Omron IntelliSense IA1B Instruction Manual

INSTRUCTION MANUAL
Automatic Blood Pressure Monitor
with Fit Cuff
=Fit Cuff= !"#$%
Model
I
A
1
B
Contents
Introduction ...................................................................... 2
Notes on Safety ................................................................ 3
Know Your Unit ................................................................. 5
Quick Reference Guide ...................................................... 7
Initial Set-Up ..................................................................... 9
How to Install and Replace Batteries ..........................................9
How to Set the Date and Time ................................................10
Correct Usage ................................................................. 13
How to Apply the Arm Cuff .................................................... 13
How to Take a Measurement .................................................. 16
How to Use the Memory Function ........................................... 20
Troubleshooting ............................................................... 22
Care and Maintenance .................................................... 24
Specifications .................................................................. 25
1
Introduction
Thank you for purchasing the IA1B Omron Automatic Blood Pressure Monitor with IntelliSense no self adjustment is necessary as the monitor intelligently adjusts to your changing conditions. The IntelliSense sense both your systolic and diastolic blood pressure values, and the result is personalized inflation for every reading. This virtually eliminates discomfort or incorrect readings due to improper cuff inflation.
IA1B also stores up to 90 sets of measurements in memory and displays
The an average reading based on the three most recent measurements.
Please read this instruction manual thoroughly before using the unit. For specific information about your own blood pressure, consult your doctor.
TM
. Although your blood pressure fluctuates throughout the day,
TM
monitor uses fuzzy logic intelligence to
2
Notes on Safety
• The warning signs and the sample icons shown here are listed in order for you to use the product safely and correctly, as well as to prevent the risk of damage or injury to you and others from happening.
• The icons and meanings are as follows.
WarningSign Contents
Indicates matters in which bodily harm or material
Caution
* Material damage refers to a wide range of damage involving your house, household goods, domestic animals, and pets.
The icon indicates actions that are prohibited (what you
damage* may arise as a result of incorrect handling.
Examples of Signs
cannot do). Matters involving prohibited actions are indicated by text or pictures in or near the icon.
The followed. Matters involving compulsory actions are indicated by text or pictures in or near the compulsory items.
icon indicates compulsory actions that must always be
icon. The icon indicates general
Caution
Self-diagnosis of measured results and treatment are dangerous. Please follow the instructions of your doctor.
Do not use the unit on infants or persons who cannot express their consent.
Do not use the unit for any purpose other than measuring blood pressure.
Do not use a cellular phone near the unit. This may result in incorrect operation of the unit.
3
Notes on Safety
Caution
Do not forcibly bend the arm cuff or bend the air tube excessively. When removing the air tube, pull on the air plug at the connection with the
main unit not the tube itself. Do not apply strong shocks and vibrations to or drop the main unit. Do not inflate the arm cuff when it is not wrapped around your arm. When using batteries, the battery liquid may leak and damage the main unit.
Please observe the following points.
• When you are not going to use the unit for a long period of time (approximately three months or more), take out the batteries.
• Replace old batteries with new ones immediately.
• Do not use old and new batteries together.
• Do not insert the batteries with their polarities incorrectly aligned.
4
Main Unit:
Know Your Unit
Display
I
A
1
B
START/STOP Button
Battery Compartment
Memory
Date/Time Setting
Display:
Systolic Blood Pressure
Diastolic Blood Pressure
Memory Symbol
Average Value Symbol
Movement Error Symbol
Air Jack
AC Adapter Jack
Heartbeat Symbol
Pulse Display
Deflation Symbol
Date/Time Display
Battery Low Symbol
Irregular Heartbeat Symbol
5
Accessories:
Arm Cuff
Air Plug (Connects to Air Jack)
Know Your Unit
Air Tube
Four batteries
Storage Case
6
Quick Reference Guide
To help ensure a reliable reading, avoid eating, smoking, exercising for at least 30 minutes before taking a measurement. You should also try to measure your blood pressure at the same time each day.
1. Remove any tight-fitting clothing from your upper arm.
2. Sit on a chair with your feet flat on the floor and place your arm on a table so that the arm cuff will be at the same level as your heart.
3. Apply the arm cuff to your upper arm.
• The cuff blue strip should be at the center of your inner arm, so that the air
tube is in line with your middle finger.
Blue Strip
1 - 2 cm
Air Tube
4. Secure the cuff around your arm using the velcro strip.