Introduction
The OMRON MX2 Basic measures your blood pressure and pulse simply and quickly
from the arm, without the use of an inflation bulb or stethoscope.
The OMRON MX2 Basic includes a standard cuff for arm circumferences ranging from
22-32 cm. Optional large cuffs (32-42 cm) can be applied.
Table of contents
1 How to obtain meaningful blood
pressure readings1
2 Overview2
3 Preparation3
4 Operation4
5 Error: causes and rectifications7
6 Maintenance and spare parts7
7 Technical data8
8 General information about blood
pressure10
1 How to obtain meaningful blood pressure readings
General
• The OMRON MX2 Basic is not suitable
for measuring the frequency of cardiac
pacemakers.
• Consult your doctor during pregnancy,
arrhythmia and arteriosclerosis as this
can influence the measurement.
• Avoid eating, drinking (alcohol),
smoking, sport and taking a bath before
measurement.
• Be calm and relaxed before and during
measurement.
• You should never change the dose of
medicines prescribed by your doctor.
1
EA
D
C
FBG
D
IA
m
m
H
g
S
Y
S
m
m
H
g
P
U
L
S
E
/m
in
M
X
2
B
a
s
i
c
MX2 Basic English
• Store the OMRON MX2 Basic in a dry,
closed place with a temperature
between -20°C and 60°C.
• Remove the batteries if you not intend
to use the OMRON MX2 Basic for 3
months or more.
Tips for use
• Check your blood pressure at least twice
a day (before breakfast, after work).
• Do not measure your blood pressure
while you are in a vehicle.
• Always measure on the same arm.
• Wrap the cuff around your arm before
start of measurement.
2 Overview
Caution
• Operating temperature between 10°C
and 40°C.
• Operating environment must be free
from excessive vibrations, shocks,
magnetic fields, electrical noise, etc.
• Stay out of sunlight during measuring.
• Keep portable phones 5 meters away
during measurement.
• Do not wrap the cuff around any object
other than your arm.
• Do not fold the cuff and the tube.
• Do not drop the OMRON MX2 Basic.
A Display
B Start button
C On/off button
2
D AC adapter jack
E Cuff
F Air tube
G Air plug
H Battery
compartment
H
J
J Air jack
MX2 Basic English
P
U
L
S
E
/
m
i
n
S
Y
S
m
m
H
g
D
IA
m
m
H
g
M
X
2
B
K
F
1-2 cm
3 Preparation
Insert batteries
1 Slide off the battery cover.2 Insert four batteries as indicated in the
battery compartment and close
compartment
Caution! Use four identical 1.5V
batteries type AA!
Connect cuff
1 Insert air plug in air jack.
K Ring
2 Pass the end of the cuff through the ring.
Caution! Keep the air tube on the
outside!
Fit cuff
Caution! Do not inflate the cuff when not
wrapped around the arm!
1 Bare your arm.
Caution! Push up your sleeve: avoidconstricting the blood flow!F Air tube
3 Put your arm through the loop.
Note: keep the tube even with your
middle finger.
3
MX2 Basic English
PULSE/min
DIA
mmHg
SYS
mmHg
MX2 Basic
C
B
N
L
M
S
R
Q
P
1-2 cm
Note: for right arm use keep the tube
parallel with your little finger!
4 Operation
Control functions
B Start button
C On/off button
Measurement
L Systolic blood pressure in mmHg.
M Heart symbol: flash - measurement
4
takes place, light up - finish
measurement.
4 Hold the end of the cuff and wrap it
around your arm.
Caution! Be sure the cuff fits closely;
do not pinch your arm!
N Diastolic blood pressure in mmHg.
P Pulse: heartbeats per minute.
Q Battery exhausted: batteries are
weak/exhausted.
R Deflation: cuff deflates and
measurement finishes.
S Inflation: cuff inflates and measurement
starts.
MX2 Basic English
PULSE/min
DIA
mmHg
SYS
mmHg
MX2 BasicMX2 BasicMX2 Basic
Caution! Allow an interval of at least three minutes between two successive measurements!
1 Sit comfortably at a table with your feet
flat on the floor and rest your arm on
the table.
2 Relax your arm and turn your palm
upward.
Caution! Cuff at heart height during
measurement!
SYS
mmHg
DIA
mmHg
PULSE/min
3 Press on/off button.
Caution! Wait for zero and the heart symbol to continue!
MX2 Basic
SYS
mmHg
DIA
mmHg
PULSE/min
4 Press start button
Note: the unit inflates the cuff to 170
mmHg. If required the unit
automatically increases the pressure by
Note: press and hold the start button to
set pressure higher than 170 mmHg.
Caution! Do not inflate over 280
mmHg!
40 mmHg.
