Ω min. (at 100 VDC) between the connector terminals and the case
max.)
10 to 150 Hz, 0.20-mm double amplitude, 15-m/s
Z directions
2
150-m/s
−15 to 65°C (with no icing)
acceleration for 3 times each in X, Y, and Z directions (18 times in total)
2
acceleration with 10 sweeps of 8 min each in X, Y, and
V640-HS62
■ Amplifier Unit
V640-HAM11-V2
Item
Host interfaceRS-232C (via dedicated 1:1 protocol or 1:N protocol) or RS-485
Power supply voltage24 VDC (max. fluctuation 20.4 to 26.4 VDC)
Power consumption3 W max.
Insulation resistance20 M
Dielectric strength1,000 VAC (50/60 Hz, 1 minute) between the power supply terminals and the frame ground terminal (leak-
Vibration resistance
Shock resistance
Ambient operating temperature0 to 40°C (with no icing)
Ambient operating humidity35% to 85% (with no condensation)
Ambient storage temperature
Ambient storage humidity35% to 85% (with no condensation)
Degree of protectionIEC60529: IP20
CaseSECC (coated)
GroundGround at a resistance of less than 100
WeightApprox. 500 gApprox. 400 g
Ω min. (at 100 VDC) between the power supply terminals and the frame ground terminal
age current: 5 mA max.)
10 to 150 Hz, 0.20-mm double amplitude, 15-m/s
Z directions
2
150-m/s
−15 to 65°C (with no icing)
acceleration for 3 times each in X, Y, and Z directions (18 times in total)
Ω.
2
acceleration with 10 sweeps of 8 min each in X, Y, and
V640-HAM12
4Electromagnetic Inductive RFID System V640 for Semiconductor Industry
Page 5
■ CIDRW Controller
V700-L22
Item
Host interfaceRS-232C
Power supply voltage24 VDC (max. fluctuation 20.4 to 26.4 VDC)
Power consumption150 mW max.
Insulation resistance50 M
Dielectric strength500 VAC (50/60 Hz, 1 minute) between the power supply terminals and the ground terminal (leakage cur-
Vibration resistance
Shock resistance
Ambient operating temperature0 to 40°C (with no icing)
Ambient operating humidity10% to 85% (with no condensation)
Ambient storage temperature
Ambient storage humidity10% to 95% (with no condensation)
Degree of protectionIEC60529: IP20
GroundGround at a resistance of less than 100
WeightApprox. 580 g
Ω min. (at 500 VDC) between the power supply terminals and the frame ground terminal
rent: 3.5 mA max.)
10 to 150 Hz, 0.20-mm double amplitude, 15-m/s
Z directions
2
150-m/s
−15 to 65°C (with no icing)
acceleration for 3 times each in X, Y, and Z directions (18 times in total)
Ω.
2
acceleration with 10 sweeps of 8 min each in X, Y, and
■ ID Link Unit
V700-L11
Item
Host interfaceRS-232C or RS-485
Power supply voltage24 VDC (max. fluctuation 20.4 to 26.4 VDC)
Power consumption10 W max.
Insulation resistance50 M
Dielectric strength1,000 VAC (50/60 Hz, 1 minute) between the power supply terminals and the frame ground terminal (leak-
Vibration resistance
Shock resistance
Ambient operating temperature0 to 40°C (with no icing)
Ambient operating humidity35% to 85% (with no condensation)
Ambient storage temperature
Ambient storage humidity35% to 85% (with no condensation)
Degree of protectionIEC60529: IP20
GroundGround at a resistance of less than 100
WeightApprox. 200 g
Ω min. (at 500 VDC) between the power supply terminals and the frame ground terminal
age current: 5 mA max.)
10 to 150 Hz, 0.20-mm double amplitude, 15-m/s
Z directions
2
150-m/s
−15 to 50°C (with no icing)
tions may be adversely affected by the surrounding environment.
