Power PCB Relay
G2R
• Creepage distance of 8.0 mm (0.31) min. between coil and
contact.
• Dual-winding latching type available.
• Plug-in and quick-connect terminals available.
• High sensitivity (360 mW) and high capacity (16 A) types
available.
• Highly stable magnetic circuit for latching endurance and
excellent resistance to vibration and shock.
• Safety-oriented design assuring high surge resistance:
10,000 V min. between coil and contacts.
• UL, CSA approved, marked with CE.
Ordering Information
To order: Select the part number and add the desired coil voltage rating (e.g., G2R-14-DC12).
■ Non-Latching
1-Pole - PCB Types
Type Contact material Contact form Construction Model
General purpose AgCdO SPDT Semi-sealed G2R-1
Sealed G2R-14
SPST-NO Semi-sealed G2R-1A
Sealed G2R-1A4
High-capacity SPDT Semi-sealed G2R-1-E
SPST-NO G2R-1A-E
High-sensitivity SPDT G2R-1-H
Sealed G2R-14-H
SPST-NO Semi-sealed G2R-1A-H
Sealed G2R-1A4-H
1-Pole - Plug-in/Quick-connect Types
Type Contact material Contact form Terminal Model
General purpose AgCdO SPDT Plug-in G2R-1-S
LED indicator G2R-1-SN
Surge suppression diode G2R-1-SD
LED indicator and surge suppression diode G2R-1-SND
Upper-mount bracket SPDT Quick connect G2R-1-T
SPST-NO G2R-1A-T
Note: 1. AgInSn and gold plated contacts available.
2. Bifurcated button available.
3. For individual product agency approvals consult factory.
4. Class B coil insulation available.
5. Push to test button available on plug-in type. Consult Omron for details.
6. CE mark only on plug-in and quick connect types (G2R--S).
1 Power PCB Relay G2R
2-Pole - PCB Types
Type Contact material Contact form Construction Model
General purpose AgCdO DPDT Semi-sealed G2R-2
Sealed G2R-24
DPST-NO Semi-sealed G2R-2A
Sealed G2R-2A4
High sensitivity DPDT Semi-sealed G2R-2-H
Sealed G2R-24-H
DPST-NO Semi-sealed G2R-2A-H
Sealed G2R-2A4-H
2 Pole - Plug-in/Quick-connect Types
Type Contact material Contact form Terminal Model
General purpose AgCdO DPDT Plug-in G2R-2-S
LED indicator G2R-2-SN
Surge suppression diode G2R-2-SD
Led indicator and surge suppression diode G2R-2-SND
Note: 1. AgInSn and gold plated contacts available.
2. Bifurcated button available.
3. For individual product agency approvals consult factory.
4. Class B coil insulation available.
5. Push to test button available on plug-in type. Consult Omron for details.
■ Latching
Type Contact form Construction Model
Dual coil latching SPDT Semi-sealed G2RK-1
SPST-NO G2RK-1A
DPDT G2RK-2
DPST-NO G2RK-2A
■ Accessories
Track Mounted Sockets/Track
Relay Model
Socket Mounting track
G2R-1-S (1-pole) P2RF-05 PFP-100N or
P2RF-05-E
G2R-2-S (2-pole) P2RF-08
P2RF-08-E
Note: “-E” models are of finger-safe product construction. Round terminals cannot be used. Use Y-shaped terminals.
Screwless Clamp Terminal Socket Ordering Information
1-pole 2-pole
Socket P2RF-05-S P2RF-08-S
Clip & release lever P2CM-S
Nameplate R99-11 nameplate for MY
Socket bridge P2RM-SR, P2RM-SB
Note: For complete specifications see the data sheet at Omron’s Knowledge center at www.knowledge.omron.com.
PFP-50N and
PFP-M end plate
PFP-S (optional spacer)
Power PCB Relay G2R 2
Back Connecting Sockets/Plate
Relay Terminal Model
Socket Socket mounting plate
G2R-1-S (1-pole) Solder P2R-05-A P2R-P
PC P2R-05P
G2R-2-S (2-pole) Solder P2R-08A
PC P2R-08P
Specifications
■ Contact Data
Non-latching general purpose, plug-in, plug-in operation indicator self-contained, plug-in diode self-contained and
upper-mount bracket.
