Omron RX-A2004, RX-A2022, RX-A2007, RX-A2015, RX-A2037 Datasheet

...
Page 1
» Built-in know-how functionality
» Uncompromising Omron quality
» High motor-control performance
Customised to your machine
RX INVERTER
Page 2
Omron realises that you need quality
and reliability, plus the ability to easily and
quickly customise your inverter to the
application in hand. And with the RX, you have
the perfect tool for the job.
Naturally it combines the same high level of
quality and performance for which Omron is
renowned. It also has abundant application
functionality on board and you can customise it
yourself to match your precise requirements.
Key features include:
Up to  kW
Built-in EMC filter
Sensor-less and vector closed-loop control
High starting torque in open loop
(% at . Hz)
Full torque at  Hz in closed loop
Built-in logic programmability
Built-in application functionality
Automatic energy saving
Micro-surge voltage suppression
Built-in Modbus RS
(options for other networks)
Customise your inverter
CX-Drive enables you to make your own programs to suit your machine, e.g. for an unwinding application.
Positioning functionality
Simple positioning is handled by the inverter itself without the need for an external motion controller. Functions include pulse trace position control mode, homing and position teaching.
Focused on application
The inverter is pre-programmed with special application functionality, e.g. brake control, by-pass motor control, orientation stop, interruption filling and switching from speed to positioning control, etc.
High performance
to match your application
Page 3
4
4
T
T
E
E
N
N
AAA
A
N
N
C
C
E
E
Y
E
Sensor-less vector control at 0 Hz domain
With the benefit of patented 0 Hz domain open-loop control mode, the RX can develop 150% torque at 0 Hz allowing zero speed load holding. Moreover, an improved sensor-less vector control algorithm enables the RX to develop more than 200% starting torque at 0.3 Hz.
Cost and space saving filter
The RX has a built-in EMC filter that saves on cost and space compared with the standard external filter solution.
3 ph : EN61800-3 cat. C2
Long life design
RX has been designed with high quality components to guarantee a long operation life and minimise downtime. It includes a versatile maintenance function that warns the user in the event of DC bus capacitor temperature rise or cooling speed reduction.
100%
200%
Torque
(percentage of rating)
600 1200 1800
Rotation speed (min)
120 110 100 90 80
70
60
50
40
30 20 10
0
Frequency (Hz)
Level (dBV)
Conducted emission data
Integrated EMC filter
No filter
500k 1M 2M 5M 10M 20M 30M200150
From high torque to
high motor efficiency...
Reliability with environmental responsibility
Omron is renowned for the reliability of its products. Moreover, Omron’s policy is to offer environmentally safe products free from any banned substances.
Page 4
6 Frequency inverters
RX
Customised to your machine
• Up to 132 kW
• High starting torque in open loop: 200% at 0.3Hz
• Full torque at 0 Hz in closed loop
• Sensor-less and vector closed-loop control
• Built-in EMC filter
• Built-in logic programmability
• Built-in application functionality
• Positioning functionality
• Automatic energy saving
• Micro-surge voltage suppression
• Modbus RS485 (options for other networks)
• CE, cULus, RoHS
Ratings
• 200 V Class three-phase 0.4 to 55 kW
• 400 V Class three-phase 0.4 to 132 kW
System configuration
Choke
LCD 2 lines Remote Operator
Remote Operator Extansion Cable
Output AC Reactor
Braking chopper
Braking Resistor
Option units
ACTIVE POWER
OVERCURRENT
BUSS
BUSS+RR
BC...
CHOPPER
DANGER HIGH VOLTAGE !
RJ45 - USB Cable
CX-Drive CX-One
MCCB
RX
Filter
Input AC Reactor
Motor
Ground
Power Supply
DC Reactor
C 2 2
R 5 2
C 2 4
P E
C 1 6
U 1 1
U
8
R 6
C 2 6
C 2
8
J P
3
U
6
U
7
T
1
U 9
+
+
R 1 5
R 1 5
R 2 5 R 1 5
R 2
0
R
3
0
R 7
R 5
C
5
R
2 1
U 1 4
C 1 7
R 1 4
R 2
8
R
R
11
J
P
1
C 1
U
1
0
C
3
R
5 R
1 R
2
R
3
6
R
3
C
2
1
R
3
5
R 7 0
R
1
2
0
R7
5
R7
8
R
1
1
4
C
2
2
+
+
U 1
+
C
3
5
R
9
9
U
1 2
R
9
5
R
3
9
R 4
0
R 5
7
R
56
D 6
R 6
U 1
5
R 5 4
R
5 5
R
8
T
R
2
1
1
R
1
1
R
1
1
0
R
1
0
7
R
1
1
3
TR1
C
1
3
U 1
3
C 1 0
S
I
­N
C
O
D
E N o
.
U 1 7
7
3
6 0
0
­C
0 2
1 0
J P 5
J P 6
R T 4
R
1
0
R
1
0
R
1
0
5
R 1
0 2
C
1 2
C 1 1
R 9
4
R 9
7
R
9 6
C 20
R 9 5
C
3
9
R
1
3
1
Y 1
U
1
0
C
3
3
Page 5
7
Type designation
200 V class
400V class
Specifications
Three-phase: RX-@ A2004 A2007 A2015 A2022 A2037 A2055 A2075 A2110 A2150 A2185 A2220 A2300 A2370 A2450 A2550
Motor kW
1
1. Based on a standard 3-Phase standard motor.
0.4 0.75 1.5 2.2 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55
Output
characteristics
Inverter
capacity kVA
200 V
1.0 1. 7 2.5 3.6 5.7 8.3 11.0 15.9 22.1 26.3 32.9 41.9 50.2 63.0 76.2
240 V
1.2 2. 0 3.1 4.3 6.8 9.9 13.3 19.1 26.6 31.5 39.4 50.2 60.2 75.6 91.4
Rated output current (A) 3.0 5. 0 7.5 10.5 16.5 24 32 46 64 76 95 121 145 182 220 Max. output voltage Proportional to input voltage: 0..240 V Max. output frequency 400 Hz
Power
supply
Rated input voltage and frequency
3-phase 200..240 V 50/60 Hz
Allowable voltage fluctuation
-15%..+10%
Allowable frequency fluctuation
5%
Braking
Regenerative braking Internal BRD circuit (external discharge resistor)
External regenerative braking unit
Minimum connectable resistance
50 50 35 35 35 16 10 10 7.5 7.5 5
Protective structure
IP20
Cooling method
Forced air cooling
Three-phase: RX-@ A4004 A4007 A4015 A4022 A404 0 A4055 A4075 A4110 A4150 A4185 A4220 A4300 A4370 A4450 A4550 B4750 B490 0 B411K B413K