acceleration for 3 times each in X, Y, and Z directions (18 times in total)
Ω. If grounding is not performed properly, transmission specifica-
2
acceleration with 10 sweeps of 8 min each in X, Y, and
Electromagnetic Inductive RFID SystemV640 for Semiconductor Industry5
Page 6
Applicable SEMI Standards
■ CIDRW System Conforming to SEMI Standards
CIDRW System Conforming to SEMI Standards
Host device
SECS I/II
RS-232C
The Carrier ID Reader Writer (CIDRW) System is an RFID system that conforms to SEMI standards. The V700-L22 CIDRW Controller, the V640HAM1@ Amplifier Unit, the V640-HS6@ CIDRW Head, and a Texas Instruments ID Tag can be used to configure a Carrier ID Reader Writer (CIDRW) System that conforms to the following standards:
• SEMI E99 CARRIER ID READER/WRITER FUNCTIONAL STANDARD
• SEMI E5 EQUIPMENT COMMUNICATIONS STANDARD 2 MESSAGE CONTENT (SECS-II)
• SEMI E4 EQUIPMENT COMMUNICATIONS STANDARD 1 MESSAGE TRANSFER (SEC- I)
Note: SEMI: Semiconductor Equipment and Materials International (Refer to SEMI for standards information. (SEMI URL: http//:www.semi.org/))
SECS: SEMI Equipment Communications Standard
Refer to the User’s Manual (V640-HAM11-V2: Cat. No. Z167; V640-HAM12: Cat. No. Z218) for details.
V700-L22 conforms to SEMI E99-0303 (issued in March 2003).
* The following table lists the ID Tags (manufactured by Texas Instru-
ments) that can be read/written by the V640 RFID System.
Amplifier UnitCIDRW HeadID Tag (Texas
V640-HAM11-V2V640-HS61RI-TRP-DR2B
V640-HAM12V640-HS62
V700-L22 CIDRW Controller
V640-HAM1@ Amplifier Unit
RS-232C
Instruments)
RI-TRP-WR2B
V640-HS6@ CIDRW HeadID Tag*
(Texas Instruments)
6Electromagnetic Inductive RFID System V640 for Semiconductor Industry
Page 7
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Amplifier Unit
(15.8)
(13)
(30.5)
(17.8)
(12)
6.8
6.8
6.8
0.6
V640-HAM11-V2
185
160
43
2
46
56 80
(12)
V640-HAM12
(15.8)
(13)
(32.5)
Four operation
indicator lamps
(30.5)
(17.8)
(12)
4-M4
(1.5)
(4.5)
6.8
6.8
6.8
4.6
55.5
175
Mounting Hole Dimensions
175±0.5
125
100
(11.6)
46 56
Four, 4.5 dia. (mounting holes)
1
46±0.5
(12)
80
(18.2)
DIP switch
43
]
2
(32.5)
Four operation
indicator lamps
(1.5)
(4.5)
33.5
115
(11.6)
(16)
DIP switch
Four, 4.5 dia. (mounting holes)
1
Mounting Hole Dimensions
115±0.5
4-M4
46±0.5
Electromagnetic Inductive RFID SystemV640 for Semiconductor Industry7
Page 8
CIDRW Head
s
V640-HS61
Four, 3.5 dia. (mounting holes)
10122030
Antenna center
9
3.0-dia. coaxial cable,
standard length 2 m
Connector
Mounting Hole Dimensions
4-M3 or 3.5 dia.
Antenna center
V640-HS62
Four, 3.5 dia. (mounting holes)
CIDRW Controller
V700-L22
30 20 12
12
Power lamp
Operation
indicator
lamps
21
29.2
50
12
4
Antenna center
9
10
21
39.2
65
4
150
130
3.011-dia. coaxial cable, length 1.9 m
28 max.
Ferrite core
49
28
Connector
14.5
Mounting Hole Dimensions
4-M3 or 3.5 dia.
20.5 max.
9
21±0.2
9
21±0.2
20±0.2
Antenna center
20±0.2
Mounting Hole Dimension
130±0.2
167
151
3
24
7
151±0.2
4-M4
P6×3
30
Four, 4.5 dia. (mounting holes)
ID Link Unit
V700-L11
16.7
10.7
65
4
110
110
41.5
41.5
26.541.3
18.5
20.3
5
Two, 4.5 dia.
Mounting Hole Dimensions
35.2
2-M4 or 4.2 dia.
100±0.2
604
8Electromagnetic Inductive RFID System V640 for Semiconductor Industry
55±0.2
Page 9
Electromagnetic Inductive RFID SystemV640 for Semiconductor Industry9
Page 10
10Electromagnetic Inductive RFID System V640 for Semiconductor Industry
Page 11
Electromagnetic Inductive RFID SystemV640 for Semiconductor Industry11
Page 12
READ AND UNDERSTAND THIS DOCUMENT
T
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by
OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR
PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS
WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY
CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S ANALYSIS
CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE,
OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND
SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated
products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the
product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by
itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is
it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and
installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS
BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s
test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of
the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request.
Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading
errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner,
for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. Z191-E1-04
In the interest of product improvement, specifications are subject to change without notice.