1-pole type 2-pole type
Load
Rated load 10 A at 250 VAC
Contact material AgCdO
Carry current 10 A 5 A
Max. operating voltage 380 VAC, 125 VDC
Max. operating current 10 A 5 A
Max. switching capacity 2,500 VA, 300 W 1,875 VA, 150 W 1,250 VA, 150 W 500 VA, 90 W
Min permissible load 100 mA, 5 VDC 10 mA, 5 VDC
Resistive load
(p.f. = 1)
10 A at 30 VDC
Inductive load
(p.f. = 0.4) (L/R = 7 ms)
7.5 A at 250 VAC
5 A at 30 VDC
Resistive load
(p.f. = 1)
5 A at 250 VAC
5 A at 30 VDC
Inductive load
(p.f. = 0.4) (L/R = 7 ms)
2 A at 250 VAC
3 A at 30 VDC
Non-latching high capacity 1-pole type
Load
Rated load 16 A at 250 VAC
Contact material AgCdO
Carry current 16 A
Max. operating voltage 380 VAC, 125 VDC
Max. operating current 16 A
Max. switching capacity 4,000 VA, 480 W 2,000 VA, 240 W
Min. permissible load 100 mA, 5 VDC
Resistive load
(p.f. = 1)
16 A at 30 VDC
8 A at 250 VAC
8 A at 30 VDC
Inductive load
(p.f. = 0.4) (L/R = 7 ms)
Non-latching high-sensitivity
1-pole type 2-pole type
Load
Rated load 5 A at 250 VAC
Contact material AgCdO
Carry current 5 A 3 A
Max. operating voltage 380 VAC, 125 VDC
Max. operating current 5 A 3 A
Max. switching capacity 1,250 VA, 150 W 500 VA, 90 W 750 VA, 90 W 250 VA, 45 W
Min permissible load 100 mA, 5 VDC 10 mA, 5 VDC
Resistive load
(p.f. = 1)
5 A at 30 VDC
Inductive load
(p.f. = 0.4) (L/R = 7 ms)
2 A at 250 VAC
3 A at 30 VDC
Resistive load
(p.f. = 1)
3 A at 250 VAC
3 A at 30 VDC
Inductive load
(p.f. = 0.4) (L/R = 7 ms)
1 A at 250 VAC
1.50 A at 30 VDC
3 Power PCB Relay G2R
Latching
1-pole type 2-pole type
Load
Rated load 5 A at 250 VAC
Contact material AgCdO
Carry current 5 A 3 A
Max. operating voltage 380 VAC, 125 VDC
Max. operating current 5 A 3 A
Max. switching capacity 1,250 VA, 150 W 875 VA, 75 W 750 VA, 90 W 375 VA, 60 W
Min permissible load 100 mA, 5 VDC 10 mA, 5 VDC
Resistive load
(p.f. = 1)
5 A at 30 VDC
Inductive load
(p.f. = 0.4) (L/R = 7 ms)
3.50 A at 250 VAC
2.50 A at 30 VDC
Resistive load
(p.f. = 1)
3 A at 250 VAC
3 A at 30 VDC
Inductive load
(p.f. = 0.4) (L/R = 7 ms)
1.50 A at 250 VAC
2 A at 30 VDC
Note: 1. P standard: λ
2. AgInSn contacts available.
3. For individual product agency approvals consult factory.
= 0.10 x 10-6 operation.
50
■ Coil Data
Non-latching DC coil
Rated voltage
(VDC)
3 176 17 0.07 0.14 70% max. 15% min. 110% max.
5 106 47 0.20 0.39
6 88.20 68 0.28 0.55
12 43.60 275 1.15 2.29
24 21.80 1,100 4.27 8.55
48 11.50 4,170 13.86 22.71
100 5.30 18,860 67.20 93.20
110 4.80 22,900 81.50 110.60
Rated current
(mA)
Coil
resistance
(Ω)
Coil inductance
(ref. value) (H)
Armature
OFF
Armature
ON
Non-latching AC coil
Rated voltage
(VDC)
6 150 16 0.05 0.10 80% max. 30% min. 110% max.
12 75 65 0.19 0.39
24 37.50 260 0.81 1.55
50 18 1,130 3.25 6.73
110 10.60 4,600 13.34 26.84
120 7.50 6,500 21 42
220 5.30 22,000 51.30 102
240 3.80 30,000 65.50 131
Rated current
(mA)
Coil
resistance
(Ω)
Coil inductance
(ref. value) (H)
Armature
OFF
Armature
ON
Pick-up
voltage
Pick-up
voltage
Dropout
voltage
% of rated voltage
Dropout
voltage
% of rated voltage
Maximum
voltage
at 70°C
(158°F)
Maximum
voltage
at 70°C
(158°F)
Powe r
consumption
(mW)
Approx. 530
Powe r
consumption
(mW)
Approx. 0.9
Non-latching high-sensitivity DC coil
Rated voltage
(VDC)
3 120 25 0.13 0.26 70% max. 15% min. 110% max.