Motor kW
1
1. Based on a standard 3-Phas e standard motor.
0.4 0.75 1.5 2.2 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132
Output
characteristics
Inverter
capacity kVA
400 V
1.0 1.7 2.5 3.6 6.2 9.7 13.1 17.3 22.1 26.3 33.2 40.1 51.9 63.0 77.6 103.2 121.9 150.3 180.1
480 V
1.2 2.0 3.1 4.3 7.4 11.6 15.8 20.7 26.6 31.5 39.9 48.2 62 .3 75.6 93.1 123.8 146.3 180.4 216.1
Rated output current (A) 1.5 2.5 3.8 5.3 9.0 14 19 25 32 38 48 58 75 91 112 149 176 217 260 Max. output voltage Proportional to input voltage: 0..480 V Max. output frequency 400 Hz
Power
supply
Rated input voltage and frequency
3-phase 380..480 V 50/60 Hz
Allowable voltage fluctuation
-15%..+10%
Allowable frequency fluctuation
5%
Braking
Regenerative braking Internal BRD circuit (external discharge resistor)
External regenerative braking unit
Minimum connectable resistance
100 100 100 100 70 70 35 35 24 24 20
Protective structure
IP20 IP00
Cooling method
Forced air cooling
RX series
A: IP20 B: IP00
RX A4004-EF
Vol tage: 2: Three-phase 200 VAC 4: Three-phase 400 VAC
Max. applicable motor output 004: 0,4kW
~
13K: 132 kW
E: Europe standard
F: Built-in filter
Page 6
8 Frequency inverters
Common specifications
Model number
RX@
Specifications
Control functions
Control methods
Phase-to-phase sinusoidal pulse with modulation PWM (Sensorless vector control, close loop vector with motor feedback, V/F)
Output frequency range
0.10 to 400.00 Hz
Frequency precision
Digital set value: ±0.01% of the max. frequency Analogue set value: ±0.2% of the max. frequency (25 ±10 ºC)
Resolution of frequency set value
Digital set value: 0.01 Hz Analog input: 12 bit
Resolution of output frequency
0.01Hz
Starting torque
150%/0.3 Hz (under sensor-less vector control or sensor-less vector control at 0 Hz) 200%/Torque at 0 Hz (under sensor-less vector control at 0Hz, when a motor size one rank lower than specified is connected)
Overload capability
150%/60 s, 200%/3 s
Frequency set value
0 to 10V DC (10KΩ), -10 to 10V DC (10KΩ), 4 to 20mA (100Ω), RS485 Modbus, Network options
V/f Characteristics
V/f optionally changeable at base frequencies of 30 to 400 Hz, V/f braking constant torque, reduction torque, sensor-less vec­tor control, sensor-less vector control at 0 Hz
Functionality
Inputs signals
8 terminals, NO/NC switchable, sink/source logic switchable [Terminal function] 8 functions can be selected from among 61. Reverse (RV), Multi-step speed setting binary 1 (CF1), Multi-step speed setting binary 2 (CF2), Multi-step speed setting bi­nary 3 (CF3), Multi-step speed setting binary 4 (CF4), Jogging (JG), DC injection braking (DB), 2nd control (SET), 2-step acceleration/deceleration (2CH), Free-run stop (FRS), External trip (EXT), USP function (USP), Commercial switching (CS), Soft lock (SFT), Analog input switching (AT), 3rd control (SET3), Reset (RS), 3-wire start (STA), 3-wire stop (STP), 3-wire forward/reverse (F/R), PID enabled/disabled (PID), PID integral reset (PIDC), Control gain switching (CAS), UP/DWN function accelerated (UP), UP/DWN function decelerated (DWN), UP/DWN function data clear (UDC), Forced op­erator (OPE), Multi-step speed setting bit 1 (SF1), Multi-step speed setting bit 2 (SF2), Multi-step speed setting bit 3 (SF3), Multi-step speed setting bit 4 (SF4), Multi-step speed setting bit 5 (SF5), Multi-step speed setting bit 6 (SF6), Multi-step speed setting bit 7 (SF7), Overload limit switching (OLR), Torque limit enabled (TL), Torque limit switching 1 (TRQ1), Torque limit switching 2 (TRQ2), P/PI switching (PPI), Brake confirmation (BOK), Orientation (ORT), LAD cancel (LAC), Position deviation clear (PCLR), Pulse train position command input permission (STAT), Frequency addition function (ADD), Forced terminal block (F-TM), Torque reference input permission (ATR), Integrated power clear (KHC), Servo ON (SON), Preliminary excitation (FOC), Analog command on hold (AHD), Position command selection 1 (CP1), Position command selection 2 (CP2), Position command se­lection 3 (CP3), Zero return limit signal (ORL), Zero return startup signal (ORG), Forward driving stop (FOT), Reverse driving stop (ROT), Speed/Position switching (SPD), Pulse counter (PCNT), Pulse counter clear (PCC), No allocation (no)
Output signals
5 open collector output terminals: NO/NC switchable, sink/source logic switchable 1 relay (SPDT contact) output terminal: NO/NC switchable [Terminal function] 6 functions can be selected from among 45. Signal during RUN (RUN), Constant speed arrival signal (FA1), Over set frequency arrival signal (FA2), Overload warning (OL), Excessive PID deviation (OD), Alarm signal (AL), Set-frequency-only arrival signal (FA3), Overtorque (OTQ), Signal during momentary power interruption (IP), Signal during undervoltage (UV), Torque limit (TRQ), RUN time exceeded (RNT), Power ON time exceeded (ONT), Thermal warning (THM), Brake release (BRK), Brake error (BER), 0-Hz signal (ZS), Ex­cessive speed deviation (DSE), Position ready (POK), Set frequency exceeded 2 (FA4), Set frequency only 2 (FA5), Overload warning 2 (OL2), Analog FV disconnection detection (FVDc), Analog FI disconnection detection (FIDc), Analog FE discon­nection detection (FEDc), PID FB status output (FBV), Network error (NDc), Logic operation output 1 (LOG1), Logic operation output 2 (LOG2), Logic operation output 3 (LOG3), Logic operation output 4 (LOG4), Logic operation output 5 (LOG5), Logic operation output 6 (LOG6), Capacitor life warning (WAC), Cooling fan life warning (WAF), Starting contact signal (FR), Fin overheat warning (OHF), Light load detection signal (LOC), Operation ready (IRDY), Forward run (FWR), Reverse run (RVR), Fatal fault (MJA), Window comparator FV (WCFV), Window comparator FI (WCFI), Window comparator FE (WCFE), Alarm codes 0 to 3 (AC0 to AC3)
Standard functions
V/f free setting (7), Upper/lower frequency limit, Frequency jump, Curve acceleration/deceleration, Manual torque boost level/ break, Energy-saving operation, Analog meter adjustment, Starting frequency, Carrier frequency adjustment, Electronic ther­mal function, (free setting available), External start/end (frequency/rate), Analog input selection, Trip retry, Restart during mo­mentary power interruption, Various signal outputs, Reduced voltage startup, Overload limit, Initialization value setting, Automatic deceleration at power-off, AVR function, Automatic acceleration/deceleration, Auto tuning (Online/Offline), High torque multi-motor operation control (sensor-less vector control of two monitors with one Inverter)
Analogue inputs
Analogue inputs 0 to 10V and -10 to 10 V (10KΩ), 4 to 20mA (100Ω)
Analogue outputs
Analog voltage output, Analog current output, Pulse train output
Accel/Decel times
0.01 to 3600.0s (line/curve selection)
Display
Status indicator LED’s Run, Program, Power, Alarm, Hz, Amps , Volts, % Digital operator: Available to monitor 23 items, output current, output frequency...
