after that, the tag would turn to be readable.
EPC0: [id][check_code]<LF><LF>
EPC1:[check_code][tag_id]<LF><LF>
The 'where_specification' is specified in the same manner as the SELECT in the previous section.:
Example : To write tag data(tag_id) a 64-bit EPC
tag:
UPDATE tag_id SET id=0x1234567890ABCDEF WHERE protocol=’EPC1’ AND antenna_id=1;
The reader returns the tag_id if the write operation was successful.For example the response is as follows:
0xCE851234567890ABCDEF<LF><LF>
In this case, “CE85” is the check code. “1234567890ABCDEF” is tag data(tag id).
If the operation is failed, "Error 0102: Error performing query<LF><LF>" returend.
Note: The format of the tag data in the command must much the selected protocol or an error will result.
For example :
- A 64 bit EPC1 tag requires 16 hexadecimal digits
- A 96 bit EPC1 tag requires 24 hexadecimal digits
(See section 1.6)
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
29 of 45 ©OMRON CORPORATION 2005
Page 30
Table3 : Table Schema - Tag Write
Keyword Entry Table Arguments Range Example
Value
UPDATE tag_id - - - -
SET id tag_id Hex String - 0xFEDCB
A0987654 321
WHERE
antenna_id tag_id Int [1...4] 1
protocol_id tag_id String 'EPC1' 'EPC1'
Comments
Tag id data database table(fixed)
Specifies the tag id(tag data) to be written
Specifies the antenna used to read a tag
Specifies the protocol used to read a tag.
Must be uppercase.
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
30 of 45 ©OMRON CORPORATION 2005
Page 31
2.2.4.3 Reader Control
The client software can register a command with a cursor name to the reader. This section describes Cursors(Stored Procedures or Aliases ) and Reader settings.
i. Cursors
Declare
The client software has the ability to declare cursors (saved queries), which it can then use to request data repeatedly using the FETCH or the AUTO_MODE command. Only One cursor can be executed at one time. A maximum of 16 cursors can be defined.
To create a cursor:
DECLARE cursorname CURSOR FOR query;
cursorname — an arbitrary string.
query — an RQL query (SELECT/UPDATE
statement), as defined above.
If the query is valid in its syntax,an empty event (only LF code) is returned. If invalid, an error message is shown(Ref. Table 6).
Example:
DECLARE cursor1 CURSOR FOR SELECT id, antenna_id FROM tag_id WHERE protocol_id='EPC1';
DECLARE cursor2 CURSOR FOR UPDATE tag_data SET id=0xFEDCBA9876543210 WHERE protocol_id='EPC1' and antenna_id=1;
Note: Commands for getting information and setting the separator can not be used as cursors.
Close
To close(delete) a cursor and free its resources(only 16 cursors may be defined simultaneously). Only one cursor can be closed at one time. The client software issues the command:
CLOSE cursorname;
If the cursorname is valid, following the command, an empty event (only LF code) is returned.
daemon to its initial state; that is, resets the reader, deletes cursors used clears memory.
ii. Execution
Commands stored as cursors can be executed in 3 ways as described below.
Fetch
To execute the stored cursor,a FETCH command is sent by the client software. Only one cursor can be executed at one time.
FETCH cursorname;
which performs all actions appropriate to the declared query and sends the result back.
Example:
DECLARE cursor3 CURSOR FOR SELECT id, antenna_id FROM tag_id WHERE id = 0x11111111111111111111 AND protocol_id='EPC1';
FETCH cursor3;
could return:
if the tag was read by antenna 2,
0xCE791111111111111111|2<LF><LF>
or if the tag was not found.
<LF>
Sequence of execution
DECLARE
FETCH
RQL execution
Response
time
Auto Mode
The client software may switch the reader into Auto Mode, causing the reader to repeatedly execute a cursor indefinitely.
SET auto cursorname = ON, repeat = interval;
Reset
To reset the reader RQL server, for example, if the RQL state is undefined or questionable, use:
RESET;
Following the command, an empty event (only LF code) is returned. The command returns the RQL
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
For example,
DECLARE cursor4 CURSOR FOR SELECT id, antenna_id FROM tag_id WHERE protocol_id='EPC1' SET time_out=250;
SET auto cursor4 = ON, repeat = 500;
Every 500 milliseconds, the cursor executes for 250milliseconds querying for tags. The remaining 250
31 of 45 ©OMRON CORPORATION 2005
Page 32
A
A
milliseconds are spent with cursor idle(RF off). This syntax can be used for controlling the duty cycle of the reader. For full reader utilization, ensure that the value of time_out is less than the value of repeat, if not the cursor is executed continuously.
Auto Mode can be terminated by sending the command:
SET auto = OFF;
No other command can be used while Auto Mode is active.
