Omron NSJ BROCHURE

NSJ Series
Specifications
Ivory Black Ivory Black Ivory Black Ivory Black Ivory Black Ivory Black
Ivory Black Ivory Black Ivory Black Ivory Black
Display Section
117.2 x 88.4 (W x H) mm (5.7-inch model)
162.2 x 121.7 (W x H) (8.4-inch model)
215.2 x 162.4 (W x H) mm (10.4-inch model)
246.0 x 184.5 (W x H) mm (12.1-inch model)
NSJ5-TQ00-G5D NSJ5-TQ00B-G5D NSJ5-TQ01-G5D NSJ5-TQ01B-G5D NSJ5-SQ00-G5D NSJ5-SQ00B-G5D NSJ5-SQ01-G5D NSJ5-SQ01B-G5D NSJ8-TV00-G5D NSJ8-TV00B-G5D NSJ8-TV01-G5D NSJ8-TV01B-G5D NSJ10-TV00-G5D NSJ10-TV00B-G5D NSJ10-TV01-G5D NSJ10-TV01B-G5D NSJ12-TS00-G5D NSJ12-TS00B-G5D NSJ12-TS01-G5D NSJ12-TS01B-G5D
Controller Section
I/O capacity: 1,280 points Program capacity: 60K steps Data memory capacity: 128K words (DM: 32K words, EM: 32K words x 3 banks) Function blocks supported (algorithms: ladder diagram or ST language)
Display device Frame color Effective display area Resolution
High-definition TFT color LCD
Color STN LCD
High-definition TFT color LCD
Other specifications
NSJ5-TQ00-G5D NSJ5-TQ00B-G5D NSJ5-TQ01-G5D NSJ5-TQ01B-G5D NSJ5-SQ00-G5D NSJ5-SQ00B-G5D NSJ5-SQ01-G5D NSJ5-SQ01B-G5D NSJ8-TV00-G5D NSJ8-TV00B-G5D NSJ8-TV01-G5D NSJ8-TV01B-G5D NSJ10-TV00-G5D NSJ10-TV00B-G5D NSJ10-TV01-G5D NSJ10-TV01B-G5D NSJ12-TS00-G5D NSJ12-TS00B-G5D NSJ12-TS01-G5D NSJ12-TS01B-G5D
RS-232C
Slave USB port
One port One port
Three ports Display Section: A and B Controller Section: C
port
DeviceNet port
Ethernet port
None
10/100 Base-T
None
10/100 Base-T
None
10/100 Base-T
None
10/100 Base-T
None
10/100 Base-T
Printer USB port
None
One port
Display color
256 colors (32,768 colors for BMP/JPEG images)
Display SectionBuilt-in port
View angle
Left/right ±70°, Top 75°, Bottom 50°
Left/right ±50°, Top 45°, Bottom 50°
Left/right ±65°, Top 50°, Bottom 60°
Left/right ±60°, Top 35°, Bottom 65°
Left/right ±60°, Top 45°, Bottom 75°
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
320 x 240 (QVGA)
640 x 480 (VGA)
800 x 600 (SVGA)
Standard
Language
screen data capacity
20 MB
Japanese and English
60 MB
This catalog mainly provides information that is necessary for selecting suitable models, and does not contain precautions for correct use. Always read the precautions and other required information provided in product operation manuals before using the product.
The application examples provided in this catalog are for reference only. Check functions and safety of the equipment before use. Never use the products for any application requiring special safety requirements, such as nuclear energy control systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, or other application involving serious risk to life or property, without ensuring that the system as a whole has been designed to address the risks, and that the OMRON products are properly rated and installed for the intended use within the overall equipment or system.
Options and Expansion Units
Name
Memory Card (for the Controller Section and Display Section)
NSJ Controller Link Unit
Expansion Unit
NSJ Ethernet Unit
NSJ I/O Control Unit
Model Specifications HMC-EF372 Flash Memory, 30 MB HMC-EF672 Flash Memory, 64 MB HMC-AP001 Memory Card Adaptor
NSJW­CLK21-V1
NSJW­ETN21
NSJW-IC101
Addition of Controller Link port. Same as the Controller Link Unit for CJ-series PLCs (CJ1W-CLK21-V1).
Addition of Ethernet port. Same as the Ethernet Unit for CJ-series PLCs (CJ1W­ETN21).
Addition of CJ-series Expansion Racks. Same as CJ-series I/O Control Unit (CJ1W­IC101).
