Omron RS6 User Manual

Thank you for purchasing the OMRON RS6 Wrist Blood Pressure
Wrist Blood
Pressure Monitor
Model RS6
Instruction Manual
IM-HEM-6221-E-01-08/2012
1883267-9A
Introduction
Important Safety Information
1. Overview
A
E
F
C
D
B
G
P
I
J
K
L
M
N
O
U
T
S
Q
R
H
2. Preparation
1) Push the button to change.
• Hold down to advance the digit rapidly.
2) Push the button to confirm.
• Next setting appears.
3. Using the Unit
Cuff Wrapping Guide
START INFLATE DEFLATE COMPLETE
Alternating date/time display
Monitor.
The OMRON RS6 is a compact and easy to use blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly. For comfortable controlled inflation without the need of pressure pre-setting or re-inflation the device uses its advanced “IntelliSense” technology.
Intended Use This product is designed to measure the blood pressure and pulse rate of people within the range of the designated wrist cuff, following the instructions in this instruction manual. It is mainly designed for general household use. Please read the Important Safety Information in this instruction manual before using the unit.
Please read this instruction manual thoroughly before using the unit. Please keep for future reference. For specific information about your own blood pressure, CONSULT YOUR DOCTOR.
Consult your doctor prior to using in pregnancy or if diagnosed with arrhythmia or arteriosclerosis. Please read this section carefully before using the unit.
Warning:
• Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
(General Usage)
• Always consult your doctor. Self-diagnosis of measurement results and self-treatment are dangerous.
• People with severe blood flow problems, or blood disorders, should consult a doctor before using the unit, as cuff inflation can cause internal bleeding.
(Battery Usage)
• If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Consult a doctor immediately.
Caution:
• Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property.
(General Usage)
• Do not leave the unit unattended with infants or persons who cannot express their consent.
• Do not use the unit for any purpose other than measuring blood pressure.
• Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit.
• Do not disassemble the unit or wrist cuff.
• Do not operate the unit in a moving vehicle (car, airplane).
(Battery Usage)
• If battery fluid should get on your skin or clothing, immediately rinse with plenty of clean water.
• Use only two “AAA” alkaline (LR03) batteries with this unit. Do not use other types of batteries.
• Do not insert the batteries with their polarities incorrectly aligned.
• Replace old batteries with new ones immediately. Replace both batteries at the same time.
• Remove the batteries if the unit will not be used for three months or more.
• Do not use new and used batteries together.
General Precautions
• Do not apply strong shocks and vibrations to or drop the unit.
• Do not take measurements after bathing, drinking alcohol or caffeine, smoking, exercising or eating.
• Do not inflate the wrist cuff when it is not wrapped around your wrist.
• Read and follow the “Important information regarding Electro Magnetic Compatibility (EMC)” in the Technical Data Section.
• Read and follow the “Correct Disposal of This Product” in the Technical Data Section when disposing of the device and any used accessories or optional parts.
Main unit:
A. Wrist cuff
B. Battery compartment
C. Display F. START/STOP button
D. Memory ( ) button
E. Date/Time setting ( ) button
Display:
G. Memory symbo l H. Systolic blood pressure I. Diastolic blood pressure J. Battery low symbol K. Heartbeat symbol
(Flashes during measurement)
L. Pulse display and Memory
number
M. Irregular heartbeat symbol
N. M ovement error symbol O. Deflation symbol P. Average value symbol Q. Date/Time display R. Blood pressure level indicator S. Positioning indicator T. Positioning symbol U. Cuff wrapping guide
2.1 Installing/Replacing the Batteries
Remove the battery cover.
1.
Insert two 1.5V “AAA”
2.
alkaline (LR03) batteries as indicated in the battery compartment and then replace the battery cover.
Notes:
• If the battery low symbol ( ) appears on the display, turn off the unit then replace both batteries at the same time.
• The measurement values continue to be stored in memory even after the batteries are replaced.
Disposal of used batteries should be carried out in accordance with the national regulations for the disposal of batteries.
2.2 Setting the Date and Time
Press the button.
1.
Set the monitor to the correct date and time
2.
before taking a measurement for the first time.
Year
Month
Day
Hour
Minute
Press the START/STOP button to store the setting.
3.
Notes:
• If the batteries have been removed, the date and time setting will need to be reset.
• If the date and time are not set, “-:--” appears during or after measurement.
3.1 Applying the Wrist Cuff
Do not apply over clothing.
Put your arm through the
1.
cuff loop.
Your palm should face upward.
Wrap the wrist cuff around
2.
your wrist.
