Thank you for purchasing a V680-series ID System. This manual describes the functions, performance, and
application methods needed for optimum use of the V680-series RFID System.
Please observe the following items when using the ID System.
• Allow the ID System to be installed and operated only by qualified specialist with a sufficient knowledge of
electrical systems.
•
Read and understand this manual before attempting to use the ID System and use the ID System correctly.
Keep this manual in a safe and accessible location so that it is available for reference when required.
V680-HAM91ID Flag Sensor
V680-HAM81ID Flag Sensor
V680-HS51Antenna
V680-HS52Antenna
V680-HS63Antenna
V680-HS65Antenna
V680-1KP52MTRF Tag
V680-1KP52MT-BT01/-D1KP52M-BT11RF Tag
V680-1KP53MRF Tag
V680-1KP66T/-D1KP66MTRF Tag
V680-1KP66T-SPRF Tag
V680-1KP58HTNRF Tag
V680-2KF52MRF Tag
V680-2KF52MT-BT01/-D2KF52M-BT11RF Tag
V680-2KF67/-D2KF67MRF Tag
V680-8KF67/-D8KF67MRF Tag
V680-D8KF68/-D32KF68RF Tag
User's Manual
Page 4
Introduction
Introduction
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN
ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY , NEGLIGE NCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FO R WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S
ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF
PERSONS, AND SHOULD NOT BE RELIED UP ON AS A SAFETY COMPONENT OR PR OTECTIVE DEVICE FOR SUCH PURPOSES. Please ref er to separate catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine,
system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses
of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
•
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety
•
equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
•
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SE RIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS , AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE
INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data giv e n in this document i s pro vided as a g uide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’ s te st con ditions, and the users must correlate it to actual applicat ion req uire ments . Actual performance is subject to the OMRON Warranty
and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However,
some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your applicat ion on y ou r reque st. P lease consult wit h y our OMR ON repr esentati ve at any time to confirm actual specificatio ns of purcha sed products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for man ufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully chec ked and is believed to be accurate; however, no responsibility is assu med f or clerical, typog raphical ,
or proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible f or the user’s programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission. This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner, for any other purpose. If copying or transmitting thi s
document to another, please co py or transmit it in its entirety.
RFID System
2
User's Manual
Page 5
Introduction
Safety Precautions
zAlert Symbols for Safe Use
The following symbols are used in this manual to indicate precautions that must be observed to ensure safe
use of V680-HAM91, V680-HAM81, V680-series Antennas, and V680-series RF Tags.
The precautions provided here contain important saf ety information. Be sure to observe these precautions.
The following signal words are used in this manual.
Indicates a potentially hazardous situation which, if not avoided, will result in minor or mod-
WARNING
zMeanings of Alert Symbols
erate injury, or may result in serious injury or death. Addition a lly, there may be significant
property damage.
Introduction
Indicates general prohibitions for which there is no specific symbol.
zWarning
WARNING
These Products are not designed to be used either directly or indirectly in applications that detect human
presence for the purpose of maintaining saf ety. Do not use these Products as a sensing means for protect ing
human lives.
RFID System
User's Manual
3
Page 6
Introduction
Introduction
Precautions for Safe Use
Be sure to observe the following precautions to ensure saf e use of the Products.
1. Do not use the Products in environments with flammable, explosive, or corrosive gasses.
2. Do not attempt to disassemble, repair, or modify any Product.
3. Because a cable has a locking mechanism, make sure that it has been locke d before using the cable.
4. Make sure the power supplied by the DC power supply unit is within the rated power supply voltage (24
VDC +10%/−15%) before using the Product.
5. Do not connect the power supply in reverse.
6. Do not allow water or pieces o f wire to ent er from openin gs in the ca se . Doing so may cause fire or electric
shock.
7. Provide sufficient ventilation space.
8. Do not install the Products near any equipment that generates a large amount of heat (such as heaters,
transformers, and large-capacity resistors).
9. Turn OFF the Controller power supply before mounting or removing an Antenna.
10. If an error is detected in any Product, immediately stop operation and turn OFF the power supply. Consult
with an OMRON representative.
11. Dispose of the Products as industrial waste.
12. Do not clean the Products with paint thinner, benzene, acetone, or kerosene.
13. If multiple Antennas are mounted near each other, communications performance may decrease due to
mutual interference. Refer to Mutual Interference between Antennas (Reference) on page 149 and check
to make sure there is no mutual interference between the Antennas.
14. To remove the Unit, catch a tool on the hook and gently remove the Unit.
15. Do not perform wiri ng incorrec tly or sho r t-c ircuit th e load. D oing so may result in r uptur e or dam age from
burning.
16. Do not use the product in environments subject to oil.
17. Do not never use the AC power supply.
RFID System
4
User's Manual
Page 7
Introduction
Precautions for Correct Use
Always observe the following precautions to prevent operation failures, malfunctions, and adverse effects on
performance and equipment.
1. Installation and Storage Environment
Do not use or store the Product in the following locations.
• Locations subject to corrosive gase s, dust, dirt, metal powder, or salt.
• Locations where the specified ambient temperature and ambient humidity range is exceeded.
• Locations subject to extreme temperature changes that may result in condensation.
• Locations where the product would be directly subjected to vibration or shock exceeding specifications.
• Locations subject to contact with water, oil, or chemicals
2. Installation
• The Products communicate with RF Tags using the 13.56-MHz frequency band. Some motors,
inverters, and switching power supplies generate noise that can affect communications with the RF
Tags and cause errors. If such devices are located near the RF Tags, always test operation in
advance to confirm whether the system will be affected.
• Observe the following precautions to minimize the effects of normal noise.
(1) Ground all metal objects in the vicinity of the Products to 100 Ω or less.
(2) Do not use the Products near high-voltage or high-current lines.
• Do not pull on the cables with excessive strength.
• The Product is not waterproof. Do not use it in an environment where mist is present.
• Do not expose the Products to chemicals that adversely affect the Product materials.
• The dust cover is attached at the CN2 connector. When neither writing in the RF Tags nor address
shift function/noise check function is used, the connection to this connector is unnecessary. In this
case, please keep the duct cover attached.
Introduction
3. About control at the initial state
There is a possibility that the state of Input/Output becomes unstable while starting this product.
Please control Input/Output after one second or more passes after turning on the power supply to this
product.
4. Use at high temperatures (V680-D1KP58HTN)
• Data stored in memory in the RF Tag may be lost due to the characteristics of EEPROM, if the accu-
mulated usage time of the RF Tag at a high temperature over 125°C exceeds 10 hours after writing
data to the RF Tag.
• Do not communicate between the Antenna and the RF Tag in an environment where the ambient
operating temperature is 85°C or higher.
An error in communications between the Antenna and the RF Tag may occur.
• Do not use the commands using UID (unique identification n umbe r for each RF Tag) when the RF tag
is used at a high temperature over 125°C. The UID may be lost due to the characteristics of
EEPROM.
For Use at high temperatures, refer to Product Specifications - Use at high temperatures (V680-D1KP58HTN) in Sec-tion 7 Appendices.
p.93
RFID System
User's Manual
5
Page 8
Introduction
Introduction
Meanings of Symbols
Meanings of Symbols
Indicates particularly important points related to a function, including precautions and application advice.
Section 4 Installation, Connections, and Wiring 37
ID Flag Sensor 38
Installing Antennas 43
Installing RF Tags 46
RFID System
User's Manual
7
Page 10
Introduction
Introduction
Section 5 Control I/O Interface 53
I/O Interface Control 54
I/O Control Flow 55
Timing Charts 56
Sample Programming 65
Section 6 Troubleshooting 69
Handling Errors 70
Errors and Countermeasures 71
Maintenance and Inspection 72
Section 7 Appendices 73
Product Specifications 74
Characteristics 104
Reference Data: Antenna and RF Tags Installation 133
RF Tag Memory Capacities and Memory Type s 165
RF Tag Memory Map 166
Chemical Resistance of the Antennas and RF Tags 167
V600-Compatible Mode 173
Degree of Protection 188
Revision History 190
RFID System
8
User's Manual
Page 11
Section 1
Product Overview
Features10
System Configuration11
Section 1Product Overview
RFID System
User’s Manual
9
Page 12
Section 1
Product Overview
Features
Section 1 Features
The V680-series ID System uses electromagnetic induction in the 13.56-MHz bandwidth, which conforms to
the international standards in ISO/IEC 18000-3 (ISO/IEC 15693). A V680-series ID System enables reading
and writing RF Tag data without contact by connecting a V680-HAM91/V680-HAM81 ID Flag Sensor to a
V680-series Antenna. With control performed in connection with the Basic I/O Units of a Programmable
Controller , ID Flag Sensors provide data management for ap plications such as quality and process control at
production sites.
 Simple Operation with I/O Control as Simple as Using a Regular Sensor
The V680-HAM91 and V680-HAM81 can be used right away to create an RFID System with operation
as easy as with regular Sensors. Start operation simply by setting the mode switch on the ID Flag
Sensor to output the read results to the I/O interface.
 Advanced Line Management
In accessing RF Tag data, up to 64,000 IDs are possible with 16-bit data. And, using the address shift
function enables accessing up to 128 bits, making it possible to build advanced lines.
 Conforms to International Standards of ISO/IEC 18000-3 (ISO/IEC 15693)
Compliance with international standards enables the V680 to be exported to and used in the world's
main countries.
 RF Tags Available with EEPROM or FRAM
Two types of RF Ta g memory are available: EEPROM, with a maximum heat resistance of 180°C
(30 min./200 cycles) and a capacity of 1,000 bytes, and FRAM, with a capacity of 2, 8, or 32 kilobytes,
and long memory life of 10 billion accesses. Chose the ideal type for various worksite applications.
 Smooth Replacement of Previous RFID Systems
All functions of the previous V600 Series are supported, so assets on existing lines can still be used.
The ID Flag Sensor is connected to a Programmable Controller or wire-reduction device using I/O Interface.
The ID Flag Sensor can be connected with a connector by using a optional interface cable. All of the various
V680-series Antennas and RF Tags can be used.
Section 1 System Configuration
When embedding the V680-D1KP52MT, V680-D1KP53M, and V680-D2KF52M in a metal surface, please use the
V680-HS51 or -HS52 Antenna. It can not communicate with the V680-HS63 Antenna.
RFID System
User's Manual
11
Page 14
Section 1 System Configuration
Section 1
Product Overview
MEMO
12
RFID System
User's Manual
Page 15
Section 2
Names and Functions of Components
ID Flag Sensor14
Antennas21
RF Tags22
Section 2Names and Functions of Components
RFID System
User's Manual
13
Page 16
Section 2 ID Flag Sensor
 Interface Connector : CN2
Connect to Inputs.
Note. Please use the optional Interface Cable(Optional).
 Mode Switches
IF Flag Sensor Operation Mode setting switches.
 Interface Connector : CN1
Connect to 24VDC power, INHIBIT/TRIG Input and Outputs.
Recommended Power Supply : S8VS-03024(OMRON)
Note. Please use the Interface Cable(Optional).
 State Indicator LED
RUN : ID Flag Sensor Status(Green)
T/R : RF Tag communications status(Yellow)
NORMAL/ERROR : IF Flag Sensor operat ion result(Green/Red)
READ/WRITE : READ or WRITE operation status(Green/Yellow)
VERIFY OK/NG : Verify Read operation result(Green/Re d )
 Data Display LED
Date Display(Green)
Error Code Display(Red)
Noise Level Display (Green)
• Access Mode Setting Switch : Set the access mode to the RF Tags.
• Output Mode Setting Switch : Set the output mode and output time.
• Read Mode Setting Switch : Set the read operation mode.
• Write Mode Setting Switch : Set the write operation mode.
 Antenna Connector
Connects to V680-series Antennas.
 Access Address Setting
Set the access address to the RF Tag in hexadecimal notation (0000 hex to
FFFF hex)
Section 2
Names and Functions of Components
ID Flag Sensor
14
RFID System
User's Manual
Page 17
 Status Indicator LED
 RUN
The ID Flag Sensor status is displayed.
StatusDefinition
Lit greenNormal
Not litNo power supply or Fatal error.
 T/R
The communication status with the RF Tags is displayed.
StatusDefinition
Lit yellowCommunicating with RF Tag , Measuring Noise level.
Not litStandby
 NORMAL ERROR
The ID Flag Sensor operation result is displayed.
StatusDefinition
Lit greenNormal Completion
Lit redError occurred
Not litStandby
Section 2
Names and Functions of Components
Section 2 ID Flag Sensor
 READ/WRITE
The Read or Write operation mode is displayed.
StatusDefinition
Lit greenRead operation
Lit yellowWrite operation
Not litStandby or Noise check operation
 VERIFY OK/NG
The Verify Read operation result is displayed.
StatusDefinition
Lit greenVerification result is matched.
Lit redVerification result is mismatched.
Not litStandby
 Data Display LED
The Data Display LED show the 16 bits of data that was read or
written when communication complete normally, and show the
Error Code when error was occurred. It also sho w the Noise Le v e l
when measured the noise level.
BrownNoise check mode setting input (Noise check : ON in Read mode)
Write protect enable/disable input (Enabled : OFF, Disabled : ON in Write mode)
Verify data input bit 10 in Verify Mode
Verify data input bit 9 in Verify Mode
Verify data input bit 12 in Verify Mode
Verify data input bit 11 in Verify Mode
Verify data input bit 14 in Verify Mode
Verify data input bit 13 in Verify Mode
Verify data input bit 16 in Verify Mode
Verify data input bit 15 in Verify Mode
Verify data input bit 2 in Verify Mode
Verify data input bit 1 in Verify Mode
Verify data input bit 4 in Verify Mode
Verify data input bit 3 in Verify Mode
Verify data input bit 6 in Verify Mode
Verify data input bit 5 in Verify Mode
Verify data input bit 8 in Verify Mode
Verify data input bit 7 in Verify Mode
DescriptionI/O
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Note: Wire colors are for the V680-A60 Interface Cable (sold separately).
This connector is not required if data will not be written to RF Tags or the address shift function and noise check function
will not be used.
RFID System
User's Manual
17
Page 20
Section 2 ID Flag Sensor
Refer to the following figure for a set position of the Setting Switch.
Cutting edge
Example) When it sets "1".
Refer to the following figure for a set position of the Setting Switch.
Cutting edge
Example) When it sets "1".
Section 2
Names and Functions of Components
 Mode Setting Switches
 Access Mode Setting Switch
Use this switch to set the communications mode for communications with RF Tags.
No.NameRemarks
0SYNC1
1AUTO1
2SYNC2
3AUTO2
4SYNC3
5AUTO3
6NOISE
CHECK
7--8
9
TRIGGER MODE 1 : The ID Flag Sensor starts to communicate with RF Tags when the trigger signal inputs.
AUTO MODE 1 : The ID Flag Sensor starts to communicate with RF Tags automatically when the RF Tag comes
in the communication area.
TRIGGER MODE 2 : Functional compatible mode with V600 series (V600-HAM91/-HAM81/-HAR91/-HAR81)
AUTO MODE 2 : Functional compatible mode with V600 series (V600-HAM91/-HAM81/-HAR91/-HAR81)
TRIGGER MODE 3 : Functional compatible mode of V600 series (V600-HAR92)
AUTO MODE 3 : Functional compatible mode of V600 series (V600-HA R 92)
NOISE MEASURING MODE : The maintenance mode to measure the environmental noise level.
Setting Prohibit
(The ID Flag Sensor indicates Settings Error.)
p.56
p.60
p.175
p.178
p.181
p.183
p.63
 Output Mode Setting Switch
Use this switch to set the output mode and output time width.
No.SettingSettingCombination with the access mode
010 ms OFF DELAY10 ms OFF delayAuto Mode 1, Auto Mode 3, or Trigger Mode 3
150 ms OFF DELAY50 ms OFF delay
2500 ms OFF DELAY500 ms OFF delay
310 ms10 ms output Auto Mode 2 or Trigger Mode 3
450 ms50 ms output
5CONTINUOUS Continuous output
6---Setting prohibited : except for Trigger Mode1(See Note.)
7
8
9
Note. TRIGGER MODE 1 is not influenced the OUTPUT MODE settings. Set the OUTPUT mode switch either from "0" to "9".
(The ID Flag Sensor indicates Settings Error.)
Note: A mode setting error will occur if one of the above
access modes is not set.
