Omron E5ZE-8AAAMTC-E, E5ZE-8AAAMP-E, E5ZE-8VAAMTC-E, E5ZE-8VAAMP-E, E5ZE-8AAAMTCB-E Datasheet

...
Multipoint Temperature Controller E5ZE 1
Multipoint Temperature Controller
E5ZE
Compact, Easy-to-mount Multipoint Temperature Controller (Casing)
Compact, Easy-to-use, Board-type Multipoint Temperature Controller (Open)
• 50% small er in projection space than the previous E5ZD Multi­point Temper a ture Cont roll er.
• Connector terminal block saves wiring effort.
• High-speed input sampling.
• Heating/cooling model s are a vailable.
Note: Open models do not bear CE markings.
Model Number Structure
Model Number Legend
1. Control Point
8: 8
2. Control Method
A: Standard V: Heating/cooling
3. Control Output
A: Option (see note 1)
4. Heater Burnout and SSR Failure Detection (see note 2)
A: Option (see note 3)
5. Communications
M: Option (see note 4)
6. Input Type
TC: Thermocouple P: Platinum resistance thermometer
7. Casing
B: Yes Blank:No (open type)
Note: 1. The E53-E8Q Voltage Output Unit or the E53-E8C Current
Output Unit can be used with the E5ZE. The E53-E8Q Volt­age Output Unit and the E53-E8C Current Output Unit are sold separately.
2. The heater burnout and SSR failure detection function of the E5ZE will be invalid if the heating side control output of the E5ZE is current output.
3. The E54-E8CT CT Input Unit is required for the heater burn­out and SSR failure detection. The E54-E8CT CT Input Unit is sold separately .
4. The E53-E01 Communications Unit for RS-232C communi­cation or the E53-E04 Communications Unit for RS-422 and RS-485 communication can be used with the E5ZE. The E53-E01 Communications Unit and the E53-E04 Communi­cations Unit are sold separately.
E5ZE-8@AAM@@-E
1 2 3 4 5 6 7
2 Multipoint Temperature Controller E5ZE
Ordering Information
List of Models
I/O Units (Order Separately)
Accessories (Order Separately)
Current Transformers (CT)
Note: The above CTs are not provided with the E5ZE.
Recommended Power Supply
S82J Switching Power Supply
S82K Switching Power Supply
Wiring Devices
Connector Terminal Conversion Unit
No. of
control
points
Casing Control
method
Control
output
Heater burnout
and SSR failure
detection
Communica-
tions
Input type
Thermocouple Platinum resistance
thermometer
8 No Standard Option Option Option E5ZE-8AAAMTC-E E5ZE-8AAAMP-E
Heating and cooling
Option Option Option E5ZE-8VAAMTC-E E5ZE-8VAAMP-E
Yes Standard Option Option Option E5ZE-8AAAMTCB-E E5ZE-8AAAMPB-E
Heating and cooling
Option Option Option E5ZE-8VAAMTCB-E E5ZE-8VAAMPB-E
Units Models
RS-232C Communications Unit E53-E01 RS-422/485 Communications Unit E53-E04 CT Input Unit E54-E8CT Voltage Output Unit E53-E8Q Current Output Unit E53-E8C
Hole diameter 5.8 mm 12.0 mm Model E54-CT1 E54-CT3
Input volta ge Power ra tings Output voltage Output current Model
Open-frame type Covered-type
100 to 240 VAC 50 W 24 V 2.1 A S82J-05024A S82J-05024D
100 W 4.5 A S82J-10024A S82J-10024D 150 W 6.5 A S82J-15024A
S82J-15024B S82J-15024C
S82J-15024D S82J-15024E S82J-15024F
Input volta ge Power ra tings Output voltage Output current Model
100/200 VAC 50 W 24 V 2.1 A S82K-05024
100 W 4.2 A S82K-10024
Specifications Model
20-pole, M2.4 terminal block XW2B-20G4 20-pole, M3.5 terminal block XW2B-20G5
Multipoint Temperature Controller E5ZE 3
I/O Block
Connecting Cable
Setting Display Unit
Note: 1. The Setting Display Unit is originally for use with the E5ZD . Be careful when using the Setting Display Unit with the E5ZE as some of the
E5ZE’s functions cannot be used with the Setting Display Unit.
2. Each model available as a 100-to-240-VAC type or 24-VDC type. (Exception: The E5ZD-SDLM is available only as a 24-VDC type).
