E3X-MDA Super Dual Fiber Sensors 3
Specifications
■ Ratings/Characteristics
Amplifier Units
*1: When differential output is selected for the output setting, the second channel output is 200 µs for operation and reset respectively.
*2: Communications are disabled if the detection mode is selected during super-high-speed mode, and the communications functions for mutual
interference prevention and the Mobile Console will not function.
*3: Mutual interference prevention can be used for up to 5 Units (10 channels) if power tuning is enabled.
Type 2-channel models
Model NPN output E3X-MDA11 E3X-MDA6
Item PNP output E3X-MDA41 E3X-MDA8
Light source (wavelength) Red LED (635 nm)
Supply voltage 12 to 24 VDC
±10%, ripple (p-p) 10% max.
Power consumption 1,080 mW max.
(current consumption: 45 mA max. at power supply voltage of 24 VDC)
Control output Load power supply voltage: 26.4 VDC; open collector;
load current: 50 mA max.; residual voltage: 1 V max.
Circuit protection Reverse polarity for power supply connection, output short-circuit
Response
time
Superhighspeed
mode
NPN 130
µs
*1
for operation and reset respectively
PNP
Standard mode 1 ms for operation and reset respectively
High-resolution mode 4 ms for operation and reset respectively
Sensitivity setting Teaching or manual method
Functions Power tuning Light emission power and reception gain, digital control method
Timer function Select from OFF-delay, ON-delay, or one-shot timer.
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments,
200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments)
Automatic power control
(APC)
High-speed control method for emission current
Zero-reset Display can be reset to zero when required (negative values can be displayed).
Initial reset Settings can be returned to defaults as required.
Mutual interference
prevention
Possible for up to 9 Units (18 channels)
*2, *3
I/O settings Output setting (Select from channel 2 output, AND, OR, leading edge sync, falling edge sync, or differ-
ential output)
Display Operation indicator for channel 1 (orange), Operation indicator for channel 2 (orange)
Digital display Select from the following: Incident level for channel 1 + incident level for channel 2, Incident level +
threshold, incident level percentage + threshold, incident light peak level + no incident light bottom level,
minimum incident light peak level + maximum no incident light bottom level, long bar display, incident
level + peak hold, incident level + channel
Display orientation Switching between normal/reversed display is possible.
Ambient illumination
(receiver side)
Incandescent lamp: 10,000 lux max.
Sunlight: 20,000 lux max.
Ambient temperature Operating: Groups of 1 to 2 Amplifiers:
−25°C to 55°C
Groups of 3 to 10 Amplifiers:
−25°C to 50°C
Groups of 11 to 16 Amplifiers:
−25°C to 45°C
(with no icing or condensation)
Storage:
−30°C to 70°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Insulation resistance 20 M
Ω min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute
Vibration resistance (destruction) 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions
Shock resistance (destruction) 500 m/s
2
, for 3 times each in X, Y and Z directions
Enclosure rating IEC 60529 IP50 (with Protective Cover attached)
Connection method Prewired cable Standard connector
Weight (packed state) Approx. 100 g Approx. 55 g
Materials Case Polybutylene terephthalate (PBT)
Cover Polycarbonate (PC)
Accessories Instruction sheet