Note: A mode setting error will occur if one of the above
access modes is not set.
18
RFID System
User's Manual
The setting of the mode setting switch is read only when the power supply is turned ON. Therefore, settings cannot be
changed while the power is being supplied. Turn OFF the power supply before changing the settings.
Page 21
 Read Mode Setting Switch
Refer to the following figure for a set position of the Setting Switch.
Cutting edge
Example) When it sets "1".
Refer to the following figure for a set position of the Setting Switch.
Cutting edge
Example) When it sets "1".
Use this switch to set the mode for reading data.
Section 2
Names and Functions of Components
Section 2 ID Flag Sensor
No
.
0DATA READ1Outputs read data.
1DATA READ2Outputs read data in Wire-saving Mode.p.30
2VERIFYCompares external input data with read data and outputs the verification result.p.29
3---Setting prohibited.
4
5
6
7
8
9
NameDescription
(The ID Flag Sensor indicates Settings Error.)
 Write Mode Setting Switch
Use this switch to set the mode for writing data.
---
No.NameDescription
02-BYTE WRITE Write the 2 bytes (16 bits) of data that is input to the external data inputs (ID 0 to ID15) to the RF Tag.
1BIT SETWhen external data (ID0 to ID15) is input, only the ON bits will be turned ON. The other bits will not be
changed.
2BIT CLEARWhen external data (ID0 to ID15) is input, only the ON bits will be turned OFF. The other bits will not be
changed.
31-BYTE WRITE Write the 1 byte (8 bits) of data that is input to external data input bits ID0 to ID7 to the RF Tag.
Inputs for external data input bits ID8 to ID15 will be ignored.
4---Setting prohibited.
5
6
7
8
9
Note : This is for supporting V600-series (V600-HAM91/-HAM81) 1byte(8bits) write operation.
The setting of the mode setting switch is read only when the power supply is turned ON. Therefore, settings cannot be
changed while the power is being supplied. Turn OFF the power supply before changing the settings.
(The ID Flag Sensor indicates Settings Error.)
(See Note.)
RFID System
User's Manual
19
Page 22
Section 2 ID Flag Sensor
ItemDescription
Setting
method
Specify the memory address of the RF Tag in 4-digit hexadecimal.
Example to specify an RF Tag memory address of 01A3 hex:
Setting
range
0000 to FFFF hex (See note.)
Default setting: 0000 hex
Note: The upper 8 bits will not be read if FFFF hex is specified for a16-bit read/
write operation. All output bits will be OFF.
“0“
“1“
“A“
“3“
Refer to the follo wing figure f or a se t position
of the Setting Switch.
Cutting edge
Example) When it sets "B".
2
1
Pin No.NameDescriptionI/O
1SSignal line--2GNDAnalog ground---
Section 2
Names and Functions of Components
Access Address Setting Switches
Use these switches to set the memory address for reading data.
The setting of the access address setting switches is read only when the power supply is turned ON.
Therefore, settings cannot be changed while the power is being supplied. Turn OFF the power supply before changing
the settings.
 Antenna Connector
Connect this connector to the V680-series Antenna (described in this User's Manual).
20
RFID System
User's Manual
Page 23
Antennas
(2) Communications sufrace
(2) Communications sufrace
(2) Communications sufrace
(2) Communications sufrace
(3) Ferrite core
(3) Ferrite core
(3) Ferrite core
(3) Ferrite core
(4) Connector
(4) Connector
(4) Connector
(1) Operation indicator
(1) Operation indicator
(4) Connector
(1) Operation
indicator
 V680-HS51
 V680-HS52
 V680-HS63
 V680-HS65
No.NameDescription
1Operation indicatorLights when a signal is transmitted.
2Communication surfaceMounted facing the RF Tags.
3Ferrite core
4ConnectorConnects to the ID Flag Sensor.
Section 2
Names and Functions of Components
Section 2 Antennas
RFID System
User's Manual
21
Page 24
Section 2 RF Tags
 V680-D1KP52MT/-D2KF52M
 V680-D1KP66T/D1KP66MT
 V680-D1KP66T-SP
 V680-D1KP58HTN
 V680-D1KP53M
 V680-D1KP52M-BT01/-D2KF52M-BT01
 V680-D1KP52M-BT11/-D2KF52M-BT11
Section 2
Names and Functions of Components
RF Tags
The ID Flag Sensor communications with th e RF Tags through the Antenna to read and write data in
the internal memory of the RF Tags.
The printed side is the communications surface . Mount t he RF Tags with the communications surf aces
facing the Antenna.
RFID System
22
User's Manual
Page 25
Section 2
 V680-D2KF67/-D2KF67M
 V680-D8KF68/-D32KF68
 V680-D8KF67/-D8KF67M
Names and Functions of Components
Section 2 RF Tags
The ID Flag Sensor communications with th e RF Tags through the Antenna to read and write data in
the internal memory of the RF Tags.
The printed side is the communications surface . Mount t he RF Tags with the communications surf aces
facing the Antenna.
The ID Flag Sensor operates after reading the setting of the mode setting switches when the power supply is
turned ON. Set the mode for communications with the RF Tags or set the Noise Measurement Mode on the
access mode setting switch. There are th ree communicati ons modes, each with diff ere nt timing f or comple ting
communications with RF Tags: Mode 1, Mode 2, and Mode 3. Also , each of these modes has tw o other modes
to specify when to start communications with the RF Tags: Trigger Mode and Auto Mode . Mode 2 and Mode 3
are compatible with the V600 series.
Section 3 Communications Mode
Communications end
timing
Mode 1Trigger Mode10: SYNC1Standard modes
Mode 2Trigger Mode22: SYNC2Compatible with V600-HAR91/81 and HAM91/81.
Mode 3Trigger Mode34: SYNC3Compatible with V600-HAR92.
Some of the functions supported in Mode 1 cannot be used in the V600-compatible modes.
For details, refer to V600-Compatible Mode.
Communications start
timing
Auto Mode11: AUTO1
Auto Mode23: AUTO2
Auto Mode35: AUTO3
p.173
Access mode setting
switch
Mode overview
Trigger Mode
In Trigger Mode, an RF Tag on a workpiece or pallet in the communications area of the Antenna is
detected by a sensor or a switch. A control signal (called the trigger signal) is output from the PLC to
the ID Flag Sensor to trigger the I D Flag Sensor t o begin commu nications with the RF Tag. The ID Flag
Sensor reads the RF Tag data and outputs the results to the PLC.
26
RFID System
User's Manual
Only one Interface Cable (I/O connector CN1) is used to read RF Tag da ta. The address shift, noise check, and parity
check functions, however, are not possible when only CN1 is used.
Page 29
Section 3
Pallet
V680-A60
Interface Cable
PLC
V680-HAM91/V680-HAM81
ID Flag Sensor
V680-series
Antenna
V680-series
RF T ag
Functions
Auto Mode
In Auto Mode, the ID Flag Sensor aut omatically begins co mmun ications wit h a RF Tag on a workpiece
or pallet when it enters the communications area of the Antenna, and then the ID Flag Sensor outputs
the result to the PLC.
Section 3 Communications Mode
Only one Interface Cable (I/O connector CN1) is used to read RF Tag da ta. The address shift, noise check, and parity
check functions, however, are not possible when only CN1 is used.
Noise Measurement
The Noise Measurement Mode can be used to check if there is noise around the Antenna that is
affecting communications with the RF Tag. When the power supply is turned ON with the access mode
switch set to this mode, the noise around the Antenna will be measured and the result will be displayed
on indicators and output to external outputs.
Noise measurement can performed with the above mode setting or by turning ON the NOISE_IN external input when
Trigger Mode 1 or Auto Mode 1 is being used. For details, refer to Trigger Mode1 :Noise Measurement.
p.63
RFID System
User's Manual
27
Page 30
Section 3 Optional Functions
Section 3
Functions
Optional Functions
The following optional functions can be enabled by using the mode setting switches (access mode setting,
output mode setting, read mode setting, or write mode setting) and specifying the control signal.
FunctionDescription
Output time operationSpecified by setting the output mode.
VerificationSet the read mode to "VERIFY".
Wire savingSet the read mode to "DATA READ2".
Write modeSpecified by setting the write mode.
Write protectionSpecified using the WRITE_PROTECT external input.
Address shiftSpecified using theADR0 to ADR2 external inputs.
Noise checkSpecified using the NOISE_IN external input.
Output Time Operation
Set the output method and time for the normal completion output (NORMAL/STRB), error completion
output (ERR
), and data outputs (OD0 to OD15). There are two output methods: OFF delay and fixed
time.
Out of communications range
2 ms
t
OFF delay
In communications
range
Fixed output time
t
1 ms
Out of communications range
2 ms
t
OFF delay
RF T ag position
Fixed time
output
OFF delay
Out of communications
range
ON
OFF
ON
OFF
In communications
range
Fixed output time
1 ms
t
• The output time operation specification depends on the communications mode. A setting error will
occur if an output method that is not supported is set
Communications modeOutput method specificationOutput rotary switch setting range
Standard modes Trigger Mode 1 Designation not required.
Auto Mode 1OFF delay10 ms(“0“)/50 ms(“1“)/500 ms(“2“) OFFDELAY
V600-compatible
modes
Note1. : The output will continue in Trigger Mode 1 until the trigger input turns OFF.
2. : When it is set to "CONTINUOUS" at the FIXED TIME OUTPUT, it keeps OUTPUT until INHIBIT/TRIG input turns to
OFF.
Trigger Mode 2 Fixed time10 ms(“3“)/50 ms(“4“)/CONTINUOUS(“5“) (See note2.)
Auto Mode 2Fixed time10 ms(“3“)/50 ms(“4“)/CONTINUOUS(“5“) (See note2.)
Trigger Mode 3 OFF delay10 ms(“0“)/50 ms(“1“)/500 ms(“2“) OFFDELAY
Auto Mode 3OFF delay10 ms(“0“)/50 ms(“1“)/500 ms(“2“) OFFDELAY
(See note1.)
Either from "0" to "9"
28
RFID System
User's Manual
For detail timing of output time, refer to Section 5Control I/O Interface, and Section 7 Appendices when using V600
compatible mode.
p.56, p.173
Page 31
Section 3
Functions
Verification
The verification function compares th e data (16 bit s) that is in put to the external data input lines (ID0 to
ID15) with the actually data (16 bits) read from the RF Tag, and outputs the result to indicate whether
the data matches or not. The result of the verification is output to the external data outputs (OD0:
Match, OD7: Mismatch, OD1 to OD6 and OD8 to OD15: Not used.) The result can also be checked on
the Data Display LED on the ID Flag Sensor.
Wire-saving Mode
The Wire-saving Mode enables re ading data and detecting errors using only 16 external data outputs
(OD0 to OD15). Control can be performed using one 16-point I/O Unit in a Programmable Controller.
For details, refer to Wire-saving Mode.
p.30
Write Mode
Specify the method for writing data to the RF Tag. Specify the mode to write 2 bytes (16 bits) or 1 byte
(8 bits) at a time, or specify the mode to set or clear specified bits.
Write Protection
Write protection can be enabled to prevent product model numbers, model names, or other important
data saved in RF Tags from being lost.
For details, refer to Write Protection.
p.34
Address Shift
Section 3 Optional Functions
The address set on the access address setting switches can be offset by the value specified by
external data inputs ADR0 to ADR2. This function is useful for reading more 16 bits (2 bytes) of RF Tag
data.
For details, refer to Address Shift.
p.32
Noise Measurement
This function can be used to check if there is noise around the Antenna that is affecting
communications with the RF Tag. The noise measurement when you turn ON the NOISE_IN external
input in Sync Mode 1 or Auto Mode 1. The oper ating mode called Noise Measurem ent Mode by setting
the access mode setting switch to "6" is for measuring noise at startup.
For details, refer to Noise Measurement.
p.33
RFID System
User's Manual
29
Page 32
Section 3 Wire-saving Mode
INHIBIT/TRIG
V680-HAM91/
V680-HAM81
Output Unit
Input Unit 1
Input Unit 2
NORMAL/STRB, ERR,
PARITY (3 points)
OD0 to OD15 (16 points)
Section 3
Functions
Wire-saving Mode
The Wire-saving Mode enab les detecting read data signals and normal/error completion signa ls using only 16
data outputs (OD0 to OD15). Using this mode enables controlling reading 16-bit data using only one 16-point
Input Unit for a PLC or a wire-saving device.
 System Configuration Example: Combination and Usage of I/O Lines in Each Mode
• Normal Read Wiring: DATA READ 1• Wire-saving Read Wiring: DATA READ 2
Number of Required I/O
Output Units: 1
Input Units: 2
Number of Required I/O
Output Units: 1
Input Units: 1
Output Unit
Input Unit
INHIBIT/TRIG
OD0 to OD15 (16 points)
V680-HAM91/V680-HAM81
• For Wire-saving Mode, outputting all zeros on the data lines (0000 hex) is used as communications
control, and outputting all ones on the data lines (FFFF hex) is used as an error completion output.
Normal completion (NORMAL/STRB) is detected by confirming that the output from the data lines is
not all zeros (0000 hex) and not all ones (FFFF hex).
• All zeroes (0000 hex) and all ones (FFFF hex) cannot be used as data when Wire-saving Mode is
used.
• Error codes cannot be output when an error completion occurs. The data indicators, however, will
flash red to show the error code.
• The parity output is not connected and cannot be used.
• The Wire-saving Mode cannot be used when Trigger 2 or Auto 2 Mode is used. Attempting to do so
will result in a settings error.
30
RFID System
User's Manual
Page 33
Section 3
Functions
Parity Check
This function detects vertical parity in the data output on the data outp ut lines (OD0 t o OD15) an d outpu ts the
parity status. If the number o f bit s th at are O N in t he da t a out put lin es is even, then the parity output is OFF. If
the number of bits that are ON in the data output lines is odd, the n the parity output is ON. The parity chec k is
performed for outp ut data on the ca b le communica tions betw een the host device and the ID Flag Sensor . The
parity check can be used to effectively perform simple checks for disconnected cables or wiring.
The parity check cannot be used in Trigger Mode 2 or Auto Mode 2. The ID Flag Sensor indicates a Setting Error.
Access address set on access address setting switches
+ address shift (= 4)
Access address in RF Tag
Section 3
Functions
Address Shift
The address set on the access address setting switches can be offset by the value specified by external data
inputs ADR0 to ADR2 to change the access address. The address shift enables reading or writing to up to 16
access address (up to 128 bits) of RF Tag memory.
Address Specification Example with 8-kilobyte RF Tag
32
Note 1. An address error will occur if the address shift exceeds the maximum address setting (FFFF hex).
2. The address will be shifted by blocks when the 1-Byte Write Mode is used.
Access address setting switches: 0010 hex
Address shift input:3 (ADR2 = 0, ADR1 = 0, ADR0 = 1)
Access address:0013 hex
The address shift function can be used only in Trigger 1 or Auto 1 Mode.
RFID System
User's Manual
Page 35
Section 3
01234567
89101112131415
01234567
89101112131415
01234567
89101112131415
01234567
89101112131415
01234567
89101112131415
01234567
89101112131415
01234567
89101112131415
01234567
89101112131415
01234567
89101112131415
OFF:ON(Green)
0102030
405060
70
20%
40%
60%
80%
100%
0%
Noise level
Communications distance
(noise level 0 to 100%)
Functions
Noise Measurement
You can check whether noise that affect s communications with RF Tags exists in the area where the Antenna
and ID Flag Sensor are installed.
In Trigger Mode 1 or Auto Mode 1, noise measurement is performed by turning ON the NOISE_IN external
input. The result of noise measurement will be output to the external data outputs when the NORMAL/STRB
signal is turned ON after the measurement is performed.
The output will be on a scale of 00 to 99 for the strength of the noise aff ecting the Antenna. The external data
output lines will output the value converted to hexadecimal. The measured noise strength is also displayed in
eight levels on the Data Display LED, and so it can be checked directly on the ID Flag Sensor.
Relation between Result Output and Data Display LED
Result output
“00” to “10“55” to “65
Data indicator status
Result output
Data indicator status
Section 3 Noise Measurement
“11” to “21“66” to “76
“22” to “32“77” to “87
“33” to “43“88” to “99
“44” to “54
Example of Results Output and Influence on Communications Distance
The values given for the influence of the noise level obtained from noise measurement and the communications
distance are for reference only. The results depend on the type of Antenna and RF Tag used, and differences in the
noise environment. Be sure to check carefully when installing the system.
