Switch Mode Power Supply S82K 3
Note: 1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the power supply may not start.
Refer to the Overload Protection section on page 8 for details.
2. Use with DC voltage input is beyond the conditions of approval or conformance to applicable safety standards. (DC input possible with 15 W max.
Use the 7.5-W single-output models under the load of 90% max. if the voltage range is between 90 and 110 VDC.
Do not use the Inverter output for the Power supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of
the Power Supply may result in ignition or burning.
3. Defined with a 100% load and the rated input voltage (100 or 200 VAC.)
4. The output specification is defined at the power supply output terminals.
5. If the V. ADJ adjuster is turned, the voltage will increase by more than +10% of the voltage adjustment range. (+15% for S82K-03012/-03024)
When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
6. Refer to the Overload Protection section on page 8 for details.
7. When using the 90-W model at an ambient temperature of 25×C or less, the overload protection function will operate at currents from 101% to 111% of the
rated output current. When using the 90-W model at an ambient temperature exceeding 25×C, the overload protection function will operate at currents from
92% to 111% of the rated output current.
8. Parallel operation is set with the Parallel/Single Operation Selector Switch.
9. To meet Class-2 requirements with the 100-W, either a fuse or circuit breaker that is UL listed or CSA certified, and rated at 4.2 A max. should be wired in
series with the load to be connected to the Power Supply. Only then can the Power Supply output be considered as meeting Class 2.
Power ratings
(See note 1.)
S82K S82K-P
Single output
Item 50 W 90 W 100 W 90 W 100 W
Efficiency (typical) 80% min. (Varies depending on specifications)
Input Voltage
(See note 2.)
AC 100 to 240 VAC (85 to 264 VAC) 100 V (85 to 132 VAC)/200 V (170 to 264 VAC) Selectable
DC Not possible
Frequency 50/60 Hz (47 to 450 Hz) 50/60 Hz (47 to 63 Hz)
Current
(See note 3.)
100-V input 1.3 A max. 2.5 A max.
200-V input 0.8 A max. 1.5 A max.
Power Factor --- 0.7 min. (at 200 VAC input, at rated output), 100 V: unlimited
Harmonic current emissions --- Conforms to EN6100-3-2 (200-V only)
Leakage current
(See note 3.)
100-V input 0.5 mA max.
200-V input 1 mA max.
Inrush current
(See note 3.)
100-V input 25 A max. (for cold start at 25°C)
200-V input 50 A max. (for cold start at 25°C)
Noise filter Ye s
Output
(See
note
4.)
Voltage Adjustment Range ±10% (with V. ADJ) (−10% to 15% for S82K-05024) (See Note 5.) ±10% (with V. ADJ) (See note 5.)
Ripple (See note 3.) 2% (p-p) max.
Input variation influence 0.5% max. (at 85 to 264 VAC in-
put, 100% load)
0.5% max. (at 85 to 132 VAC input /170 to 264 VAC input, 100% load)
Load variation influence
(rated input voltage)
1.5% max. (0 to 100% load)
Temperature variation influence (See note 3.)
0.05%/°C max.
Start up time 100 ms max. (up to 90% of out-
put voltage at rated input and
output)
200 ms max.
Hold time (See note 3.) 20 ms min.
Additional
functions
Overload protection
(See note 6.)
105% to 160% of rated load
current, gradual current increase, voltage drop intermittent operation, automatic reset
105% to 160% of rated load current, inverted L drop, automatic reset (See note 7.)
Overvoltage protection No
Undervoltage alarm indication
Yes (color: red)
Undervoltage alarm output No Yes
Parallel operation No Yes (up to 2 units.) No Yes (up to 2 units.) (See note 8.)
Oth-erOperating ambient tempera-
ture
Refer to the derating curve in Engineering Data. (with no icing or condensation)
Storage temperature −25 to 65°C (with no icing or condensation)
Operating ambient humidity 25°C to 85% (Storage humidity: 25% to 90%)
Dielectric strength 3.0 kVAC for 1 min. (between all inputs and all outputs)
2.0 kVAC for 1 min. (between all inputs and PE terminals)
1.0 kVAC for 1 min. (between all outputs and PE terminals)
Detection
current
20 mA
Insulation resistance 100 MΩ min. (between all outputs and all inputs, PE terminals) at 500 VDC
Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
Shock resistance
300 m/s2, 3 times each in ±X, ±Y, ±Z directions 150 m/s2, 3 times each in ±X, ±Y, ±Z directions
Output indicator Yes (color: green)
EMI Conducted
Emissions
Conforms to EN61204-3
EN55011 Class B and based
on FCC Class B
Conforms to EN61204-3 EN55011 Class B and based on FCC Class A
Radiated
Emissions
Conforms to EN61204-3 EN55011 Class B
EMS Conforms to EN61204-3 High severity levels
Approved standards UL: UL508 (Listing), 60950-1 Class 2 (excluding Dual output models) (See note 9.)
CSA: cUL: C22.2 No.14, cUR: No. 60950-1 Class 2 (excluding Dual output models) (See
note 9.)
EN/VDE: EN50178 (VDE=0160), EN60950-1 (=VDE0805 Teil 1) Based on VE0106/P100
UL: UL508 (Listing), Class 2 (per UL 1310) 60950-1 (See
note 9.)
CSA: cUL: C22.2 No.14, cUR: No. 60950-1 Class 2 (See note
9.)
EN/VDE: EN50178 (VDE=0160), EN60950-1 (=VDE0805
Teil 1) According to VDE0106/P100"
Weig ht 400 g max. 600 g max. 1000g max.