CX-One
Standard Models
Name
The CX-One is an integrated tool pack that provides programming and monitoring
CX-One FA Integrated Tool Package Ver. 1.1
Site licenses are also available for users that need to use the CX-One on many computers. Ask your OMRON representative for details.
software for OMRON PLCs and components. The CX-One runs on any of the following operating systems: Windows 98 SE, Me, NT 4.0 (Service Pack 6a), 2000 (Service Pack 3 or higher), or XP. CX-Designer version 1. is included in the CX-One. Refer to the CX-One catalog (R134) for details.
CX-One Operating Environment
Compatible OS
Recommended CPU
Recommended memory
Hard disk free space
CD-ROM drive Required for installation
Display
Note 1: CX-One OS precaution The CX-One will not run on Microsoft Windows 95 or any other OS not listed above. If such an OS is being used on the client computer, the OS must be upgraded before installing the CX-One. System requirements and hard disk space may vary with the system environment. 2: The amount of memory required varies the Support Software applications used in CX-One. Refer to use documentation for Individual Support Software for details.
Specifications
Windows 98 SE, Me, NT 4.0 (Service Pack 6a), 2000 (Service Pack 3 or higher), or XP (See note 1.)
Pentium II 333 MHz or faster processor (Pentium III 1 GHz or faster recommended.)
256 Mbytes min. (See note 2.)
Approx. 1.8 GB or more available space is required to install the complete CX-One package.
SVGA (800 x 600) or better high-resolution display with 256 colors min.
1 license
3 licenses
10 licenses
30 licenses
50 licenses
Model
CXONE­AL01C-E
CXONE­AL03C-E
CXONE­AL10C-E
CXONE­AL30C-E
CXONE­AL50C-E
Programmable Controller
NSJ Series
HMI Integrated into a Controller. The New SYSMAC One One-package Controller for High-precision Control
Note: Do not use this document to operate the Unit.
OMRON Corporation
Control Devices Division H.Q.
Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7109 Fax: (81)75-344-7149
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, NL-2132 JD Hoofddorp The Netherlands Tel:(31)2356-81-300/ Fax: (31)2356-81-388
OMRON ELECTRONICS LLC
1 East Commerce Drive, Schaumburg, IL 60173 U.S.A. Tel: (1)847-843-7900/Fax :(1)847-843-8568
OMRON ASIA PACIFIC PTE. LTD.
83 Clemenceau Avenue, #11-01, UE Square, Singapore 239920 Tel:(65)6835-3011/Fax : (65)6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120 China Tel: (86)21-5037-2222/Fax: (86)21-5037-2200
Printed on 100% Recycled Paper
Authorized Distributor:
Note: Specifications subject to change without notice. Cat. No. V403-E1-01
Printed in Japan 0206-1M
Full Lineup of Models in the 5.7" to 12" Class and Expansion Units
Controller Shapes and Functions Designed to Respond to Customer Requirements for More Compact Machines The New SYSMAC One One-package Controller NSJ Series
One-package Construction Saves Space and Makes Life EasyOne-package Construction Saves Space and Makes Life Easy
One-package Construction Saves Space and Makes Life Easy
Numerous customers have requested even smaller control
Save Space
panels. We recognized, however, that there are limits when combining separate HMI and controllers. Therefore, we redesigned the shape of the Controller. With it's all-in-one design, the SYSMAC One NSJ Series saves space as well as provides a variety of advantages.
PLC
Control panel
Display
Control panel
The PLC is located behind the HMI and the terminal blocks are placed underneath, so the
Issue
layout is extended vertically.
A change in the PLC configuration extends the arrangement horizontally, requiring redesigning
Issue
of the panel.
PLC
Terminal blocks
SYSMAC One
Reduction above and
below
Place the terminal blocks behind the HMI!
Solution
Use only
a single panel.
SYSMAC One
No need to redesign the panel. The width left and right remains unchanged. Panel
Solution
redesigning is not required!
Integrated Software
Best match with FA Integrated Tool Package CX-One
By using FA Integrated Tool Package CX-One, NS/NJ-series design tool (CX­Designer) and the network setting tool (CX­Integrator) can be called up from ladder programming tool (CX­Programmer).
FA Integrated Tool Package CX-One version 1.1
USB cable
Note: The 5.7-inch NSJ5 is pictured.
Precise Control Even from
Precise Control Even from
Precise Control Even from
an Integrated Product
an Integrated Product
an Integrated Product
Equivalent to the SYSMAC CJ-series PLCs
The SYSMAC One NSJ Series is a series of controllers that include a CPU Unit equivalent to that of the SYSMAC CJ-series CJ1G-CPU45H. The Display Section also includes a CPU for display. The control programming therefore remains completely unaffected even if there is a failure in the Display Section due to the load on it.