Protection functions
Motor overload protection
Electronic Thermal overload relay and PTC thermistor input
Instantaneous overcurrent
200% of rated current for 3 seconds
Overload
150% for 1 minute
Overvoltage
800V for 400V type and 400V for 200V type
Momentary power loss
Decelerates to stop with DC bus controlled, coast to stop
Cooling fin overheat
Temperature monitor and error detection
Stall prevention level
Stall prevention during acceleration, deceleration and constant speed
Ground fault
Detection at power on
Power charge indication
On when voltage between P and N is higher than 45V
Ambient conditions
Degree of protection
IP20 / IP00
Ambient humidity
90% RH or less (without condensation)
Storage temperature
-20 ºC..+65 ºC (short-term temperature during transportation)
Ambient temperature
10°C to 50°C
Installation
Indoor (no corrosive gas, dust, etc.)
Installation height
Max. 1000 m
Vibration
RX-A004 to A220, 5.9 m/s
2
(0.6G), 10 to 55 Hz
RX-A300 to B13K, 2.94 m/s
2
(0.3G), 10 to 55 Hz
Page 7
9
Dimensions
W
2-φ6
W1
W2
6
D
D1
H1
H
Figure 1
W1
7
W2
D2
D1
H1
H
2-φ7
W
D
Figure 3
W
10
H1
H
2-φ10
D
W1
Figure 4
W2
D1
D2
2-φ7
W1
7
H1
H
W
D
Figure 2
Page 8
10 Frequency inverters
Voltage class Inverter model RX@ Figure
Dimensions in mm
W W1 W2 H H1 D D1 D2 Weight (KG)
Three-phase
200 V
A2004
1 150 130 143 255 241 140 62 - 3.5
A2007
A2015
A2022
A2037
A2055
2 210 189 203 260 246 170 82 13.6 6A2075
A2110
A2150
3 250 229 244 390 376 190 83 9.5 14A2185
A2220
A2300
4
310 265 - 540 510 195 - - 20
A2370
390 300 - 550 520 250 - - 30
A2450
A2550 480 380 - 700 670 250 - - 43
Three-phase
400 V
A4004
1 150 130 143 255 241 140 62 - 3.5
A4007
A4015
A4022
A4040
A4055
2 210 189 203 260 246 170 82 13.6 6A4075
A4110
A4150
3 250 229 244 390 376 190 83 9.5 14A4185
A4220
A4300
4
310 265 - 540 510 195 - - 22
A4370
390 300 - 550 520 250 - - 30A4450
A4550
B4750
5
390 300 - 700 670 268 - - 60
B4900
B411K
480 380 - 740 710 270 - - 80
B413K
2-φ12
2-12
300
390
268
700
79
670
357
Figure 5
Page 9
11
Rasmi Filters
Voltage Inverter model Rasmi model
Dimensions
Weight
KG
L W H X Y M Filter type
3x200 V
RX-A2004
AX-FIR2018-RE 305 125 45 290 110 M5
Footprint
2.0
RX-A2007
RX-A2015
RX-A2022
RX-A2037
RX-A2055
AX-FIR2053-RE 312 212 56 296 189 M6 2.5RX-A2075
RX-A2110
RX-A2150
AX-FIR2110-RE
455 110 240 414 80 Book type
8.0RX-A2185
RX-A2220
RX-A2300 AX-FIR2145-RE 8.6
RX-A2370
AX-FIR3250-RE
386 260 135 240 235 - Block type
13
RX-A2450
RX-A2550 AX-FIR3320-RE 13.2
3x400 V
RX-A4004
AX-FIR3010-RE 305 125 45 290 110 M5
Footprint
1.9
RX-A4007
RX-A4015
RX-A4022
RX-A4040
RX-A4055
AX-FIR3030-RE 312 212 50 296 189 M6 2.2RX-A4075
RX-A4110
RX-A4150
AX-FIR3053-RE 451 252 60 435 229 M6 4.5RX-A4185
RX-A4220
RX-A4300 AX-FIR3064-RE 598 310 70 578 265 M8 7.0
RX-A4370 AX-FIR3100-RE
455 110 240 414 80 - Book type
8.0
RX-A4450
AX-FIR3130-RE 8.6
RX-A4550
RX-B4750
AX-FIR3250-RE
386 260 135 240 235 - Blcok type
13.0
RX-B4900
RX-B411K
AX-FIR3320-RE 13.2
RX-B413K
drive mounts
W
H
Y
XL
output flexes
WH
Y
XL
Footprint Dimensions Book Type Dimensions
Y
W
H
LX
Block Type Dimensions
Page 10
12 Frequency inverters
Input AC Reactor
DC Reactor
Voltage Reference
Dimensions Weight
Kg
A B1
B2 C1 C2 D E F
200V
AX-RAI02800100-DE
120
-
80
-
120 80 62 5.5 2.35
AX-RAI00880200-DE AX-RAI00350335-DE
180
85
190
140
55
6
5.5
AX-RAI00180670-DE AX-RAI00091000-DE 205 6.5 AX-RAI00071550-DE 105 205 85 11.7 AX-RAI00042300-DE 240 130 - 210 - 200 75 16.0
400V
AX-RAI07700050-DE
120
-
70
120 80
52
5.5
1.78
AX-RAI03500100-DE
80 62
2.35 AX-RAI01300170-DE 2.5 AX-RAI00740335-DE
180
85
190
140
55
6
5.5
AX-RAI00360500-DE
205
6.5 AX-RAI00290780-DE 105 85 11.7 AX-RAI00191150-DE 240 110 275 200 75 16.0
200V 400V
Reference
AX-RC
Fig Dimensions KgReference
AX-RC
Fig Dimensions
Kg
A
B C D E F G H
