Digital Fiber Sensors
E3X-DA-S
High functionality digital fiber
amplifier
• High functionality digital fiber amplifier with advanced timing,
LED power control and signal processing functionality
providing highest detection accuracy and stability even for the
most challenging objects and settings.
• Power tuning function to adjust the received light to a
maximum, minimum or pre-defined value
• Auto power and threshold adjustment functions for highest
operational stability
• Two outputs for window monitoring
or two level detections (e.g. object + object state change)
Ordering information
Function Order code
Item
Pre-wired Yes Yes Yes Yes Yes Yes Yes Yes E3X-DA21-S 2M E3X-DA51-S 2M
Fiber amplifier
connector
M8 connector
*1.
*2.
*1
3 pin Yes Yes
4 pin E3X-DA14-S E3X-DA44-S
Order fiber amplifier connector E3X-CN_ separately
For fiber amplifiers with these functions and connecting with M8 connector, order the fiber amplifier connector models above and the
pigtail connector E3X-CN21-M3J-2 with 30cm PVC cable and M8 plug.
Power
Timer
tuning
Yes Yes Yes Yes - selectable Yes Yes Yes E3X-DA7-S E3X-DA9-S
Auto-
threshold
compensa-
tion (ATC)
Twin out-
put
External
input
Diffe-
rential
operation
*2
Wet
process
'tough
mode’
Power
saving 'Eco'
functions
(display/
LED off)
NPN PNP
E3X-DA13-S E3X-DA43-S
Fiber amplifier connectors
Shape Type Comment Order code
Fiber amplifier
connector
2 m PVC cable E3X-CN21
30 cm PVC cable with M12 plug connector (4 pin) E3X-CN21-M1J 0.3M
30 cm PVC cable with M8 plug connector (4 pin) E3X-CN21-M3J-2 0.3M
Mounting Bracket End Plate
Appearance Model Quantity
E39-L143 1
Appearance Model Quantity
PFP-M 1
1E3X-DA-S
Features
Power tuning
Timer functions
ON delay OFF delay One-shot ON delay and OFF delay
Incident light
No incident light
L-ON
D-ON
ON
OFF
ON
OFF
T
T
Adjust the output signal length and timing
n outpu
ent light
No incident light
ON
L-ON
OFF
ON
D-ON
OFF
Increase or decrease the LED
power and received light intensity
to the desired level e.g. a predefined value.
ent light
T
T
No incident light
ON
L-ON
OFF
ON
D-ON
OFF
T
T
ent light
No incident light
ON
L-ON
OFF
ON
D-ON
OFF
T1: ON-delay set time
T2
T1
T
2
T
: OFF-delay set time
2
T
and T2 can be set
1
T1
separately.
erential detection
Output 1: ON
Output 2: OFF
The two outputs can be used to detect two different light levels
Active-threshold control (ATC)
Without ATC: malfunction caused by
temperature drift, pollution or condensation
Output V Received light
Sensor output
Output 1: ON
Output 2: ON
Operation with ATC
Operation without ATC
T/ms
Threshold
without ATC
Incident level
ATC threshold
Triggering on single or double signal edges
Higher signal stability compensating for
power reduction caused by temperature drift,
dust or condensation.
2
Specifications
Item
Light source
Red LED (650 nm) Red LED (625 nm)
Pre-wired models Fiber amplifier connector models M8 connector models
E3X-DA_ 1-S E3X-DA7-S, E3X-DA9-S E3X-DA_ 3-S, E3X-DA_ 4-S
(wave length)
Power supply
voltage
Protective circuits
Super-high-speed
*2
mode
12 to 24 VDC ± 10%; ripple (p-p): 10% max
Reverse polarity protection, output short circuit protection, mutual interference prevention
*1
80 µs for operation and reset max. 55 µs for operation and reset max.
Standard mode 1 ms for operation and reset
High
resolution mode
Wet process
Response time
'tough mode'
4 ms for operation and reset
16 ms for operation and reset
*3
Sensitivity setting Teaching and digital up/down keys
Power tuning Light emission power and reception gain, digital control method
Timer OFF-delay, ON-delay, one-shot timer. 1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms incre-
ments, 200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments)
Auto power
control (APC)
Active-threshold
control (ATC)
Twin
output
External
Functions
input
LED power monitoring and auto-control function by LED emission current adjustment.
Monitoring of received light average and deviation adjustment of
threshold for output 1
Output 1: incident level
Output 2: incident level or alarm output
External teach or function trigger (power tuning, emitter OFF, ATC start)
Output 1: incident level
Output 2: incident level or alarm output
(not available if external input is used)
External teach or function trigger (power tuning, emitter OFF, ATC start) (not
*3
*3
*3
available if output 2 is used)
Differential operation
Wet process
'tough mode'
Power saving
'Eco' functions
Single edge or double edge detection mode
Incident level triggering on floating average of received light.