To schedule intermittent reads with off times of 1 second starting at a specific time use:
Example:
DECLARE cursor5 CURSOR FOR SELECT id FROM tag_id WHERE protocol_id='EPC1' SET time_out=500;
SET auto cursor5 = ON, repeat = 1000; (get resopnses...) SET auto = OFF;
DECLARE
UTO ON
RQL execution
UTO OFF
Response
repeat
repeat
time
Scheduled Reads
The reader uses the Network Time Protocol as a means to establish absolute time on the reader. With that capability in place the reader is enabled to execute tag operations that have been scheduled relative to absolute time. The reader adjusts UTC time of the NTP server, whatever time zone it works on. Here is how it works.
The first form here starts the auto mode at a given time, and then just continues until you stop it, the same way you would stop normal auto mode.
The second form runs during the specified interval.
The start and stop time are specified in ISO8601 time strings, of the form
YYYY-MM-DDTHH:mm:SS.DDDDZZZZZ
Where YYYY is the year, MM is the month, DD is the day, HH is the hour, mm is the minute, SS is the second, and DDDD is the fraction of a second, and ZZZZZ is the time zone. The seconds and fractions of a second are both optional (but if you want fractions of a second, you must specify seconds as well). The time zone can either be specified as GMT or Zulu time by using a 'Z' or it can be an offset from GMT using +HH:MM or -HH:MM. For example, in Eastern time, that would be -05:00.
Some examples:
C6: DECLARE cursor6 CURSOR FOR SELECT id
FROM tag_id WHERE antenna_id=1 AND protocol_id='EPC1';
C7: DECLARE cursor7 CURSOR FOR SELECT id
FROM tag_id WHERE antenna_id=2 AND protocol_id='EPC1';
To run c6 once on February 14th 2004 at 18:54:50 GMT:
SET trigger_time cursor6 = '2004­02-14T18:54:50Z';
To run c7 for 10 seconds starting in intervals of 1000 ms at 2004-01-20 at 15:37 in Eastern Standard Time:
SET auto_time cursor7 = '2004-01­20T15:37-05:00/2004-01-20T15:37:10­05:00', repeat=2000;
Note: If only the start time is specified, and the current time has passed the start time, the cursor is executed immediately.
First the user declares a cursor , in a way similar to how to you use cursors in auto mode.
To run the query once at a specific time you use a command of the form:
SET trigger_time cursorname = 'starttime';
To run the query in auto mode over a given interval:
SET auto_time cursorname = 'starttime', repeat=interval;
or
SET auto_time cursorname = 'starttime/stoptime', repeat=interval;
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
32 of 45 ©OMRON CORPORATION 2005
Page 33
If the current time has passed the start time and the stop time specified in the future, the cursor is executed immediately and finished at the specified stop time.
Example:
The following example schedules reads to execute 1 time per second with an off time of 750ms, starting at a specific time:
DECLARE cursor8 CURSOR FOR SELECT id FROM tag_id WHERE protocol_id='EPC1';
DECLARE
SET auto_time cursor8 = '2004-01­22T12:43:08-05:00', repeat=1000;
SET auto_time
RQL execution
start time
Response
repeat
repeat
(stop time)
time
iii. Setting
Separator
The client software can change the separator between the entries of the response for ID reading.(Ref. 2.2.4.1 ID Read).
SET separator = 'c';
Following the command, an empty event (only LF code) is returned. The default separator is '|'. The separator must be one character. Example is as follows:
SET separator='#'; SELECT id, protocol_id, antenna_id FROM
tag_id WHERE protocol_id='EPC1';
The response would be as follows.
0xCE85123467890ABCDEF#1#1<LF><LF>
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
33 of 45 ©OMRON CORPORATION 2005
Page 34
Table4 : Table Schema - Reader Control
Keyword Entry Table Arguments Range Example
Value
DECLARE - n/a cursorname,
- cursor1
query
FETCH - n/a cursorname - cursor1
CLOSE - n/a cursorname - cursor1
RESET - n/a - - -
SET
tirgger_time n/a cursorname,
- -
time
auto_time n/a cursorname,
- -
start time,
stop time
auto n/a cursorname,
- cursor1 = ON
ON, OFF
repeat n/a Integer - -
separator n/a character except
‘|’
';'
Comments
Defines the cursor name for the query.
Executes a cursor and sends the data
Deletes a defined cursor
Resets the reader, deletes cursors, clears memory
Set a cursor to run at the specified time once.
Set a cursor to keep running from the start time to the stop time repeatedly.
Turns auto-mode of cursors on/off.
Sets a cursor to keep running
Changes the separator in the output format of a query.