Wrap the wrist cuff securely around the wrist for taking accurate measurements.
2
Make sure that the wrist cuff does not cover the protruding part of the wrist bone (ulna) on the outside of the wrist.
Notes:
• You can take a measurement on either your left or right wrist.
• If the wrist cu ff comes off, assemble as shown in the figure.
3.2 How to Sit Correctly
To take a measurement, you need to be relaxed and comfortably seated, under com fortable room temperature. No bathing, drinking alcohol or caffeine, smoking, exercising or eating 30 minutes before taking a measurement.
• Sit on a chair with your feet flat on the floor.
• Sit upright with your back straight.
• The cuff should be at the same level as your heart.
• Relax your wrist and hand. Do not bend your wrist back, clench your fist, or bend your wrist forward.
3.3 Taking a Reading
Notes:
• To cancel a measurement, press the START/STOP button at any time during measurement.
• Remain still while taking a measurement.
Press the START/STOP button.
1.
All the symbols appear on the display. While your position is improper, the Positioning symbol and the Positioning indicator flash, when you are in proper position the Positioning symbol lights on the display.
The monitor is in proper position.
After the Positioning symbol lights for more than 2 seconds, the wrist cuff will start to inflate automatically.
The monitor is higher than the heart.
The monitor is lower than the heart.
Cuff Wrapping Guide
The Cuff Wrapping Guide is a unique feature that indicates if the cuff is not wrapped tightly enough around the wrist. Even when the blood pressure reading will be taken.
Note: This reading is NOT reliable due to the incorrect
wrapping of the cuff. Please wrap the cuff again, taking care to wrap it correctly and take the measurement
again. When the is displayed, the cuff is correctly wrapped tightly enough on the wrist and the reading is accurate and reliable.
Undo the wrist cuff and remove the unit.
2.
Press the START/STOP button to turn off the monitor.
3.
1
The monitor automatically stores the measurement in its memory. It will automatically turn off after two minutes.
Important:
• Recent research suggests that the following values can be used as a guide to high blood pressure for measurements taken at home.
Systolic Blood Pressure Above 135 mmHg
Diastolic Blood Pressure Above 85 mmHg
This criteria is for home blood pressure measurement.
• Your blood pressure monitor includes an irregular heartbeat feature. Irregular heartbeats can influence the results of the measurement. The irregular heartbeat algorithm automatically determines if the measurement is usable or needs to be repeated. If the measurement results are affected by irregular heartbeats but the result is valid, the result is shown together with the irregular heartbeat symbol ( ). If the irregular heartbeats cause the measurement to be invalid, no result is shown. If the irregular heartbeat symbol ( ) is shown after you have taken a measurement, repeat
the measurement. If the irregular heartbeat symbol ( ) is shown frequently, please make your doctor aware of it.
• If you move duri ng measurement, the movement error symbol ( ) will appear on th e display. Keep still and repeat the measure ment.
Notes:
• Wait 2 - 3 minutes before taking another blood pressure measurement. Waiting between readings allows the arteries to return to the condition prior to taking the blood pressure measurement.
• The blood pressure can differ between the right arm and the left arm, and therefore also the measured blood pressure values can be different. OMRON recommends to always use the same arm for measurement. If the values between the two arms differ substantially, please check with your physician which arm to use for your measurement.
Warning:
Self-diagnosis of measured results and treatment are dangerous. Please follow the instructions of your doctor.
3.4 Setting the Positioning Sensor
Press and hold the
1.
button to reset the Positioning sensor. The Positioning sensor is set "on" as default.
Press the START/STOP button to store the setting.
2.
is displayed, a
Made in China
Alternating
date/time
display
4. Troubleshooting and Maintenance
5. Technical Data
OMRON HEALTHCARE Co., Ltd.
53, Kunotsubo, Terado-cho, Muko, Kyoto,
617-0002 JAPAN
OMRON HEALTHCARE EUROPE B.V.
Scorpius 33, 2132 LR Hoofddorp
THE NETHERLANDS
www.omron-healthcare.com
OMRON (DALIAN) CO., LTD.
Dalian, CHINA
OMRON HEALTHCARE UK LTD.
Opal Drive, Fox Milne, Milton Keynes, MK15 0DG
U.K.