The write protection function protects important data stored in the memory of a RF Tag, such as the product
model or type, from being overwritten inadvertently.
Enable the write protection function after writing important data as described in this section.
Setting Write Protection
For the write protection function to be effective, it must be enabled in both the ID Flag Sensor settings
and the RF Tag settings.
Section 3 Write Protection
1. Enabling the Write Protection in the ID Flag Sensor
Write protection can be enabled by turning OFF pin 6 (NOISE_IN/WRITE PROTECT) of I/O connector CN2.
NOISE_IN/WRITE PROTECT input is effective as WRITE PROTECT input only when it specified write mode(R/W : ON).
Write protect enable/disable settings is effective only TRIGGER MODE 1 and AUTO MODE 1.
Write protect is always enabled at the TRIGGER MODE 2 and AUTO MODE 2.
The method of write protect for TRIGGER MODE 2 and AUTO MODE 2 confirms to the V600 series.
Details of Write Protect function for V600-compatible Mode, refer to the Section 7 Appendices
p.184
2. Setting Write Protection for RF Tags
Write protection is set in the 4 bytes from RF T ag addresses 0000 hex to 0003 he x. Write protection for RF Tags is enabled in the
most significant bit of address 0000 hex.
• Write-protect Bit (most significant bit of address 0000 hex)
1: Write-protected (write protection enable)
0: Not write-protected (write protection disable)
Memory Map for RF Tag Write Protection Settings
Address Bit76543210
0000 hex
0001 hexLower two digits of start address (00 to FF)
0002 hexUpper two digits of end address (00 to FF)
0003 hexLower two digits of end address (00 to FF)
When write protection is not used, the above addresses can be used as user memory. If it is used as user memory,
disable the write protection function of the ID Flag Sensor by turning ON pin 6 (NOISE_IN/WRITE PROTECT) of I/O
connector CN2. NOISE_IN/WRITE PROTECT input must be OFF when reading the RF Tag. If it turns ON during
reading operation, the ID Flag Sensor execute Noise level measurement.
• Addresses in RF Tag Memory That Can Be Write Protected
Start address: 0000 hex to 7FFF hex
End address: 0000 hex to FFFF hex
Enable/
disable
Upper two digits of start address (00 to 7F)
34
RFID System
User's Manual
The write-protection setting area of the RF Tag cannot be write-protected.
Page 37
Example of Write Protection
Address
(hex)
Bit
Upper digitsLower digits
0000
10000000
80
0001
00010101
15
0002
00000001
01
0003
00100000
20
Write-protected
0000 hex
0021 hex
03E7 hex
Address
(hex)
Bit
Upper digitsLower digits
0000
10000000
80
0001
00100001
21
0002
00000000
00
0003
00100001
21
Address
(hex)
Bit
Upper digitsLower digits
0000
10000011
83
0001
00000000
00
0002
00000011
03
0003
11111111
FF
 Start Address Is Lower Than the End Address
The memory area between the start address and end address will be write-protected.
0000 hex
0015 hex
0120 hex
03E7 hex
Section 3
Functions
Write-protected
Section 3 Write Protection
 Start Address Is Equal to End Address
Only the selected address (one byte) will be write-protected.
 End Address Is Higher than the Last RF Tag Address
The memory area between the start address and the last RF Tag address will be write-protected.
0000 hex
0300 hex
03E7 hex
Write-protected
RFID System
User's Manual
35
Page 38
Section 3
Address
(hex)
Bit
Upper digitsLower digits
0000
10000001
81
0001
00100000
20
0002
00000000
00
0003
00010101
15
Functions
 Start Address Is Higher Than End Address
The memory area between the start address and the last RF Tag address, as well as the area betwe en
0004 hex and the end address will be write-protected.
Section 3 Write Protection
0000 hex
0004 hex
Write-protected
End address
Start address
0015 hex
0120 hex
Write-protected
03E7 hex
Disabling Write Protection
 Disabling Write Protection for Part of the RF Tags
Set the uppermost bit of 0000 hex to 0.
 Disabling All Write Protection for the Whole RFID system
Turn ON pin 6 (NOISE_IN/WRITE PROTECT) of the I/O connector on the ID Flag Sensor.
Caution When Using Write Protection:
The write protection function is an OMRON ID Flag Sensor function. It cannot be used with RFID reader/writer
manufactured by other companies.
36
RFID System
User's Manual
Write protect enable/disable settings is effective only TRIGGER MODE 1 and AUTO MODE 1.
Write protect is always enabled at the TRIGGER MODE 2 and AUTO MODE 2.
TRIGGER MODE 3 and AUTO MODE 3 is not supported Write function itself.
Page 39
Section 4
Installation, Connections, and Wiring
ID Flag Sensor38
Installing Antennas43
Installing RF Tags46
Section 4Installation, Connections, and Wiring
RFID System
User's Manual
37
Page 40
Section 4 ID Flag Sensor
Section 4
Installation, Connections, and Wiring
ID Flag Sensor
Installation
To ensure full functionality of the ID Flag Sensor, follow the instructions provided in this section for
installation.
 Installation Site
Do not install the ID Flag Sensor in the following locations.
• Locations exposed to ambient temperatures that are not between −10 and 55°C or where there are
radical temperature changes resulting in condensation
• Locations exposed to humidity that is not between 25% and 85%
• Locations subject to corrosive gas, flammable gas, dust, salt, or metal powder
• Locations that will expose the ID Flag Sensor to direct vibration or shock
• Locations exposed to direct sunlight
• Locations exposed to spray of water, oil, or chemicals
• Locations more than 2,000 m above sea level
 Mounting in a Panel
The ID Flag Sensor can be used at an ambient temperature range of −10 to 55°C. Be sure to observe
the following precautions.
• Make sure that the Unit is provided with sufficient ventilation space.
• Do not install the Unit close to heaters, transformers, or large-cap acity resistors that radiate e xcessiv e
heat.
38
RFID System
User's Manual
Page 41
Section 4
End Plate
End Plate
SpacerSpacer
10 mm min.10 mm min.
Installation, Connections, and Wiring
 Installation Method
The ID Flag Sensor is to be mounted to a DIN Track. Mount the DIN Track, and then mou nt the ID Flag
Sensor to the DIN Track.
1. First hook the ID Flag Sensor Unit to part A, then press it in direction B to mount it to the DIN Track.
2. To disconnect the ID Flag Sensor Unit from the DIN Track, pull the mounting hook downwards, and
then lift the Unit upwards.
DIN Track
End Plate
Mounting Hook
Attaching the End Plates:
To mount an End Plate easily, first hook the bottom of the End Plate and then hook the
top on the DIN Track, pull the End Plate downwards and tighten the screw.
Recommended tightening torque: 1.2 N⋅m.
End Plate
A
DIN Track
PFP-100N2 (OMRON)
B
Mounting Hook
 Mounting Interval
The ID Flag Sensor Units will generate heat if they are mounted side-byside.
Leave space between Units of at least 10 mm.
Section 4 ID Flag Sensor
End Plate
PFP-M (OMRON)
Use at least 2 OMRON DIN Track Spacers. (Each Spacer is 5 mm wide)
Spacer
PFP-S
RFID System
User's Manual
39
Page 42
Section 4
Installation, Connections, and Wiring
Connection and Wiring
 Interface Cable
 INPUT/OUTPUT controls
• When using a solid-state output with the maximum switching current rating over 1A , there is a
possibility of causing External Input Errors due to the delay of rise /fall time of output signal.
Consider this when selecting the solid-state output.
• When using a contact output, consider chattering and the minimum switching current.
• When connecting an inductive load or an electrical device that tends to generate noise to the output,
connect a diode in parallel with t he load. Connect the cat hode side of the diod e to the positiv e side of
the power supply.
Section 4 ID Flag Sensor
WARNING
 Power Supply Voltage
• Do not impose an AC(100VAC to 240VAC) power supply or any voltage exceeding the rated voltage
range on the V680-HAM91/-HAM81. Unsuitable power supplies may cause the V680-HAM91/HAM81 to explode or bum.
 Load Short-circuiting
• Do not short-circuit the load connected to the V680-HAM91/-HAM81 or connect power to the load.
Any of these may cause the V680-HAM91/-HAM81 to explode or bum.
WARNING
• Do not mis-wire and do not reverse polarity of the power sup ply connected to the V680-HAM91/HAM81. Wiring mistakes, including reversed power supply polarity may cause the V680-HAM91/HAM81 to explode or bum.
40
RFID System
User's Manual
Page 43
 Connecting and Disconnecting the ID Flag Sensor
Mounting Procedure
Line up the direction of the triangle mark on the connectors of the ID Flag Sensor and the interface cable, and then
press in the connector of the interface cable.
The lock will engage when the interface cable is pressed
into the connector on the ID Flag Sensor.
Section 4
Installation, Connections, and Wiring
Section 4 ID Flag Sensor
Removal Procedure
To remove the connector of the interface cable, always hold the connector and pull it out in a straight line.
Pulling the cable may result in severing the cable or other product failure.
Unlock the connector on the ID Flag Sensor and pull out
the connector of the interface cable.
RFID System
User's Manual
41
Page 44
Section 4 ID Flag Sensor
Section 4
Installation, Connections, and Wiring
 Antenna Connector
 Mounting the Antenna
1. Hold the connector part of the Antenna and insert it into the
Antenna port while matching the key on the ID Flag Sensor with
the groove on the connector.
Key
Antenna connector
2. Turn the connector clockwise to lock it in place.
 Removing the Antenna
1. Turn the connector in counterclockwise to release t he lock.
2. Pull the connector straight out of the port.
Key
Antenna connector
42
RFID System
User's Manual
The connector cannot be removed without turning it to release the lock.
If the cable is pulled without releasing the lock, it may cause the cable or wires to break. Make sure that the lock is
released before pulling out the connector.
Page 45
Installing Antennas
V680-HS51
Install the Antenna using the nuts and toothed washer that are provided on both sides of the mounting
material, as shown in the diagram below.
Mounting Hole Dimensions
+0.5
12
0
For details on installing Antennas, refer to Antenna Mounting Precautions.
p.133
dia.
Antenna
Toothed washer
Section 4
Installation, Connections, and Wiring
Metallic material
Nut
Section 4 Installing Antennas
Securely tighten the screws to a torque of 6 N⋅m.
V680-HS52
Install the Antenna using the nuts an d toothed wa shers that are provided on bot h sides of the mounting
material, as shown in the diagram below.
When the Antenna is mounted to a metallic material, the communications distance will be reduced by approximately
10% compared with mounting to a non-metallic material.
For details on the effect of metal surrounding the Antenna, refer to Antenna Mounting Precautions.
p.133
Non-metallic material
Mounting Hole Dimensions
+0.5
22
dia.
0
Antenna
Toothed washers
Nuts
Securely tighten the screws to a torque of 40 N⋅m.
RFID System
User's Manual
43
Page 46
Section 4
Two, M4
Coil center
27
53
40
28±0.2
5
Two, 4.5 dia.
Coil center
27
40
28±0.2
A
Nut
Installation, Connections, and Wiring
V680-HS63
 Installation from the Front
 Installation from the Back
Insert the nuts that come with the Antenna into sections A.
Section 4 Installing Antennas
For details on installing Antennas, refer to Antenna Mounting Precautions.
p.133
Securely tighten screws to a torque of 1.2 N⋅m.
44
RFID System
User's Manual
Page 47
V680-HS65
Four, C1
90±0.1
100±0.2
100±0.2
90±0.1
Four, 4.5
+
0.3
dia.
0
V680-HS65
Mounting base
Mounting Bracket
(provided)
Section 4
Installation, Connections, and Wiring
100
90±0.2
Securely tighten screws to a torque of 0.7 to 1.2 N⋅m.
Four, M4
100
90±0.2
Use M4 screws and spring washers (in four places) for
Antenna installation.
 Mounting Bracket Dimensions (Provided Only with the V680-HS65)
Note: When installing the Antenna, mount it on the
enclosed Mounting Brack et. The M ounting Br ack et
is not necessary, however, if the Anten na is
mounted on a metal base that is larger than t he
Antenna (100 × 100 mm).
Section 4 Installing Antennas
For details on installing Antennas, refer to Antenna Mounting Precautions.
p.133
RFID System
User's Manual
45
Page 48
Section 4
Installation, Connections, and Wiring
Installing RF Tags
Section 4 Installing RF Tags
V680-D1KP52MT
 RF Tag Installation Direction
Mount the RF Tags as shown in the diagram on the right. The
epoxy adhesiv es listed in the f ollo wing table are recommended
for the given temperature ranges.
One-part Epoxy Resin: TB2285 Three Bond Co., Ltd.
Two-part Epoxy Resin: TB2087 Three Bond Co., Ltd.
Product nameManufacturer
Three Bond Co., Ltd.
Three Bond Co., Ltd.
Marked side
+0.1
8.1
0
Marked side
dia.
5
0
R0.2 max.
+0.1
When installing RF Tags, refer to RF Tag Mounting Precautions.
p.137
When embedding the V680-D1KP52MT into a metal surface, use the V680-HS51/-HS52 Antenna.
Communications will not be possible if the V680-HS63 Antenna is used.
V680-D1KP52M-BT01/-D1KP52M-BT11
 RF Tag Installation Direction
1. Turn the RF Tag clockwise, attach to the Mounting holes.
V680-D1KP52M-BT01 is attached to the mounting holes in the M10,
V680-D1KP52M-BT11 to the mounting holes in the M8.
RF T ag
Mounting Hole
46
2. Secure by tightening the bolts of the RF Tag.
When mounting the RF Tags, tighten the bolts to the following torques.
V680-D1KP52M-BT01: 24.5 N⋅m
V680-D1KP52M-BT11: 11 N⋅m
RFID System
User's Manual
RF T ag
Page 49
V680-D1KP53M
 RF Tag Installation Direction
Mount the RF Tags as shown in the diagram on the right. The
epoxy adhesiv es listed in the following table are
recommended for the given temperature ranges.
When installing RF Tags, refer to RF Tag Mounting Precautions.
TB2105C (curing agent)
One-part Moisture-curing
Elastic Adhesive
TB1530
One-part Epoxy Resin: TB2285 Three Bond Co., Ltd.
Two-part Epoxy Resin: TB2087 Three Bond Co., Ltd.
Product nameManufacturer
Three Bond Co., Ltd.
Three Bond Co., Ltd.
Section 4
Installation, Connections, and Wiring
V680D1KP53M
R0.5 max.
+0.09
10
dia.
0
+0.2
4.6
0
Marked side
Marked side
Section 4 Installing RF Tags
p.137
When embedding the V680-D1KP53M into a metal surface, use the V680-HS51/-HS52 Antenna.
Communications will not be possible if the V680-HS63 Antenna is used.
RFID System
User's Manual
47
Page 50
Section 4
Installation, Connections, and Wiring
V680-D1KP66T
 Mounting on Non-metallic Material
Mount the RF Tag using M3 pan-head screws from the
marked side.
Tightening torque: 0.3 to 0.5 N⋅m
Mounting Hole Dimensions
Two, M3
M3 pan-head screw
25±0.2
Section 4 Installing RF Tags
 Mounting on Metallic Material
Communications distance will decrease if there is
metal on the back of the V680-D1KP66T RF Tag. If the
RF Tag is to be used mounted to metallic material, use
the separately sold special attachment (V600-A86) or a
non-metallic spacer (e.g., plastic or resin).
When installing RF Tags, refer to RF Tag Mounting Precautions.
p.137
Refer to Effect of Metal on Back of RF Tags (Reference) for information on the effect of metal on the back of the V680-
D1KP66T.
p.142
Marked side
M3 pan-head screw
Marked
side
Attachment (V600-A86)
25±0.2
Mounting Hole Dimensions
Two, M3
25±0.2
25±0.2
48
RFID System
User's Manual
Page 51
V680-D1KP66MT
Two, M5
80±0.2
Mounting Hole Dimensions
Section 4
Installation, Connections, and Wiring
Mount the RF Tag to metal using M3 pan-head screws
from the marked side. Tighten the screws to a torque
of 0.3 to 0.5 N⋅m..
When installing RF Tags, refer to RF Tag Mounting Precautions.
p.137
M3 pan-head screw
Marked side
Mounting Hole Dimensions
Two, M3
25±0.2
25±0.2
V680-D1KP66T-SP
Mount the RF Tag using M5 screws and washers. Tighten the screws to a torque of 1.2 N⋅m.
