Omron H5CR, H5CR-S, H5CR-B, H5CR-L, H5CR-SS User Manual

...
Multifunction Digital Timer H5CR
1/16 DIN Timer with Easy-to-Use Functions
Nine field-selectable output modes accommodate a wide variety of applications
All parameters set by scroll­ through menus accessed from the front panel
Field-selectable time ranges from
0.001 second to 9999 hours
High-visibility alphanumeric LCD display has 8 mm high characters and built-in backlight
Precision control possible to
0.001 second
Four levels of key protection provided
10-year battery back-up
Selectable elapsed time (UP)
and time remaining (DOWN) display
Short body model H5CR-S measures just 64 mm (2.52 inches) deep
Ordering Information
TIMERS
Add the supply voltage to the part number when you order. For example, H5CR-B-AC100-240.
Timing functions 9 selectable, including ON-delay, repeat cycle, OFF-delay, and one-shot Contact type SPDT relay Solid-state open collector Product type Economy Standard Short body Economy Standard Short body Unit depth 78 mm 100 mm 64 mm 78 mm 100 mm 64 mm
(3.07 in) (3.94 in) (2.52 in) (3.07 in) (3.94 in) (2.52 in) Panel mounting hardware Not provided Provided Provided Not provided Provided Provided Supply AC 24 V or 100 to 240 V; 50/60 Hz — 24 V or 100 to 240 V; 50/60 Hz — voltage DC 12 to 24 V 12 to 24 V 12 to 24 V 12 to 24 V
ACCESSORIES
Description Part number Soft cover with two mounting clips for front panel protection Y92A-48F1 Shock prevention terminal cover for Standard and Short body timers protects wiring connections Y92A-48T Sockets for Bottom surface or track mounting, top screw terminals P2CF-08 economy timers Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminals P3G-08
H5CR 1
H5CR H5CR
REPLACEMENT PARTS
Description Part number Panel mounting bracket (one supplied with H5CR-B and H5CR-S models) Y92F-30
RANGE AND OPERATION MODE SELECTION
Range selection Time unit Maximum setting
- . - - - s 0.001 second 9.999 seconds
- - . - - s 0.01 second 99.99 seconds
- - - . - s 0.1 second 999.9 seconds
- - - - s 1 second 9999 seconds
- - min - - s 1 second 99 minutes 59 seconds
- - - . - min 0.1 minute 999.9 minutes
- - - - min 1 minute 9999 minutes
- - hr - - min 1 minute 99 hours 59 minutes
- - - . - hr 0.1 hour 999.9 hours
- - - - hr 1 hour 9999 hours
Mode Operation Output type A ON-delay Sustained or A-1 Sustained start signal ON-delay one-shot* A-2 Power ON-delay A-3 Power ON-delay/non-power
resettable B Repeat cycle B-1 Repeat cycle/non-power
resettable D OFF-delay Sustained E One-shot F Cumulative signal ON-delay
*One-shot time, seven choices selectable:
0.1 sec, 0.5 sec, 1 sec, 5 sec, 10 sec, 15 sec, 20 sec
Specifications
Part number H5CR-L H5CR-B H5CR-S Classification Economy type Standard type Short body type Supply
voltage
Operating voltage 85% to 110% of rated voltage Power
consumption Inputs Types available Reset and start signal Reset, gate, start signal, and key protect
Signal, Type No-voltage input reset ON impedance 1 k max. (Approx. 2 mA when 0) and gate Residual voltage 2 V max. in ON state
Key Type No-voltage input protect ON impedance 100 k max. (Approx. 2 mA when 0)
Control output
Repeat accuracy Power start ±0.01%, ±0.05 second max.
Setting error — Resetting system Power reset (A, A-1, A-2, B, D and E modes)
Resetting time Power reset 0.5 second minimum (A, A-1, A-2, B, D and E modes) Indicators 4-digit LCD alphanumeric 4-digit LCD alphanumeric display with backlighting
Type Time limit SPDT relay output or NPN open collector transistor output (H5CR-S)
Relay Max. load 5 A, 250 VAC resistive load (p.f. = 1)
Solid- Max. load 100 mA, 30 VDC state Residual voltage 2 V max., 1 V typical
2
AC 100 to 240 VAC, 50/60 Hz, 100 to 240 VAC, 50/60 Hz,
24 VAC, 50/60 Hz 24 VAC, 50/60 Hz
DC 12 to 24 VDC, 20% max. 12 to 24 VDC, 20% max.