A
B C D E F G H
21400016-DE
1
84 113
96
101 66 5 7.5 2
1.22
43000020-DE
1
84 113
96
101 66 5 7.5 2
1.22
10700032-DE 27000030-DE
105 1.60
06750061-DE
105 1.60
14000047-DE
03510093-DE 10100069-DE
116 1.95
02510138-DE
116 1.95
06400116-DE
108 135 133 120 82 6.5
9.5
9.5 3.70
01600223-DE
108 135 124 120 82 6.5
9.5
9.5 3.20
04410167-DE
120 152
136
135 94 7
-
5.20
01110309-DE
120 152
136
135 94
7-
5.20
03350219-DE
146 6.00
00840437-DE
146 6.00
02330307-DE
150 177
160
160 115 7 2
11.4
00590614-DE
150 177
160
160 115 2
11.4
01750430-DE
182.6 14.3
00440859-DE
182.6 14.3
01200644-DE
2
195
161
162.5 185
88
10
--
17.0
00301275-DE
2
195
161
162.5 185
88
10
--
17.0
00920797-DE 196 123 25.5
00231662-DE
196 123 25.5
00741042-DE
240
188
200 228
109
12
34.0
00192015-DE
240
188
200 228
109
12
34.0
00611236-DE 198 119 38.0
00162500-DE
198 119 38.0
00501529-DE 228 149 42.0
00133057-DE
228 149 42.0
Figure 1
C
D
A
F
E
B
Figure 2
Page 11
13
Output AC Reactor
Chokes
Braking Unit Dimensions
Reference
Dimensions Weight
Kg
A
B2 C2 D E F AX-RAO11500026-DE 120 70 120 80 52 5.5 1.78 AX-RAO07600042-DE 120 70 120 80 52 5.5 1.78 AX-RAO04100075-DE 120 80 120 80 62 5.5 2.35 AX-RAO03000105-DE 120 80 120 80 62 5.5 2.35 AX-RAO01830180-DE 180 85 190 140 55 6 5.5 AX-RAO01150220-DE 180 85 190 140 55 6 5.5 AX-RAO00950320-DE 180 85 205 140 55 6 6.5 AX-RAO00630430-DE 180 95 205 140 65 6 9.1 AX-RAO00490640-DE 180 95 205 140 65 6 9.1 AX-RAO16300038-DE 120 70 120 80 52 5.5 1.78 AX-RAO11800053-DE 120 80 120 80 52 5.5 2.35 AX-RAO07300080-DE 120 80 120 80 62 5.5 2.35 AX-RAO04600110-DE 180 85 190 140 55 6 5.5 AX-RAO03600160-DE 180 85 205 140 55 6 6.5 AX-RAO02500220-DE 180 95 205 140 55 6 9.1 AX-RAO02000320-DE 180 105 205 140 85 6 11.7
Reference D
diameter
Motor
KW
Dimensions Weight
Kg
L W H X Y m AX-FER2102-RE 21 < 2.2 85 22 46 70 - 5 0.1 AX-FER2515-RE 25 < 15 105 25 62 90 - 5 0.2 AX-FER5045-RE 50 < 45 150 50 110 125 30 5 0.7 AX-FER6055-RE 60 > 45 200 65 170 180 45 6 1.7
Reference
Dimensions
B B1 H H1 T S
AX-BCR4015045-TE
82.5 40.5 150 138 220 6
AX-BCR4017068-TE AX-BCR2035090-TE
130 64.5 205 193 208 6
AX-BCR2070130-TE AX-BCR4035090-TE AX-BCR4070130-TE AX-BCR4090240-TE 131 64.5 298 280 300 9
X
H
YW
Ø m
L
Ø d
S
B
H1
T1B
H
ACTIVE POWER
OVERCURRENT
BUSS
BUSS+
R
R
BC...
CHOPPER
DANGER HIGH VOLTAGE !
Page 12
14 Frequency inverters
Resistor Dimensions
Type Fig.
Dimensions
Weight
L H M I T KG
AX-REM00K2070-IE
1
105 27 36 94 - 0.2AX-REM00K2120-IE
AX-REM00K2200-IE
AX-REM00K4075-IE
200 27 36 189 - 0.425AX-REM00K4035-IE
AX-REM00K4030-IE
AX-REM00K5120-IE 260 27 36 249 - 0.58
AX-REM00K6100-IE
320 27 36 309 - 0.73
AX-REM00K6035-IE
AX-REM00K9070-IE
2 200 62 100 74 - 1.41AX-REM00K9020-IE
AX-REM00K9017-IE
AX-REM01K9070-IE
3 365 73 105 350 70 4
AX-REM01K9017-IE
AX-REM02K1070-IE
4
310 100 240 295 210 7
AX-REM02K1017-IE
AX-REM03K5035-IE
365 100 240 350 210 8
AX-REM03K5010-IE
AX-REM19K0006-IE
5
140 350 180 100 160 6
AX-REM19K0008-IE
AX-REM19K0020-IE
AX-REM19K0030-IE
AX-REM38K0012-IE 240 350 180 200 160 11
AX-REM00K1xxx
Fig 1
Fig 2
Fig 3
Fig 4
Fig 5
Page 13
15
Standard connections
Terminal Block Specifications
Terminal Name Function (signal level)
R/L1, S/L2, T/L3
Main circuit power supply input Used to connect line power to the drive.
U/T1, V/T2, W/T3
Inverter output Used to connect the motor
PD/+1, P/+
External DC reactor terminal Normally connected by the short-circuit bar. Remove the short-circuit bar between +1 and P/
+2 when a DC reactor is connected.
P/+, RB
Braking resistor connection terminals
Connect option braking resistor (if a braking torque is required)
P/+, N/-
Regenerative braking unit connection terminal
Connect optional regenerative braking units.
Grounding For grounding (grounding should conform to the local grounding code.)