The installation direction of RF Tags is not restricted by the travel direction in respect to the Antenna.
Section 4 Installing RF Tags
When installing RF Tags, refer to RF Tag Mounting Precautions.
p.137
RFID System
User's Manual
49
Page 52
Section 4
Mounting Hole Dimensions
M12
Two nuts and one split pin are provided wi th the V680-A80 Attachment. Replacement spl it pins must be
provided by the user.
Split pinNominal: 3.2 mm × 20 mm (length)
Installation, Connections, and Wiring
Section 4 Installing RF Tags
V680-D1KP58HTN
 RF Tag Installation Direction
The RF Tags have a limited life span. Therefore, install them in locations in which they can be easily
replaced. Use the following procedure to mount the V680-A80 Attachment when required.
1. Mount the Attachment to the workpiece.
2. Tighten the lock nut.
Use a tightening torque of 21 to 42 N·m.
3. Mount the RF Tag to the Attachment.
The RF Tag can be mounted in either
direction.
Insert the split pin into the 3.2-dia. hole and open the tip of the pin to secure.
RFID System
50
User's Manual
Page 53
V680-D2KF52M
 RF Tag Installation Direction
Mount the RF Tag as shown in the diagram on the right.
The epoxy adhesives listed in the following table are
recommended for the given temperature ranges.
When installing RF Tags, refer to RF Tag Mounting Precautions.
TB2105C (curing agent)
One-part Moisture-curing
Elastic Adhesive
TB1530
One-part Epoxy Resin: TB2285 Three Bond Co., Ltd.
Two-part Epoxy Resin: TB2087 Three Bond Co., Ltd.
Product nameManufacturer
Three Bond Co., Ltd.
Three Bond Co., Ltd.
Section 4
Installation, Connections, and Wiring
R0.2 max.
+0.1
8.1
dia.
0
+0.1
5
0
Marked side
Marked side
Section 4 Installing RF Tags
p.137
When embedding the V680-D2KF52M into a metal surface, use the V680-HS51/-HS52 Antenna.
Communciations will not be possible if the V680-HS63 Antenna is used.
V680-D2KF52M-BT01/-D2KF52M-BT11
 RF Tag Installation Direction
1. Turn the RF Tag clockwise, attach to the Mounting holes.
V680-D2KF52M-BT01 is attached to the mounting holes in the M10,
V680-D2KF52M-BT11 to the mounting holes in the M8.
2. Secure by tightening the bolts of the RF Tag.
RF T ag
Mounting Hole
When mounting the RF Tags, tighten the bolts to the following torques.
V680-D2KF52M-BT01: 24.5 N⋅m
V680-D2KF52M-BT11: 11 N⋅m
RF T ag
RFID System
User's Manual
51
Page 54
Section 4
Two, M3
Marked side
32±0.2
32±0.2
Mounting Hole Dimensions
M3 screw
Installation, Connections, and Wiring
V680-D2KF67/-D2KF67M
 RF Tag Installation Direction
Secure the RF Tag with M3 screws. Tighten the
screws to a torque of 0.6 N⋅m.
Mounting Hole Dimensions
Two, M3
M3 screw
32±0.2
Section 4 Installing RF Tags
When installing RF Tags, refer to RF Tag Mounting Precautions.
p.137
V680-D8KF67/-D8KF67M
 RF Tag Installation Direction
Secure the RF Tag with M3 screws. Tighten the
screws to a torque of 0.6 N⋅m.
When installing RF Tags, refer to RF Tag Mounting Precautions.
p.137
Marked side
32±0.2
52
RFID System
User's Manual
V680-D8KF68/-D32KF68
 RF Tag Installation Direction
Secure the RF Tag with M4 screws. Tighten the screws to a torque of 0.7 to 1.2 N⋅m.
M4 screw
Spring washer
Flat washer
When installing RF Tags, refer to RF Tag Mounting Precautions.
p.137
44
76
Two, M4
Page 55
Section 5
Control I/O Interface
I/O Interface Control54
I/O Control Flow55
Timing Charts56
Sample Programming65
Section 5Control I/O Interface
RFID System
User's Manual
53
Page 56
Section 5
Control I/O Interface
I/O Interface Control
The V680-series ID Flag Sensor can be connected to a PLC, I/O Terminal, B7A-series Link Terminal,
DeviceNet device, or other host device. This section describes operations for connecting to and
communicating with these devices.
Overview of Communications Modes
Use the access mode setting switch to set the communications mode for RF Tag communications.
There are three communications modes, ea ch with dif ferent timing for completin g comm unicat ions with
RF Tags: Mode 1, Mode 2, and Mode 3. Also, each of these modes has two modes to specify when to
start communications with the RF Tags: Tr igger Mode and Auto Mode. Mode 2 and Mode 3 are compatible with the V600.
Section 5 I/O Interface Control
Communications end
timing
Mode 1Trigger0: SYNC MODE 1p.56Standard modes
Mode 2Trigger2: SYNC MODE 2p.175Modes compatible with V600-HAR91/81
Mode 3Trigger4: SYNC MODE 3p.181Modes compatible with V600-HAR92
Some of the functions supported in Mode 1 cannot be used in the V600-compatible modes.
Communications start
timing
Auto1: AUTO MODE 1p.60
Auto3: AUTO MODE 2p.178
Auto5: AUTO MODE 3p.183
p.174
Access mode setting Timing
Mode overview
Charts
and V600-HAM91/81
54
RFID System
User's Manual
Page 57
Section 5
Mode setting switch settings
RF T ag position
Communications
with RF Tag
INHIBIT/TRIG
NORMAL/STRB
In communications area
1. Start of communications
2. End of communications
3. Result cleared
Reading
Read data 0000 hex
0000 hex
Data output
(OD0 to OD15: 16 bits)
3 ms
Mode setting switch settings
RF T ag position
Communications
with RF Tag
INHIBIT/TRIG
NORMAL/STRB
Data output
(OD0 to OD15: 16 bits)
In communications range
2. Start of communications
3. End of communications
4. Result cleared
Reading
Read data 0000 hex
0000 hex
1. Preparing Communications
3 ms
OFF delay time
Control I/O Interface
I/O Control Flow
The operation outline f or ID Flag Sensor at Trigger Mode 1 and Auto Mode 1 a re shown in th is page. F or de tail
timing of ID Flag Sensor , ref er to the timing charts in this section. Control the I D Flag Sensor according to the
timing charts.
Trigger Mode
Example: Timing Chart for Trigger Mode 1, and Successful Read
1. Start of communicationsTurn ON the INHIBIT/TRIG input to start communications with the RF Tag after confirming the RF Tag is in the communications area of the Antenna.
2. End of communicationsIf communications with the RF Tag are completed normally, the ID Flag Sensor will turn
ON the NORMAL/STRB output and will output the read data to the data output bits (OD0
to OD15). The NORMAL/STRB output turns ON 3 ms after the data output lines. Read
the data output after the NORMAL/STRB output turns ON.
3. Clearing resultsWhen you turn OFF the INHIBIT/TRIG input, the NORMAL/STRB output will be turned
OFF, and data output will be cleared to 0000 hex.
Auto Mode
Example: Timing Chart for Auto Mode 1, and Successful Read
Section 5 I/O Control Flow
1. PreparationsTurn OFF the INHIBIT/TRIG input in advance to enable communications.
2. Start of communicationsThe ID Flag Sensor will start communications with the RF Tag when the RF Tag enters
3. End of communicationsIf communications with the RF Tag are completed normally, the ID Flag Sensor will turn
4. Clearing resultsAfter the RF Tag is out of the communications area of the Antenna, the NORMAL/STRB
the communications area of the Antenna.
ON the NORMAL/STRB output and will output the read data to the data output bits (OD0
to OD15). The NORMAL/STRB output turns ON 3 ms after the data output lines. Read
the data output after the NORMAL/STRB output turns ON.
output and data output bits will be turned OFF after the time set for the OFF delay in the
output mode time setting has elapsed.
RFID System
User's Manual
55
Page 58
Section 5
Mode setting switch settings
RF T ag position
Communications
with RF Tag
In communications range
INHIBIT/TRIG
Reading
0 hex
NORMAL/STRB
PARITY output
NOISE_OUT
output
0 0
Error
code
0000 hex
AB C
D
E
F
G
R/W input
ERR output
Address shift input
(ADR0 to 2: 3 bits)
Parity
value
Parity
value
0000 hex
Data output
(OD0 to OD15: 16 bits)
Read
data
Normal completion
Completion with error
Data Display LED
(0 to 15: 16 bits)
Reading
Read data display (green)Error code display (red)
0000 hex
0000 hex
0
3 ms
3 ms
Address shift data
Access Address : 0010 hex
Control I/O Interface
Timing Charts
Trigger Mode 1: Read
Section 5 Timing Charts
 Normal Completion of Communications with RF Tag
A. PreparationsBefore starting communications with the RF Tag, turn OFF the R/W input and set the address shift
B. Start of communicationsTurn ON the INHIBIT/TRIG input to s ta rt communicatio ns wi th the RF Tag after confirming the RF
C. End of communicationsIf communications with the RF Tag are completed normally, the ID Flag Sensor will turn ON the
D. Clearing resultsWhen you turn OFF the INHIBIT/TRIG input, th e NORM/STRB output will be turned OFF, the par-
input bits (ADR0 to ADR2).
Tag is in the communications area of the Antenna.
NORMAL/STRB output, store t he parity v alue i n the PARITY output, and store the read data in the
data output bits (OD0 to OD15). The Data Display LED(0 to 15) corresponding to the read data
will be lit green.
ity value (0) will be set on the PARITY output, and the data output bits (OD0 to OD15) will be
cleared to 0000 hex.
RFID System
56
User's Manual
 Error Completion of Communications with RF Tag
E. Start of communicationsTurn ON the INHIBIT/TRIG input to start communications with the RF Tag.
F. End of communicationsIf communications with the RF Tag are completed with an error(No RF Tag error), the ID Flag Sen-
G. Clearing resultsWhen you turn OFF the INHIBIT/TRIG input, the ERR output will be turned OFF “1“, the parity
• Wait at least 10 ms after switching the R/ W inpu t lin e be fore performing next proc es s.
• Switch the address shift input (ADR0 to ADR2) at least 10 ms before accessing the RF Tag(e.g., at least 10 ms before turning
ON the trigger input).
• Read the data output (OD0 to OD15) after the NORMAL/STRB output turns ON.
sor will turn ON ”0” the ERR output, store the parity value in the PARITY output, and store the
error code in the data output bits (OD0 to OD15). Th e data indicator s (0 to 15) corre sponding to
the error code will be lit red.
value (0) will be set on the PARITY output, and the Data Display LED (OD0 to OD15) will be
cleared to 0000 hex.
Page 59
Trigger Mode1 : Read with Wire-saving Mode
Mode setting switch settings
RF T ag position
Communications
with RF Tag
In communications range
INHIBIT/TRIG
Reading
0 hex
NORMAL/STRB
PARITY output
NOISE_OUT
output
0 0
FFFF hex
0000 hex
AB C
D
E
F
G
R/W input
ERR output
Address shift input
(ADR0 to 2: 3 bits)
Parity
value
0
0000 hex
Data output
(OD0 to OD15: 16 bits)
Read
data
Normal completion
Completion with error
Data Display LED
(0 to 15: 16 bits)
Reading
Read data display (green)Error code display (red)
0000 hex
0000 hex
0
3 ms
3 ms
Address shift data
Access Address : 0010 hex
Section 5
Control I/O Interface
 Normal Completion of Communications with RF Tag
 Error Completion of Communications with RF Tag
A. PreparationsBefore starting communications with the RF Tag, turn OFF the R/W input and set the address shift
B. Start of communicationsTurn ON the INHIBIT/TRIG input to s ta rt communicatio ns wi th the RF Tag after confirming the RF
C. End of communicationsIf communications with the RF Tag are completed normally, the ID Flag Sensor will turn ON the
D. Clearing resultsWhen you turn OFF the INHIBIT/TRIG input, th e NORM/STRB output will be turned OFF, the par-
input bits (ADR0 to ADR2).
Tag is in the communications area of the Antenna.
NORMAL/STRB output, store t he parity v alue i n the PARITY output, and store the read data in the
data output bits (OD0 to OD15). The Data Display LED(0 to 15) corresponding to the read data
will be lit green.
ity value (0) will be set on the PARITY output, and the data output bits (OD0 to OD15) will be
cleared to 0000 hex.
E. Start of communicationsTurn ON the INHIBIT/TRIG input to start communications with the RF Tag.
F. End of communicationsIf communications with the RF Tag are completed with an error(No RF Tag error), the ID Flag Sen-
G. Clearing resultsWhen you turn OFF the INHIBIT/TRIG input, the ERR output will be turned OFF “1“, the parity
sor will turn ON “0“ the ERR output, store the parity value in the PARITY output, and store FFFF
hex (ON all bits) in the data output bits (OD0 to OD15). The Data Display LED (0 to 15) corresponding to the error code will be lit red.
value (0) will be set on the PARITY output, and the data output bits ( OD0 to OD 15) w ill be clea red
to 0000 hex.
Section 5 Timing Charts
• Wait at least 10 ms after switching the R/ W inpu t lin e be fore performing next proc es s.
• Switch the address shift input (ADR0 to ADR2) at least 10 ms before accessing the RF Tag (e.g., at least 10 ms before turning
ON the trigger input).
• If communications cont rol will be performed usi ng only data output l ines withou t using the N ORMAL/STRB out put, for example, implement programming for a timer with a specified time, check the status of each data output line at each specified time,
and read the outputs as data after the data is all zeros or all ones.
• All ones and all zeros of data outputs cannot be used as data.
• All data output bits will be ON when an error occurs. The Data Display LED (0 to 15) will flash the error code in red corre-
sponding to the occurring error.
RFID System
User's Manual
57
Page 60
Section 5
3 ms
Access Address : 0010 hex
Verifying
Verifying
Mode setting switch settings
RF T ag position
Communications
with RF Tag
INHIBIT/TRIG
NORMAL/STRB
PARITY output
NOISE_OUT
output
ABC DEF G
R/W input
ERR output
Address shift input
(ADR0 to 2: 3 bits)
Data output
(OD0 to OD15: 16 bits)
Data Display LED
(0 to 15: 16 bits)
Data intput
(ID0 to ID15: 16 bits)
In communications range
Address shift data
In communications range
0000 hex
0001 hex
0080 hex
0000 hex
H
Reference data and read data match
Reference data and read data do not match.
0 hex
0
0000 hex
All OFF
Reference data (green)
Reference data (green)
3 ms
Reference Data
Control I/O Interface
Trigger Mode1: VERIFY
Section 5 Timing Charts
A, B. Preparat ionsTurn OFF the R/W input before star ting communications with t he RF Tag, set reference data on
the data input bits (ID0 to ID15), and set the address shift input bits (ADR0 to ADR2).
 Reference Data and Read Data Match
C. Start of communicationsTur n ON t he IN HIB IT/T RI G in pu t to s ta rt communications with th e RF Tag after confirming the RF
D. En d of communicationsIf communicatio ns with the RF Tag are completed normally, the ID Flag Sensor will turn ON the
E. Clearing resultsWhen you turn O FF the INHIBIT/TRIG input, the NORMAL/STRB output and the data output bit
 Reference Data and Read Data Mismatch
F. Star t of communicationsTurn ON the INHIBIT/TRIG input to start communications with the RF Tag after confirming the RF
G. End of communicationsIf communications with the RF Tag are completed normally, the ID Flag Sensor will turn ON the
H. Clearing resultsWhen you tur n OFF the INHIB IT/TRIG input, the NORMAL/STRB output and the data output bit
Tag is in the communications area of the Antenna.
NORMAL/STRB output and the data outp ut bit (OD0: data matc h). The VERIF Y OK/NG indi cator
will be lit green, and the Data Display LED (0 to 15) corresponding to the reference data will be lit
green.
(OD0) will be turned OFF.
Tag is in the communications area of the Antenna.
NORMAL/STRB output and the data output bit (OD7: data mismatch). The VERIFY OK/NG indicator will be lit red, and the Data Display LED (0 to 15) corresponding to the reference data will be
lit green.
(OD7) will be turned OFF.