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
34 of 45 ©OMRON CORPORATION 2005
Page 35
2.2.4.4 Get Information
The client software can get the information about the status of the reader. For example, firmware version and current time of the system. To get firmware version information,The format is as follows:
SELECT entry FROM table_expression
Table5 : Table Schema - Get Information
Keyword Entry Table Arguments Range Example
Value
SELECT
version Firmware String - 2.0.61 (2005-
01­06T16:40:12­05:00)
current_time Settings String - 2005-01-
01T00:01:39.8 91808
FROM
Firmware - - - -
Settings - - - -
Comments
Requests the firmware version of the reader
Requests the current time of the reader.
Table for the information about the reader's firmware.
Table for the information about the reader's settings.
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
35 of 45 ©OMRON CORPORATION 2005
Page 36
2.2.5 Errors
If the reader is unable to execute a command issued by the client software, the reader issues an error message, which has the basic form:
Error error_code : string
where error_code is an integer. Error codes and strings are documented in Table 6.
For example:
DECLARE cursor9 CURSOR FOR SELECT id FROM tag_id;
FETCH cursor10;
Would result in the error message:
Error 0100: Cursor does not exist<LF><LF>
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
36 of 45 ©OMRON CORPORATION 2005
Page 37
Table 6: Error codes and Strings
Error Codes Strings Explanation/Cause
0100 :
ERROR_INVALID _ARGUMENTS
No protocol specified Indicates missing or more than 17
protocol_id are declared(only for UPDATE command)
Too many protocols specified Indicates too many protocols are declared
(only for UPDATE command)
No antenna specified Indicates more than 17 antenna_id or no
antenna are declared (only for UPDATE command)
Too many antennas specified Indicates multiple antennas are
declared(only for UPDATE command)
Unknown table
Cursor already exists Declared cursor name already exists
Unknown setting Indicates no entry item in the table
Cursor does not exist Fetch non-existent cursor
Unknown field Indicates items for GetInfo command (only
for UPDATE command)
Invalid set clause entry
DELETE: Cursor does not exist Indicate a cursor name for CLOSE command
that is not defined by DECLARE command
Start_time not specified correctly Indicate time format incorrectly for start or
finish time.
0101 :
ERROR_INVALID _DATA
0102 :
ERROR_REMOT E
time_out value out of range Set sleep time_out value out of range
Unknown protocol Indicates nonexistent protocol
Syntax Error Syntax error or spelling misstake etc
Invalid argument
Unknown setting
Time is invalid
Unknown protocol ID
Invalid command in current mode Execute a command while another command
is running on auto mode
Error performing query Tag is absent.
argument is illegal.(only for UPDATE command)
Error setting ping threshold
Error setting saved ping threshold
Error setting saved IP address
Error setting saved gateway
Error setting saved netmask
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
37 of 45 ©OMRON CORPORATION 2005
Page 38
0106 :
ERROR_INVALID _ANTENNA
0107 :
ERROR_UNCON NECTED_ANTEN NA
0128: ERROR_UNKNO WN
Error setting firmware version
Error setting safemode version
Error setting OS version
Error setting supported protocols
Error getting operation state
Antenna does not exist in current hardware configuration
Antenna port exists.But no antenna connected
Antenna does not exist in current hardware configuration.
Antenna port exists.But no antenna connected.
Tag data access failed Table name on update command is invalid
Error getting entry
Error getting ip address entry
Error getting netmask entry
Error getting gateway entry
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
38 of 45 ©OMRON CORPORATION 2005
Page 39
2.2.6 Protocol Specific Functionality and Parameter Settings
While the standard ID_read and anti-collision searches are supported by practically all offered protocols, therefore no protocol-specific information is required to issue RQL search. More specific commands, such as data_read and data_write require protocol specific information when formatting the query and interpreting the results. The tables below provide that information.
2.2.6.1 915 MHz EPC Class 1/1B
Parameters / Constraints
Return Value (String)
Example
Class1: 80 bits (64 bits ID and 16 bits
Read ()
CRC, hex format) Class1B: 112 bits
SELECT id FROM tag_id WHERE protocol_id='EPC1';
(96 bits ID and 16 bits CRC)
ID
Write
id: 64 bits or 96 bits (hex)
new_id or error_code with string
UPDATE tag_id SET id=0x1234567890ABCDEF WHERE protocol_id='EPC1' AND antenna_id=1;
- -
Lock N/S
- -
Kill N/S
- -
Password N/S
Note: The state of the tag becomes 'Quiet' after reading by RQL. If you wish to communicate with the tag using a 2nd reader, a ‘Talk’ command must be sent to change the tag to active mode.(for more detailed information about the status of the tag see 'Communication Inferface Specification' for EPC1)
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
39 of 45 ©OMRON CORPORATION 2005
Page 40
2.2.6.2 915 MHz EPC Class 0
Parameters / Constraints
Read ()
ID
Write N/A
Lock N/A
Kill N/A
Password N/A
Return Value (String)
112 bits (96 bits ID and 16 bits CRC)
-
Example
SELECT id FROM tag_id WHERE protocol_id=’EPC0’ AND read_count>1;
-
- -
- -
- -
V740 RFID READER/WRITER, ANTENNA 2005-07, REV.01 OPERATION MANUAL
40 of 45 ©OMRON CORPORATION 2005
Page 41
yer
2.3 Examples
Examples given in this chapter are provided as a guide for the user in determining suitability and does not constitute a warranty. Users must verify operation in their specific environment and application.