DC reactor (optional)
3-phase 200 V AC 3-phase 400 V AC
Multi-function input 1
Multi-function input 2
Multi-function input 3
Multi-function input 4
Multi-function input 5
Multi-function input 6
Multi-function input 7
Multi-function input 8
Frequency reference power supply
Frequency setting unit 500 to 2 kΩ
Frequency reference input (voltage)
Frequency reference auxiliary input (voltage)
Frequency reference input (current)
Frequency reference common
Sequence input common
M
R/L1
PD/+1 P/+
Braking resistor (optional)
RBN/-
T/L3
R
T
Ro
To
S/L2
U/T1
W/T3
12 Multi-function output 2
13 Multi-function output 3
14 Multi-function output 4
15 Multi-function output 5
CM2
SP
SN
RP
SN
AM
AMI
FM
Option 1
Option 1
Multi-function output common
11 Multi-function output 1
Relay output *1
Common
V/T2
1
FW
P24
CM1
4
PLC
Thermistor
TH
H
OI
L
O
O2
3
2
5
RS485 communication
6
7
8
Short-circuit
wire
To wire the control circuit power
supply and main circuit power supply separately, be sure to
remove the J51 connector wire first.
Control circuit power supply
J51
For termination resistors
Analog monitor output (voltage output)
Analog monitor output (current output)
Digital monitor output (PWM output)
AL1
AL2
AL0
Page 14
16 Frequency inverters
Control Circuit
Type No.
Signal name Function Signal level
Frequency reference input
H
Frequency reference power supply 10 V DC 20mA max
O
Voltage frequency reference input 0 to 12V DC (10 KΩ)
O2
Voltage auxiliary frequency reference 0 to +/- 12V DC (10 KΩ)
OI
Current frequency reference input 4 to 20mA (100 Ω)
L
Frequency reference common -
Monitor
Output
AM
Multi-function analog voltage output Factory setting: Output frequency 2mA max
AMI
Multi-function analog current output Factory setting: Output frequency
4 to 20mA (max imp 250Ω)
FM
PWM monitor output Factory setting: Output frequency
0 to 10V DC Max 3.6 kHz
Power
Supply
P24
Internal 24V DC Power supply for contact input signal 100mA max
CM1
Input common Common terminal for P24, TH and analog monitor (AM, AMI, MP) terminals
Function
Selection
FW
Forward rotation command terminal Motor runs in forwards direction when FW is ON
27V DC max Input imped 4.7KΩ Max current 5.6mA On: 18V DC or more
1
Multi-function input
Factory setting: Reverse (RV)
2
Factory setting: External trip (EXT)
3
Factory setting: Reset (RS)
4
Factory setting: Multi-step speed reference 1 (CF1)
5
Factory setting: Multi-step speed reference 2 (CF2)
6
Factory setting: Jogging (JG)
7
Factory setting: Second control (SET)
8
Factory setting: No allocation (NO)
PLC
Multi-function input common
Sink logic: Short-circuiting P24 and CM1 Source logic: Short-circuiting PSC and CM1 With external supply remove short-circuit bar
Status/ Factor
11
Multi-function output
Factory setting: During Run (RUN)
27V DC max 50 mA max
12
Factory setting: 0 Hz signal (ZS)
13
Factory setting: Overload warning (OL)
14
Factory setting: Overtorque (OTQ)
15
Factory setting: Constant speed arrival (FA1)
CM2
Multi-function output common Common terminal for multi-function output terminals P1 to P5
Relay
output
AL1
Relay output (Normally close)
Factory setting: Alarm output (AL)
Under normal operation
MA-MC open
MB-MC close
R load
AL1-AL0
250VAC 2A
AL2-AL0
250VAC 1A
I load
250V AC 0.2A
AL2
Relay output (Normally open)
AL0
Relay output common
Sensor TH
External thermistor input terminal
SC terminal functions as the common terminal
100mW minimum
Impedance at temperature error: 3KΩ
0 to 8V DC
Comms
SP
RS485 Modbus terminals - Differential input
SN
RP
RS485 terminating resistor terminals --
SN
Page 15
17
Inverter heat loss Three-phase 200 V class
Three-phase 400 V class
Input AC Reactor
Model RX- A2004 A2007 A2015 A2022 A2037 A2055 A2075 A2110 A2150 A2185 A2220 A2300 A2370 A2450 A2550
Inverter
capacity
kVA
200 V
1.0 1.7 2.5 3.6 5.7 8.3 11.0 15.9 22.1 26.3 32.9 41.9 50.2 63.0 76.2
240 V
1.2 2.0 3.1 4.3 6.8 9.9 13.3 19.1 26.6 31.5 39.4 50.2 60.2 75.6 91.4
Rated current (A)
3.0 5.0 7.5 10.5 16.5 24 32 46 64 76 95 121 145 182 220
Heat
loss W
Losses at 70% load
64 76 102 127 179 242 312 435 575 698 820 1100 1345 1625 1975
Losses at 100% load
70 88 125 160 235 325 425 600 800 975 1150 1550 1900 2300 2800
Efficiency at rated output
85.1 89.5 92.3 93.2 94.0 64.4 94.6 94.8 94.9 95.0 95.0 95.0 95.1 95.1 95.1
Cooling Method
Forced-air-cooling
Model RX- A4004 A4007 A4015 A4022 A4040 A4055 A4075 A4110 A4150 A4185 A4220 A4300 A4370 A4450 A4550 B4750 B4900 B411K B413K
Inverter
capacity
kVA
400V
1.0 1.7 2.5 3.6 6.2 9.7 13.1 17.3 22.1 26.3 33.2 40.1 51.9 63.0 77.6 103.2 121.9 150.3 180.1
480V
1.2 2.0 3.1 4.3 7.4 11.6 15.8 20.7 26.6 31.5 39.9 48.2 62.3 75.6 93.1 123.8 146.3 180.4 216.1
Rated current (A)
1.5 2.5 3.8 5.3 9.0 14 19 25 32 38 48 58 75 91 112 149 176 217 260
Heat
lloss W
Losses at
70% load