OMRON MEDIZINTECHNIK
HANDELSGESELLSCHAFT mbH
John-Deere-Str. 81a 68163 Mannheim, GERMANY
www.omron-medizintechnik.de
OMRON SANTÉ FRANCE SAS
14, rue de Lisbonne, 93561 Rosny-sous- Bois
Cedex, FRANCE
generate strong electrical or electromagnetic fields, near the
medical device. This may result in incorrect operation of the unit
and create a potentially unsafe situation. Recommendation is to
keep a minimum distance of 7 m. Verify correct operation of the
Important information regarding Electro Magnetic
Compatibility (EMC)
With the increased number of electronic devices such as PC’s and
mobile (cellular) telephones, medical devices in use may be
susceptible to electromagnetic interference from other devices.
Electromagnetic interference may result in incorrect operation of
the medical device and create a potentially unsafe situation.
Medical devices should also not interfere with other devices.
In order to regulate the requirements for EMC (Electro Magnetic
Compatibility) with the aim to prevent unsafe product situations, the
EN60601-1-2:2007 standard has been implemented. This standard
defines the levels of immunity to electromagnetic interferences as
well as maximum levels of electromagnetic emissions for medical
devices.
This medical device manufactured by OMRON HEALTHCARE
conforms to this EN60601-1-2:2007 standard for both immunity and
emissions.
humidity, direct sunlight, dust or corrosive
vapours.
where it will be at an angle.
been carefully tested and is design ed for a long
service life.
inspected every two years to ensure cor rect
functioning and accuracy. Please consult your
• If the unit is wet.
• Locations exposed to extreme te mperatures,
• Locations exposed to vibratio ns, shocks or
• The accuracy of this blood pressure monitor h as
Do not store the unit in the followi ng situations:
Calibration and Service
authorised OMRON dealer or the OMRON
• It is generally recommended t o have the unit
Nevertheless, special precautions need to be observed:
Customer Service at the address give n on the
• Do not use mobile (cellular) telephones and other devices, which
device in case the distance is shorter.
Further documentation in accordance with EN60601-1-2:2007 is
available at OMRON HEALTHCARE EUROPE at the address
mentioned in this instruction manual.
Documentation is also available at www.omron-healthcare.com.
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
This marking shown on the product or its
literature, indicates that it should not be
disposed of, with other household wastes at the
end of its working life.
To prevent possible harm to the environment or human health from
uncontrolled waste disposal, please separate this product from
other types of wastes and recycle it responsibly to promote the
sustainable reuse of material resources.
Household users should contact either the retailer where they
purchased this product, or their local government office, for details
of where and how they can return this item for environmentally safe
recycling.
Business users should contact their supplier and check the terms
and conditions of the purchase contract. This product should not be
mixed with other commercial wastes for disposal.
Manufacturer
EU-representative
Production Facility
Subsidiary
Pulse: 40 to 180 beats/min.
Pulse: ±5% of display reading
alkaline batteries at a room temperature of
23°C
Internally powered ME equipment
+10 to +40°C / Maximum: 30 to 85% RH
-20 to +60°C / Maximum: 10 to 95% RH /
700 to 1060hPa
14 (d) mm (without the wrist cuff)
Approximately 13.5 to 21.5 cm
instruction manual, guarantee card, blood
pressure pass
packaging or attached literature.
(Medical Device Directive).
Standard EN1060, Non-invasive sphygmomanometers Part 1:
General Requirements and Part 3: Supplementary requirements
for electromechanical blood pressure measuring systems.
OMRON HEALTHCARE Co. Ltd., Japan. The Core component for
OMRON blood pressure monitors, which is the Pressure Sensor, is
Product Description Wrist Blood Pressure Monitor
Model OMRON RS6 (HEM-6221-E)
Display LCD Digital Display
Measurement Method Oscillometric method
Note: Subject to technical modification without prior notice.
• This device fulfils the provisions of EC directive 93/42/EEC
Measurement Range Pressure: 0 to 299 mmHg
Accuracy Pressure: ±3 mmHg
Inflation Automatic inflation by pump
Deflation Automatic rapid deflation
Memory 90 Measurements
Power Source 2 x 1.5V (LR03, AAA alkaline batteries)
Battery Life Approx. 300 measurements with new
Applied Part = Type B
Protection Against
Electric Shock
Operating temperature/
Humidity
Storage temperature/
Humidity/Air pressure
Console Weight Approximately 85 g without batteries
Outer Dimensions Approximately 87 (w) mm x 64 (h) mm x
Measurable
circumference
Cuff Material Nylon and polyester
Package Content Main unit, storage case, battery set,
• This blood pressure monitor is designed according to the European
produced in Japan.
• This OMRON product is produced under the strict quality system of
Measure while in the
correct posture.
Refer to section 3.2.
Wrap the cuff correctly.
Refer to section 3.1.
Relax and try taking the
measurement again.