SYS
mmHg
DIA
mmHg
PULSE/min
5
MX2 Basic English
MX2 Basic
PULSE/min
DIA
mmHg
SYS
mmHg
MX2 Basic
PULSE/min
DIA
mmHg
SYS
mmHg
MX2 Basic
PULSE/min
DIA
mmHg
SYS
mmHg
MX2 BasicMX2 Basic
SYS
mmHg
DIA
mmHg
PULSE/min
Note: the cuff deflates automatically.Caution! Sit still, do not move and do not
speak!
Read display
SYS
mmHg
DIA
mmHg
PULSE/min
1 Read the values of blood pressure and pulse from the display.
Note: display shows blood pressures and heartbeats alternately.
2 Note values in your personal blood
pressure pass.
6
MX2 Basic
SYS
mmHg
DIA
mmHg
PULSE/min
3 Press on/off button to turn off power.
Note: power automatically shuts off in 5
minutes.
5 Error: causes and rectifications
IndicationErrorCauseRectification
MX2 Basic English
Correct Cuff pressure
reading low
not
possibleMovement
Very weak
artery pulse
Cuff pressure
too high
Low Batteries weak/ Fit four new identical 1.5V
voltageexhaustedbatteries type AA
Display empty
6 Maintenance and spare parts
• Use a soft, slightly moistened cloth to
clean the OMRON MX2 Basic.
Caution! Do not use petrol, thinners or
similar solvents!
• Use a soft, moistened cloth and soap to
clean the cuff.
Caution! Do not wash the cuff!
Caution! Do not use petrol, thinners or
similar solvents!
• Do not carry out repairs of any kind
yourself. If a defect occurs consult your
Wait for at least three minutes to repeat
measurement.
Inflate the cuff 40 mmHg higher than
previous value.
Follow instructions, repeat
measurement.
Wait for at least three minutes to repeat
measurement.
Inflate the cuff 30 mmHg lower than
previous value.
Follow instructions, repeat
measurement.
OMRON retail outlet or distributor as
mentioned on the packaging.
Calibration
• It is recommended to have the OMRON
MX2 Basic inspected every two years to
ensure correct function and accuracy.
Consult your OMRON retail outlet or
OMRON distributor as mentioned on the
packaging.
Replace batteries
• Remove the battery out of the battery
7
MX2 Basic English
compartment and insert four new identical
1.5V batteries type AA.
Spare parts
• Due to high company quality standards,
OMRON considers the main unit as a
non-serviceable part because the need
of high tech components.
Attention! Disposal of batteries and the
OMRON MX2 Basic should be
carried out in accordance with
the national regulations for the
disposal of electronic products.
InflationAutomatic by electric pump
DeflationAutomatic pressure release valve
Rapid pressure releaseAutomatic exhaust valve
Pressure detectionCapacitive pressure sensor
Measurement methodOscillometric method
Power supply4 x 1.5V batteries type AA
Battery lifeNew batteries will last for approximately 300 measurements
Operating temperature/humidity +10°C to +40°C / 30% to max. 85% relative humidity
Operating environmentFree from excessive vibrations, shocks, magnetic fields,
Storage temperature/humidity-20°C to +60°C /10% to max. 95% relative humidity
WeightApproximately 350 g including cuff, excluding batteries
Outer dimensionsApproximately 118 mm (W) x 90 mm (H) x 130 mm (D)
Cuff dimensionsApproximately 145 mm (W) x 480 mm (L)
Arm circumference22 cm to 32 cm
AccessoriesCuff, instruction manual, guarantee card, blood pressure pass
Optional partsLarge cuff for arm circumferences between 32 - 42 cm, AC adapter
NoteSubject to technical modification without prior notice
= Type B
ManufacturerOMRON HEALTHCARE Co., Ltd.
EU-representativeOMRON HEALTHCARE EUROPE B.V.
This device fulfils the provisions of the EC directive 93/42/EEC (Medical Device Directive). This blood
pressure monitor is designed according to the European standard EN1060, Non-invasive
sphygmomanometers Part 1: General Requirements and Part 3: Supplementary requirements for
electromechanical blood pressure measuring systems.
Pulse: ± 5% of display reading
AC adapter (optional part)
electrical noise, etc.
24, Yamanouchi Yamanoshita-cho, Ukyo-ku, Kyoto, 615-0084 Japan
Kruisweg 577, NL-2132 NA Hoofddorp
8
MX2 Basic English
Important information regarding Electro Magnetic Compatibility (EMC)
With the increased number of electronic devices such as PC.s and mobile (cellular) telephones,
medical devices in use may be susceptible to electromagnetic interference from other devices.
Electromagnetic interference may result in incorrect operation of the medical device and create a
potentially unsafe situation.
Medical devices should also not interfere with other devices.
In order to regulate the requirements for EMC (Electro Magnetic Compatibility) with the aim to
prevent unsafe product situations, the EN60601-1-2 standard has been implemented. This
standard defines the levels of immunity to electromagnetic interferences as well as maximum
levels of electromagnetic emissions for medical devices.