58
RFID System
User's Manual
• Wait at least 10 ms after switching the R/ W inpu t lin e be fore performing next proc es s.
• Switch the address shift input (ADR0 to ADR2) at least 10 ms before accessing the RF Tag(e.g., at least 10 ms before turning
ON the trigger input).
• Switch the reference data input (ID0 to ID15) at least 10 ms before accessing the RF Tag(e.g., at least 10 ms before turning
ON the trigger input).
• Read the data output(OD0 to OD15) after the NORMAL/STRB output turns ON.
Page 61
Trigger Mode1: Write
RF T ag position
Communications
with RF Tag
INHIBIT/TRIG
In communications range
Writing
Write data
NORMAL/STRB
PARITY output
R/W input
ERR output
Address shift input
(ADR0 to 2: 3 bits)
Data output
(OD0 to OD15: 16 bits)
Data Display LED
(0 to 15: 16 bits)
Data intput
(ID0 to ID15: 16 bits)
NOISE_OUT
output
Error
code
0000 hex
ABC DEF GH
Normal completion
Completion with error
0000 hex
All OFF
0
0 hex
Write
failed
Write data display (green)
Error code display (red)
In communications range
Access Address : 0010 hex
Mode setting switch settings
3 ms
3 ms
10
Address shift data
Section 5
Control I/O Interface
A, B. PreparationsTurn ON the R/W input before starting communications with the RF Tag, set the write data on the
data input bits (ID0 to ID15), and set the address shift input bits (ADR0 to ADR2).
 Normal Completion of Communications with RF Tag
C. Start of communicationsTurn ON the INHIBIT/TRIG input to start communications with the RF Tag after confirming the RF
D. End of communicationsIf communications with the RF Tag are completed normally, the ID Flag Sensor will turn ON the
E. Clearing resultsWhen you turn OFF the INHIBIT/TRIG input, the NORMAL/STRB output will be turned OFF.
 Error Completion of Communications with RF Tag
F. Start of communicationsTurn ON the INHIBIT/TRIG input to start communications with the RF Tag after confirming the RF
G. End of communicationsIf communications with the RF Tag are completed with an error (Write-verify error, Lock error , Write-
H. Clearing resultsWhen you turn OFF the INHIBIT/TRIG input, the ERR output will be turned OFF “1“, and the data
Tag is in the communications area of the Antenna.
NORMAL/STRB output, and the Data Display LED (0 to 15) corresponding to the write data will be
lit green.
Tag is in the communications area of the Antenna.
protect error etc.), the ID Flag Sensor will turn ON “0“ the ERR output, and the error code will be
stored in the data output bits (OD0 to OD15). The Data Display LED (0 to 15) corresponding to the
error code will be lit red.
output bits (OD0 to OD15) will be cleared to 0000 hex.
Section 5 Timing Charts
• Wait at least 10 ms after switching the R/ W inpu t lin e be fore performing next proc es s.
• Switch the address shift input (ADR0 to ADR2) at least 10 ms before accessing the RF Tag (e.g., at least 10 ms before turning
ON the trigger input).
• Switch the write data input ( ID0 to ID15) at least 10 ms before accessing th e RF Tag (e.g., at least 10 ms before turning ON
the trigger input).
RFID System
User's Manual
59
Page 62
Section 5
In communications range
In communications range
Reading
INHIBIT/TRIG
R/W input
Communications
with RF Tag
0 hex
Address shift data
Address shift input
(ADR0 to 2: 3 bits)
NORMAL/STRB
ERR output
PARTY output
NOISE_OUT
output
Data output
(OD0 to OD15: 16 bits)
Data Display LED
(0 to 15: 16 bits)
A
B
C
D
E
0000 hex
Normal completion
Read
data
OFF delay time
RF T ag position
Parity
Value
0000 hex
0000 hex
Read data display (green)
Reading
incomplete
Access Address : 0010 hex
Output Mode : 10 ms OFF delay
Mode setting switch settings
3ms
0 0
Control I/O Interface
Auto Mode1: Read
Section 5 Timing Charts
A. PreparationsBefore starting communications with the RF Tag, turn OFF the R/W input and set the address shift
B. Canceling communications
 Normal Completion of Communications with RF Tag
C. Start of communicationsThe ID Flag Sensor will start communications with the RF Tag when the RF Tag enters the com-
D. End of communicationsIf communications with the RF Tag are completed normally, the ID Flag Sensor will turn ON the
E. Clearing resultsAfter the RF Tag is out of the communications area of the Antenna, the NORMAL/STRB output
prohibition
input bits (ADR0 to ADR2).
Turn OFF the INHIBIT/TRIG before starting communications.
munications area of the Antenna.
NORMAL/STRB output and will store the read data in the data output bits (OD0 to OD15). The
Data Display LED (0 to 15) corresponding to the read data will be lit green.
and data output bits (OD0 to OD15) will be turned OFF after the time set for the OFF delay in the
output mode time setting has elapsed.
The NORMAL/STRB output, the data output bits (OD0 to OD15) and the Data Display LED can be
unconditionally cleared by turning ON the INHIBIT/TRIG input.
RFID System
60
User's Manual
• At least 10 ms is required for enabling INHIBIT/TRIG input as operation prohibit or clear the data.
• Wait at least 10 ms after switching the R/ W inpu t lin e be fore performing next proc es s.
• Switch the address shift input (ADR0 to ADR2) at least 10 ms before accessing the RF Tag (e.g., at least 10 ms before turning
ON the trigger input).
• Read the data output (OD0 to OD15) after the NORMAL/STRB output turns ON.]
• In Auto Mode, the ID Flag Sensor does n ot ou t put th e e rro r i n case wh en the ID Fl ag S ensor c an not co mpl ete th e communi -
cation process caused by passing the RF Tag quickly in the communications area of the Antenna before completing the communication or interfering by electrical noise. Be sure to check the communications carefully when installing the system.
• Error in Auto Mode will occur when the input to th e ID Fl a g Se nsor h as er ro rs suc h a s t he external input error or address set ting error at the time to start the communications with the RF Tag. In this case, the ID Flag Sensor will turns ON"0" the ERR
output and will store the error code in the data output bits (OD0 to OD15) in Normal Read Mode, or will store FFFF hex(ON all
bits) in Read Mode with Wire-saving mode. The Data Display LED(0 to 15) corresponding to the error code will be lit red.
Page 63
Auto Mode1: VERIFY
In communications range
RF T ag position
INHIBIT/TRIG
Communications
with RF Tag
0000
hex
0 hex
Verifying
Verifying
R/W input
Data intput
(ID0 to ID15: 16 bits)
NORMAL/STRB
PARITY output
ERR output
Address shift input
(ADR0 to 2: 3 bits)
NOISE_OUT
output
Data output
(OD0 to OD15: 16 bits)
Data Display LED
(0 to 15: 16 bits)
0001 hex
0080 hex
0000 hex
ABCDEFG
Address shift data
H
Reference data and read data match
Reference data and read data do not match.
I
OFF delay time
OFF delay time
Reference data2 (green)
0000 hex
Reference data1 (green)
0
0000 hex
All OFF
3 ms
3 ms
Access Address : 0010 hex
Output Mode : 10 ms OFF delay
Mode setting switch settings
Reference data1Reference data2
In communications range
Section 5
Control I/O Interface
A, B. PreparationsBefore starting communications with the RF Tag, turn OFF the R
C. Canceling communica-
 Reference Data and Read Data Match
D. Start of communicationsThe ID Flag Sensor will start communications with the RF Tag when the RF Tag enters the communications
E. End of communicationsIf communications with the RF Tag are co mpleted normally, the ID Flag Sensor will turn ON the NORMAL/STRB
F. Clearing results
 Reference Data and Read Data Mismatch
G. Start of communicationsThe ID Flag Sensor will start communications with the RF Tag when the RF Tag enters the communications
H. End of communicationsIf communications with the RF Tag are completed normally, the ID Flag Sensor will turn ON the NORMAL/ST RB
I. Clearing results
input bits (ID0 to ID15), and set the address shift input bits (ADR0 to ADR2).
tions prohibition
• At least 10 ms is required for enabling INHIBIT/TRIG input as operation prohibit or clear the data.
• Wait at least 10 ms after switching the R
• Switch the address shift input (ADR0 to ADR2) at least 10 ms before accessing the RF Tag.
• Switch the reference data input (ID0 to ID15) at least 10 ms before accessing the RF Tag.
• Read the data output (OD0 to OD15) after the NORMAL/STRB output turns ON.
• In Auto Mode, the ID Flag Sensor does not output the error in case when the ID Flag Sensor can not complete the communication
process caused by passing the RF Tag quickly in the communications area of the Antenna before completing the communication or
interfering by electrical noise. Be sure to check the communications carefully when installing the system.
Turn OFF the INHIBIT/TRIG before starting communications.
area of the Antenna.
output and the data output bit (OD0: data match). The VERIFY OK/NG indicator will be lit green, and the data
indicators (0 to 15) corresponding to the reference data will be lit green.
After the RF Tag is out of the communications area of the Antenna, the NORMAL/STRB output and data output bits
(OD0 to OD15) will be turned OFF after the time set for the OFF delay in the output mode time setting has elapsed.
The NORMAL/STRB output , the data output bits (OD0 to OD15) an d the Data Displ a y L ED can be uncondit ionally cleared by turning ON the INHIBIT/TRIG input.
area of the Antenna.
output and the data output bit (OD7: data mismatch). The VERIFY OK/NG indicator will be lit red, and the data
indicators (0 to 15) corresponding to the reference data will be lit green.
After the RF Tag is out of the communications area of the Antenna, the NORMAL/STRB output and data output bits
(OD0 to OD15) will be turned OFF after the time set for the OFF delay in the output mode time setting has elapsed.
The NORMAL/STRB output, the data output bi ts (OD0 to OD15) and the Data Display LED can be uncon ditionally cleared by turning ON the INHIBIT/TRIG input.
/W input line before performing next process.
/W input, set the reference data on the data
RFID System
User's Manual
Section 5 Timing Charts
61
Page 64
Section 5
Control I/O Interface
Auto Mode1: Write
Mode setting switch settings
RF T ag position
INHIBIT/TRIG
In communications range
In communications range
Communications
with RF Tag
Data intput
(OD0 to OD15: 16 bits)
Access Address : 0010 hex
Output Mode : 10 ms OFF delay
Section 5 Timing Charts
R/W input
Address shift input
(ADR0 to 2: 3 bits)
NORMAL/STRB
ERR output
PARITY output
NOISE_OUT
output
Data output
(OD0 to OD15: 16 bits)
Data Display LED
(0 to 15: 16 bits)
0000
hex
0 hex
0000 hex
All OFF
B
A
Writing
Write data
Address shift data
3 ms
OFF delay time
0
Write data display (green)
C
D
E
F
Writing
3 ms
Error code display (red)
G H
OFF delay time
10
Error
code
0000 hex
I
Normal completionCompletion with error
A, B. PreparationsTurn ON the R
C. Canceling communications
prohibition
bits (ID0 to ID15), and set the address shift input bits (ADR0 to ADR2).
Turn OFF the INHIBIT/TRIG before starting communications.
/W input before starting communications with the RF Tag, set the write data on the data input
 Normal Completion of Communications with RF Tag
D. Start of communicationsThe ID Flag Sensor will start communications with the RF Tag when the RF Tag enters the communications
E. End of communications
F. Clearing resultsAfter the RF Tag is out of the communications area of the Antenna, the NORMAL/STRB output and data out-
area of the Antenna.
If communications with the RF Tag are completed normally , the ID Flag Sensor will turn ON the NORMAL/STRB
output. The Data Display LED (0 to 15) corresponding to the write data will be lit green.
put bits (OD0 to OD15) will be turned OFF after the time set f or the OFF dela y in the output mode time sett ing
has elapsed.
The NORMAL/STRB output, the data output bits (OD0 to OD15) and the Data Display LED can be unconditionally cleared by turning ON the INHIBIT/TRIG input.
 Error Completion of Communications with RF Tag
G. Start of communicationsThe ID Flag Sensor will start communications with the RF Tag when the RF Tag enters the communications
H. End of communications
I. Clearing resultsAfter the RF Tag is out of the communications area of the Antenna, the ERR output will turns OFF"1" and
area of the Antenna.
If communications with the RF Tag are completed with an error (Write Verify error, Lock error, Write-protect error
etc.), the ID Flag Sensor will turn ON “0“ the ERR output and will store the error data in the data output bits (OD0 to
OD15). The Data Display LED (0 to 15) corresponding to the error data will be lit red.
data output bits (OD0 to OD15) will be turned OFF after the time set for the OFF delay in the output mode
time setting has elapsed.
The NORMAL/STRB output, the data output bits (OD0 to OD15) and the Data Display LED can be unconditionally cleared by turning ON the INHIBIT/TRIG input.
62
RFID System
User's Manual
• At least 10 ms is required for enabling INHIBIT/TRIG input as operation prohibit or clear the data.
• Wait at least 10 ms after switching the R/W input line before performing next process.
• Switch the address shift input (ADR0 to ADR2) at least 10 ms before accessing the RF Tag.
• Switch the write data input (ID0 to ID15) at least 10 ms before accessing the RF Tag.
• In Auto Mode, the ID Flag Sensor does not output the error in case when the ID Flag Sensor can not complete the communication
process caused by passing the RF Tag quickly in the communications area of the Antenna before completing the communication or
interfering by electrical noise. Be sure to check the communications carefully when installing the system.
Page 65
Trigger Mode1 :Noise Measurement
Mode setting switch settings
INHIBIT/TRIG
Section 5
Control I/O Interface
Measuring
noise level
NOISE_IN/WRITE
PROTECT input
R/W input
NORMAL/STRB
NOISE_OUT
output
PARITY output
Data output
(OD0 to OD15: 16 bits)
Data Display LED
(0 to 15: 16 bits)
A. PreparationsTurn OFF the R
Measuring
noise level
3 ms
0 0
0000 hex
B
A
Parity value
0000 hexNoise level data
Noise level display (green)
C
D
E
/W input and INHIBIT/TRIG input, and turn ON the NOISE_IN/WRITE
PROTECT input.
B. Start of measurementTurn ON the INHIBIT/TRIG input to start noise measurement.
C. End of measurementWhen the noise level measurement is completed, the ID Flag Sensor will turn ON the
NORMAL/STRB output, store the noise level data in the output data bits (OD0 to OD15),
and store the parity value in the PARITY output.
D. Clearing resultsWhen you turn OFF the INHIBIT/TRIG input, the NORMAL/STRB output will be turned OFF,
the parity value(0) will be set on the P ARITY output, and the data output bits (OD0 to OD15)
will be cleared to 0000 hex.
E. Return to communicationsTurn OFF the INHIBIT/TRIG input and NOISE_IN/WRITE PROTECT input to return to read
and write communication mode.
Section 5 Timing Charts
• At least 10 ms the INHIBIT/TRIG input duration is required for measuring the noise level.
• Read the noise level data output (OD0 to OD15) after the NORMAL/STRB output turns ON.
RFID System
User's Manual
63
Page 66
Section 5
Control I/O Interface
Auto Mode1 (Noise Measurement)
Mode setting switch settings
INHIBIT/TRIG
Measuring
noise level
NOISE_IN/WRITE
PROTECT input
R/W input
NORMAL/STRB
NOISE_OUT
output
PARITY output
Data output
Section 5 Timing Charts
(OD0 to OD15: 16 bits)
Data Display LED
(0 to 15: 16 bits)
A. PreparationsTurn OFF the R
Measuring noise level
3 msApprox. 10 ms3 msApprox. 10 ms
0 0
0000 hex
B
A
C
Measuring noise level
Parity
value
Noise level data
0000 hex
Noise level display (green)
D
Parity
value
Noise level data
Noise level display
(green)
/W input , and turn ON the INHIBIT/TRIG input and the NOISE_IN/WRITE
E
PROTECT input.
B. Start of measurementTurn OFF the INHIBIT/TRIG input to start noise measurement.
C. End of measurementWhen the noise level measurement is completed, the ID Flag Sensor will turn ON the
NORMAL/STRB output, store the noise level data in the output data bits (OD0 to OD15),
and store the parity value in the PARITY output.
D. Clearing resultsAbout 10msec has elapsed after output NORMAL/STRB output, the NORMAL/STRB output
will be turned OFF, the parity value(0) will be set on the PARITY output, and the data output
bits (OD0 to OD15) will be cleared to 0000 hex. And then, start noise measurement
repeatedly.