64 76 102 127 179 242 312 435 575 698 820 1100 1345 1625 1975
2675 3375 3900 4670
Losses at
100% load
70 88 125 160 235 325 425 600 800 975 1150 1550 1900 2300 2800
3800 4800 5550 6650
Efficiency at rated
output
85.1 89.5 92.3 93.2 94.0 64.4 94.6 94.8 94.9 95.0 95.0 95.0 95.1 95.1 95.1
95.2 95.2 95.2 95.2
Cooling Method Forced-air-cooling
3 phase 200 V class 400 V class
Max. applicable
motor output kW
Reference
Current value AInductancemHMax. applicable
motor output kW
Reference
Current value AInductance
mH
0.4 to 1.5 AX-RAI02800100-DE 10.0 2.8 0.4 to 1.5 AX-RAI07700050-DE
5.0 7.7
2.2 to 3.7 AX-RAI00880200-DE 20.0 0.88 2.2 to 3.7 AX-RAI03500100-DE 10.0 3.5
5.5 to 7.5 AX-RAI00350335-DE 33.5 0.35 5.5 to 7.5 AX-RAI01300170-DE
17.0 1.3
11.0 to 15.0 AX-RAI00180670-DE 67.0 0.18 11.0 to 15.0 AX-RAI00740335-DE
33.5 0.74
18.5 to 22.0 AX-RAI00091000-DE 100.0 0.09 18.5 to 22.0 AX-RAI00360500-DE
50.0 0.36
30.0 to 37.0 AX-RAI00071550-DE 155.0 0.07 30.0 to 37.0 AX-RAI00290780-DE
78.0 0.29
45.0 to 55.0 AX-RAI00042300-DE 230.0 0.04 45.0 to 55.0 AX-RAI00191150-DE
115.0 0.19
MCCB
Power supply
AC reactor
RX
R/L1U
V
W
X
YZS/L2
T/L3
Page 16
18 Frequency inverters
DC Reactor
Output AC
Reactor
Braking Unit
200 V class 400 V class
Max. applicable
motor output kW
Reference
Current value AInductancemHMax. applicable
motor output kW
Reference
Current value AInductance
mH
0.4 AX-RC10700032-DE 3.2 10.70 0.4 AX-RC43000020-DE
2.0 43.00
0.7 AX-RC06750061-DE 6.1 6.75 0.7 AX-RC27000030-DE 3.0 27.00
1.5 AX-RC03510093-DE 9.3 3.51 1.5 AX-RC14000047-DE
4.7 14.00
2.2 AX-RC02510138-DE 13.8 2.51 2.2 AX-RC10100069-DE 6.9 10.10
3.7 AX-RC01600223-DE 22.3 1.60 4.0 AX-RC06400116-DE 11.6 6.40
5.5 AX-RC01110309-DE 30.9 1.11 5.5 AX-RC04410167-DE 16.7 4.41
7.5 AX-RC00840437-DE 43.7 0.84 7.5 AX-RC03350219-DE 21.9 3.35
11.0 AX-RC00590614-DE 61.4 0.59 11.0 AX-RC02330307-DE 30.7 2.33
15.0 AX-RC00440859-DE 85.9 0.44 15.0 AX-RC01750430-DE 43.0 1.75
18.5 to 22 AX-RC00301275-DE 127.5 0.30 18.5 to 22 AX-RC01200644-DE 64.4 1.20 30 AX-RC00231662-DE 166.2 0.23 30 AX-RC00920797-DE 79.7 0.92 37 AX-RC00192015-DE 201.5 0.19 37 AX-RC00741042-DE 104.2 0.74 45 AX-RC00162500-DE 250.0 0.16 45 AX-RC00611236-DE 123.6 0.61 55 AX-RC00133057-DE 305.7 0.13 55 AX-RC00501529-DE 152.9 0.50
200 V class 400 V class
Max. applicable
motor output kW
Reference
Current value AInductancemHMax. applicable
motor output kW
Reference
Current value AInductance
mH
0.4 AX-RAO11500026-DE 2.6 11.50
0.4 to 1.5 AX-RAO16300038-DE
3.8 16.30
0.75 AX-RAO07600042-DE 4.2 7.60
1.5 AX-RAO04100075-DE 7.5 4.10
2.2 AX-RAO03000105-DE 10.5 3.00 2.2 AX-RAO11800053-DE 5.3 11.80
3.7 AX-RAO01830160-DE 16.0 1.83 4.0 AX-RAO07300080-DE
8.0 7.30
5.5 AX-RAO01150220-DE 22.0 1.15 5.5 AX-RAO04600110-DE 11.0 4.60
7.5 AX-RAO00950320-DE 32.0 0.95 7.5 AX-RAO03600160-DE 16.0 3.60 11 AX-RAO00630430-DE 43.0 0.63 11 AX-RAO02500220-DE 22.0 2.50 15 AX-RAO00490640-DE 64.0 0.49 15 AX-RAO02000320-DE 32.0 2.00
Voltage Reference
Specifications
Permanent Peak (5s max) Minimum
connectable
resistor (Ohms)
Current (A) Brake power (KVA) Current (A) Brake power (KVA)
200V
AX-BCR2035090-TE 35 13 90 32 4 AX-BCR2070130-TE 70 25 130 47 2.8
400V
AX-BCR4015045-TE 15 11 45 33 16 AX-BCR4017068-TE 17 13 68 51 11 AX-BCR4035090-TE 35 26 90 67 8.5 AX-BCR4070130-TE 70 52 130 97 5.5 AX-BCR4090240-TE 90 67 240 180 3.2
Powe r supply
RX
DC reactor
R/L1
PD/+1
P/+
MCCB
S/L2
T/L3
Page 17
19
RX
Ordering information
Specifications Model Specifications Model
Voltage class Max motor kW
Rated current A
Standard Voltage class Max motor kW
Rated
current A
Standard
Three-phase
200 V
0.4 3.0 RX-A2004-EF
Three-phase
400 V
0.4 1.5 RX-A4004-EF
0.75 5.0 RX-A2007-EF 0.75 2.5 RX-A4007-EF
1.5 7.5 RX-A2015-EF 1.5 3.8 RX-A4015-EF
2.2 10.5 RX-A2022-EF 2.2 5.3 RX-A4022-EF
4.0 16.5 RX-A2037-EF 4.0 9.0 RX-A4040-EF
5.5 24 RX-A2055-EF 5.5 14 RX-A4055-EF
7.5 32 RX-A2075-EF 7.5 19 RX-A4075-EF
11 46 RX-A2110-EF 11 25 RX-A4110-EF
15 64 RX-A2150-EF 15 32 RX-A4150-EF
18.5 76 RX-A2185-EF 18.5 38 RX-A4185-EF
22 95 RX-A2220-EF 22 48 RX-A4220-EF
30 121 RX-A2300-EF 30 58 RX-A4300-EF
37 145 RX-A2370-EF 37 75 RX-A4370-EF
45 182 RX-A2450-EF 45 91 RX-A4450-EF
55 220 RX-A2550-EF 55 112 RX-A4550-EF
- - - 75 149 RX-B4750-EF
- - - 90 176 RX-B4900-EF
- - - 110 217 RX-B411K-EF
- - - 132 260 RX-B413K-EF
Choke
A
B
B
LCD 2 lines Remote Operator
Remote Operator Extansion Cable
A
A
D
A
Output AC Reactor
Braking chopper
RJ45 - USB Cable
C2 2
R 5
2
C 2 4
P E
C 16
U 1 1
U
8
R 6
C 2 6
C 2
8
J P
3
U
6
U
7
T
1
U 9
+
+
R15
R1
5
R25
R 1 5
R
2 0
R
3
0
R 7
R 5
C5
R 21
U1 4
C 1 7
R 1 4
R
2
8
R
R
1 1
J
P
1
C1
U
10
C
3
R
5 R
1 R
2
R
3
6
R
3
C
2
1
R
3
5
R
7 0
R 1 2
0
R
7
5
R
7
8
R 1
1
4
C
2
2
+
+
U 1
+
C
3
5
R9 9
U
1 2
R
9
5
R
3
9
R 4 0
R 5
7
R
5 6
D
6
R 6
U 1 5
R 5 4
R
5 5
R
8
T
R
2
1
1
R
1
1
R
1
1
0
R
1
0
7
R
1
1
3
T
R
1
C 1
3
U1
3
C
1 0
S
I
­N
CO
D
E
No
.