permissible ripple permissible ripple
AC 3 VA at 60 Hz, 240 VAC — DC 1 W at 24 VDC 2 W at 24 VDC
OFF impedance 100 k minimum Pulse width 1 ms or 20 ms selectable for reset and signal
20 ms for gate
Residual voltage 1 V max. in ON state OFF impedance 100 k minimum Response time 1 second
Instantaneous
Min. load 10 mA, 5 VDC
Signal start ±0.005%, ±0.03 second max. (rate for set value)
External, manual, automatic resets (may be internal depending on A-1, B, B-1, D and E operation modes)
display without backlighting 8 mm (0.32 in) H present value, 4 mm (0.16 in) H set value 8 mm (0.32 in) H present value, 4 mm (0.16 in) H set value
H5CR H5CR
SPECIFICATIONS continued
Memory function Retains preset values for 10 years at 25° C (77° F) Materials Plastic case Mounting Panel or surface; Y92F-30 Panel, Y92F-30 mounting bracket included
Connections 8-pin round socket Screw terminals Weight 105 g (3.7 oz.) 160 g (5.6 oz.) 120 g (4.2 oz.) Approvals UL/CSA/SEV Operating ambient temperature -10° to 55°C (14° to 131°F) with no icing Humidity 35% to 85% RH Vibration Mechanical durability 10 to 55 Hz with 0.75 mm single amplitude in 3 directions
Malfunction durability 10 to 55 Hz with 0.5 mm single amplitude in 3 directions
Shock Mechanical durability 30 G each in three directions
Malfunction durability 10 G each in three directions Variation due to voltage change Included in "Repeat accuracy" specification Variation due to temperature change Included in "Repeat accuracy" specification Insulation resistance 100 MΩ min. at 500 VDC between current-carrying terminal and exposed non-current-
Dielectric strength 2,000 VAC, 50/60 Hz for 1 minute between current-carrying terminal and exposed
Service life Mechanical 10 million operations minimum (SPDT relay) Electrical 100,000 operations minimum at 5 A, 240 VAC, resistive load (p.f. = 1)
mounting bracket included
carrying metal parts, and between non-continuous contacts.
non-current-carrying metal parts for 100 to 240 VAC type 1,000 VAC for both 24 VAC and 12 to 24 VDC types
Timing Charts
OPERATION MODES
The gate input is not included on "economy" models H5CR-L and H5CR-LS.
Output mode A: Signal ON delay 1 (Timer resets when power comes on.)
Power
Start signal
Gate
Reset
Control output
Set value
Timing diagram
Output mode A1: Signal ON delay 2 (Timer resets when power comes on.)
Timing diagram
UP 0
Set value
DOWN 0
Power
Start signal
Gate
Reset
Control output
Set value
UP 0
Set value
DOWN 0
Timing begins at the leading edge of the start signal. The control output will be energized when the present value equals the preset time. The output will be sustained until a reset signal is applied, until power is interrupted, or for a programmable one-shot time period.
Timing begins at the leading edge of the start signal. The control output will be energized if the start signal is sustained for an amount of time equal to the preset time. The output will be sustained until the start signal is interrupted, until a reset signal is applied, until power is interrupted, or for a programmable one­shot time period.
One-shot
Sustained output
One-shot outputs can be set to 0.1 s, 0.5 s, 1 s, 5 s, 10 s, and 20 s.
3
H5CR H5CR
Output mode A-2: Power ON delay 1 (Timer resets when power comes on.)
Power
Start signal
Gate
Reset
Control output
Set value
Timing diagram
Output mode A-3: Power ON delay 2 (Timer does not reset when power comes on.)
Timing diagram
UP 0
Set value
DOWN 0
Power
Start signal
Gate
Reset
Control output
Set value
UP 0
Set value
DOWN 0
Timing begins when power is applied. Start signals act as a gate input, causing the present value to hold. The control output will be energized when the present value equals the preset time. The output will be sustained until a reset signal is applied, until power is interrupted, or for a programmable one-shot time period.
Timing begins when power is applied. Start signals act as a gate input, causing the present value to hold. The control output will be energized when the present value equals the preset time. The output will be sustained until a reset signal is applied or for a programmable one-shot time period. If power to the unit is interrupted, the control output will be de-energized. The output will re­energize once power is restored.
Output mode B: Repeat cycle 1 (Timer resets when power comes on.)
Power
Start signal
Gate
Reset
Control output
Set value Timing diagram
Timing diagram
UP 0
Set value
DOWN 0
Power
Start signal
Gate
Reset
Control output
Set value
UP 0
Set value
DOWN 0
One-shot Sustained output
One-shot outputs can be set to 0.1 s, 0.5 s, 1 s, 5 s, 10 s, and 20 s.
a = one-shot time before power interruption t-a = remaining one-shot time after power interruption
The OFF/ON cycle is initiated at the leading edge of the start signal. The output relay will be OFF for the preset time, then ON for the preset time. The cycle will be repeated until a reset input is applied or power is interrupted.
The OFF/ON cycle is initiated at the leading edge of the start signal. The control output will be OFF for the first cycle. In subsequent cycles the output will be ON for the programmable one­shot time period, then OFF for the remainder of the preset time. The cycle will be repeated until a reset input is applied or power is interrupted.
4