E. Return to communicationsTurn OFF the INHIBIT/TRIG input and NOISE_IN/WRITE PROTECT input to return to read
and write communication mode.
64
RFID System
User's Manual
• At least 10 ms the INHIBIT/TRIG input duration is required for measuring the noise level.
• Read the noise level data outpu (OD0 to OD15) after the NORMAL/STRB output turns ON.
Page 67
Section 5
DIFU
100.00
100.01
00.00
100.00
02.00
01.00
01.01
01.02
01.14
01.15
Mode setting switch settings
StartINHIBIT/TRIG input
NORMAL output
Upwardly
differentiated
status of
NORMAL output
Model 1
Model 2
Model 3
Model 15
Model 16
Data output bit OD0
Data output bit OD1
Data output bit OD2
Data output bit OD14
Data output bit OD15
Detects when NORMAL output
turns ON.
100.07
End
110.0
Self-holding
DIFU
100.01
00.10
external SW
100.07
End
110.0
Self-holding bit
When the external SW turns ON,
INHIBIT/TRIG input turns ON,
and the ID Flag Sensor starts
communications.
Control I/O Interface
Sample Programming
Reading Flags
This sample program shows a programming example for using an external switch with a Sensor or other
device to read RF Tag data and turn ON the outputs for bits allocated to various devices.
Section 5 Sample Programming
RFID System
User's Manual
65
Page 68
Section 5
Mod
Control I/O Interface
Detecting Disconnection
This sample program shows a programming example for detecting disconnection of data output lines
(16 lines) by using the parity output.
Section 5 Sample Programming
e setting switch settings
00.10
SW
100.01
Start
110.00
Self-holding
00.00
NORMAL output
100.00
Upwardly
differentiated
status of
NORMAL output
100.07
End
00.02
PARITY output
Carry flag
P_CY
DIFU
100.01
INHIBIT/TRIG input
Self-holding
DIFU
100.00
BCNT
#0000
1
D0000
++
D0000
ASR
D0000
When the external SW turns ON,
INHIBIT/TRIG input turns ON, and the ID Flag
Sensor starts communications.
02.00
110.00
Detects when NORMAL output
turns ON.
Counts the number of ON bits in the data output
bits(OD0 to OD15) and store in the DM0000.
Add the PARITY output result to the data output bits ON number. (Even : normal, Odd : error)
Check the PARITY results. When the results is
odd(error), P_CY flags turns ON.
100.02
Disconnection Detected
If the number is odd, there is a disconnection.
100.07
100.02
Disconnection
Detected
100.03
Cable Disconnection Indication
End
100.03
Cable Disconnection Indication
Indicates the disconnection.
66
RFID System
User's Manual
Page 69
Section 5
Mode setting switch settings
01.00
Data output bit OD0
01.01
Data output bit OD1
01.02
Data output bit OD2
01.03
Data output bit OD3
01.14
Data output bit OD14
01.15
Data output bit OD15
100.00
Upwardly differentiated
status of Data output
100.07
End
TIMH
000
#0001
110.00
Self-holding
110.00
Self-holding
CMP
000
#FFFF
T0000
TIMER 000
P_EQ
P_EQ
100.06
Error completion
100.05
Normal completion
100.07
End
MOV
000
D0000
DIFU
100.00
Detects when either of the data output
bits(OD0 to OD15) turns ON.
Set the time 10msec at the timer000
( #0001 x 10msec =10msec).
Wait 10msec after detecting either of
data output bits(OD0 to OD15) turns ON.
Compare the data output bits
(OD0 to OD15) and FFFFHex(all ones).
Store the data output bits to DM0000.
If the data output bis is all ones,
turns ON error completion contact.
If the data output bis is not all ones,
turns ON normal completion contact.
Control I/O Interface
Auto Mode with Wire-saving Mode
This sample program shows a programming example for reading the RF Tag in Auto
Mode with Wire-saving mode. The ID Flag Sensor read the RF Tag data in Auto Mode
with Wire-saving mode , store the read data in the DM0000, and outputs normal
completion contact(100.05). If the communications is completed with error, error
completion contact(100.06) turns ON.
Section 5 Sample Programming
RFID System
User's Manual
67
Page 70
Section 5
Control I/O Interface
MEMO
Section 5 Sample Programming
68
RFID System
User's Manual
Page 71
Section 6
Troubleshooting
Handling Errors70
Errors and Countermeasures71
Maintenance and Inspection72
Section 6Troubleshooting
RFID System
User's Manual
69
Page 72
Section 6
Troubleshooting
Handling Errors
Check the error status by loo king at the 16bits Data Displa y LED and the Error output(ERR)/Dat a Output(O D0
to OD15), and then take suitable actions.
Hardware Errors
Data Output
Lit redNo output Hardware errorIf the error continues after resetting the power, replace the ID Flag Sensor .
Operation Errors
Data Output
Flashing red No output Settings errorSet the Access address setting switches or Mode setting switches within the correct
ErrorCorrective action
ErrorCorrective action
range.
Section 6 Handling Errors
Flashing red OD6External Input errorThere are possibilities that external noise is applied or chattering or delay at the Input
lines.
Follow the instruction in the Chapter 4 Installation, Connections, and Wiring and
Errors and Countermeasures of this chapter.
RFID-related Errors
Data Output
Flashing red OD0RF Tag communication error :
Flashing red OD1Verify error :
Flashing red OD2No RF Tag error :
Flashing red OD3Address setting error :
Flashing red OD4Write protect error :
ErrorCorrective action
RF Tag was detected in
TRIGGER MODE but
communications could not be
ended normally.
Data was not correctly written to
RF Tag .
An RF T ag could not be d etected
in TRIGGER MODE.
The access address setting
switches set to a memory area
outside the RF Tag memory range.
Write operation executed to the
write-protected area of RF Tag.
Change the control timing so that communications can be started while the RF T ag is
within the Antenna's communications range.
Measure the noise and tak e suit ab le n oise co unte rmeasures .
Check the effect of surrounding metal and make sure that the desired
communications distance can be obtained.
Retry the writing process.
If the error persists, replace the RF Tag.
Change the control timing so that communications can be started while the RF T ag is
within the Antenna's communications range.
Measure the noise and tak e suit ab le n oise co unte rmeasures .
Check the effect of surrounding metal and make sure that the desired
communications distance can be obtained.
Set the Access address setting switches within the RF Tag memory range.
Execute the write operation to outside the write-protected area.
Disabled Write protect funct ion , if y o u do no t use write pr otec t funct ion .
70
Flashing red OD8RF Tag error 1 :
Flashing red OD9RF Tag error 2 :
Flashing red OD10RF Tag error 3 :
Flashing red OD5Hardware Data error :
Note. Flashing is turing on and off every 0.3sec.
RFID System
User's Manual
RF Tag used is not supported by
Change the RF Tag to one supported by the ID Flag Sensor.
the ID Flag Sensor.
RF Tag used is not supported by
the ID Flag Sensor.
RF Tag used is not supported by
the ID Flag Sensor.
Change the RF Tag data in the specified address except for all 0s or 1s.
Data in the specified address is
set to all 0s or 1s in the DATA
READ 2 MODE.
Page 73
Errors and Countermeasures
• Noise interference· · · · · · · · · · · · · Take adequate countermeasures against noise.
• External device failure
• ID Flag Sensor failure
• Others
· · · · · · Repairs are required.
1. Improvement in Grounding
2. Countermeasures Against Noise on Power Line
Noise filter
Twist the wires and do
not lay them out
parallel to power lines.
Other
device
Other
device
Ground at a
resistance less
than 100 Ω.
Power
supply
ID Flag Sensor
ID Flag Sensor
ID Flag Sensor
The four main causes of problems that may occur in the ID Flag Sensor are as follows:
 Noise Interference
If the system malfunctions due to noise, refer to the following table and take appropriate countermeasures.
No.Occurrence of faultPossible causeCountermeasure
An instantaneous voltage drop due to
inrush current to the heavy load.
Occurs when a heavy-duty motor,
1
transformer, or capacitor is turned ON.
2Occurs irregularly.Noise on power line
Malfunction such as input signal turn-
3
ing ON when it should be OFF.
Common mode noise as a result of the
above cause.
Inductive noise on input line
Increase the capacity of the power
supply and the size of the power cable.
• Provide the power through a 1-to-1
non-grounded insulating transformer.
• Do not use the same ground as other
large-capacity devices. Independently ground the Controller at a
resistance of 100 Ω or less. (See
figure1.)
Provide the power through a 1-to-1
non-grounded insulating transformer or
noise filter. (See figure 2.)
• Separate input signal from power
lines.
• If there is a lot of noise interference,
put the input line inside a grounded
metal conduit or use shielded cable.
Section 6
Troubleshooting
Section 6 Errors and Countermeasures
RFID System
User's Manual
71
Page 74
Section 6
Troubleshooting
Maintenance and Inspection
The ID Flag Sensor must be inspected on a daily or regular basis so that the functions can be used in good
condition. The ID Flag Sensor consists of semiconductors that last almost indefinitely. The following
malfunctions may, however, result due to the operating environment and conditions.
(1) Element deterioration due to overvoltage or overcurrent.
(2) Element deterioration due to continuous stress caused by high ambient temperature.
(3) Connector contact faults or insulation deterioration due to humidity and dust.
(4) Connector contact f aults or element corrosion due to corrosive gas.
 Inspection Items
No.ItemDetailCriteria
Supply voltage fluctuation
1
Ambient environment
(a) Temperature(a) Within the specified range(a) −10 to 55°C
Section 6 Maintenance and Inspection
(b) Humidity(b) Within the specified range(b) 25% to 85%
(c) Vibration and shock(c) Influence of vibration or impact of
2
(d) Dust(d) Check that the system is free of accumu-
(e) Corrosive gas(e) Check that no metal part of the system is
Panel condition
(a) Ventilation(a) Check that the system is ventilated prop-
3
(b) Damage to packing
for any enclosed
construction
I/O power supply
4
(a) Voltage fluctuation
(b) Ripple
5 Mounting condition
6RF Tag life
(1) Check that the supply voltage fluctuation
at the power supply terminal block is within
the permissible range.
(2) Check that there are no frequent instanta-
neous power failures or radical voltage
fluctuations.
machines
lated dust and foreign particles.
discolored or corroded.
erly with natural ventilation, forced ventilation, or cooling air.
(b) Check that the panel packing is properly
attached with no damage.
Check on the I/O terminal block that the voltage fluctuation and ripple are within the permissible ranges.
(1) Check that each device is securely
mounted.
(2) Check that each connector is fully
inserted.
(3) Check that no wire is broken or nearly bro-
ken.
(4) Check that the distance between the RF
Tag and Antenna is within the specified
range.
Manage the number of times the RF Tag has
been written
Within supply voltage specified range
Within permissible voltage
fluctuation range
(c) Within the specified
range
(d) Neither is permitted.
(e) Neither is permitted.
(a) The interior temperature
must be within a range
between −10 and 55°C
with proper ventilation.
(b) The packing must have
no damage.
Within the specified range
No loose screws
Each connector must be
locked or securely tightened
with screws.
Must be no wire that is broken or nearly broken.
Within the specified range
Do not allow the specified
maximum number of overwrites to be exceeded.
Required
equipment
Multimeter
Power supply
analyzer
Maximum and
minimum thermometer
Hygrometer
---
Multimeter
Oscilloscope
---
---
---
---
---
72
RFID System
User's Manual
Page 75
Section 7
Appendices
Product Specifications74
Characteristics104
Reference Data: Antenna and RF Tags Installation133
RF Tag Memory Capacities and Memory Types165
RF Tag Memory Map166
Chemical Resistance of the Antennas and RF Tags167
V600-Compatible Mode173
Degree of Protection188
Section 7 Appendices
RFID System
User's Manual
73
Page 76
Section 7
Appendices
Product Specifications
ID Flag Sensor
 General Specifications
V680-HAM91/-HAM81
ItemModel
Supply voltage24 VDC +10%/-15%, Ripple (p-p): 10% max.
Power consumption3.5 W max. (supply voltage: 24 VDC, current consumption: 0.15A Max., not included I/O Interface
Shock resistance
Dimensions
Degree of protectionIP40 (IEC60529)
MaterialPC + ABS
Section 7 Product Specifications
WeightApprox. 130 g
Mounting methodDIN Track
-10 to 55°C (with no icing)
-25 to 65°C (with no icing)
25% to 85% (with no condensation)
20 MΩ min. (at 500 VDC) between terminals(except for FG) and casing
1,000 VAC, 50/60Hz for 1 min between terminals(except for FG) and casing
10 to 150 Hz, 0.2-mm double amplitude, acceleration: 15m/s
down, left/right, and forward/backward) for 8 minutes each
2
150 m/s
90 × 30 × 65 mm (excluding protruding parts)
, 3 times each in 6 directions (Total: 18 times)
V680-HAM91/V680-HAM81
2
, 10 sweeps in each 3 directions (up/
 Interface cable
V680-A60 2M/5M/10M
Specifications
Interface cable
(Connector : 26pins)
The interface cable connector is not waterproof.
The maximum cable length is 10 m.
cable lengthmodel
2mV680-A60 2m
5mV680-A60 5m
10mV680-A60 10m
74
RFID System
User's Manual
Page 77
 I/O Specifications
DC24V
IN
Tr
8.2kΩ
0V
Main
Circuit
Main
Circuit
OUT
0V
DC24V
IN
Tr
8.2kΩ
0V
Main
Circuit
Main
Circuit
DC24V
0V
OUT
Section 7
Appendices
Item
Input
Output
 I/O Circuit Diagram
V680-HAM91
Input CircuitOutput Circuit
V680-HAM81
Input CircuitOutput Circuit
V680-HAM91V680-HAM81
Transistor output or contact output
Short-circuit current: 3 mA (typical) (Input terminal and 0-V short-circuit)
OFF voltage: 15 to 30 VDC
ON voltage: 0 to 5 VDC
Input impedance: 8.2 kΩ
Applied voltage: 30 VDC max.
NPN open collector,
20 mA max. at 30 VDC,
residual voltage: 2 V max.
PNP open collector,
20 mA max. at 30 VDC,
residual voltage: 2 V max.
Section 7 Product Specifications
INPUT/OUTPUT controls
• When using a solid-state output with the maximum switching current rating over 1A , there is a possibility of causing
External Input Errors due to the delay of rise /fall time of output signal. Consider this when selecting the solid-state
output.
• When using a contact output, consider chattering and the minimum switching current.
• When connecting an inductive load or an electrical device that tends to generate noise to the output, connect a diode
in parallel with the load. Connect the cathode side of the diode to the positive side of the power supply.
RFID System
User's Manual
75
Page 78
Section 7
8.7
74.8
71.8
65.75
61.75
4-switch
30
14.74
21-Status Indicator
7×2.1=14.7
4-switch
18.95
30.25
41.55
52.85
108.26
90
Connector
65
12
(5.5)
Connector
38.5
(Unit : mm)
(Unit : mm)
32
20±5
20±5
20±5
20±5
35±5
14.4
1
6.1
37.6
Connector : XG5M-2632-N
Vinyl-insulated round cord 9 mm dia,
23-conductor cable (7/0.2 mm dia. : AWG24)
The interface cable connector is not waterproof.
The maximum cable length is 10 m.
Appendices
 Dimensions
V680-HAM91/-HAM81
Section 7 Product Specifications
 Interface cable
V680-A60 2M/5M/10M
76
RFID System
User's Manual
Page 79
Appendices
(16.8 dia.)
(Unit: mm)
(14.5 dia.)
12
9.6 dia.
Connector
Ferrite core
50
25
Two toothed washers
Two lock nuts
Coaxial cable, 2.9 dia.,
standard length: 2 m
15
35
33
24
7
M12 x 1
21 dia.
12.5 dia.
17
Mounting Hole Dimensions
Insulation cover
Antenna
Four models of Antennas can be used with ID Slave. Select the best Antenna for the application.