This medical device manufactured by OMRON Healthcare conforms to this EN60601-1-2:2001
standard for both immunity and emissions.
Nevertheless, special precautions need to be observed:
• Do not use mobile (cellular) telephones and other devices, which generate strong electrical or
electromagnetic fields, near the medical device.This may result in incorrect operation of the unit
and create a potentially unsafe situation. Recommendation is to keep a minimum distance of
7 m. Verify correct operation of the device in case the distance is shorter.
Further documentation in accordance with EN60601-1-2:2001 is available at OMRON Healthcare
Europe at the address mentioned in this instruction manual.
Documentation is also available at www.omron-healthcare.com.
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
This marking shown on the product or its literature, indicates that it should not be
disposed of, with other household wastes at the end of its working life.To prevent
possible harm to the environment or human health from uncontrolled waste disposal,
please separate this from other types of wastes and recycle it responsibly to promote the
sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their
local government office, for details of where and how they can take this item for environmentally
safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase
contract. This product should not be mixed with other commercial wastes for disposal.
This product does not contain any hazardous substances.
9
8 General information about blood pressure
MX2 Basic English
Blood circulation
The blood circulation is responsible for
supplying the body with oxygen. Blood
pressure is the pressure exerted on the
arteries.
The systolic blood pressure value (higher
pressure or top value) represents the
blood pressure produced by contraction of
the heart muscle.
The diastolic blood pressure value (lower
pressure or lower value) represents the
blood pressure produced by relaxation of
the heart muscle.
Classification of blood pressure
The World Health Organisation (WHO)
and the International Society of
Hypertension (ISH) developed the blood
pressure classification. This classification
is based on the blood pressure values
measured while sitting on a chair in the
outpatient department of a hospital.
Systolic blood pressure
(mmHg)
180
160
140
Normal systolic value
130
Normal blood
120
Optimal blood
pressure
(target value)
According to the blood pressure classification by the WHO/ISH.
10
Health and blood pressure
The incidence of hypertension increases
with age. In addition, a lack of exercise,
excess body fat and high levels of cholesterol (LDL), which sticks to the inside in
blood vessels, reduces elasticity of these
vessels. Hypertension accelerates arterial
sclerosis which can lead to very serious
conditions such as stroke and myocardial
infarction. For these reasons it is very
important to know whether the blood
pressure is within a healthy range. Blood
pressure fluctuates from minute to minute,
throughout the day. Therefore it is essential
to take regular measurements to help you
identify an average blood pressure.
Symptoms of high blood pressure
High blood pressure can go unnoticed for
a long time, since it does not cause noticeable symptoms.The following are all
possible causes of abnormally high blood
pressure:
• Underlying illnesses, such as kidney
disorders or endocrine disturbance
Blood pressure measurement
Measuring your blood pressure daily
enables you to recognize high blood
pressure at an early stage and obtain
medical treatment.
The oscillometric method of measurement
determines your blood pressure by
measuring the pressure fluctuations
caused by the pulse waves.
Since your blood pressure fluctuates
within a day (see graphic next page), you
should always measure it at the same
time each day to ensure that the
measurements are genuinely comparable.
At the doctor’s surgery, nervousness and
tension may cause your blood pressure to
be higher than in familiar circumstances at
home. This is known as “White Coat
Hypertension”.
Treatment of high blood pressure
If your blood pressure reaches upper
values of 140 - 160 mmHg and lower
values of 90 - 95 mmHg in repeated
measurements over several days, you
should consult your doctor for detailed
medical examination.You can assist the
treatment prescribed by your doctor in the
following ways:
• Loose weight and lower your cholesterol
level by reducing the calories and fat in
your diet. Cut down on animal fats and
eat more fruit and vegetables.
• Reduce the consumption of alcohol.
• Reduce the intake of salt: the German
League for Combating High Blood
Pressure recommends six grams of salt
per day (i.e. one teaspoon) on average.
• Stop smoking.
• Take regular exercise.
• Monitor your blood pressure.
Example: fluctuation within a day (male, 35 years old)
11
Manufacturer
EU-representative
Production Facility
Subsidiary
MX2 Basic English
OMRON HEALTHCARE CO., LTD.
24, Yamanouchi Yamanoshita-cho, Ukyo-ku,
Kyoto, 615-0084 Japan
OMRON HEALTHCARE EUROPE B.V.
Kruisweg 577, 2132 NA Hoofddorp,
The Netherlands
www.omron-healthcare.com
OMRON DALIAN CO., LTD.
Economic & Technical Development Zone
Dalian 116600, China
OMRON HEALTHCARE UK LTD.
Opal Drive
Fox Milne, Milton Keynes MK15 0DG, United Kingdom