2.3.1 Example 1
To read tags attached to cases passed through a gate on a conveyer, the client software finds tags using 2 antennas. For the example pictured below, the command is as follows:
SELECT id, antenna_id FROM tag_id WHERE (antenna_id=1 OR antenna_id=2) AND protocol_id='EPC1' SET time_out=500;
Then the reader continues to read tags through the gate.
antenna 1
tag
conve
cases
antenna 2
2.3.3 Example 3
To synchronize two readers see the following instructions.
On Reader 1:
DECLARE cursor_one CURSOR FOR SELECT id FROM tag_id WHERE protocol_id='EPC1' SET time_out=300;
SET auto_time cursor_one = '2005-02­01T13:00:00Z', repeat=1000;
The first reader will start reading for no less than 300 ms at just 13 o’clock, and it will repeat the command 1000ms.
On Reader 2:
DECLARE cursor_two CURSOR FOR SELECT id FROM tag_id WHERE protocol_id='EPC0' AND read_count>1 SET time_out=300;
SET auto_time cursor_two = '2005-02­01T13:00:00.5Z', repeat = 1000;
The second reader will start reading for no less than 300ms starting at time 0.5 second after 13 o’clock, and it will repeat the command every 1000ms.
The effect will be that each reader will have a almost 50% duty cycle with each one only active when the other one is off.
2.3.2 Example 2
To read tags and send a response repeatedly every 1 second using one antenna. For the example pictured below, the command is as follows:
DECLARE query1 CURSOR FOR SELECT id FROM tag_id WHERE antenna_id=1 AND protocol_id='EPC1' SET time_out=500;
SET AUTO query1=ON, repeat=1000;
antenna 1
Reader 2
Reader 1
Line 1
Line 2
V740 RFID READER/WRITER READER QUERY PROTOCOL 2005-07, REV.01 REFERENCE GUIDE
41 of 45 OMRON CORPORATION 2005
Page 42
Antenna
Y
X
A
Y
X
Y
X
A
<Measurement Set-up>
3 Characteristics(Reference)
Characteristics data given in this chapter is provided as a guide for the user in determining suitability and does not constitute a warranty. Actual performance may vary based on actual user conditions.
3.1 Communications Range
EPC Class 0 : X1020-LBL,Matrics (Dual Dipole)
-200 -150 -100 -50 0 50 100 150 200
EPC Class 1b : V740-D12P01, OMRON
-200 -150 -100 -50 0 50 100 150 200
350
300
250
200
150
100
350
300
250
200
150
100
50
0
ntenna
unit : cm
50
0
ntenna
unit : cm
Tag
*. There are no RF reflection objects around the Antenna and Tag
in the measurement environment.
*. There are some areas where communication is possible outside
the communications range shown in the graph by the effect of
reflection off of the ground. *. Tag attached to styrene resin. *. The UHF power setting of the reader is “31.5” dBm with 3.0m
cable.
V740 RFID READER/WRITER READER QUERY PROTOCOL 2005-07, REV.01 REFERENCE GUIDE
42 of 45 OMRON CORPORATION 2005
Page 43
3.2 Communications Time
Communications time varies for several reasons such as the actual noise environment and the distance between tags and antennas. The chart below shows the communication time vs. the number of tags in the antenna read range. One may use the communication time value as a reference when setting time out values in the RQL command.
Class0 Tags
600
500
(ms)
400
300
Actual communications time
200
0 5 10 15 20 25 30 35 40 45
Class1/1b Tags
900 800 700 600 500
(ms)
400 300 200 100
Actual communications time
0
0 5 10 15 20 25 30 35 40
Number of tags
Number of tags
V740 RFID READER/WRITER READER QUERY PROTOCOL 2005-07, REV.01 REFERENCE GUIDE
43 of 45 OMRON CORPORATION 2005
Page 44
APPENDIX : OUTLINE DRAWINGS
Reader : ( V740-BA50C04-US)
Antenna Cable:
Short cable (V740-A01-3.0M)
Material : Aluminium
V740 RFID READER/WRITER READER QUERY PROTOCOL 2005-07, REV.01 REFERENCE GUIDE
44 of 45 OMRON CORPORATION 2005
Page 45
Long cable ( V740-A01-10M)
V740 RFID READER/WRITER READER QUERY PROTOCOL 2005-07, REV.01 REFERENCE GUIDE
45 of 45 OMRON CORPORATION 2005