5 71.40 70 0.37 0.75
6 60 100 0.63 1.07
12 30 400 2.14 4.27
24 15 1,600 7.80 15.60
48 7.50 6,400 31.20 62.40
Rated current
(mA)
Coil
resistance
(Ω)
Coil inductance
(ref. value) (H)
Armature
OFF
Armature
ON
Pick-up
voltage
Dropout
voltage
% of rated voltage
Maximum
voltage
at 70°C
(158°F)
Power PCB Relay G2R 4
Powe r
consumption
(mW)
Approx. 360
Latching dual coil type - Set coil
Coil inductance
(ref. value) (H)
Armature
OFF
Armature
ON
Rated voltage
(VDC)
Rated current
(mA)
Coil
resistance
(Ω)
3 227 10.80 0.026 0.052 70% max. 70% max. 110% max.
5 167 30 0.073 0.146
6 138 43.50 0.104 0.208
12 70.60 170 0.42 0.83
24 34.60 694 1.74 3.43
Pick-up
voltage
Dropout
voltage
% of rated voltage
Maximum
voltage
at 70°C
(158°F)
Latching dual coil type - Reset coil
Coil inductance
(ref. value) (H)
Armature
OFF
Armature
ON
Rated voltage
(VDC)
Rated current
(mA)
Coil
resistance
(Ω)
3 200 15 0.001 0.002 70% max. 70% max. 110% max.
5 119 42 0.003 0.006
6 100 60 0.005 0.009
12 50 240 0.018 0.036
24 25 960 0.079 0.148
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C (73°F).
Pick-up
voltage
Dropout
voltage
% of rated voltage
Maximum
voltage
at 70°C
(158°F)
■ Characteristics
Power
consumption
(mW)
Approx. 850
Power
consumption
(mW)
Approx. 600
Item Non-latching Latching
Contact resistance 100 mΩ
Operate (set) time 15 ms. max. 20 ms max.
Release (reset) time AC: 10 ms max.; DC: 5 ms max. 20 ms max.
Bounce time Operate --- Mean value approx. 3 ms
Release --- Mean value approx. 8 ms
Operating frequency Mechanical 18,000 operations/hour
Electrical 1,800 operations/hour (under rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 5,000 VAC, 50/60 Hz for 1 minute between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute across contacts of same pole
3,000 VAC, 50/60 Hz for 1 minute between contact sets, 2-pole non-latching
1,000 VAC, 50/60 Hz for 1 minute between set and reset coils of dual coil latching
Vibration Mechanical durability 10 to 55 Hz; 1.50 mm (0.06) double amplitude
Malfunction durability 10 to 55 Hz; 1.50 mm (0.06) double amplitude
Shock Mechanical durability
Malfunction durability
1,000 m/s
200 m/s
100 m/s
2
(approx. 100G)
2
(approx. 20 G) when energized
2
(approx. 10 G) when de-energized
500 m/s
100 m/s
2
(approx. 50 G) at set
2
(approx. 10 G) at reset
Ambient temperature -40 to 70°C (-40 to 158°F)
Humidity 35% to 85% RH
Service life Mechanical AC: 10,000,000 operations min.
DC: 20,000,000 operations min.
10,000,000 operations min.
(at 18,000 operations/hour)
(at 18,000 operations/hour)
Electrical See “Characteristics Data”
Weight Approx. 17 g (0.60 oz.) Approx. 17 g (0.60 oz.)
Note: Data shown are of initial value.
5 Power PCB Relay G2R
■ Characteristic Data
Maximum Switching Capacity - Non-latching Types
PCB: Single-pole general purpose
Semi-sealed
Plug-in: Single-pole single button
Quick-connect
High capacity
PCB: Single-pole high sensitivity
Two-pole general purpose
Plug-in: Two-pole single button
Rated operating current (A)
Rated operating voltage (V)
PCB: Two-pole high sensitivity
Rated operating current (A)
Rated operating voltage (V)
PCB: Single-pole general purpose
Sealed
Rated operating current (A)
Rated operating voltage (V)
Rated operating current (A)
Rated operating voltage (V)
Electrical Service Life - Non-latching Types
PCB: Single-pole general purpose
Semi-sealed
Plug-in: Single-pole single button
Quick connect
High capacity
Rated operating current (A)
Rated operating voltage (V)
PCB: Two-pole general purpose
Sealed
Rated operating current (A)
Rated operating voltage (V)
PCB: Single-pole high sensitivity
Two-pole general purpose
Plug-in: Two-pole single button
operations)
4
Service life (x 10
Rated operating current (A)
operations)
4
Service life (x 10
Rated operating current (A)
operations)
4
Service life (x 10
Rated operating current (A)
Power PCB Relay G2R 6