Continue Using Your Assets and Support Tool
Continue to use all the screen data for NS-series HMIs and ladder programs for CS/CJ-series PLCs.The CX-Designer for NS-series HMI and the CX-Programmer for ladder programming can be used as the Support Software (see note), so customers who have been using these software packages have no need to learn new software. Function blocks and the Smart Active Part libraries can of course also be used.
Smart FB
FB
(Controller CPU of NSJ Controller)
%BBBB
(BOOL) EN (INT) UnitSelect (INT) PortNo
&1
(INT) TCNo
&2
(INT) ChannelNo
&2
_E5xx203_ReadSP
Processing after detecting the target value
(BOOL)
(BOOL)
(BOOL)
(BOOL)
(DINT)
ENO
BUSY
OK
NG
SP
Processing Flag Bit B Normal Completion Flag Bit C Error Completion Flag Bit D Target value D100
Target value (upper word)
D101
Target value (lower word)
D100
Bit A
Connection source
Unit specification
Bit B
Serial port number
Temperature Controller unit number
Word number
Bit C
Smart Active Parts
Active
window
The Smart Active Parts are accessed by selecting
Library
from the menu
bar of the CX-Designer.
(Display Section of
Note: SYSMAC One NSJ-series NSJ Controllers are supported by CX-One version 1.1 or higher.
Tools
NSJ Controller)
Slim NSJ-series Controller Construction
Expansion Unit (optional)
One Unit can be mounted. The Unit is only 16 mm thick.
DeviceNet as a standard feature
Only 73.3 mm (for the NSJ8/10/12)
Dimensions
(Unit: mm)
NSJ12-TS0 (B)-G5D/NSJ10-TV0 (B)-G5D
No Expansion Unit
32.2
43.6
323 315 264
NSJ8-TV0 (B)-G5D
No Expansion Unit
8.4
45.7
232 180
15.5
Controller Section: Controller CPU and DeviceNet
The CPU is equivalent to the CJ1G-CPU45H CPU Unit. The serial port is an RS-232C port built into the CPU. The Controller Section is equipped with DeviceNet as a standard feature for I/O.
Display Section: Touch Panel NS-series PT
The touch panel is based on the NS-V2 PTs. Communications with the Controller Section are performed using the Controller Section's internal bus.
7.8
69.1
140
241
NSJW-CLK21-V1 Mounted
NSJW-CLK21-V1 Mounted
227
7.5
15.5
73.3 (NSJ10/12 max. dimensions)
89.3 (with Expansion Unit mounted)
55.6
64.5
39 (min.) 42 (max.)
1.1
(90.4)
249
CX-Programmer
CX-Designer
CX-Integrator
Easy and Fast Data Transfer Using an Off-the-shelf USB Cable.
Ladder program from CX-Programmer and screen data from CX-Designer can be quickly transferred. And both the Controller Section and Display Section can be online at the same time. Naturally, no cable connection or difficult communications settings are required. The connection starts simply by turning ON the power supply.
Easy Diagnosis
Built-in Troubleshooter for the Controller CPU and DeviceNet
If there is a failure in the Controller CPU or a DeviceNet master or slave, information on the failure and the possible countermeasure is displayed. The user can quickly apply remedies for errors when they occur without referring to the manual.
Memory Backup Using a Memory Card
In addition to display screens, Controller Section programming can also be backed up by following on-screen instructions.
Memory Card
Expandable System
The system can be expanded with one Expansion Unit (Controller Link Unit, Ethernet Unit or I/O Control Unit). By using an I/O Control Unit, any CJ-series Unit until now can be used.
Expansion Unit
Click
Click
Controller Link Unit
Any one Unit
CJ-series Expansion Racks (3 Racks max.)
Expansion Cable
Ethernet Unit
I/O Control Unit
177
165
39 (min.)
73. 3 (NSJ8 max. dimensions
89.3 (with Expansion Unit mounted)
NSJ5-SQ00 (B)-G5D/NSJ5-TQ0 (B)-G5D
No Expansion Unit
6.5
81.5
145 195
206.3
77
15.5
95 (with Expansion Unit mounted)
23.7
25.4
44.55
25
142
79 (NSJ5 max. dimensions)
42 (max.)
(90.4)
NSJW-CLK21-V1 Mounted
130.5
34 (min.)
5
38 (max.)
53.8
(96.1)
188
1.1
153.3
1.1
Loading...