U
17
7
3
6 0 0
-C 0 21
0
J P 5
JP 6
R T4
R
1
0 R1
0
R
1
05
R
1 0 2
C 1 2
C
1 1
R9 4
R 9 7
R 96
C 2 0
R9 5
C
3
9
R
1
3
1
Y
1
U10
C
3
3
Option units
Braking Resistor
D
C
ACTIVE POWER
OVERCURRENT
BUSS
BUSS+
R
R
BC...
CHOPPER
DANGER HIGH VOLTAGE !
B
E
A
CX-Drive CX-One
MCCB
RX
Filter
Input AC Reactor
Motor
Ground
Power Supply
DC Reactor
Page 18
20 Frequency inverters
A Line filters
A Input AC Reactors
A DC Reactors
A Chokes
A Output AC Reactor
Rasmi Line filter
200V 400V
Model RX-@ Reference
Rated
current (A)
Leakage
Nom / Max
Kg Model RX-@ Reference
Rated
current (A)
Leakage
Nom / Max
Kg
A2004 / A2007/ A2015/
A2022 / A2037
AX-FIR2018-RE 18 0.7/40 mA 2.0
A4004/ A4007/ A4015/
A4022/ A4040
AX-FIR3010-RE 10 0.3/40 mA 1.9
A2055 / A2075 / A2110 AX-FIR2053-RE 53 0.7/40 mA 2.5 A4055 / A4075 / A4110 AX-FIR3030-RE 30 0.3/40 mA 2.2
A2150/ A2185/ A2220 AX-FIR2110-RE 110 1.2/70 mA 8.0 A4150/ A4185/ A4220 AX-FIR3053-RE 53 0.8/70 mA 4.5
A2300 AX-FIR2145-RE 145 1.2/70 mA 8.6 A4300 AX-FIR3064-RE 64 3/160 mA 7.0
A2370/ A2450 AX-FIR3250-RE 250 6/300 mA 13.0 A4370 AX-FIR3100-RE 100 2/130 mA 8.0
A2550 AX-FIR3320-RE 320 6/300 mA 13.2 A4450 / A4550 AX-FIR3130-RE 130 2/130 mA 8.6
-
A4750 / A4900 AX-FIR3250-RE 250 10/500 mA 13.0
A411K / A413K AX-FIR3320-RE 320 10/500 mA 13.2
Voltage
3-Phase 200 VAC 3-Phase 400 VAC
Inverter Model RX-@
AC Reactor Reference
Inverter Model RX-@
AC Reactor Reference
A2004 / A2007 / A2015 AX-RAI02800100-DE A4004 / A4007 / A4015 AX-RAI07700050-DE
A2022 / A2037 AX-RAI00880200-DE A4022 / A4040 AX-RAI03500100-DE
A2055 / A2075 AX-RAI00350335-DE A4055 / A4075 AX-RAI01300170-DE
A2110 / A2150 AX-RAI00180670-DE A4110 / A4150 AX-RAI00740335-DE
A2185 / A2220 AX-RAI00091000-DE A4185 / A4220 AX-RAI00360500-DE
A2300 / A2370 AX-RAI00071550-DE A4300 / A4370 AX-RAI00290780-DE
A2450 / A2550 AX-RAI00042300-DE A4450 / A4550 AX-RAI00191150-DE
Voltage
3-Phase 200 VAC 3-Phase 400 VAC
Inverter Model RX-@ AC Reactor Reference Inverter Model RX-@ AC Reactor Reference
A2004 AX-RC10700032-DE A4004 AX-RC43000020-DE
A2007 AX-RC06750061-DE A4007 AX-RC27000030-DE
A2015 AX-RC03510093-DE A4015 AX-RC14000047-DE
A2022 AX-RC02510138-DE A4022 AX-RC10100069-DE
A2037 AX-RC01600223-DE A4040 AX-RC06400116-DE
A2055 AX-RC01110309-DE A4055 AX-RC04410167-DE
A2075 AX-RC00840437-DE A4075 AX-RC03350219-DE
A2110 AX-RC00590614-DE A4110 AX-RC02330307-DE
A2150 AX-RC00440859-DE A4150 AX-RC01750430-DE
A2185 / A2220 AX-RC00301275-DE A4185 / A4220 AX-RC01200644-DE
A2300 AX-RC00231662-DE A4300 AX-RC00920797-DE
A2370 AX-RC00192015-DE A4370 AX-RC00741042-DE
A2450 AX-RC00162500-DE A4450 AX-RC00611236-DE
A2550 AX-RC00133057-DE A4550 AX-RC00501529-DE
Model Diameter Description
AX-FER2102-RE 21 For 2.2 KW motors or below
AX-FER2515-RE 25 For 15 KW motors or below
AX-FER5045-RE 50 For 45 KW motors or below
AX-FER6055-RE 60 For 55 KW motors or above
Voltage
200V 400V
Model RX-@ Reference Model RX-@ Reference
A2004 AX-RAO11500026-DE
A4004 / A4007 / A4015 AX-RAO16300038-DEA2007 AX-RAO07600042-DE
A2015 AX-RAO04100075-DE
A2022 AX-RAO03000105-DE A4022 AX-RAO11800053-DE
A2037 AX-RAO01830160-DE A4040 AX-RAO07300080-DE
A2055 AX-RAO01150220-DE A4055 AX-RAO04600110-DE
A2075 AX-RAO00950320-DE A4075 AX-RAO03600160-DE
A2110 AX-RAO00630430-DE A4110 AX-RAO02500220-DE
A2150 AX-RAO00490640-DE A4150 AX-RAO02000320-DE
Page 19
21
B Accessories
C Option boards
D Braking unit, braking resistor unit
Types Model Description Functions
Digital
operator
3G3AX-OP05 LCD remote operator 2 Line LCD remote operator with copy function, cable length max. 3m.