 V680-HS51
 General Specifications
ItemModelV680-HS51
Ambient operating
temperature
Ambient storage
temperature
Ambient operating
humidity
Insulation resistance20 MΩ min. (at 500 VDC) between cable terminals and case
Dielectric strength1,000 VAC, 50/60Hz for 1 min between cable terminals and case
Degree of protectionIP67 (IEC60529)
Vibration resistance10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s
Shock resistance1,000 m/s
DimensionsM12 × 35 mm
MaterialABS, brass, and epoxy resin filling
WeightApprox. 55 g
Cable lengthStandard length of 2 m
−10 to 60°C (with no icing)
−25 to 75°C (with no icing)
35% to 95% (with no condensation)
Oil resistance equivalent to IP67g according to the former JEM standard. (Read/Write Antenna
portion)
Note: The Connector is not waterproof.
2
, 10 sweeps in each of
3 directions (up/down, left/right, and forward/backward) for 15 minutes each
2
, 3 times each in 6 directions (Total: 18 times)
Section 7
Section 7 Product Specifications
 Dimensions
Case materialBrass
Communications surfaceABS resin
Filling resinEpoxy resin
CablePVC (black)
RFID System
User's Manual
77
Page 80
Section 7
Appendices
 V680-HS52-W/R
 General Specifications
ItemModelV680-HS52-W
(Standard cable, waterproof connector)
Ambient operating
temperature
Ambient storage
temperature
Ambient operating
humidity
Insulation resistance20 MΩ min. (at 500 VDC) between cable terminals and the case
Dielectric strength1,000 VAC, 50/60 Hz for 1 min between cable terminals and case
Degree of protectionIP67 (IEC 60529)
Vibration resistance10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s
Shock resistance500 m/s
DimensionsM22 × 65 mm
MaterialABS resin, brass, and epoxy resin filler
WeightApprox. 850 g (with 12.5-m cable)
Cable lengthStandard lengths of 2 and 12.5 m
−10 to 60°C (with no icing)
−25 to 75°C (with no icing)
35% to 95% (with no condensation)
Oil resistance equivalent to IP67g according to the
former JEM standard.
Note: The connector specifications are IP67 and
IP65 (IEC 60529).
down, left/right, and forward/backward) for 8 minutes each
2
, 3 times each in 6 directions (Total: 18 times)
(See Note.)
V680-HS52-R
(Flexible cable, non-waterproof connector)
IP67 (IEC 60529)
Oil resistance equivalent to IP67g according to the
former JEM standard.
Note: The connectors are not waterproof.
2
, 1 sweep in each 3 directions (up/
Note : The ID Flag Sensor is not waterproof. Do not use it in an environment where mist is present.
Section 7 Product Specifications
78
RFID System
User's Manual
Page 81
 Dimensions
16.8 dia.
(Unit: mm)
14.5 dia.
Connector
Ferrite core
Insulation cover
37
50
30
16.5 dia.
Two toothed washers
Two lock nuts
M22 × 1
Operation indicator
Coaxial cable, 5.5 dia.,
standard length: 2 m
65
57
50
47.8
7
35 dia.
Antenna
22.5 dia.
Mounting Hole Dimensions
30
19.8 dia.
V680-HS52-W
Section 7
Appendices
V680-HS52-R
Mounting Hole Dimensions
30
22.5 dia.
Antenna
35 dia.
Case materialBrass
Communications surfaceABS resin
Filling resinEpoxy resin
CablePVC (gray)
Section 7 Product Specifications
Two toothed washers
Two lock nuts
M22 × 1
Operation indicator
Ferrite core
(39.5)
7
16.5 dia.
30
50
47.6
50
57
65
Coaxial cable, 5.3 dia.,
standard length: 2 m
(Unit: mm)
Connector
16.8 dia.
14.5 dia.
Insulation cover
Case materialBrass
Communications surfaceABS resin
Filling resinEpoxy resin
CablePVC (black)
RFID System
User's Manual
79
Page 82
Section 7
Appendices
 V680-HS63-W/R
 General Specifications
ItemModelV680-HS63-W
(Standard cable, waterproof connector)
Ambient operating
temperature
Ambient storage
temperature
Ambient operating
humidity
Insulation resistance20 MΩ min. (at 500 VDC) between cable terminals and case
Dielectric strength1,000 VAC, 50/60 Hz for 1 min between cable terminals and case
Degree of protectionIP67 (IEC 60529)
Vibration resistance10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s
Shock resistance500 m/s
Dimensions40 × 53 × 23 mm
MaterialABS resin case, epoxy resin filler
WeightApprox. 850 g (with 12.5-m cable)
Cable lengthStandard lengths of 2 and 12.5 m
−10 to 60°C (with no icing)
−25 to 75°C (with no icing)
35% to 95% (with no condensation)
Oil resistance equivalent to IP67g according to the
former JEM standard.
Note: The connector specifications are IP67 and
IP65 (IEC 60529).
down, left/right, and forward/backward) for 11 minutes each
2
, 3 times each in 6 directions (Total: 18 times)
(See Note.)
V680-HS63-R
(Flexible cable, non-waterproof connector)
IP67 (IEC 60529)
Oil resistance equivalent to IP67g according to the
former JEM standard.
Note: The connectors are not waterproof.
2
, 10 sweeps in each of 3 directions up/
Note : The ID Flag Sensor is not waterproof. Do not use it in an environment where mist is present.
Section 7 Product Specifications
80
RFID System
User's Manual
Page 83
 Dimensions
(Unit: mm)
Connector
Ferrite core
Insulation cover
37
50
30
16.5 dia.
Coaxial cable, 5.5 dia.,
standard length: 2 m
Operation indicator
16.8 dia.
14.5 dia.
Two, M4 or 4.5-dia. holes
Antenna
53
27
6
5
Coil center
Note: Mounting Hole Dimensions
40
5
28±0.1
16.8 dia.
(Unit: mm)
14.5 dia.
Connector
Ferrite core
Insulation cover
37
50
30
16.5 dia.
Coaxial cable, 5.3 dia.,
standard length: 2 m
Operation indicator
Antenna
Note: Mounting Hole Dimensions
Coil center
Two, M4 or 4.5-dia. holes
40
28±0.1
53
27
6
5
5
V680-HS63-W
Section 7
Appendices
Case materialABS resin
Filling resinEpoxy resin
CablePVC (gray)
Section 7 Product Specifications
V680-HS63-R
Case materialABS resin
Filling resinEpoxy resin
CablePVC (black)
RFID System
User's Manual
81
Page 84
Section 7
Appendices
 V680-HS65-W/R
 General Specifications
ItemModelV680-HS65-W
(Standard cable, waterproof connector)
Ambient operating
temperature
Ambient storage
temperature
Ambient operating
humidity
Insulation resistance20 MΩ min. (at 500 VDC) between cable terminals and case
Dielectric strength1,000 VAC, 50/60 Hz for 1 min between connector terminals and case
Degree of protectionIP67 (IEC 60529)
Vibration resistance10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s
Shock resistance500 m/s
Dimensions100 × 100 × 30 mm
MaterialABS resin case, epoxy resin filler
WeightApprox. 1,100 g (with 12.5-m cable)
Cable lengthStandard lengths of 2 and 12.5 m
−25 to 70°C (with no icing)
−40 to 85°C (with no icing)
35% to 95% (with no condensation)
IP67 (IEC 60529)
Oil resistance equivalent to IP67g according to the
former JEM standard.
Note: The connector specifications are IP67 and
IP65 (IEC 60529).
down, left/right, and forward/backward) for 11 minutes each
2
, 3 times each in 6 directions (Total: 18 times)
(See Note.)
Oil resistance equivalent to IP67g according to the
former JEM standard.
Note: The connectors are not waterproof.
V680-HS65-R
(Flexible cable, non-waterproof connector)
2
, 10 sweeps in each of 3 directions up/
Note : The ID Flag Sensor is not waterproof. Do not use it in an environment where mist is present.
Section 7 Product Specifications
82
RFID System
User's Manual
Page 85
 Dimensions
16.8 dia.
(Unit: mm)
14.5 dia.
Connector
Ferrite core
Insulation cover
37
50
30
16.5 dia.
Coaxial cable, 5.5 dia.,
standard length: 2 m
Operation
indicator
100
90±0.2
90±0.2
100
50
5
5
30
20
10
10
50
Bushing
Four, 4.5 dia.
(Mounting holes)
11
16.8 dia.
(Unit: mm)
14.5 dia.
Connector
Ferrite core
Insulation cover
37
50
16.5 dia.
Coaxial cable, 5.3 dia.,
standard length: 2 m
Bushing
Four, 4.5 dia.
(Mounting holes)
Operation
indicator
100
90±0.2
90±0.2
100
50
5
5
30
20
10
10
50
11
V680-HS65-W
Section 7
Appendices
V680-HS65-R
Case materialABS resin
Filling resinEpoxy resin
CablePVC (gray)
Case materialABS resin
Filling resinEpoxy resin
CablePVC (black)
Section 7 Product Specifications
RFID System
User's Manual
83
Page 86
Section 7
Appendices
RF Tags
 V680-D1KP52MT
 General Specifications
ItemModelV680-D1KP52MT
Memory capacity1,000 bytes (user area)
Memory typeEEPROM
Data Retention10 years after writing (85°C or less), 0.5 years after writing (85 to 125°C)
Total data retention at high temperatures exceeding 125°C is 10 houres (See note.)
Write Endurance100,000 times per block (25°C)
Ambient operating
temperature when
communicating
Ambient storage
temperature (with data
retention)
Ambient operating
humidity
Degree of protectionIP68 (IEC 60529)
Vibration resistance10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s
Shock resistance500 m/s
Dimensions8 dia. × 5 mm
MaterialsCase: PPS resin, Filling resin: Epoxy resin
WeightApprox. 0.5 g
Section 7 Product Specifications
Metal countermeasuresYes
Note: After string data at high temperatures, rewrite the data even if changes are not required, high temperatures are those
exceeding 125°C up to 180°C.
−25 to 85°C (with no icing)
−40 to 125°C (with no icing)
35% to 95%
Oil resistance equivalent to IP67g according to the former JEM standard.
2
, 10 sweeps each in X, Y, and Z
directions for 15 minutes each
2
, 3 times each in X, Y, and Z directions (Total: 18 times)
84
RFID System
User's Manual
Page 87
 Dimensions
R0.2
8
dia.
0
−0.1
5
0
−0.1
(Unit: mm)
When embedding the V680-D1KP52MT into a metal surface, use the V680-HS51, V680-HS52 Antenna.
Transmission will not be possible if the V680-HS63 Antenna is used.
The side with the markings is the communications surface. Mount the RF Tag with this side facing the Antenna.
Section 7
Appendices
Case materialPPS resin
Filling resinEpoxy resin
The ID code is written in the memory of the RF Tag and may be affected by data retention characteristics at high
temperatures. Take suitable precautions when using the READ ID command for RF Tags operating at high
temperatures.
 RF Tag Heat Resistivity
• Storing RF Tags under high temperatures will adversely affect the performance of the internal parts
and the service life of the RF Tags.
• An LTPD of 10% was determined during the evaluation for RF Tags that reached the end of their life
after testing under the following test conditions.
Heat cycle−10°C/150°C, 30 minutes each for 1,000 cycles
−10°C/180°C, 30 minutes each for 200 cycles
High temperatures150°C 1,000 hours
180°C, 200 hours
LTPD: Lot tolerance percent defective
The lower limit of the malfunction rate for lots to be considered unacceptable during reliability testing.
Section 7 Product Specifications
RFID System
User's Manual
85
Page 88
Section 7
Appendices
 V680-D1KP52M-BT01
 General Specifications
ItemModelV680-D1KP52M-BT01
Memory capacity1,000 bytes (user area)
Memory typeEEPROM
Data Retention10 years after writing (85°C or less), 0.5 years after writing (85 to 125°C)
Total data retention at high temperatures exceeding 125°C is 10 houres (See note.)
Write Endurance100,000 times per block (25°C)
Ambient operating
temperature when
communicating
Ambient storage
temperature (with data
retention)
Ambient operating
humidity
Degree of protectionIP68 (IEC 60529)
Vibration resistance10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s
Shock resistance500 m/s
DimensionsHex Head: 17 HEX × 9.5 mm, Screw: M10 × 10 mm
MaterialsBolt: SUS303, Case(RF Tag): PPS resin, Filling resin(RF Tag): Epoxy resin
WeightApprox. 25 g
Metal countermeasuresYes
−25 to 85°C (with no icing)
−40 to 125°C (with no icing)
35% to 95%
Oil resistance equivalent to IP67g according to the former JEM standard.
directions for 15 minutes each
2
, 3 times each in X, Y, and Z directions (Total: 18 times)
2
, 10 sweeps each in X, Y, and Z
Section 7 Product Specifications
 Dimensions
15-30
RF T ag
(19.6)
17
The side with the markings is the communications surface. Mount the RF Tag with this side facing the Antenna.
The ID code is written in the memory of the RF Tag and may be affected by data retention characteristics at high
temperatures. Take suitable precautions when using the READ ID command for RF Tags operating at high
temperatures.
ItemModelV680-D1KP52M-BT11
Memory capacity1,000 bytes (user area)
Memory typeEEPROM
Data Retention10 years after writing (85°C or less), 0.5 years after writing (85 to 125°C)
Total data retention at high temperatures exceeding 125°C is 10 houres (See note.)
Write Endurance100,000 times per block (25°C)
Ambient operating
temperature when
communicating
Ambient storage
temperature (with data
retention)
Ambient operating
humidity
Degree of protectionIP68 (IEC 60529)
Vibration resistance10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s
Shock resistance500 m/s
DimensionsHex Head: 13 HEX × 7 mm, Screw: M8 × 10 mm
MaterialsBolt: SUS303, Case(RF Tag): PPS resin, Filling resin(RF Tag): Epoxy resin
WeightApprox. 10 g
Metal countermeasuresYes
−25 to 85°C (with no icing)
−40 to 125°C (with no icing)
35% to 95%
Oil resistance equivalent to IP67g according to the former JEM standard.
directions for 15 minutes each
2
, 3 times each in X, Y, and Z directions (Total: 18 times)
Section 7
Appendices
2
, 10 sweeps each in X, Y, and Z
Section 7 Product Specifications
 Dimensions
The side with the markings is the communications surface. Mount the RF Tag with this side facing the Antenna.
The ID code is written in the memory of the RF Tag and may be affected by data retention characteristics at high
temperatures. Take suitable precautions when using the READ ID command for RF Tags operating at high
temperatures.
RF T ag
(15)
13
Bolt
15-30
6 dia.
M8-P1.25
C1.5
0.1 710
19.1
Bolt materialSUS303
Case material (RF Tag)PPS resin
Filling resin (RF Tag)Epoxy resin
(Unit: mm)
RFID System
User's Manual
87
Page 90
Section 7
C0.5
6-R0.8
10 dia.
4.5
Appendices
 V680-D1KP53M
 General Specifications
ItemModelV680-D1KP53M
Memory capacity1,000 bytes (user area)
Memory typeEEPROM
Data Retention10 years after writing (85°C or less), 0.5 years after writing (85 to 125°C)
Write Endurance100,000 times per block (25°C)
Ambient operating
temperature when
communicating
Ambient storage
temperature (with data
retention)
Ambient operating
humidity
Degree of protectionIP68 (IEC 60529)
Vibration resistance10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s
Shock resistance500 m/s
Dimensions10 dia. × 4.5 mm (DIN698373)
MaterialsCase: PPS resin, Filling resin: Epoxy resin
WeightApprox. 1.0 g
Metal countermeasuresYes
−25 to 85°C (with no icing)
−40 to 125°C (with no icing)
35% to 95%
Oil resistance equivalent to IP67g according to the former JEM standard.
directions for 15 minutes each
2
, 3 times each in X, Y, and Z directions (Total: 18 times)
2
, 10 sweeps each in X, Y, and Z
Section 7 Product Specifications
 Dimensions
Case materialPPS resin
Filling resinEpoxy resin
When embedding the V680-D1KP53M into a metal surface, use the V680-HS51, V680-HS52 Antenna.
Transmission will not be possible if the V680-HS63 Antenna is used.
The side with the markings is the communications surface. Mount the RF Tag with this side facing the Antenna.
88
RFID System
User's Manual
Page 91
Section 7
z V680-D1KP66MT
z V680-D1KP66T
Appendices
 V680-D1KP66T/-D1KP66MT
 General Specifications
ItemModelV680-D1KP66TV680-D1KP66MT
Memory capacity1,000 bytes (user area)
Memory typeEEPROM
Data Retention10 years after writing (85°C or less), 2.5 years after writing (85 to 125°C)
Total data retention at high temperatures exceeding 125°C is 10 houres (See note.)