Specifications Model
8-point (SPST-NO x 8) relay output with NPN DC coil (+ common) G7TC-OC08 16-point (SPST-NO x 16) relay output with NPN DC coil (+ common) G7TC-OC16 16-point (SPST-NO x 16) relay output with NPN DC coil (+ common) G7VC-OC16 16-point (SPST-NO x 16) SSR AC output with NPN DC coil (+ common) G7VC-OA16 16-point (SPST-NO x 16) SSR DC output with NPN DC coil (+ common) G7VC-OD16
Specifications Model
2 m long E5ZE-CBL200
Connecting model Connecting part Model (see note 2)
RS-232C Connector E5ZD-SDL1 RS-422 Terminal block E5ZD-SDL2-X RS-485 Terminal block E5ZD-SDL3-X
E5ZD-SDLM
4 Multipoint Temperature Controller E5ZE
Specifications
Ratings
Supply voltage 24 VDC Operating voltage range 85% to 110% of rated supply voltage Power consumption 15 W + 20% max. at rated supply voltage Input Input type Thermocouple: K, J, R, S, T, E, B, N, L, U, W , PL-II
Platinum resistance thermometer: Pt100, JPt100
Input impedance Thermocouple: 1 M
min.
Rated platinum resistance thermometer current
1 mA
Control outputs Voltage output (with short-circuit protecting function)
ON: 12
± 1.2 VDC
OFF: 0.5 VDC max. Max. load current: 30 mA DC per point
Current output
Rated output range: 4 to 20 mA DC Current output range: 0 to 22 mA DC
With an output value of 0%: 4
+0
/
–0.6
mA DC
With an output value of 100%:20
+2
/–0 mA DC
Max. load resistance: 600
per point
Open collector output (NPN) (cooling side only)
Max. applied voltage: 30 VDC Max. load current: 50 mA DC per point ON residual voltage: 2 VDC max. OFF leakage current: 1 mA DC max.
Alarm outputs Te mperature alar m: The total output of all control points (alarm 1 NPN open collector output and
alarm 2 NPN open collector output)
HB alarm (heater burnout detection): Total output of all control points (1-point NPN open collector
output)
HS alarm (SSR failure detection): Total output of all control points (1-point NPN open collector
output)
Temperature controller error output (memory, set value, or hardware error): 1-point NPN open collector output
Max. applied voltage: 30 VDC Max. load current: 50 mA DC per point
No. of input c on t rol points 8 input and 8 control points Setting method Via communication Control method ON/OFF control
Hybrid of 2-PID control and fuzzy control Manual operation
Multipoint Temperature Controller E5ZE 5
Input Ranges
Thermocouple
Platinum Resistance Thermometer
Note: 1. T he set ting selector set to 0 (K) or 0 (Pt 100) before shipping.
2. A temperature range is factory-set to a range of –200
° to 1,300°C (K(CA)) or 100.0° to 500.0°C (Pt 100).
3. Thermocouple W is W/Re5-26 (tungsten rhenium 5, tungsten rhenium 26).
Input (switch
selectable)
(see note 1)
K (CA)
Chromel vs.
alumel (see
note 2)
J (IC)/L
Iron vs.
constantan
R/S Platinum vs. Plati-
num rhod-
ium 10%
T (CC)/U
Copper vs.
constantan
E (CRC)
Chromel vs.
constantan
B
Platinum
rhodium
30% vs.
platinum
rhodium 6%
N
Nichrosil
vs. nisil
W
(see note 3)
PL-II
(Platinum)
Range
°C 200 to
1,300
100 to 850 0 to 1,700 200 to 400 0 to 600 100 to 1,800 0 to 1,300 0 to 2,300 0 to 1,300
°F 300 to
2,300
100 to
1,500
0 to 3,000 300 to 700 0 to 1,100 300 to 3,000 0 to 2,300 32 to 4,100 0 to 2,300
Setting no. 01/82/34/9567AB Min. setting unit 1
°C or 0.1°C
Input (switch
selectable)
(see note 1)
Pt 100 JPt 100
Range
°C 100.0 to 500.0 100.0 to 500.0 °F 100.0 to 900.0 100.0 to 900.0
Setting no. 01 Min. setting unit 1
°C or 0.1°C
6 Multipoint Temperature Controller E5ZE
Characteristics
Note: 1. The measurement accuracy of the E5ZE used with a ther mocouple B at 400°C or 750°F max. is not guaranteed. The following
measurement accuracy values are applied to the E5ZE. K and T at
100°C max. and U: ±3°C ±1 digit max.