Refer to section 3.3.
Remain still and do not
talk during Measurement.
Refer to section 3.3.
Consult your OMRON
retail outlet or distributor.
Apply the cuff correctly so
that it is firmly wrapped
around the wrist. Refer to
section 3.1.
Blood pressure readings
constantly vary with time
of day and how relaxed
you are. Take several
deep breaths and try to
remain relaxed before
taking a measurement.
Replace the batteries with
new ones.
Refer to section 2.1.
Insert the batteries with
the correct (+/-) polarity.
Refer to section 2.1.
measurement.
batteries with new ones.
incorrectly.
• Press the START/STOP button and repeat
• If the problem continues, try replacing the
If this still does not solve the problem, contact
your OMRON retail outlet or distributor.
extreme temperatures, humidity, moisture or
direct sunlight.
vibrations (for example, dropping the unit on the
floor).
clean the cuff.
defect occurs, consult your OMRON retail outlet
• Do not subject the main unit and the cuff to
• Do not disassemble the unit.
• Do not subject the unit to strong s hocks or
• Do not use volatile liquid s to clean the main unit.
• Do not wash the cuff or immerse it in water.
Other problems.
4.3 Maintenance
To protect your unit from damage, please observe the
following:
or distributor as mentioned on the packaging.
• Do not use petrol, thinner s or similar solvents to
• Do not carry out repairs of any kind yourself. If a
clean the cuff.
use.
• The unit should be cleaned with a soft, dry cloth.
• Use a soft, moistened cloth and neut ral soap to
• Keep the unit in its storage case wh en not in
• Fold the cuff into the storage case.
4.2 Troubleshooting
The wrist cuff is not
at heart level.
The cuff is not
wrapped snugly
around the wrist.
The arms and
shoulders are
tense.
Movement or
talking during
measurement.
Air is leaking from
the wrist cuff.
The wrist cuff is
loose.
Problem Cause Remedy
The reading is
extremely low
(or high).
Wrist cuff pressure
does not rise.
Wrist cuff deflates
too soon.
The blood pressure is different
each time. The reading is
extremely low (or high).
The batteries are
The unit loses
power during
measurement.
exhausted.
The batteries have
been inserted
Nothing happens
when you press
the buttons.
Remove the wrist cuff. Wait
2 - 3 minutes and then take
another measurement.
Repeat the steps in section
3.3. If this error continues to
appear, contact your doctor.
Carefully read and repeat the
steps in section 3.3.
You should replace them with
new ones ahead of time.
Refer to section 2.1.
You should replace them with
new ones at once.
Refer to section 2.1.
Apply the wrist cuff correctly.
Refer to section 3.1.
Repeat Measurement while
remaining still and refraining
from talking during the
measurement.
Refer to section 3.3.
Apply the wrist cuff correctly
and repeat measurement
while remaining still and
refraining from taking during
the measurement.
Refer to section 3.1 and 3.3.
Remain still until the
measurement is complete.
Refer to section 3.3.
Contact your OMRON retail
outlet or distributor.
Irregular heartbeats
are detected.
Movement during
measurement.
The batteries are
low.
The batteries are
exhausted.
Wrist cuff not
applied correctly.
Movement during
measurement.
Wrist cuff not
applied correctly, or
movement during
measurement.
Arm position
changed during
measurement.
results stored in the memory, the
readings.
The monitor automatically stores the result up to 90 sets.
It can also calculate an average reading based on the
measurements from the last three readings taken within 10
minutes. If there are only two readings in memory for that
period, the average will be based on two readings. If there is
one reading in memory for that period, the average will be
3.5 Using the Memory Function
time, “-:--” is displayed instead of the date and time.
based on one reading.
Notes:
• If the memory is full, the monitor will delete the oldest
• When viewing the reading taken without setting the date and
Press the button.
To View the Average Value
Note: If there are no measurements
screen to the right is displayed.
Press the button, while the average value is
1.
To View the Readings Stored in Memory
displayed.
The Memory number
appears for a second
before the pulse rate is
displayed. The newest
set is numbered “1”.
Press the button repeatedly to view the
readings stored in memory.
2.
button. Then while holding it down, press the
START/STOP button simultaneously for about 2 - 3
seconds.
When the memory symbol ( ) appears, first press
the
To Delete All the Values Stored in Memory
First Second
Note: You cannot partially delete the stored readings.
Error Display Cause Remedy
4.1 The Icons and Error Messages
Blink
Lit
Device error.
symbol ( ) may also be displayed with error messages.
Note: The irregular heartbeat symbol ( ) and the movement error
Loading...