Write Endurance100,000 times per block (25°C)
Ambient operating
temperature when
communicating
Ambient storage
temperature (with data
retention)
Ambient operating
humidity
Degree of protectionIP68 (IEC 60529)
Vibration resistance10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s
Shock resistance500 m/s
Dimensions34 × 34 × 3.5 mm
MaterialsCase: PPS resin
WeightApprox. 6 gApprox. 7.5 g
Metal countermeasuresNoneYes
Note: After string data at high temperatures, rewrite the data even if changes are not required, high temperatures are those
exceeding 125°C up to 180°C.
−25 to 85°C (with no icing)
−40 to 125°C (with no icing)
35% to 95%
Oil resistance equivalent to IP67g according to the former JEM standard.
2
, 10 sweeps each in X, Y, and Z
directions for 15 minutes each
2
, 3 times each in X, Y, and Z directions (Total: 18 times)
Section 7 Product Specifications
The V680-D1KP66MT is designed to be mounted directly to metal. The V680-D1KP66T and V680D1KP66MT markings are shown in the f ollowing diagrams.
The side with the markings is the communications surface. Mount the RF Tag with this side facing the Antenna.
The ID code is written in the memory of the RF Tag and may be affected by data retention characteristics at high
temperatures. Take suitable precautions when using the READ ID command for RF Tags operating at high
temperatures.
RFID System
User's Manual
89
Page 92
Section 7
(Unit: mm)
25±0.2
Four, R8
Four, R4
34
32
32
34
25±0.2
35±0.1
Two, M3
25±0.2
25±0.2
Two, 3.5 dia.
Two, 6 dia.
Mouting Hole Dimensions
(Unit: mm)
25±0.2
Two, 4 dia.
Four, R5.5
34
37
37
34
25±0.2
Two, M3
25±0.2
25±0.2
15
15
10
16
3.5
4
Appendices
 Dimensions
V680-D1KP66T/-D1KP66MT
V600-A86 Attachment
Case materialPPS resin
Section 7 Product Specifications
Case materialPPS resin
 RF Tag Heat Resistivity
• Storing RF Tags under high temperatures will adversely affect the performance of the internal parts
and the service life of the RF Tags.
• An LTPD of 10% was determined during the evaluation for RF Tags that reached the end of their life
after testing under the f o llowing test conditions.
Heat cycle−10°C/150°C, 30 minutes each fo r 1,000 cycles
−10°C/180°C, 30 minutes each for 200 cycles
High temperatures150°C 1,000 hours
180°C, 200 hours
LTPD: Lot tolerance percent defective
The lower limit of the malfunction rate for lots to be considered unacceptable during reliability testing.
RFID System
90
User's Manual
Page 93
 V680-D1KP66T-SP
Mounting Hole Dimensions
(Unit: mm)
80±0.2
Four, R6
34
36.5
34
Two, M5
80±0.2
95
1.3
6.5
2.5
max.
Two, 5.5 dia.
(Mounting hole)
 General Specifications
ItemSpecifications
Memory capacity1,000 bytes
Memory typeEEPROM
Data Retention10 years after writing (85°C or less)
Write Endurance100,000 times per block (25°C)
Ambient operating
temperature
Ambient operating
humidity
Ambient storage
temperature
Ambient storage humidity 35% to 95% (with no condensation)
Vibration resistance10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s
Shock resistance500 m/s
Dimensions95 × 36.5 × 6.5 mm (excluding protruding parts)
Degree of protectionIP67
MaterialExternal coating: Fluororesin (PFA)
WeightApprox. 20 g
Mounting methodTwo M5 screws
Metal countermeasuresNone
When communicating: −25 to 70°C (with no icing)
When not communicating: −40 to 110°C (with no icing)
35% to 95% (with no condensation)
−40 to 110°C (with no icing)
directions for 15 minutes each
2
, 3 times each in 6 directions (Total: 18 times)
RF Tag body: PPS resin
Section 7
Appendices
2
, 10 sweeps each in X, Y, and Z
The side with the markings is the communications surface. Mount the RF Tag with this side facing the Antenna.
 Dimensions
Section 7 Product Specifications
Case materialPFA resin
RFID System
User's Manual
91
Page 94
Section 7
䋨60 dia.䋩
80 dia.
14 dia.
10±0.2
7.51.25
䋨1.25䋩
䋨5°䋩
䋨5°䋩
18 dia.
Two, R1
(Unit: mm)
Case material PPS resin
Mounting Hole Dimensions
20 dia.
M12
M12
4050
11.5
15
110
3.2 dia.
12 dia.
17
2
1
Nuts (M12):
Provided Parts
Split pin (3.2 × 20 mm):
(Unit: mm)
Appendices
 V680-D1KP58HTN
• General Specifications
ItemModelV680-D1KP58HTN
Memory capacity1,000 bytes (user area)
Memory typeEEPROM
Data Retention10 years after writing (85°C or less), 0.5 years after writing (85°C to 125°C)
Total data retention at high temperatures exceeding 125°C is 10 hours
Write Endurance100,000 times per block (25°C)
Ambient operating temperature
Ambient storage temperature-40 to 250°C (with no icing)
Ambient operating humidity35% to 95%
Degree of protectionIP67 (IEC 60529)
Vibration resistance
Shock resistance500 m/s
MaterialsCoatiog: PPS resin
WeightApprox. 70 g
-25 to 85°C (with no icing)
(Data retention: -40 to 125°C)
Oil resistance equivalent to IP67g according to the former JEM standard.
10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s
and Z directions for 15 minutes each
2
, 3 times each in X, Y, and Z directions (Total: 18 times)
2
,10 sweeps each in X, Y,
• Dimensions
V680-D1KP58HTN
Section 7 Product Specifications
V680-A80 (Attachment)
This Attachment is specifically designed to secure V680-D1KP58HTN RF Tags to the workpiece.
Applicable RF Tag model: V680-D1KP58HTN
92
RFID System
User's Manual
Page 95
Section 7
1 hour
at 2
5°
C
1 hour
at 25°C
3 hours
at 25°C
2 hours
at 25°C
1 hours
at 25°C
3 hours
at 25°C
㪘㪺㪺㫌㫄㫌㫃㪸㫋㪼㪻㩷㫋㫀㫄㪼䋺㩷㪈㩷㪿㫆㫌㫉
㪘㪺㪺㫌㫄㫌㫃㪸㫋㪼㪻㩷㫋㫀㫄㪼䋺㩷㪋㩷㪿㫆㫌㫉㫊
㪮㫉㫀㫋㫀㫅㪾㩷㪻㪸㫋㪸㩷㫋㫆㩷㫋㪿㪼㩷㪩㪝㩷㫋㪸㪾㩷
㫄㪼㫄㫆㫉㫐㩷㫀㫅㩷㫌㫊㪼㪅
Reset the data
retention time.
Leaving time other than high temperature environment
is not included in the cumulative time used.
*1.
*1. High temperatures are those exceeding 125°C up to 250°C.
Reset the data
retention time.
Fig. Concept of resetting the data retention time
1 hour at high
temperatures
*1.
3 hours at high
temperatures
2 hours at high
temperatures
*1.*1.
3 hours at high
temperatures
2 hours at high
temperatures
*1.
㪘㪺㪺㫌㫄㫌㫃㪸㫋㪼㪻㩷㫋㫀㫄㪼䋺㩷㪍㩷㪿㫆㫌㫉㫊
㪘㪺㪺㫌㫄㫌㫃㪸㫋㪼㪻㩷㫋㫀㫄㪼䋺㩷㪐㩷㪿㫆㫌㫉㫊
㪘㪺㪺㫌㫄㫌㫃㪸㫋㪼㪻㩷㫋㫀㫄㪼䋺㩷㪋㩷㪿㫆㫌㫉㫊
Appendices
 Use at high temperatures (V680-D1KP58HTN)
Data retention
•Data stored in memory in the RF Tag may be lost due to the characteristics of EEPROM, if the accumulated usage time of the RF Tag at a high temperature over 125
°
C exceeds 10 hours after writing data to
the RF Tag. Reset the data retention time before the accumulated usage time exceeds 10 hours.
•An error in communications between the Antenna and the RF Tag may occur in an environment where
the ambient operating temperature is 85
the RF Tag in an environment where the ambient operating temperature is 85
°
C or higher. Do not communicate between the Antenn a and
°
C or higher.
•The UID (unique identification number for each RF Tag) may be lost due to the characteristics of
EEPROM when the RF tag is used at a high temperature over 125°C. Do not use the commands
using UID at a high temperature over 125°C.
•Accumulated time
•Resetting the data retention time
<When using 3 Bytes from the RF Tag addresses 0120Hex.>
1.Reading 3 Bytes of data from the RF tag addresses 0120Hex.
(4-byte Access Mode)
2.Read data written to 3 Bytes of data from the RF tag
addresses 0120Hex.
(4-byte Access Mode)
<RF tag memory>
011F
0120
0121
0122
0123
Data retention is reset only data written to the RF tag address.
If you reset the data retention, writes the same data to all of the tag memory in use.
Read data written to the RF
tag memory in use.
Hex
Hex
Hex
Hex
Hex
12
78
AB
Hex
Hex
Hex
Reading data from the RF
tag memory in use.
<RF tag memory>
Hex
011F
0120
0121
0122
0123
Hex
Hex
Hex
Hex
AB
12
78
Hex
Hex
Hex
Section 7 Product Specifications
RFID System
User's Manual
93
Page 96
Section 7
Appendices
 Heat Resistance
Storing RF Ta gs under high temperatures or heat cycle will adversely affect the performance of the
internal parts and the service life of the RF Tags.
Correct operation has been confirmed through the OMRON in-house evaluation for RF Tags under the
following high-temperature conditions.
1) 2,000 cycles, where 1 cycle is each 30-minute at Room temperature and 200°C
2) 250°C, 500 hours
• The controller’s setting
Please set the latest ID controller to the CA1D mode and use it when the latest ID controller is used
together with the old model ID controller Model V680 -CA1D/-CA2D.
RF Tag
Controller
V680-CA1D/-CA2D onlyNot requiredNot requiredNot required
C680-CA1D/-CA2D and the latest
ID controller used together
The latest ID controller onlyNot requiredNot requiredNot required
ItemModelV680-D2KF52M
Memory capacity2,000 bytes (user area)
Memory typeFRAM
Data Retention10 years after writing (55°C or less), 2.9 years after writing (85°C max.)
Write Endurance10 billion times per block. Access frequency (See note): 10 billion times
Ambient operating
temperature
Ambient storage
temperature
Ambient operating
humidity
Degree of protectionIP67 (IEC 60529)
Vibration resistance10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s
Shock resistance500 m/s
Dimensions8 dia. × 5 mm
MaterialsCase: PPS resin, Filling resin: Epoxy resin
WeightApprox. 0.5 g
Metal countermeasuresYes
Note: The total communications frequency of the Read or Write is called an access frequency.
−25 to 85°C (with no icing)
−40 to 85°C (with no icing)
35% to 95%
Oil resistance equivalent to IP67g according to the former JEM standard.
directions for 15 minutes each
2
, 3 times each in X, Y, and Z directions (Total: 18 times)
Section 7
Appendices
2
, 10 sweeps each in X, Y, and Z
 Dimensions
When embedding the V680-D1KP52MT into a metal surface, use the V680-HS51, V680-HS52 Antenna.
Transmission will not be possible if the V680-HS63 Antenna is used.
The side with the markings is the communications surface. Mount the RF Tag with this side facing the Antenna.
0
dia.
8
−0.1
(Unit: mm)
R0.2
0
5
−0.1
Case materialPPS resin
Filling resinEpoxy resin
Section 7 Product Specifications
RFID System
User's Manual
95
Page 98
Section 7
Appendices
 V680-D2KF52M-BT01
 General Specifications
ItemModelV680-D2KF52M-BT01
Memory capacity2,000 bytes (user area)
Memory typeFRAM
Data Retention10 years after writing (55°C or less), 2.9 years after writing (85°C max.)
Write Endurance10 billion times per block. Access frequency (See note): 10 billion times
Ambient operating
temperature
Ambient storage
temperature
Ambient operating
humidity
Degree of protectionIP67 (IEC 60529)
Vibration resistance10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s
Shock resistance500 m/s
DimensionsHex Head: 17 HEX × 9.5 mm, Screw: M10 × 10 mm
MaterialsBolt: SUS303, Case(RF Tag): PPS resin, Filling resin(RF Tag): Epoxy resin
WeightApprox. 25 g
Metal countermeasuresYes
Note: The total communications frequency of the Read or Write is called an access frequency.
−25 to 85°C (with no icing)
−40 to 85°C (with no icing)
35% to 95%
Oil resistance equivalent to IP67g according to the former JEM standard.
directions for 15 minutes each
2
, 3 times each in X, Y, and Z directions (Total: 18 times)
2
, 10 sweeps each in X, Y, and Z
Section 7 Product Specifications
 Dimensions
The side with the markings is the communications surface. Mount the RF Tag with this side facing the Antenna.
RF T ag
(19.6)
17
Bolt
15-30
8.4 dia.
M10-P1.5
C1.5
0.19.510
21.6
Bolt materialSUS303
Case material (RF Tag)PPS resin
Filling resin (RF Tag)Epoxy resin
(Unit: mm)
96
RFID System
User's Manual
Page 99
 V680-D2KF52M-BT11
13
(15)
RF T ag
0.1 710
19.1
6 dia.
M8-P1.25
C1.5
15-30
(Unit: mm)
Bolt
 General Specifications
ItemModelV680-D2KF52M-BT11
Memory capacity2,000 bytes (user area)
Memory typeFRAM
Data Retention10 years after writing (55°C or less), 2.9 years after writing (85°C max.)
Write Endurance10 billion times per block. Access frequency (See note): 10 billion times
Ambient operating
temperature
Ambient storage
temperature
Ambient operating
humidity
Degree of protectionIP67 (IEC 60529)
Vibration resistance10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s
Shock resistance500 m/s
DimensionsHex Head: 13 HEX × 7 mm, Screw: M8 × 10 mm
MaterialsBolt: SUS303, Case(RF Tag): PPS resin, Filling resin(RF Tag): Epoxy resin
WeightApprox. 10 g
Metal countermeasuresYes
Note: The total communications frequency of the Read or Write is called an access frequency.
−25 to 85°C (with no icing)
−40 to 85°C (with no icing)
35% to 95%
Oil resistance equivalent to IP67g according to the former JEM standard.
directions for 15 minutes each
2
, 3 times each in X, Y, and Z directions (Total: 18 times)
Section 7
Appendices
2
, 10 sweeps each in X, Y, and Z
 Dimensions
The side with the markings is the communications surface. Mount the RF Tag with this side facing the Antenna.
Section 7 Product Specifications
Bolt materialSUS303
Case material (RF Tag)PPS resin
Filling resin (RF Tag)Epoxy resin
RFID System
User's Manual
97
Page 100
Section 7
z V680-D2KF67M
z V680-D2KF67
Appendices
 V680-D2KF67/-D2KF67M
 General Specifications
ItemModelV680-D2KF67V680-D2KF67M
Memory capacity2,000 bytes (user area)
Memory typeFRAM
Data Retention10 years after writing (55°C or less), 2.9 years after writing (85°C max.)
Write Endurance10 billion times per block. Access frequency (See note.): 10 billion times
Ambient operating
temperature
Ambient storage
temperature
Ambient operating
humidity
Degree of protectionP67 (IEC 60529)
Vibration resistance10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s
Shock resistance500 m/s
Dimensions40 × 40 × 4.5 mm
MaterialsCase: PBT resin
WeightApprox. 6.5 gApprox. 7 g
Metal countermeasuresNoneYes
Note: The total communications frequency of the Read or Write is called an access frequency.
−25 to 85°C (with no icing)
−40 to 85°C (with no icing)
35% to 85%
Oil resistance equivalent to IP67g according to the former JEM standard.
2
directions for 15 minutes each
2
, 3 times each in X, Y, and Z directions (Total: 18 times)
,10 sweeps each in X, Y, and Z
Section 7 Product Specifications
The V680-D2KF67M is designed to be mounted directly to metal. The V680-D2KF67 and V680D2KF67M markings are shown in the following diagrams.
The side with the markings is the communications surface. Mount the RF Tag with this side facing the Antenna.
RFID System
98