3G3AX-CAJOP300-EE Remote operator cable 3 meters cable for connecting remote operator
Accessories
3G3AX-PCACN2 USB converter / USB cable RJ45 to USB connection cable
Types Model Description Functions
Encoder
Feedback
3G3AX-PG PG speed controller option card
Phase A,B and Z pulse (differential pulse) inputs (RS-422)
Pulse train position command input (RS-422)
Pulse monitor output (RS-422)
PG frequency range: 100 kHz max
Communication
option board
SJ-DN DeviceNet option card Used for running or stopping the inverter or give frequency reference through DeviceNet
SJ-PB Profibus option card Used for running or stopping the inverter or give frequency reference through Profibus
Digital
input
SJ-DG Digital input option card Allows to set frequency reference from a digital selection
Inverter Braking resistor unit
Voltage
Max.
motor
kW
Inverter
RX@
Braking Unit
AX-BCR@
Connectable
min.
resistance Ω
Inverter mounted type (3 %ED,
10 sec max)
Braking
torque %
External resistor 10%ED
10 sec max for built-in
5 sec max for Braking Unit
Braking
torque %
3-phase Type AX- Resist Ω Type AX- Resist Ω
200 V
(single-/
three-
phase)
0.55 2004
Built-in
50 REM00K1200-IE 200
180 REM00K1200-IE 200 180
1.1 2007 100 REM00K2070-IE 70 200
1.5 2015
35
REM00K2070-IE 70
140 REM00K4075-IE 75 130
2.2 2022 90 REM00K4035-IE 35 180
4.0 2037 REM00K4075-IE 75 50 REM00K6035-IE 35 100
5.5 2055 16 REM00K4035-IE 35
75 REM00K9020-IE 20 150
7.5 2075
10
55 REM01K9017-IE 17 110
11.0 2110 REM00K6035-IE 35 40 REM02K1017-IE 17 75
15.0 2150
7.5
REM00K9017-IE 17 55 REM03K5010-IE 10 95
18.5 2185 REM03K5010-IE 10
75
REM19K0008-IE 8
95
22.0 2220 5 65 80
30.0 2300
2035090-TE 4 REM19K0006-IE
680
37.0 2370 660
45.0 2450
2070130-TE 2.8 2 x REM19K0006-IE
3105
55.0 2550 385
400 V
(three-
phase)
0.55 4004
Built-in
100
REM00K1400-IE 400
200
REM00K1400-IE 400
200
1.1 4007 200 200
1.5 4015 REM00K1200-IE 200 190 REM00K2200-IE 200 190
2.2 4022 REM00K2200-IE 200 130 REM00K5120-IE 120 200
4.0 4040 70
REM00K2120-IE 120 120 REM00K6100-IE 100 140
5.5 4055
REM00K4075-IE 75
140 REM00K9070-IE 70 150
7.5 4075 35
100 REM01K9070-IE 70 110
11.0 4110 REM00K6100-IE 100 50 REM02K1070-IE 70 75
15.0 4150 24
REM00K9070-IE 70 55 REM03K5035-IE 35 110
18.5 4185
REM03K5035-IE 35
90
REM19K0030-IE 30
100
22.0 4220 20 75 85
30.0 4300 4015045-TE 16 REM19K0020-IE 20 95
37.0 4370
4017068-TE 11 REM38K0012-IE 15
125
45.0 4450 100
55.0 4550
4035090-TE 8.5
2 x REM19K0020-IE 10 100
75.0 4750 3 x REM19K0030-IE 10 75
90.0 4900 4070130-TE 5.5 2 x REM38K0012-IE 6 105
110.0 411K 4090240-TE 3.2 3 x REM38K0012-IE 4
125
132.0 413K 105
Page 20
22 Frequency inverters
E Computer software
Types Model Description Installation
Software
CX-drive Computer software Configuration and monitoring software tool
CX-One Computer software Configuration and monitoring software tool
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. I116E-EN-01A
Page 21
KPP_RX_EN_INT01A
Austria
Tel: +43 (0) 2236 377 800 www.industrial.omron.at
Belgium
Tel: +32 (0) 2 466 24 80 www.industrial.omron.be
Czech Republic
Tel: +420 234 602 602 www.industrial.omron.cz
Denmark
Tel: +45 43 44 00 11 www.industrial.omron.dk
Finland
Tel: +358 (0) 207 464 200 www.industrial.omron.fi
France
Tel: +33 (0) 1 56 63 70 00 www.industrial.omron.fr
Germany
Tel: +49 (0) 2173 680 00 www.industrial.omron.de
Hungary
Tel: +36 1 399 30 50 www.industrial.omron.hu
Italy
Tel: +39 02 326 81 www.industrial.omron.it
Netherlands
Tel: +31 (0) 23 568 11 00 www.industrial.omron.nl
Norway
Tel: +47 (0) 22 65 75 00 www.industrial.omron.no
Poland
Tel: +48 (0) 22 645 78 60 www.industrial.omron.pl
Portugal
Tel: +351 21 942 94 00 www.industrial.omron.pt
Russia
Tel: +7 495 648 94 50 www.industrial.omron.ru
South-Africa
Tel: +27 (0)11 579 2600 www.industrial.omron.co.za
Spain
Tel: +34 913 777 900 www.industrial.omron.es
Sweden
Tel: +46 (0) 8 632 35 00 www.industrial.omron.se
Switzerland
Tel: +41 (0) 41 748 13 13 www.industrial.omron.ch
Turkey
Tel: +90 216 474 00 40 www.industrial.omron.com.tr
United Kingdom
Tel: +44 (0) 870 752 08 61 www.industrial.omron.co.uk
More Omron representatives
www.industrial.omron.eu
Although we strive for perfection, Omron Europe BV and/or its subsidiary and affiliated companies do not warrant or make any representations regarding the correctness or completeness of the information described in this document. We reserve the right to make any changes at any time without prior notice.
OMRON EUROPE B.V.
Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu
Automation Systems
• Programmable logic controllers (PLC) • Human machine interfaces (HMI) • Remote I/O
• Industrial PC’s • Software
Motion & Drives
• Motion controllers • Servo systems • Inverters
Control Components
• Temperature controllers • Power supplies • Timers • Counters • Programmable relays
• Digital panel indicators • Electromechanical relays • Monitoring products • Solid-state relays
• Limit switches • Pushbutton switches • Low voltage switch gear
Sensing & Safety
• Photoelectric sensors • Inductive sensors • Capacitive & pressure sensors
• Cable connectors • Displacement & width-measuring sensors • Vision systems
• Safety networks • Safety sensors • Safety units/relay units • Safety door/guard lock switches
Loading...