1: 2 m cable/sensing distance of 100 mm
4: 2 m cable/sensing distance of 200 mm
6: M12 connector/sensing distance of 100 mm
9: M12 connector/sensing distance of 200 mm
6. Adjuster
Blank: with volume adjuster/L-on/D-on by wire
H:without volume adjuster/L-on/D-on by wire
7. Emitter/ Receiver
L: emitter
D: receiver
8. Kind of connection
Blank: standard 2 m cable or M12 connector
M1J: pre-wired with 30 cm cable and
M12 plug connector (4 pin)
M3J: pre-wired with 30 cm cable and
M8 plug connector (4 pin)
M5J: pre-wired with 30 cm cable and
M8 plug connector (3 pin)
M1TJ: pre-wired with 30cm cable and Twist&Click
M12 plug connector (4 pin)
9. Cable length
Blank: M12 connector
Number: cable length
4Standard Photoelectric Sensors
Mounting and dismounting
Mounting
Step 1
2.5 to 2.9 mm
dia 20.1 to 20.2 mm
Insert the snap holder into the
mounting hole from the front
Step 2
Insert the sensor into the snap
holder from the back
Dismounting
Step 1
Verify the correct position
(a clicking sound can be heard)
Verify the correct position
(a clicking sound can be heard)
Apply soft pressure to the sensor
lens in the indicated areas (e.g. with
two thumbs)
Step 2
Press down both snap-fits and push
the snap holder forward.
Remove the sensor
Remove the snap holder