LED: ON/OFF switchable (external input)
Display: ON/ DIM / OFF selectable (Eco mode
*4
)
*3
*3
*3
Digital display Incident level + threshold or user specific
*1.
The reverse polarity protection for the pre-wired and fiber amplifier connector models is for the power supply and the output. For M8 connector models the reverse
polarity protection is for the power supply.
*2.
The communication function and mutual interference prevention function are disabled if detection is set to Super-high-speed Mode.
*3.
For fiber amplifiers with these functions and connecting with M8 connector, order the fiber amplifier connector models above and the
pigtail connector E3X-CN21-M3J-2 with 30 cm PVC cable and M8 plug.
*4.
When the ECO Mode is enabled, the rated sensing distance is approx. 1/2 and the incident level is approx. 1/3 of the normal levels.
Input Specifications
Contact input (relay or switch) Non-contact input (transistor)
NPN ON: Shorted to 0 V (sourcing current: 1 mA max.).
PNP ON: Shorted to Vcc (sinking current: 3 mA max.).
OFF: Open or shorted to Vcc.
OFF: Open or shorted to 0 V.
ON: 1.5 V max. (sourcing current: 1 mA max.)
OFF: Vcc - 1.5 V to Vcc (leakage current: 0.1 mA max.)
ON: Vcc - 1.5 V to Vcc (sinking current: 3 mA max.)
OFF: 1.5 V max. (leakage current: 0.1 mA max.)
Amplifier unit connectors
E3X-CN21_
Rated current 2.5 A
Rated voltage 50 V
Contact resistance 20 mΩ max. (20 mVDC max., 100 mA max.) (The figure is for connection to the amplifier unit and the adjacent con-
No. of insertions Destruction: 50 times (The figure for the number of insertions is for connection to the amplifier unit and the adjacent
Mate-
Housing Polybutylene terephthalate (PBT)
rials
Contacts Phosphor bronze/gold-plated nickel
Weight (packed state) Approx. 55 g
nector. It does not include the conductor resistance of the cable.)
connector.)
3E3X-DA-S
Exemplary sensing distances
(measured with E3X-DA51-S 2M)
*1
(Unit: mm)
Type Tough Mode
E32-T11N/
E32-TC200BR(B4R)
E32-T14LR/E32-T15YR/
E32-T15ZR
E32-T21R/E32-T22R/
E32-T222R/
E32-TC200FR(F4R)
E32-T24R 170 120 100 50 20
E32-TC200/E32-T12/
E32-T15X/E32-TC200B(B4)
E32-T14L/E32-T15Y/
Through-beam
*1.
The sensing distances with M8 connector models E3X-DA[]3-S and E3X-DA@4-S are approximately 50% of the exemplary values measured with E3X-DA51-S.
E32-T15Z
E32-TC200A 2,500 1,800 1,350 900 360
E32-TC200E/E32-T22/
E32-T222/
E32-TC200F(F4)
E32-T24 450 300 250 150 60
E32-T11/E32-T12B/
E32-T15XB
E32-T21/E32-T221B/
E32-T22B
E32-T11U 2,500 1,800 1,350 900 360
E32-T17L
2,000 1,400 1,000 700 280
750 550 450 260 100
450 300 250 150 60
2,800 2,000 1,550 1,000 400
1,700 1,200 950 600 240
750 550 450 250 100
2,500 1,800 1,350 900 360
680 480 400 220 90
20,000
High-resolution
*1
Mode
20,000
*1
Standard Mode
*1
20,000
High-speed
Mode
*1
20,000
Super-high-
speed Mode
8,000
Reflective Models (Unit: mm)
Diffuse-
reflective
Type Tough Mode
E32-D11N/
E32-D12R/E32-D15XR/
E32-DC200BR(B4R)
E32-D14LR 220 160 100 60 28
E32-D15YR/E32-D15ZR 200 140 100 52 24
E32-D211R/E32-D21R/
E32-D22R/
E32-DC200FR(F4R)
E32-D24R 70 52 30 20 8
E32-DC200/E32-D15X/
E32-DC200B(B4)
E32-D12 1,120 800 450 320 140
E32-D14L 560 400 220 160 72
E32-D15Y/E32-D15Z 480 340 200 130 60
E32-D211/E32-DC200E/
E32-D22/
E32-DC200F(F4)
E32-D24 140 100 60 40 16
E32-D11/E32-D15XB 840 600 350 240 100
E32-D21B/E32-D221B 300 220 280 90 40
E32-D21/E32-D22B 140 100 60 40 16
E32-D11U 840 600 350 240 100
840 600 350 240 100
140 100 60 40 16
1,400 1,000 600 400 180
360 260 160 100 44
High-resolution
Mode
Standard Mode
High-speed
Mode
Super-high-
speed Mode
4