K and T at
100°F max. and U: ±5.4°F ±1 digit max.
R, S, and W at 200
°C max., and B at 1,000°C max.: ±4°C ±1 digit max.
R, S, and W at 400
°F max., and B at 1,800°F m ax.: ±7.2°F ±1 digit max.
2. The measurement accuracy of the E5ZE used with any thermoc ouple is 1
°C/°F. The thermocouple can be used under the following
temperature ranges to increase the measurement accuracy to as high as 0.1
°C/°F.
K thermocouple: 0.0
°C to 1,300.0 °C, 0.0 °F to 2,300.0 °F
T or U thermocouple: 0.0
°C to 400.0 °C, 0.0 °F to 700.0 °F
N thermocouple: 400.0
°C to 1,300.0 °C, 700.0 °F to 2,300.0 °F
J, E, L, or PLII thermocouple: Any temperature
3. To ensure EMC conformance, refer to Wiring for Conformance to the EMC Directives on page 16.
Measurement accuracy (see note) Thermocouple:
(
±0.3% of the process value or ±2°C, whichever greater) ±1 digit max.
(
±0.3% of the process value or ±3.6°F, whichever greater) ±1 digit max.
Platinum resistance thermometer:
(
±0.3% of the process value or ±0.8°C, whichever greater) ±1 digit max.
(
±0.3% of the process value or ±1.5°F, whichever greater) ±1 digit max.
Hysteresis 0.0
°C/°F to 99.9°C/°F for ON/OFF control only (in units of 0.1°C/°F)
Cooling coefficient 0.0 to 10.0 (in units of 0.1) Proportional band 0.0
°C/°F to 999.9°C/°F (in units of 0.1°C/°F)
Cooling side: Cooling coefficient x Proportional band
Integral (reset) time 0 to 3,999 s (in units of 1 s) (for both heating and cooling) Derivative (rate) time 0 to 3,999 s (in units of 1 s) (for both heating and cooling) Control period Heating side:1 to 99 s (in units of 1 s)
Cooling side: 1 to 99 s (in units of 1 s)
Sampling period Approx. 200 ms for 8 control points Dead band/overlap band
999°C/°F to 999°C/°F (in units of 1°C/°F)
Alarm output setting range
999°C/°F to 9999°C/°F, 0 to 9999°C/°F (upper- and lower-limit alarm) (in units of 1°C/°F)
999.9°C/°F to 9999.9°C/°F, 0.0 to 9999.9°C/°F (upper- and lower-limit alarm) (in units of 0.1°C/°F)
Fuzzy strength 0% to 99% (in units of 1%) Fuzzy scale 1 0.2
°C/°F to 999.9°C/°F (in units of 0.1°C/°F)
Fuzzy scale 2 0.02
°C/s or °F/s to 99.99°C/s or °F/s (in units of 0.01°C/s or °F/s)
Set value backup Lithium battery Set value backup period 10 years min. at room temperature Insulation resistance 20 M
min. between the FG terminal and all analog input terminals (at 500 VDC)
Dielectric strength A leakage current of 1 mA A C max. with 500 V AC for 1 minutes between the FG terminal and all analog
input terminals
Vibration resistance
Malfunction: 10 to 55 Hz, 10 m/s
2
(1G) for 10 min each in X, Y, and Z directions
Destruction: 10 to 55 Hz, 20 m/s
2
(2G) for 2 hrs each in X, Y, and Z directions
Shock resistance
Malfunction: 150 m/s
2
(15.3G), 3 times each in 6 directions
Destruction: 200 m/s
2
(20.4G), 3 times each in 6 directions
Ambient temperature Operating:
10°C to 55°C (with no icing or condensation)
Storage:
25°C to 65°C (with no icing or condensation)
Ambient humidity Operating: 35% to 85%
Storage: 35% to 95%
Dimensions Without casing: 169.5 x 192 x 58 mm max.
With casing: 173.5 x 200 x 65 mm max.
Degree of protection IP00 Weight Without casing: 900 g max.
With casing: 1,700 g max.
EMC Em ission Enclos ure: EN55011 Group 1 class A
Immunity ESD: EN61000-4-2:4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference: ENV50140: 10 V/m (amplitude modulated, 80 MHz to 1 GHz)
(level 3)
10 V/m (pulse modulated, 900 MHz) Immunity Conducted Disturbance: ENV50141: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst: EN61000-4-4:2 kV power-line (level 3)
Approved standards Conforms to EN50081-2, EN50082-2 (see note 3)
Loading...
+ 14 hidden pages